York Tm9v User Manual

444555-YTG-A-0209  
DESCRIPTION  
These compact units employ induced combustion, reliable hot  
surface ignition and high heat transfer aluminized tubular heat  
exchangers. The units are factory shipped for installation in  
upflow or horizontal applications and may be converted for  
downflow applications.  
These furnaces are designed for residential installation in a  
basement, closet, alcove, attic, recreation room or garage and  
are also ideal for commercial applications. All units are factory  
assembled, wired and tested to assure safe dependable and  
economical installation and operation.  
These units are Category IV listed and may be vented either  
through side wall or roof applications using approved plastic  
combustion air and venr piping.  
TECHNICAL GUIDE  
96% TWO STAGE VARIABLE SPEED  
GAS-FIRED RESIDENTIAL  
FEATURES  
MULTI-POSITION GAS FURNACES  
Two stage heating operation includes two stage gas valve,  
two stage inducer operation and variable speed ECM blower  
operation. Adjustable delay timer allows two stage operation  
with a single stage thermostat.  
MODELS: TM9V  
NATURAL GAS  
60 - 120 MBH INPUT  
Easily applied in upflow, horizontal left or right, or downflow  
installation with minimal conversion necessary.  
Compact, easy to install, ideal height 33" tall cabinet.  
ECM variable speed drive for cooling SEER enhancement,  
improved comfort with optional airflow delay profiles, and  
continuous fan options for IAQ performance.  
Easy access to controls to connect power/control wiring.  
Built-in, high level self diagnostics with fault code display.  
Low unit amp requirement for easy replacement application.  
All models are convertable to use propane (LP) gas.  
Electronic Hot Surface Ignition saves fuel cost with  
increased dependability and reliability.  
100% shut off main gas valve for extra safety.  
24V, 40 VA control transformer and blower relay supplied for  
add-on cooling.  
Hi-tech tubular aluminized steel primary heat exchanger with  
stainless steel tube/aluminum fin secondary heat exchanger  
for outstanding efficiency.  
Solid removable bottom panel allows easy conversion.  
Airflow leakage less than 1% of nominal airflow for  
ductblaster conditions.  
EFFICIENCY  
RATING  
CERTIFIED  
No knockouts to deal with, making installation easier.  
Movable duct connector flanges for application flexibility.  
Quiet inducer operation, burner, and blower operation.  
Inducer rotates for easy conversion of venting options.  
Fully supported blower assembly for easy access and  
removal of blower.  
ISO 9001  
Certified Quality  
Management System  
External air filters used for maximum flexibility in meeting  
customers IAQ needs.  
Due to continuous product improvement,  
specifications are subject to change without notice.  
Insulated blower compartment for thermal and acoustic  
performance.  
up-to-date technical information.  
1/4 turn knobs provided for easy independent door removal.  
Internal condensate trap design (patent pending) provides  
condensate management options, easy visual operation  
check, and is self priming to prevent nuisance problems.  
Additional efficiency rating information can  
Protection included from air intake, exhaust vent or  
condensate blockage.  
WARRANTY  
Lifetime limited warranty on both heat exchangers to the origi-  
nal purchaser; a 20-year limited warranty from original installa-  
tion date to subsequent purchaser.  
Venting applications maybe installed as either 2 pipe sealed  
combustion or single pipe vent using indoor combustion air.  
10-year warranty on the heat exchanger in commercial applica-  
tions.  
5-year limited parts warranty.  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
444555-YTG-A-0209  
SIDEWALL VENT TERMINATION KIT -  
S1-1HT0901 (3")  
S1-1HT0902 (2")  
For use on sidewall, two-pipe installations only. Provide a more  
attractive termination for locations where the terminal is visable  
on the side of the home.  
FILTER PERFORMANCE  
The airflow capacity data published in the “Blower Perfor-  
mance” table listed above represents blower performance  
WITHOUT filters.  
All applications of these furnaces require the use of field  
installed air filters. All filter media and mounting hardware or  
provisions must be field installed external to the furnace cabi-  
net. DO NOT attempt to install any filters inside the furnace.  
CONDENSATE NEUTRALIZER KIT - 1NK0301  
Neutralizer cartridge has a 1/2" plastic tube fittings for installa-  
tion in the drain line. Calcium carbonate refill media is also  
available from the Source 1 Parts (p/n 026-30228-000).  
NOTE: Single side return above 1800 CFM is approved as long  
as the filter velocity does not exceed filter manufacturer’s rec-  
ommendation and a transition is used to allow use on a 20x25  
filter.  
SIDE RETURN FILTER RACKS -  
S1-1SR0200 - All Models  
S1-1SR0402 - All Models  
Recommended Filter Sizes (High velocity 600 FPM)  
BOTTOM RETURN FILTER RACKS -  
Cabinet  
Size  
Side  
(in)  
Bottom  
(in)  
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets  
S1-1BR0521 or 1BR0621 - For 21” cabinets  
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets  
CFM  
1200  
1600  
2000  
2000  
B
C
C
D
16 x 25  
16 x 25  
16 x 25  
20 x 25  
20 x 25  
22 x 25  
1BR05xx series are galvanized steel filter racks. 1BR06xx are  
pre-painted steel filter racks to match the appearance of the fur-  
nace cabinet.  
(2) 16 x 25  
(2) 16 x 25  
NOTES:  
COMBUSTIBLE FLOOR BASE KIT -  
1. Air velocity through throwaway type filters may not exceed 300 feet  
per minute (91.4 m/min). All velocities over this require the use of  
high velocity filters.  
2. Do not exceed 1800 CFM using a single side return and a 16x25 fil-  
ter. For CFM greater than 1800, you may use two side returns or one  
side and the bottom or one return with a transition to allow use of a  
20x25 filter.  
For installation of these furnaces in downflow applications  
directly onto combustible flooring material, These kits are  
required to prevent potential overheating situations.tible floor  
base kit provides access for combustible airflow.  
S1-1CB0517 - For 17-1/2” cabinets  
S1-1CB0521 - For 21” cabinets  
Unit Clearances to Combustibles  
S1-1CB0524 - For 24-1/2” cabinets  
Application  
Top  
Upflow  
Downflow  
Horizontal  
EAC TRANSITION KITS -  
1"  
0"  
0"  
0"  
0"  
0"  
0"  
For installation of EAC accessories with these furnaces to pro-  
vide easy transition of return airflow through the EAC to get the  
proper sealing and reduced airflow leakage.  
Vent  
0"  
0"  
Rear  
0"  
0"  
Side  
0"  
1"  
0"  
S1-1TK1001 - For all models using side return  
Front*  
Floor  
0"  
Combustible  
Yes  
S1-1TK1017 - For 17-1/2” cabinets using bottom return  
S1-1TK1021 - For 21” cabinets using bottom return  
S1-1TK1024 - For 24-1/2” cabinets using bottom return  
Combustible1  
Combustible  
Yes  
Closet  
Line Contact  
Yes  
No  
No  
Yes  
HIGH ALTITUDE PRESSURE SWITCHES -  
1. For combustible floors only when used with special sub-base.  
* - 24" clearance in front and 18" on side recommended for service access.  
All furnaces approved for alcove and attic installation.  
For installation where the altitude is less than 5,000 feet it is not  
required that the pressure switch be changed. For altitudes  
above 5,000 feet, see kits below.  
ACCESSORIES  
PROPANE (LP) CONVERSION KIT -  
S1-1PS3306 - 080  
S1-1PS3307 - 060  
S1-1NP0347 - All Models  
This accessory conversion kit may be used to convert natural  
gas (N) units for propane (LP) operation.  
S1-1PS3302 - 100, 120  
ROOM THERMOSTATS - A wide selection of compatible ther-  
mosets are available to provide optimum performance and fea-  
tures for any installation.  
CONCENTRIC VENT TERMINATION -  
S1-1CT0302 (2") & S1-1CT0302-636 (2")  
S1-1CT0303 (3") & S1-1CT0303-636 (3")  
1H/1C, manual change-over electronic non-programmable ther-  
mostat.  
For use through rooftop, sidewall. Allows combustion air to  
enter and exhaust to exit through single common hole. Elimi-  
nates unslightly elbows for a cleaner installation.  
1H/1C, auto/manual changeover, electronic programmable,  
deluxe 7-day, thermostat.  
1H/1C, auto/manual changeover, electronic programmable.  
* For the most current accessory information, refer to the price  
book or consult factory.  
Johnson Controls Unitary Products  
3
AIR FLOW DATA  
HIGH / LOW SPEED COOLING AND HEAT PUMP CFM  
080B12  
060B12  
080C16  
100C20  
Jumper Settings  
High  
1343  
1116  
1235  
1026  
1079  
889  
900  
787  
814  
712  
Low  
865  
727  
791  
661  
709  
590  
599  
531  
542  
490  
499  
456  
High  
1320  
1093  
1203  
1001  
1080  
880  
910  
803  
836  
738  
Low  
882  
755  
810  
693  
730  
641  
642  
585  
597  
557  
561  
529  
COOL Tap  
ADJ Tap*  
A
B
A
B
A
C
B
D
C
D
C
D
B
B
A
A
C
B
C
B
A
A
C
C
725  
641  
749  
682  
100C16  
Jumper Settings  
High  
1787  
1503  
1620  
1405  
1462  
1217  
1245  
940  
Low  
1171  
987  
1053  
914  
964  
785  
818  
608  
702  
551  
626  
544  
High  
1818  
1545  
1661  
1427  
1497  
1234  
1265  
977  
1116  
884  
1019  
791  
Low  
1192  
1030  
1083  
936  
991  
819  
832  
648  
728  
572  
666  
519  
COOL Tap  
ADJ Tap*  
A
B
A
B
A
C
B
D
C
D
C
D
B
B
A
A
C
B
C
B
A
A
C
C
1091  
852  
983  
764  
120D20  
Jumper Settings  
High  
2019  
1790  
1818  
1630  
1649  
1269  
1432  
1078  
1169  
986  
Low  
1290  
1174  
1195  
1068  
1082  
848  
956  
704  
770  
638  
High  
2006  
1687  
1845  
1552  
1694  
1502  
1400  
1365  
1364  
1232  
1225  
1117  
Low  
1397  
1131  
1282  
1050  
1157  
1011  
944  
922  
931  
808  
808  
COOL Tap  
ADJ Tap*  
A
B
A
B
A
C
B
D
C
D
C
D
B
B
A
A
C
B
C
B
A
A
C
C
1062  
866  
685  
576  
718  
HIGH / LOW HEAT CFM  
80B12  
060B12  
80C16  
Jumper Settings  
High  
1364  
1253  
1102  
1014  
Low  
843  
745  
660  
607  
High  
Low  
945  
887  
840  
768  
HEAT Tap  
ADJ Tap*  
Any  
1433  
1320  
1223  
1134  
A
B
C
D
Any  
Any  
Any  
100C16  
120D20  
Jumper Settings  
High  
1684  
1542  
1426  
1289  
Low  
1095  
1011  
927  
High  
1795  
1585  
1420  
1201  
Low  
1171  
1047  
929  
HEAT Tap  
ADJ Tap*  
Any  
A
B
C
D
Any  
Any  
Any  
832  
785  
100C20  
Jumper Settings  
High  
2194  
1999  
1799  
1614  
Low  
1417  
1290  
1182  
1062  
High  
1937  
1757  
1594  
1429  
Low  
1323  
1199  
1062  
957  
HEAT Tap  
ADJ Tap*  
Any  
Any  
Any  
Any  
A
B
C
D
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0” to 0.6” w.c.  
static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than 1.0” w.c. external static  
pressure is not recommended.  
NOTE: At some settings, LOW COOL and/or LOW HEAT airflow may be lower that what is required to operate an airflow switch on certain models of electronic air clean-  
ers. Consult the instructions for the electronic air cleaner for further details.  
* The ADJ “D” tap should not be used.  
Subject to change without notice. Printed in U.S.A.  
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.  
444555-YTG-A-0209  
Supersedes: Nothing  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  

Lifebreath Maxtop User Manual
Riccar Summer Breeze Rsbhp O User Manual
Samsung Ast18s0gb User Manual
Samsung Eh052cav User Manual
Samsung Um 20a1 B1 E3 User Manual
Sharp Mx 6201n User Manual
Subaru Robin Power Products Smarttouch Xl 9170xlcc User Manual
Toshiba Carrier Rav Sp300ut Ul User Manual
Toshiba Ras B10gkvp E User Manual
Vtech 6043 User Manual