York Affinity 292443 Xtg D 0508 User Manual

292443-XTG-D-0508  
®
FLEXIBLE LIGHT COMMERCIAL UNIT  
GENERAL  
York® Affinity™ Series packaged units are designed to han-  
dle applications ranging from residential to light commercial  
and any in between. The Affinity™ is a unit that gives you the  
flexibility and choices you need in today’s market.  
TECHNICAL GUIDE  
AFFINITY™ SERIES  
EXPORT ONLY  
FEATURING  
SINGLE PACKAGE GAS/ELECTRIC  
AIR COOLED AIR CONDITIONERS  
2.5 THROUGH 5 NOMINAL TON  
COOLING/GAS HEATING UNITS (NATURAL GAS OR  
PROPANE)  
LOW PROFILE  
QUIET OPERATION  
COMMON FOOTPRINT  
OPTIONAL SLIDE IN MOTORIZED DAMPERS  
OPTIONAL SLIDE IN ECONOMIZERS  
OPTIONAL PROPANE CONVERSION KIT  
OPTIONAL HIGH ALTITUDE CONVERSION KIT  
(NATURAL GAS/PROPANE)  
DNA030 THROUGH 060  
8.6 - 9.2 EER  
FULL PERIMETER BASE RAILS  
BOTTOM AND SIDE UTILITY CONNECTIONS  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
292443-XTG-D-0508  
CONDENSATE PAN - A non-corrosive, long-lasting, water-  
tight pan is positioned below the evaporator coil to collect and  
drain all condensate. Less collection of stagnate condensate  
will build-up. The condensate pan conforms to ASHRAE 62-  
89 standards (Ventilation for Acceptable Indoor Air Quality).  
DESCRIPTION  
These packaged cooling/heating air conditioners are  
designed for outdoor installation. Only utility and duct con-  
nections are required at the point of installation.  
The gas-fired heaters have aluminized steel tubular heat  
exchangers and spark to pilot ignition. They are available in  
natural gas with field conversion to propane.  
CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI cop-  
per connection is more tolerable during installation and is  
more durable over time. The connection is rigidly mounted to  
assure proper fit and leak tight seal.  
STANDARD FEATURES/BENEFITS  
DURABLE FINISH - With a heavy duty cabinet made of pow-  
der-painted, galvanized steel the neutral color blends into  
surrounding areas. The powdered paint, provides a better  
paint to steel bond, which resists corrosion and rust creep.  
The special primer formulas and glossy finish insure less fad-  
ing when exposed to sunlight and offers a more attractive on  
site appearance. This paint finish meets ASTM-B117 stan-  
dards for 1000 hours salt spray rating. The highest in the  
industry.  
OPERATING EFFICIENCY - All units provide high operating  
efficiencies and have a minimum AFUE of 80% and EERs of  
8.6 to 9.2. All efficiencies exceed legislated minimum levels.  
ON SITE FLEXIBILITY - All model sizes share a common,  
compact design cabinet in a single footprint. The installer has  
the flexibility of setting one curb and placing the proper ton-  
nage unit on that curb after the internal load has been deter-  
mined. Field convertible duct connections from side shot to  
down shot allows the installer to have greater flexibility with  
less inventory.  
FULL PERIMETER BASE RAILS - The easily removable  
base rails provide a solid foundation for the entire unit and  
protects the unit during shipment. The rails provide fork lift  
access from all sides, and rigging holes are also provided so  
that an overhead crane can be used to place the units on a  
roof. On applications where the unit is placed on a pad, the  
base will keep the unit off the pad to deter corrosion. On  
applications where height is limited, the inch high base rails  
may be removed on location.  
LOWER INSTALLATION COST - Installation time and costs  
are reduced by easy power and control wiring connections.  
The small base dimension means less space is required on  
the ground or roof, plus, the installer can fit this unit between  
the wheel wells of full size pick-up truck. All models are well  
under 500 pounds.  
All units are completely wired, charged with R-22 and tested  
prior to shipment. Unique test stations using a new state of  
the art computerized process system are used to insure prod-  
uct quality. Refrigerant charge, and component part numbers  
are verified via computers at assembly. Vital run test statistics  
such as system pressure, motor currents, air velocity and  
temperature, unit vibration, and gas system safeties are mon-  
itored and recorded by the system to insure unit perfor-  
mance.  
MORE ATTRACTIVE APPEARANCE - A single piece Water  
Shed top cover containing a top discharge condenser fan  
arrangement requires less square footage on installation and  
provides a wider variety of installations. The one piece design  
adds greater water integrity. Rounded corners with water drip  
edges add to the attractive appearance. The cabinet panels  
have a non-fibrous insulation that will not release insulation  
fibers into conditioned area.  
TOP DISCHARGE - The top discharge condenser fan does  
not disrupt neighboring areas or does this dry-out vegetation  
surrounding the unit. The warm air from the top mounted fan  
is blown up away from the structure and any landscaping.  
This allows compact location on multi-unit applications.  
Equal size, side supply and return duct connections allows  
easy hook-up of ducts to match low crawl spaces without  
transition pieces.  
UTILITY CONNECTIONS MADE EASY - Gas and electric  
utility knockouts are provided through the bottom as well as  
the side of the unit. Utility connections can be made quickly  
and with a minimum amount of field labor. A field supplied  
and field installed electrical disconnect switch must be  
installed.  
CONDENSER COIL GRILLE - A multi-piece totally enclosed,  
rigidly mounted condenser coil grille provides protection from  
objects after installation and provides protection during transit.  
LOW OPERATING SOUND LEVEL - The upward air flow  
carries the normal operating noise up and away from the liv-  
ing area. The rigid top panel effectively isolates any motor  
sound. Isolator mounted compressor and the rippled fins of  
the condenser coil muffle the normal fan motor and compres-  
sor operating sounds. The unique formed base pan also aids  
in sound alterations with it's Super-Structure design. This  
design strategically places embossments in the pan for opti-  
mum strength and rigidity.  
CONVERTIBLE AIRFLOW DESIGN - The bottom duct open-  
ings are covered when they leave the factory ready to be  
used for a side supply / side return application. If a bottom  
supply / bottom return application is desired, you simply  
remove the two panels from the bottom of the unit and place  
them in the side supply / side return duct openings. No panel  
cutting is required and no accessory panel is necessary.  
Convertible airflow design allows maximum field flexibility and  
minimum inventory.  
Johnson Controls Unitary Products  
3
   
292443-XTG-D-0508  
FAN SYSTEM - All models operate over a wide range of  
design conditions with a 3-speed direct-drive fan motor.  
These units easily match all types of applications and pro-  
vides greater on site flexibility to match comfort requirement.  
compartment has an additional large panel with a built-in  
handle tab. Removing this panel will allow the blower assem-  
bly to slide-out for easy removal for maintenance and ease of  
trouble shooting.  
SIMPLE CONTROL CIRCUIT - A low voltage printed circuit  
board contains a diagnostic indicator light and a low voltage  
terminal strip. An additional set of pin connectors is also pro-  
vided to simplify the field interface of external controls. Mate-  
n-lock plug connectors are used. The electrical control box is  
not located in the compressor compartment. The controls are  
mounted on a Control-Tilt control panel to allow the access  
cover to be removed for trouble shooting and maintenance  
without affecting the normal system operating pressures. All  
wiring internal to the unit is color/number coded.  
REPLACEMENT PARTS - The installer has no need to carry  
an inventory of unique parts or needs special training to  
replace any of the components parts for these units. All are  
easily obtained from Source 1 or other part houses.  
SYSTEM INTEGRATION - Each unit has the internal ability  
to integrate an electronic air cleaner or humidifier to work in  
conjunction with the base unit.  
FIELD-INSTALLED ACCESSORIES  
PROPANE CONVERSION KIT - Kit includes burner orifices,  
gas valve conversion and installation instructions necessary  
to field convert unit from natural gas to propane.  
PROTECTED COMPRESSOR - The compressor is internally  
protected against high pressure and temperature. This is  
accomplished by the simultaneous operation of high pressure  
relief valve and a temperature sensor which protect the com-  
pressor if undesirable operating conditions occur.  
HIGH ALTITUDE CONVERSION KIT (Natural Gas/Propane)  
- Kit includes all necessary labels and instructions to field  
alter units with natural gas/propane for installation above  
2000 feet. Burner orifices must be obtained from Source 1  
Parts. Propane Conversion Kit must be obtained separately.  
EXCLUSIVE COIL DESIGN - Grooved copper tubes and  
enhanced aluminum fin construction improves heat transfer  
for maximum efficiency and durability.  
ECONOMIZER DOWN DISCHARGE / SUPPLY KIT - Modu-  
lating integrated economizer provides simultaneous opera-  
tion between the mechanical cooling and economizer  
operation. Independent blade design insures proper control  
and less than 1% leak rate. Includes hood and mesh bird  
screen filter integrated into the hood, dry bulb sensor and  
relief damper. Separate field accessories of single enthalpy  
and dual enthalpy are also available. A built-in barometric  
relief of 25% is provided.  
HEAT EXCHANGERS - Are corrosion-resistant, aluminized-  
steel tubular construction to provide long-life, trouble-free  
operation. The unique blow-through design also assures that  
condensate does not collect in humid areas when in the cool-  
ing cycle. This adds to longer heat exchanger life and higher  
long term efficiencies.  
POST PURGE INDUCED DRAFT COMBUSTION - Exhausts  
combustion products from the heat exchanger upon comple-  
tion of the heating cycle to prolong the heat exchanger life.  
SINGLE ENTHALPY SENSOR - Sensor replaces dry bulb  
sensor standard in economizer kit. Provides improved econo-  
mizer operation by sensing the dry bulb temperature from  
outdoors plus the enthalpy content of the outdoor air.  
SELF DIAGNOSTIC FAN CONTROL MODULE - Due to this  
self diagnostic control, less on site time is required to trouble  
shoot these units.  
DUAL ENTHALPY SENSOR - Additional sensor to single  
enthalpy sensor. Sensor senses both the return air tempera-  
ture dry bulb and humidity in conjunction with the single  
enthalpy to determine the most economical mix. Single  
Enthalpy sensor also required.  
SPARK TO PILOT IGNITION - Provides faster heat delivery.  
This ignition is highly reliable, durable and eliminates nui-  
sance lockouts.  
MULTI PORT IN-SHOT BURNERS - No field adjustment is  
required to mix the air and gas. These burners are con-  
structed of high-grade corrosion-resistant, aluminized-steel.  
PRESSURE SWITCH UPGRADE KIT - Contains screw in  
type High pressure, Low Pressure/Loss of Charge switch,  
freeze protection switch and lockout relay. Switches are  
placed onto existing scharder ports located in the unit by fur-  
nished adapters. When abnormal conditions are sensed  
through the pressure switches, the unit will lock out prevent-  
ing any further operation until reset or problem is corrected.  
Package agency approved.  
LOW MAINTENANCE - Long life, permanently lubricated  
condenser and evaporator fan motor bearings need no  
annual maintenance adding greater reliability to the unit.  
Blower assembly can be easily cleaned by the unique Slip-  
Track slide-out blower assembly.  
SECURED SERVICE ACCESS PORTS - Protected, exter-  
nally mounted, re-usable service access ports are provided  
on both the high and low lines for ease of evacuating and  
charging the system. No final field mounting required.  
HAIL GUARD KIT - Kit contains protective grilles made of  
expanded aluminum with full perimeter frame. Sloped hoods  
are also included to assure maximum protection.  
EASY SERVICE ACCESS - A large, single panel covers the  
electrical and gas controls makes servicing easy. The blower  
ANTI SHORT CYCLE TIMER - Automatically prevents the  
compressor from restarting for 5 minutes after cycled off.Not  
4
Johnson Controls Unitary Products  
 
292443-XTG-D-0508  
required if Thermostat 2ET07700224 and 2ET04700224 are  
used.  
ROOF CURBS - NRCA approved curbs provide proper fit to  
base unit for rooftop installations. Curbs are designed to be  
assembled through hinge pins in each corner. Kit also pro-  
vides seal strip to assure a water tight seal. 8 and 14 inch  
high roof curbs are available.  
MOTORIZED FRESH AIR DAMPER - Designed for duct  
mounted side supply/return and unit mounted down supply/  
return applications. Damper capable of providing 0% through  
50% of outdoor air (field supplied). Closes on power loss,  
includes hood and screen assembly.  
MANUAL OUTDOOR DAMPER - Provides 0% through 50%  
outdoor air capability (field adjustable). Designed for duct  
mounted side supply/return applications. Includes hood and  
screen assembly.  
FILTER / FRAME KIT (Single Phase only) - Kit contains the  
necessary hardware to field install return air filters into the  
base unit. Pre-cut filter racks and appropriate cleanable stan-  
dard size filters are shipped in one kit. The fiter rack is suit-  
able for either 1” or 2” filters (1” filter is supplied). This kit is  
available for single phase horizontal or vertical duct applica-  
tion only. Standard in all 3 phase models  
WALL THERMOSTAT - The units are designed to operate  
with 24-volt electronic and electro-mechanical thermostats.  
All units can operate with single stage heat / single stage cool  
thermostats - with or without the economizer.  
LOW AMBIENT KIT - Kit provides necessary hardware to  
convert unit to operate in cooling cycle down to 0 F. Standard  
unit operation 45 F.  
RECTANGLE TO ROUND ADAPTERS - Kit includes one  
supply and one return air rectangle to round duct adapter.  
Adapters are preformed and designed to fit over current duct  
openings on the base unit. Transition is from side square duct  
opening to 14" round duct opening.  
TRANSFORMER KIT - Kit provides necessary hardware to pro-  
vide single phase models from factory furnished 40 VA trans-  
former capability to 75 VA transformer capability. (Required on  
installations with economizer or motorized damper.)  
DIRECT DRIVE  
CONDENSER FAN  
MOTOR  
BLOW-THROUGH DESIGN  
WITH RELIABLE ALUMINIZED  
STEEL TUBULAR HEAT  
EXCHANGERS  
HIGHLY EFFICIENT  
ENHANCER  
COPPER TUBE/ALUMINUM FIN  
EVAPORATOR COIL  
HIGHLY EFFICIENT  
ENHANCED COPPER  
TUBE/ALUMINUM FIN  
CONDENSER COIL  
LONG-LASTING  
POWDER PAINT  
FINISH  
DECORATIVE  
PROTECTIVE  
COIL GUARD  
REAR & BOTTOM  
RETURN AIR  
AND SUPPLY AIR  
DUCT OPENINGS  
HIGH EFFICIENCY  
COMPRESSOR  
RIGIDLY MOUNTED  
PILOT ASSEMBLY  
HEAVY GAUGE  
REMOVEABLE  
BASE RAILS  
HIGH GRADE  
ALUMINIZED  
IN-SHOT BURNERS  
LOW VOLTAGE  
TERMINAL BLOCK  
3-SPEED DIRECT DRIVE  
BLOWER MOTOR WITH  
SELF-DIAGNOSTIC CONTROLS  
WITH "COMFORT MATCH" SPEED  
CONTROL  
SLIDE-OUT BLOWER ASSEMBLY  
AUTOMATIC  
GAS VALVE  
POWER VENTER MOTOR  
HIGH VOLTAGE  
TERMINAL BLOCK  
(1/2"- 14NPTI)  
FIGURE 2 - UNIT COMPONENT LOCATION  
Johnson Controls Unitary Products  
5
   
292443-XTG-D-0508  
TABLE 1: PHYSICAL DATA  
DNA  
042  
MODEL  
030  
10 x 8  
1/2  
036  
11 x 10  
3/4  
048  
060  
CENTRIFUGAL BLOWER (Dia. x W. in.)  
FAN MOTOR HP (3 Speed)  
ROWS DEEP  
11 x 10  
3/4  
12 x 11  
12 x 11  
EVAPORATOR  
BLOWER  
1
3
1
3
2
2
3
EVAPORATOR  
COIL  
FINS PER INCH  
13  
15  
13  
13  
13  
FACE AREA (Sq. Ft.)  
3.5  
3.5  
3.5  
4.5  
4.5  
PROPELLER DIA. (in.)  
22  
22  
22  
22  
22  
CONDENSER  
FAN  
FAN MOTOR HP  
1/4  
1/4  
1/4  
1/4  
1/4  
NOM. CFM TOTAL  
2,400  
1
2,400  
1
2,400  
1
3,000  
1
3,000  
1
ROWS DEEP  
CONDENSER  
COIL  
FINS PER INCH  
16  
20  
20  
20  
20  
FACE AREA (Sq. Ft.)  
11.7  
4 / 12  
2.6/20x20  
43  
11.7  
4 / 3  
2.6/20x20  
43  
11.7  
4 / 9  
2.6/20x20  
43  
14.8  
6 / 0  
3.3/20x12  
40  
14.8  
5 / 4  
3.3/20x12  
40  
CHARGE  
REFRIGERANT 22 (lbs./oz.)  
FACE AREA (Sq. Ft.) Size (Nominal)  
NATURAL GAS BURNER ORIFICE NO. (Drill Size)  
PROPANE BURNER ORIFICE NO. (Drill Size)  
GAS CONNECTION SIZE  
1
FILTER  
FURNACE  
SECTION  
55  
55  
55  
53  
53  
1/2 NPTI  
1/2 NPTI  
1/2 NPTI  
1/2 NPTI  
1/2 NPTI  
COMPRESSOR  
TYPE  
HERMETICALLY SEALED  
(R = RECIPROCATING, S = SCROLL)  
R
R
R
S
S
1. See FILTER/FRAME KIT on page 5.  
6
Johnson Controls Unitary Products  
 
292443-XTG-D-0508  
TABLE 2: RATINGS COOLING/GAS HEATING  
1
GAS HEAT CAPACITY / EFFICIENCIES  
4
NET COOLING CAPACITY  
SOUND  
MODEL  
DNA  
TEMP.  
RISE  
RATING  
INPUT  
(MBH)  
OUTPUT  
(MBH)  
NUMBER OF  
BURNERS  
AFUE  
(%)  
3
MBH  
2
EER  
(dbels)  
(°F) RANGE  
030N03606  
030N05606  
036N03606  
036N05606  
036N07206  
036N03625  
036N03646  
036N05625  
036N05646  
036N07225  
036N07246  
042N03606  
042N05606  
042N07206  
042N03625  
042N03646  
042N05625  
042N05646  
042N07225  
042N07246  
048N06506  
048N09006  
048N11006  
048N06525  
048N06546  
048N09025  
048N09046  
048N11025  
048N11046  
060N06506  
060N09006  
060N11006  
060N06525  
060N06546  
060N09025  
060N09046  
060N11025  
060N11046  
29  
9
78  
78  
82  
82  
82  
82  
82  
82  
82  
82  
82  
84  
84  
84  
84  
84  
84  
84  
84  
84  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
45  
70  
36  
56  
36  
56  
72  
36  
36  
56  
56  
72  
72  
36  
56  
72  
36  
36  
56  
56  
72  
72  
64  
86  
108  
64  
64  
86  
86  
108  
108  
64  
86  
108  
64  
64  
86  
86  
108  
108  
80.2  
80.2  
80.4  
80.2  
80.1  
80.4  
80.4  
80.2  
80.2  
80.1  
80.1  
80.4  
80.2  
80.1  
80.4  
80.4  
80.2  
80.2  
80.1  
80.1  
80  
2
3
2
3
4
2
2
3
3
4
4
2
3
4
2
2
3
3
4
4
3
4
5
3
3
4
4
5
5
3
4
5
3
3
4
4
5
5
25 - 55  
30 - 60  
25 - 55  
25 - 55  
30 - 60  
25 - 55  
25 - 55  
25 - 55  
25 - 55  
30 - 60  
30 - 60  
25 - 55  
25 - 55  
30 - 60  
25 - 55  
25 - 55  
25 - 55  
25 - 55  
30 - 60  
30 - 60  
25 - 55  
30 - 60  
35 - 65  
25 - 55  
25 - 55  
30 - 60  
30 - 60  
35 - 65  
35 - 65  
25 - 55  
30 - 60  
35 - 65  
25 - 55  
25 - 55  
30 - 60  
30 - 60  
35 - 65  
35 - 65  
29  
9
34.8  
34.8  
34.8  
34.8  
34.8  
34.8  
34.8  
34.8  
34.8  
40.5  
40.5  
40.5  
40.5  
40.5  
40.5  
40.5  
40.5  
40.5  
46.5  
46.5  
46.5  
46.5  
46.5  
46.5  
46.5  
46.5  
46.5  
56.5  
56.5  
56.5  
56.5  
56.5  
56.5  
56.5  
56.5  
56.5  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
9
45  
70  
90  
45  
45  
70  
70  
90  
90  
45  
9
70  
9
90  
9
45  
9
45  
9
70  
9
70  
9
90  
9
90  
8.6  
8.6  
8.6  
8.6  
8.6  
8.6  
8.6  
8.6  
8.6  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
8.9  
80  
108  
135  
80  
80  
80  
80  
80  
80  
108  
108  
135  
135  
80  
80  
80  
80  
80  
80  
108  
135  
80  
80  
80  
80  
80  
80  
108  
108  
135  
135  
80  
80  
80  
80  
1. Net Cooling Capacity = ARI 210 standard rating conditions.  
2. (dbels) = ARI 270-95  
3. Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total  
electric power input in watt-hours during the same period.  
4. AFUE = Annual Fuel Utilization Efficiency.  
Johnson Controls Unitary Products  
7
 
292443-XTG-D-0508  
TABLE 3: DNA030 COOLING CAPACITIES - 2-1/2 TON  
AIR ON EVAPORATOR COIL  
TEMPERATURE  
OF AIR ON  
CONDENSER COIL  
750 CFM  
WB °F  
875 CFM  
WB °F  
1,000 CFM  
WB °F  
1,125 CFM  
WB °F  
1,250 CFM  
WB °F  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
NET CAP.  
MBH  
28.1 26.4 24.2 22.6 30.6 28.7 26.3 24.5 32.9 31.0 28.3 26.4 33.2 31.2 28.6 26.7 33.5 31.5 28.8 26.9  
2.99 2.95 2.90 2.89 3.03 2.99 2.94 2.93 3.06 3.02 2.97 2.96 3.13 3.09 3.04 3.03 3.20 3.16 3.11 3.10  
TOTAL POWER  
INPUT kW  
86 15.3 19.8 23.6 22.6 18.6 23.6 26.0 24.5 21.9 27.4 28.3 26.4 21.1 26.8 28.6 26.7 20.2 26.2 28.8 26.9  
83 14.5 19.0 22.8 21.9 17.0 21.9 25.6 24.2 19.4 24.9 28.3 26.4 19.3 25.1 28.6 26.7 19.3 25.2 28.8 26.9  
80 13.7 18.2 22.1 21.2 15.3 20.3 24.6 23.6 16.9 22.4 27.2 26.1 17.6 23.3 28.0 26.5 18.3 24.2 28.8 26.9  
77 13.0 17.4 21.3 20.4 13.7 18.7 23.0 22.0 14.5 20.0 24.7 23.6 15.9 21.6 26.3 24.8 17.3 23.3 27.8 25.9  
74 12.2 16.7 20.5 19.6 12.1 17.1 21.4 20.4 12.0 17.5 22.2 21.1 14.2 19.9 24.6 23.0 16.4 22.3 26.9 24.9  
85 °F  
71  
68  
-
-
15.9 19.7 18.8  
15.1 19.0 18.1  
-
-
15.5 19.8 18.7  
13.8 18.1 17.1  
-
-
15.0 19.8 18.7  
12.6 17.3 16.2  
-
-
18.2 22.8 21.3  
16.5 21.1 19.6  
-
-
21.3 25.9 24.0  
20.4 24.9 23.0  
NET CAP.  
MBH  
26.8 25.0 22.3 21.4 29.2 27.3 24.3 23.4 31.7 29.6 26.4 25.4 32.0 29.9 26.6 25.6 32.2 30.1 26.8 25.8  
3.18 3.14 3.08 3.07 3.22 3.18 3.11 3.11 3.26 3.22 3.15 3.15 3.34 3.30 3.23 3.22 3.42 3.38 3.30 3.30  
TOTAL POWER  
INPUT kW  
86 17.9 22.3 22.3 21.4 19.9 24.9 24.3 23.4 22.0 27.5 26.4 25.4 21.0 26.7 26.6 25.6 19.9 25.9 26.8 25.8  
83 15.6 20.1 22.3 21.4 17.5 22.5 24.3 23.4 19.3 24.9 26.4 25.4 19.1 24.9 26.6 25.6 19.0 24.9 26.8 25.8  
80 13.4 17.8 21.0 20.0 15.0 20.0 23.6 22.4 16.6 22.2 26.1 24.8 17.3 23.1 16.5 25.3 18.0 24.0 26.8 25.8  
77 11.1 15.6 18.8 17.7 12.6 17.5 21.1 19.9 14.0 19.5 23.5 22.2 15.5 21.2 24.6 23.5 17.0 23.0 25.8 24.8  
74 8.9 13.4 16.5 15.5 10.1 15.1 18.7 17.5 11.3 16.8 20.8 19.5 13.7 19.4 22.8 21.7 16.0 22.0 24.9 23.9  
95 °F  
71  
68  
-
-
11.1 14.3 13.3  
8.9 12.1 11.0  
-
-
12.6 16.2 15.0  
10.2 13.7 12.6  
-
-
14.1 18.1 16.8  
11.5 15.4 14.1  
-
-
17.6 21.0 19.8  
15.8 19.2 18.0  
-
-
21.0 23.9 22.9  
20.1 22.9 21.9  
NET CAP.  
MBH  
25.4 23.0 20.6 20.1 27.7 25.0 22.5 21.9 30.0 27.1 24.4 23.8 30.4 27.4 24.7 24.0 30.7 27.8 25.0 24.3  
2.94 3.31 3.23 3.24 2.98 3.36 3.28 3.29 3.03 3.41 3.33 3.34 3.10 3.49 3.41 3.42 3.17 3.57 3.48 3.49  
TOTAL POWER  
INPUT kW  
86 15.9 20.0 20.6 20.1 17.7 22.3 22.5 21.9 19.6 24.7 24.4 23.8 19.5 24.9 24.7 24.0 19.5 25.1 25.0 24.3  
83 14.4 18.5 20.5 19.9 16.1 20.7 22.5 21.8 17.8 22.9 24.4 23.8 18.2 23.5 24.7 24.0 18.6 24.1 25.0 24.3  
80 13.0 17.1 19.6 18.8 14.5 19.1 21.9 21.0 16.1 21.2 24.3 23.3 16.9 22.2 24.6 23.8 17.6 23.2 25.0 24.3  
77 11.5 15.6 18.1 17.3 12.9 17.5 20.3 19.5 14.4 19.5 22.5 21.6 15.5 20.9 23.3 22.5 16.7 22.2 24.0 23.4  
74 10.1 14.2 16.6 15.9 11.3 15.9 18.7 17.9 12.6 17.7 20.8 19.8 14.2 19.5 21.9 21.1 15.7 21.3 23.1 22.4  
105 °F  
115 °F  
125 °F  
71  
68  
-
-
12.7 15.2 14.4  
11.3 13.7 13.0  
-
-
14.3 17.1 16.3  
12.7 15.5 14.7  
-
-
16.0 19.0 18.1  
14.2 17.3 16.3  
-
-
18.2 20.6 19.8  
16.8 19.2 18.4  
-
-
20.4 22.1 21.5  
19.4 21.2 20.6  
NET CAP.  
MBH  
24.1 20.9 19.0 18.8 26.2 22.8 20.7 20.5 28.3 24.6 22.4 22.1 28.8 25.0 22.7 22.5 29.2 25.4 23.1 22.8  
2.70 3.47 3.38 3.40 2.75 3.53 3.44 3.47 2.80 3.60 3.50 3.53 2.86 3.68 3.58 3.61 2.92 3.76 3.66 3.69  
TOTAL POWER  
INPUT kW  
86 13.9 17.7 19.0 18.8 15.5 19.7 20.7 20.5 17.2 21.8 22.4 22.1 18.1 23.0 22.7 22.5 19.1 24.2 23.1 22.8  
83 13.2 17.0 18.8 18.3 14.8 19.0 20.6 20.2 16.4 21.0 22.4 22.1 17.3 22.2 22.7 22.5 18.2 23.3 23.1 22.8  
80 12.6 16.3 18.1 17.6 14.1 18.3 20.2 19.7 15.6 20.2 22.4 21.8 16.4 21.3 22.7 22.3 17.3 22.4 23.1 22.8  
77 11.9 15.7 17.4 16.9 13.3 17.5 19.5 19.0 14.8 19.4 21.6 21.0 15.6 20.5 21.9 21.5 16.3 21.5 22.2 21.9  
74 11.2 15.0 16.7 16.3 12.6 16.8 18.8 18.2 13.9 13.6 20.8 20.2 14.7 19.6 21.0 20.6 15.4 20.6 21.3 21.0  
71  
68  
-
-
14.3 16.1 15.6  
13.6 15.4 14.9  
-
-
16.1 18.0 17.5  
15.3 17.3 16.7  
-
-
17.8 20.0 19.4  
17.0 19.2 18.6  
-
-
18.7 20.2 19.7  
17.9 19.3 18.9  
-
-
19.7 20.4 20.1  
18.8 19.5 19.2  
NET CAP.  
MBH  
22.7 18.9 17.4 17.5 24.7 20.5 18.9 19.0 26.6 22.2 20.4 20.5 27.2 22.6 20.8 20.9 27.7 23.1 21.3 21.4  
2.45 3.63 3.53 3.57 2.51 3.71 3.60 3.64 2.56 3.79 3.68 3.72 2.62 3.87 3.76 3.80 2.68 3.96 3.84 3.89  
TOTAL POWER  
INPUT kW  
86 11.9 15.3 17.4 17.5 13.3 17.2 18.9 19.0 14.7 19.0 20.4 20.5 16.7 21.2 20.8 20.9 18.9 23.4 21.3 21.4  
83 12.0 15.5 17.0 16.7 13.5 17.3 18.7 18.6 14.9 19.1 20.4 20.5 16.3 20.8 20.8 20.9 17.8 22.5 21.3 21.4  
80 12.2 15.6 16.6 16.4 13.6 17.4 18.6 18.3 15.0 19.2 20.5 20.2 16.0 20.4 20.9 20.8 16.9 21.7 21.3 21.4  
77 12.3 15.7 16.7 16.5 13.7 17.5 18.7 18.5 15.1 19.4 20.7 20.4 15.6 20.1 20.5 20.4 16.0 20.8 20.4 20.5  
74 12.4 15.8 16.9 16.8 13.8 17.6 18.8 18.6 15.3 19.5 20.8 20.5 15.2 19.7 20.1 20.1 15.1 19.9 19.5 19.6  
71  
68  
-
-
15.9 17.0 16.7  
16.0 17.1 16.9  
-
-
17.8 18.9 18.7  
17.9 19.1 18.8  
-
-
19.6 20.9 20.7  
19.8 21.1 20.8  
-
-
19.3 19.8 19.7  
19.0 19.4 19.3  
-
-
19.0 18.6 18.7  
18.1 17.7 17.8  
ALL SENSIBLE CAPACITY  
1. These capacities are net capacities (the indoor fan heat is deducted).  
8
Johnson Controls Unitary Products  
 
292443-XTG-D-0508  
TABLE 4: DNA036 COOLING CAPACITIES - 3 TON  
AIR ON EVAPORATOR COIL  
1,200 CFM  
TEMPERATURE  
OF AIR ON  
CONDENSER COIL  
900 CFM  
WB °F  
1,050 CFM  
WB °F  
1,350 CFM  
WB °F  
1,500 CFM  
WB °F  
WB °F  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
NET CAP.  
MBH  
36.7 34.6 31.9 30.3 37.9 35.7 32.9 31.3 39.1 36.9 34.0 32.3 39.4 37.1 34.2 32.5 39.6 37.4 34.4 32.7  
3.57 3.51 3.44 3.41 3.64 3.58 3.51 3.48 3.71 3.65 3.58 3.55 3.80 3.73 3.66 3.63 3.88 3.82 3.74 3.71  
TOTAL POWER  
INPUT kW  
86 19.8 25.2 29.9 30.3 23.0 28.7 32.0 31.3 26.1 32.1 34.0 32.3 24.8 31.0 34.2 32.5 23.5 29.9 34.4 32.7  
83 18.9 24.3 29.0 29.7 21.0 26.7 31.5 31.0 23.1 29.2 34.0 32.3 22.8 29.0 34.2 32.5 22.4 28.8 34.4 32.7  
80 18.0 23.4 28.1 28.8 19.1 24.8 29.8 30.5 20.1 26.2 31.5 32.3 20.7 27.0 32.4 32.5 21.3 27.7 33.3 32.7  
77 17.1 22.4 27.2 27.9 17.1 22.8 27.8 28.6 17.2 23.2 28.5 29.3 18.7 24.9 30.4 30.5 20.2 26.6 32.2 31.6  
74 16.1 21.5 26.2 26.9 15.2 20.9 25.9 26.6 14.2 20.2 25.5 26.3 16.7 22.9 28.3 28.4 19.1 25.5 31.1 30.5  
85 °F  
71  
68  
-
-
20.6 25.3 26.0  
19.7 24.4 25.1  
-
-
18.9 23.9 24.7  
17.0 22.0 22.7  
-
-
17.3 22.6 23.4  
14.3 19.6 20.4  
-
-
20.9 26.3 26.4  
18.8 24.3 24.4  
-
-
24.4 30.0 29.4  
23.3 28.9 28.3  
NET CAP.  
MBH  
36.9 34.1 31.4 31.2 37.3 34.5 31.8 31.5 37.7 34.9 32.1 31.9 38.3 35.5 32.6 32.4 39.0 36.1 33.2 32.9  
3.77 3.73 3.64 3.61 3.86 3.81 3.72 3.69 3.95 3.90 3.81 3.77 4.03 3.98 3.88 3.85 4.11 4.06 3.96 3.93  
TOTAL POWER  
INPUT kW  
86 23.8 29.2 31.4 31.2 25.1 30.8 31.8 31.5 26.5 32.4 32.1 31.9 25.1 31.2 32.6 32.4 23.6 30.0 33.2 32.9  
83 21.1 26.5 31.2 31.2 22.2 27.8 31.7 31.5 23.3 29.2 32.1 31.9 22.9 29.0 32.6 32.4 22.5 28.9 33.2 32.9  
80 18.4 23.8 28.5 29.3 19.2 24.9 29.8 30.6 20.0 26.0 31.1 31.9 20.7 26.9 32.1 32.4 21.4 27.8 33.2 32.9  
77 15.7 21.1 25.9 26.6 16.3 21.9 26.9 27.6 16.8 22.7 27.9 28.7 18.6 24.7 30.0 30.3 20.3 26.7 32.1 31.8  
74 13.0 18.5 23.2 23.9 13.3 19.0 23.9 24.7 13.6 19.5 24.7 25.5 16.4 22.5 27.8 28.1 19.2 25.6 31.0 30.7  
95 °F  
71  
68  
-
-
15.8 20.5 21.2  
13.1 17.8 18.5  
-
-
16.0 21.0 21.7  
13.1 18.0 18.8  
-
-
16.3 21.4 22.2  
13.1 18.2 19.0  
-
-
20.4 25.7 25.9  
18.2 23.5 23.8  
-
-
24.5 29.9 29.6  
23.4 28.8 28.5  
NET CAP.  
MBH  
34.9 32.6 30.7 29.6 35.3 32.9 31.0 29.9 35.6 33.2 31.3 30.2 36.1 33.6 31.7 30.6 36.5 34.0 32.1 30.9  
4.00 3.93 3.84 3.83 4.09 4.01 3.93 3.91 4.18 4.10 4.01 3.99 4.26 4.18 4.09 4.07 4.34 4.26 4.17 4.15  
TOTAL POWER  
INPUT kW  
86 21.1 27.2 29.8 28.8 22.4 28.7 30.6 29.5 23.7 30.3 31.3 30.2 23.2 30.1 31.7 30.6 22.8 29.8 32.1 30.9  
83 19.4 25.4 29.3 28.4 20.5 26.8 30.3 29.3 21.6 28.2 31.3 30.2 21.6 28.5 31.7 30.6 21.7 28.7 32.1 30.9  
80 17.7 23.7 27.6 27.0 18.6 24.9 29.0 28.4 19.5 26.1 30.4 29.8 20.1 26.9 31.2 30.4 20.6 27.7 32.1 30.9  
77 15.9 21.9 25.8 25.3 16.6 23.0 27.1 26.5 17.4 24.0 28.3 27.7 18.5 25.3 29.7 28.8 19.6 26.6 31.0 29.8  
74 14.2 20.2 24.1 23.5 14.7 21.0 25.1 24.6 15.3 21.9 26.2 25.6 16.9 23.7 28.1 27.2 18.5 25.5 29.9 28.8  
105 °F  
115 °F  
125 °F  
71  
68  
-
-
18.4 22.3 21.8  
16.7 20.6 20.0  
-
-
19.1 23.2 22.7  
17.2 21.3 20.7  
-
-
19.8 24.1 23.5  
17.7 22.0 21.4  
-
-
22.2 26.5 25.6  
20.6 24.9 24.0  
-
-
24.5 28.9 27.7  
23.4 27.8 26.7  
NET CAP.  
MBH  
33.0 31.0 30.0 28.0 33.3 31.3 30.3 28.2 33.5 31.6 30.6 28.5 33.8 31.8 30.8 28.7 34.0 32.0 31.0 28.9  
4.24 4.13 4.05 4.04 4.32 4.22 4.13 4.12 4.41 4.30 4.22 4.21 4.50 4.38 4.30 4.29 4.58 4.47 4.38 4.37  
TOTAL POWER  
INPUT kW  
86 18.5 25.1 28.2 26.4 19.7 26.7 29.4 27.4 20.9 28.2 30.6 28.5 21.4 28.9 30.8 28.7 21.9 29.6 31.0 28.9  
83 17.7 24.3 27.4 25.6 18.8 25.8 29.0 27.0 19.9 27.3 30.6 28.5 20.4 27.9 30.8 28.7 20.9 28.6 31.0 28.9  
80 16.9 23.5 26.6 24.8 17.9 24.9 28.1 26.2 18.9 26.3 29.7 27.7 19.4 26.9 30.3 28.3 19.9 27.6 31.0 28.9  
77 16.1 22.7 25.8 24.0 17.0 24.0 27.2 25.4 17.9 25.3 28.7 26.7 18.4 25.9 29.3 27.3 18.8 26.6 30.0 27.9  
74 15.3 21.9 24.9 23.2 16.1 23.1 26.4 24.5 17.0 24.3 27.8 25.8 17.4 24.9 28.3 26.3 17.8 25.5 28.9 26.8  
71  
68  
-
-
21.1 24.1 22.4  
20.3 23.3 21.6  
-
-
22.2 25.5 23.6  
21.3 24.6 22.7  
-
-
23.4 26.8 24.8  
22.4 25.8 23.8  
-
-
23.9 27.3 25.3  
22.9 26.3 24.3  
-
-
24.5 27.9 25.8  
23.5 26.9 24.8  
NET CAP.  
MBH  
31.0 29.4 29.3 26.4 31.2 29.7 29.6 26.6 31.4 29.9 29.8 26.8 31.5 29.9 29.8 26.8 31.5 30.0 29.9 26.9  
4.47 4.33 4.26 4.26 4.55 4.42 4.34 4.34 4.64 4.50 4.42 4.42 4.73 4.59 4.51 4.51 4.82 4.68 4.59 4.60  
TOTAL POWER  
INPUT kW  
86 15.9 23.1 26.6 24.0 17.0 24.6 28.2 25.4 18.1 26.1 29.8 26.8 19.6 27.8 29.8 26.8 21.1 29.5 29.9 26.9  
83 16.0 23.2 25.4 22.8 17.1 24.8 27.6 24.8 18.2 26.3 29.8 26.8 19.1 27.4 29.8 26.8 20.1 28.5 29.9 26.9  
80 16.2 23.3 25.6 22.5 17.3 24.9 27.3 24.1 18.4 26.5 29.0 25.6 18.7 27.0 29.5 26.2 19.1 27.5 29.9 26.9  
77 16.3 23.5 25.7 22.7 17.4 25.0 27.4 24.2 18.5 26.6 29.2 25.8 18.3 26.6 29.0 25.8 18.1 26.5 28.9 25.9  
74 16.4 23.6 25.8 22.8 17.6 25.2 27.6 24.4 18.7 26.8 29.3 25.9 17.9 26.1 28.6 25.4 17.1 25.5 27.9 24.9  
71  
68  
-
-
23.7 26.0 22.9  
23.9 26.1 23.1  
-
-
25.3 27.7 24.5  
25.5 27.9 24.7  
-
-
26.9 29.5 26.1  
27.1 29.6 26.2  
-
-
25.7 28.2 25.0  
25.3 27.8 24.6  
-
-
24.5 26.9 23.9  
23.5 25.9 22.9  
ALL SENSIBLE CAPACITY  
1. These capacities are net capacities (the indoor fan heat is deducted).  
Johnson Controls Unitary Products  
9
 
292443-XTG-D-0508  
TABLE 5: DNA042 COOLING CAPACITIES - 3-1/2 TON  
AIR ON EVAPORATOR COIL  
TEMPERATURE  
OF AIR ON  
CONDENSER COIL  
1,050 CFM  
WB °F  
1,225 CFM  
WB °F  
1,400 CFM  
WB °F  
1,575 CFM  
WB °F  
1,750 CFM  
WB °F  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
NET CAP.  
MBH  
44.5 40.8 37.6 36.5 46.0 42.2 38.8 37.7 47.5 43.6 40.1 38.9 48.9 44.9 41.3 40.1 50.3 46.2 42.5 41.2  
4.01 4.00 3.85 3.85 4.16 4.15 4.00 4.00 4.31 4.31 4.15 4.15 4.36 4.35 4.19 4.19 4.40 4.39 4.23 4.23  
TOTAL POWER  
INPUT kW  
86 23.6 29.7 35.1 35.9 27.6 34.2 37.6 37.4 31.6 38.6 40.1 38.9 31.0 38.5 41.3 40.1 30.5 38.4 42.5 41.2  
83 22.5 28.6 34.0 34.8 25.3 31.9 37.0 36.8 28.1 35.1 40.1 38.9 28.6 36.1 41.3 40.1 29.1 37.1 42.5 41.2  
80 21.4 27.5 32.9 33.7 23.0 29.6 35.4 36.2 24.6 31.7 37.9 38.8 26.2 33.7 40.2 40.0 27.8 35.7 42.5 41.2  
77 20.3 26.4 31.8 32.6 20.7 27.3 33.1 34.0 21.2 28.2 34.4 35.3 23.8 31.3 37.8 37.6 26.4 34.3 41.1 39.9  
74 19.2 25.4 30.7 31.5 18.5 25.1 30.8 31.7 17.7 24.7 30.9 31.8 21.4 28.9 35.3 35.2 25.0 33.0 39.7 38.5  
85 °F  
71  
68  
-
-
24.3 29.7 30.4  
23.2 28.6 29.4  
-
-
22.8 28.6 29.4  
20.5 26.3 27.1  
-
-
21.3 27.5 28.4  
17.8 24.0 24.9  
-
-
26.4 32.9 32.8  
24.0 30.5 30.3  
-
-
31.6 38.4 37.2  
30.2 37.0 35.8  
NET CAP.  
MBH  
41.5 38.0 34.6 35.0 43.2 39.6 36.0 36.4 44.9 41.1 37.3 37.8 46.1 42.2 38.3 38.8 47.2 43.2 39.3 39.8  
4.24 4.22 4.07 4.10 4.40 4.38 4.22 4.25 4.56 4.54 4.38 4.40 4.62 4.60 4.43 4.46 4.68 4.66 4.49 4.52  
TOTAL POWER  
INPUT kW  
86 26.5 32.7 34.6 35.0 29.0 35.7 36.0 36.4 31.4 38.7 37.3 37.8 30.3 38.0 38.3 38.8 29.2 37.3 39.3 39.8  
83 23.4 29.6 33.8 34.1 25.5 32.3 35.6 36.0 27.6 34.9 37.3 37.8 27.7 35.4 38.3 38.8 27.8 35.9 39.3 39.8  
80 20.3 26.5 30.7 31.0 22.1 28.8 33.4 33.8 23.9 31.2 36.1 36.5 25.2 32.9 37.7 38.2 26.5 34.6 39.3 39.8  
77 17.1 23.3 27.6 27.9 18.6 25.4 30.0 30.3 20.1 27.4 32.4 32.8 22.6 30.3 35.2 35.6 25.1 33.2 37.9 38.4  
74 14.0 20.2 24.4 24.7 15.2 21.9 26.5 26.9 16.3 23.7 28.6 29.0 20.0 27.7 32.6 33.0 23.7 31.8 36.6 37.1  
95 °F  
71  
68  
-
-
17.1 21.3 21.6  
13.9 18.1 18.5  
-
-
18.5 23.1 23.4  
15.0 19.6 20.0  
-
-
19.9 24.9 25.2  
16.1 21.1 21.5  
-
-
25.2 30.0 30.5  
22.6 27.5 27.9  
-
-
30.4 35.2 35.7  
29.1 33.8 34.3  
NET CAP.  
MBH  
38.7 34.7 32.2 33.0 40.3 36.1 33.5 34.3 41.8 37.5 34.8 35.6 42.8 38.4 35.6 36.5 43.8 39.2 36.5 37.3  
4.51 4.44 4.34 4.34 4.67 4.59 4.49 4.49 4.82 4.74 4.63 4.64 4.90 4.82 4.71 4.71 4.98 4.90 4.78 4.79  
TOTAL POWER  
INPUT kW  
86 23.6 29.4 31.7 31.8 25.7 32.0 33.3 33.7 27.8 34.6 34.8 35.6 28.0 35.1 35.6 36.4 28.1 35.7 36.5 37.3  
83 21.5 27.3 30.9 30.9 23.4 29.7 32.9 32.9 25.3 32.1 34.8 35.0 26.1 33.2 35.6 36.2 26.8 34.4 36.5 37.3  
80 19.5 25.3 28.9 28.8 21.2 27.5 31.4 31.3 22.9 29.7 33.8 33.8 24.2 31.3 35.2 35.5 25.5 33.0 36.5 37.3  
77 17.5 23.3 26.8 26.8 18.9 25.2 29.1 29.1 20.4 27.2 31.4 31.4 22.3 29.5 33.3 33.7 24.1 31.7 35.1 36.0  
74 15.4 21.2 24.8 24.7 16.7 23.0 26.9 26.8 18.0 24.8 28.9 28.9 20.4 27.6 31.4 31.8 22.8 30.4 33.8 34.6  
105 °F  
115 °F  
125 °F  
71  
68  
-
-
19.2 22.7 22.7  
17.1 20.7 20.7  
-
-
20.7 24.6 24.6  
18.5 22.4 22.3  
-
-
22.3 26.5 26.5  
19.9 24.0 24.0  
-
-
25.7 29.5 29.9  
23.8 27.6 28.0  
-
-
29.0 32.5 33.3  
27.7 31.1 32.0  
NET CAP.  
MBH  
35.9 31.3 29.9 30.9 37.3 32.6 31.1 32.2 38.8 33.9 32.3 33.4 39.6 34.5 33.0 34.1 40.3 34.2 33.6 34.8  
4.78 4.66 4.61 4.59 4.93 4.80 4.75 4.73 5.08 4.95 4.89 4.87 5.18 5.04 4.99 4.97 5.27 5.14 5.08 5.06  
TOTAL POWER  
INPUT kW  
86 20.6 26.0 28.9 28.5 22.4 28.2 30.6 31.0 24.2 30.4 32.3 33.4 25.6 32.3 33.0 34.1 27.1 34.1 33.6 34.8  
83 19.7 25.1 28.0 27.6 21.4 27.2 30.1 29.9 23.0 29.3 32.3 32.2 24.4 31.0 33.0 33.5 25.8 32.8 33.6 34.8  
80 18.7 24.1 27.0 26.6 20.3 26.1 29.3 28.9 21.9 28.2 31.6 31.1 23.2 29.8 32.6 32.9 24.5 31.5 33.6 34.8  
77 17.8 23.2 26.1 25.7 19.3 25.1 28.2 27.8 20.7 27.0 30.4 30.0 22.0 28.6 31.4 31.7 23.2 30.2 32.3 33.5  
74 16.9 22.2 25.1 24.8 18.2 24.0 27.2 29.8 19.6 25.9 29.3 28.8 20.8 27.4 30.1 30.5 21.9 28.9 31.0 32.2  
71  
68  
-
-
21.3 24.2 23.8  
20.3 23.2 22.9  
-
-
23.0 26.2 25.7  
22.0 25.1 24.7  
-
-
24.7 28.1 27.7  
23.6 27.0 26.5  
-
-
26.2 28.9 29.3  
25.0 27.7 28.1  
-
-
27.6 29.7 30.9  
26.4 28.5 29.6  
NET CAP.  
MBH  
33.0 27.9 27.5 28.9 34.4 29.1 28.7 30.1 35.8 30.3 29.8 31.3 36.3 30.7 30.3 31.7 36.9 31.2 30.7 32.2  
5.05 4.88 4.87 4.83 5.19 5.02 5.01 4.97 5.34 5.16 5.15 5.11 5.45 5.27 5.26 5.22 5.57 5.38 5.37 5.33  
TOTAL POWER  
INPUT kW  
86 17.7 22.6 26.1 25.3 19.1 24.5 27.9 28.2 20.6 26.3 29.8 31.2 23.3 29.4 30.3 31.7 26.0 32.5 30.7 32.2  
83 17.8 22.8 25.0 24.3 19.3 24.6 27.4 26.9 20.7 26.5 29.8 29.5 22.7 28.8 30.3 30.8 24.8 31.2 30.7 32.2  
80 18.0 22.9 25.2 24.4 19.4 24.8 27.2 26.4 20.9 26.6 29.3 28.4 22.2 28.3 30.0 30.3 23.5 30.0 30.7 32.2  
77 18.1 23.1 25.3 24.6 19.6 24.9 27.4 26.6 21.1 26.8 29.4 28.6 21.7 27.8 29.5 29.8 22.3 28.7 29.5 31.0  
74 18.3 23.2 25.5 24.8 19.8 25.1 27.5 26.7 21.2 27.0 29.6 28.7 21.1 27.2 28.9 29.2 21.0 27.5 28.2 29.7  
71  
68  
-
-
23.4 25.6 24.9  
23.5 25.8 25.1  
-
-
25.3 27.7 26.9  
25.4 27.9 27.1  
-
-
27.2 29.8 28.9  
27.3 29.9 29.1  
-
-
26.7 28.4 28.7  
26.2 27.9 28.2  
-
-
26.2 27.0 28.5  
25.0 25.8 27.2  
ALL SENSIBLE CAPACITY  
1. These capacities are net capacities (the indoor fan heat is deducted).  
10  
Johnson Controls Unitary Products  
 
292443-XTG-D-0508  
TABLE 6: DNA048 COOLING CAPACITIES - 4 TON  
AIR ON EVAPORATOR COIL  
1,600 CFM  
TEMPERATURE  
OF AIR ON  
CONDENSER COIL  
1,200 CFM  
WB °F  
1,400 CFM  
WB °F  
1,800 CFM  
WB °F  
2,000 CFM  
WB °F  
WB °F  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
NET CAP.  
MBH  
48.5 45.0 41.0 41.6 49.9 46.3 42.2 42.8 51.3 47.6 43.4 44.0 52.4 48.7 44.4 44.9 53.5 49.7 45.3 45.9  
3.99 3.93 3.87 3.86 4.01 3.95 3.88 3.88 4.02 3.96 3.90 3.89 4.04 3.97 3.91 3.91 4.05 3.99 3.92 3.92  
TOTAL POWER  
INPUT kW  
86 28.9 36.8 41.0 41.6 31.9 40.5 42.2 42.8 34.9 44.1 43.4 44.0 38.0 46.9 44.4 44.9 41.0 49.7 45.3 45.9  
83 25.5 33.4 40.3 41.2 27.8 36.4 41.9 42.6 30.2 39.4 43.4 44.0 32.7 42.5 44.4 44.9 35.1 45.6 45.3 45.9  
80 22.0 30.0 36.9 37.8 23.8 32.4 39.8 40.9 25.6 34.8 42.8 43.9 27.3 37.2 44.1 44.9 29.1 39.6 45.3 45.9  
77 18.6 26.5 33.4 34.4 19.8 28.3 35.8 36.8 20.9 30.1 38.1 39.2 22.0 31.9 38.7 39.6 23.1 33.6 39.4 40.0  
74 15.2 23.1 30.0 31.0 15.7 24.3 31.7 32.8 16.2 25.4 33.5 34.6 16.7 26.6 33.4 34.3 17.2 27.7 33.4 34.0  
85 °F  
71  
68  
-
-
19.7 26.6 27.6  
16.3 23.2 24.1  
-
-
20.2 27.7 23.7  
16.2 23.7 24.7  
-
-
20.8 28.8 29.9  
16.1 24.1 25.2  
-
-
21.2 28.1 29.0  
15.9 22.8 23.7  
-
-
21.7 27.5 28.0  
15.7 21.5 22.1  
NET CAP.  
MBH  
43.5 41.9 36.3 36.9 46.1 44.4 38.6 39.1 48.8 47.0 40.8 41.4 48.6 46.8 40.6 41.2 48.3 46.5 40.4 40.9  
4.44 4.34 4.32 4.32 4.44 4.34 4.32 4.32 4.43 4.33 4.31 4.47 4.37 4.37 4.35 4.35 4.50 4.41 4.38 4.39  
TOTAL POWER  
INPUT kW  
86 27.2 35.6 36.3 36.9 30.7 40.1 38.6 39.1 34.3 44.7 40.8 41.4 36.8 45.6 40.6 41.2 39.2 46.5 40.4 40.9  
83 23.7 32.2 36.3 36.9 26.7 36.1 38.6 39.1 29.7 40.0 40.8 41.4 31.5 42.3 40.6 41.2 33.3 44.6 40.4 40.9  
80 20.3 28.8 33.1 33.6 22.7 32.1 36.9 37.4 25.0 35.4 40.7 41.3 26.2 37.0 40.5 41.1 27.3 38.6 40.4 40.9  
77 16.9 25.3 29.7 30.2 18.6 28.0 32.9 33.4 20.3 30.7 36.1 36.6 20.8 31.7 35.2 35.8 21.3 32.7 34.4 35.0  
74 13.5 21.9 26.3 26.7 14.6 24.0 28.8 29.3 15.7 26.0 31.4 32.0 15.5 26.4 29.9 30.5 15.4 26.7 28.4 29.0  
95 °F  
71  
68  
-
-
18.5 22.8 23.3  
15.1 19.4 19.5  
-
-
19.9 24.8 25.3  
15.9 20.7 21.3  
-
-
21.4 26.7 27.3  
16.7 22.1 22.6  
-
-
21.1 24.6 25.2  
15.7 19.3 19.9  
-
-
20.8 22.5 23.0  
14.8 16.5 17.1  
NET CAP.  
MBH  
42.2 39.2 35.7 36.0 44.1 40.9 37.2 37.5 45.9 42.6 38.8 39.1 46.4 43.1 39.2 39.5 47.0 43.6 39.7 40.0  
4.94 4.85 4.81 4.81 4.95 4.85 4.81 4.82 4.95 4.86 4.82 4.83 4.98 4.89 4.84 4.85 5.00 4.91 4.87 4.89  
TOTAL POWER  
INPUT kW  
86 26.7 34.8 35.7 36.0 30.1 38.1 37.2 37.5 33.4 41.5 38.8 39.1 36.1 42.5 39.2 39.5 38.8 43.6 39.7 40.0  
83 23.3 31.3 35.3 35.6 26.0 34.9 37.0 37.3 28.7 38.4 38.8 39.1 30.8 40.5 39.2 39.5 32.8 42.6 39.7 40.0  
80 19.9 27.9 32.0 32.2 22.0 30.8 35.3 35.6 24.1 33.8 38.7 39.0 25.5 35.7 39.2 39.5 26.9 37.7 39.7 40.0  
77 16.5 24.5 28.6 28.8 17.9 26.8 31.3 31.6 19.4 29.1 34.0 34.3 20.2 30.4 33.9 34.2 20.9 31.7 33.7 34.0  
74 13.0 21.1 25.1 25.4 13.9 22.8 27.2 27.5 14.7 24.4 29.4 29.7 14.8 25.1 28.6 28.9 14.9 25.8 27.8 28.1  
105 °F  
115 °F  
125 °F  
71  
68  
-
-
17.7 21.7 22.0  
14.2 18.3 18.5  
-
-
18.7 23.2 23.5  
14.7 19.2 19.4  
-
-
19.8 24.7 25.0  
15.1 20.0 20.3  
-
-
19.8 23.3 23.6  
14.5 17.9 18.3  
-
-
19.8 21.8 22.1  
13.9 15.9 16.2  
NET CAP.  
MBH  
41.0 36.5 35.0 35.1 42.0 37.3 35.9 35.9 43.0 38.2 36.7 36.8 44.3 39.4 37.9 37.9 45.7 40.6 39.0 39.1  
5.44 5.35 5.29 5.30 5.46 5.37 5.31 5.32 5.47 5.39 5.33 5.34 5.49 5.40 5.34 5.35 5.50 5.42 5.35 5.37  
TOTAL POWER  
INPUT kW  
86 26.3 33.9 35.0 35.1 29.4 36.1 35.9 35.9 32.5 38.2 36.7 36.8 35.4 39.4 37.9 37.9 38.4 40.6 39.0 39.1  
83 22.9 30.5 34.3 34.3 25.3 33.7 35.5 35.5 27.8 36.9 36.7 36.8 30.1 38.7 37.9 37.9 32.4 40.6 39.0 39.1  
80 19.5 27.1 30.8 30.9 21.3 29.6 33.7 33.6 23.1 32.1 36.7 36.7 24.8 34.9 37.8 37.9 26.4 36.8 39.0 39.1  
77 16.0 23.7 27.4 27.5 17.2 25.6 29.7 29.8 18.5 27.5 32.0 32.0 19.5 29.2 32.5 32.6 20.5 30.8 33.1 33.1  
74 12.6 20.6 24.0 24.0 13.2 21.5 25.7 25.7 13.8 22.9 27.3 27.4 14.2 23.9 27.2 27.3 14.5 24.9 27.1 27.2  
71  
68  
-
-
16.8 20.6 20.6  
13.4 17.2 17.2  
-
-
17.5 21.6 21.7  
13.5 17.6 17.6  
-
-
18.2 22.7 22.7  
13.5 18.0 18.1  
-
-
18.5 21.9 22.0  
13.2 16.6 16.6  
-
-
18.9 21.1 21.2  
12.9 15.2 15.2  
NET CAP.  
MBH  
39.7 33.7 34.3 34.2 39.9 33.6 34.5 34.3 40.1 33.9 34.7 34.5 42.2 35.8 36.5 36.3 44.4 37.7 38.4 38.2  
5.90 5.90 5.80 5.80 6.00 5.90 5.80 5.80 6.00 5.90 5.80 5.90 6.00 5.90 5.80 5.90 6.00 5.90 5.80 5.90  
TOTAL POWER  
INPUT kW  
86 25.9 33.1 34.3 34.2 28.7 34.0 34.5 34.3 31.5 35.0 34.7 34.5 34.7 36.4 36.5 36.3 37.9 37.7 38.4 38.2  
83 22.4 29.7 33.2 33.0 24.7 32.5 34.0 33.8 26.9 35.3 34.7 34.5 29.4 37.0 36.5 36.3 32.0 38.7 38.4 38.2  
80 19.0 26.2 29.7 29.5 20.6 28.4 32.2 32.0 22.2 30.6 34.6 34.4 24.1 33.2 36.5 36.3 26.0 35.9 38.4 38.2  
77 15.6 22.8 26.8 26.1 16.6 24.4 28.1 27.9 17.5 25.9 30.0 29.8 18.8 27.9 31.2 31.0 20.0 29.9 32.4 32.2  
74 12.2 19.4 22.9 22.7 12.5 20.3 24.1 23.9 12.9 21.3 25.3 25.1 13.5 22.6 25.9 25.7 14.1 23.9 26.4 26.2  
71  
68  
-
-
16.0 19.4 19.3  
12.6 16.6 15.9  
-
-
16.3 20.0 19.9  
12.2 16.0 15.8  
-
-
16.6 20.6 20.4  
11.9 16.0 15.8  
-
-
17.3 20.5 20.4  
12.0 15.2 15.0  
-
-
18.0 20.5 20.3  
12.0 14.5 14.3  
ALL SENSIBLE CAPACITY  
1. These capacities are net capacities (the indoor fan heat is deducted).  
Johnson Controls Unitary Products  
11  
 
292443-XTG-D-0508  
TABLE 7: DNA060 COOLING CAPACITIES - 5 TON  
AIR ON EVAPORATOR COIL  
2,000 CFM  
TEMPERATURE  
OF AIR ON  
CONDENSER COIL  
1,500 CFM  
WB °F  
1,750 CFM  
WB °F  
2,250 CFM  
WB °F  
2,500 CFM  
WB °F  
WB °F  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
72  
67  
62  
57  
NET CAP.  
MBH  
60.3 56.2 52.0 51.1 62.4 58.1 53.8 52.9 64.4 60.0 55.5 54.6 65.4 60.9 56.4 55.5 66.5 61.8 57.3 56.3  
5.67 5.58 5.48 5.50 5.80 5.71 5.61 5.63 5.93 5.83 5.73 5.75 6.11 6.01 5.91 5.93 6.30 6.20 6.09 6.11  
TOTAL POWER  
INPUT kW  
86 39.5 47.7 52.0 51.1 43.5 52.3 53.8 52.9 47.5 56.9 55.5 54.6 50.9 59.4 56.4 55.5 54.3 61.8 57.3 56.3  
83 35.2 43.4 50.6 50.9 38.4 47.2 53.1 52.7 41.6 51.0 55.5 54.6 44.3 54.1 56.4 55.5 46.9 57.2 57.3 56.3  
80 31.0 39.1 46.4 46.6 33.4 42.2 50.0 50.2 35.8 45.2 53.6 53.9 37.6 47.5 55.4 55.1 39.4 49.8 57.3 56.3  
77 26.7 34.8 42.1 42.3 28.3 37.1 44.9 45.2 30.0 39.4 47.8 48.1 31.0 40.9 48.8 48.5 32.0 42.3 49.8 48.9  
74 22.4 30.5 37.8 38.0 23.3 32.0 39.9 40.1 24.2 33.6 42.0 42.2 24.3 34.2 42.2 41.8 24.5 34.9 42.4 41.4  
85 °F  
71  
68  
-
-
26.3 33.5 33.8  
22.0 29.3 29.5  
-
-
27.0 34.8 35.1  
21.9 29.8 30.0  
-
-
27.7 36.1 36.4  
21.9 30.3 30.6  
-
-
27.6 35.5 35.2 17.1 27.4 34.9 34.0  
20.9 28.9 28.5 9.6 20.0 27.5 26.5  
NET CAP.  
MBH  
57.6 53.0 49.0 48.5 59.5 54.7 50.7 50.1 61.5 56.5 52.3 51.7 62.4 57.3 53.1 52.4 63.3 58.1 53.9 53.2  
6.14 6.11 5.96 6.01 6.30 6.27 6.11 6.16 6.45 6.42 6.26 6.32 6.62 6.59 6.43 6.49 6.80 6.76 6.60 6.65  
TOTAL POWER  
INPUT kW  
86 37.6 46.8 49.0 48.5 41.5 51.4 50.7 50.1 45.3 56.0 52.3 51.7 48.6 57.1 53.1 52.4 51.8 58.1 53.9 53.2  
83 33.3 42.5 48.6 48.2 36.4 46.4 50.5 50.0 39.5 50.2 52.3 51.7 41.9 53.1 53.1 52.4 44.4 56.1 53.9 53.2  
80 29.1 38.3 44.4 43.9 31.4 41.3 47.9 47.4 33.7 44.3 51.4 50.9 35.3 46.5 52.6 52.1 36.9 48.6 53.9 53.2  
77 24.8 34.0 40.1 39.7 26.3 36.2 42.8 42.4 27.8 38.5 45.5 45.1 28.7 39.8 46.0 45.4 29.5 41.2 46.4 45.7  
74 20.5 29.7 35.8 35.4 21.3 31.2 37.8 37.3 22.0 32.7 39.7 39.2 22.0 33.2 39.3 38.8 22.0 33.7 38.9 38.3  
95 °F  
71  
68  
-
-
25.4 31.5 31.1  
21.2 27.2 26.8  
-
-
26.1 32.7 32.3  
21.1 27.6 27.2  
-
-
26.8 33.9 33.4  
21.0 28.0 27.6  
-
-
26.6 32.7 32.1  
19.9 26.0 25.5  
-
-
26.3 31.5 30.8  
18.8 24.0 23.4  
NET CAP.  
MBH  
53.0 48.8 45.0 42.7 55.0 50.7 46.8 44.3 57.1 52.5 48.5 45.9 57.6 53.1 49.0 46.4 58.2 53.6 49.5 46.9  
6.85 6.74 6.64 6.64 6.99 6.88 6.78 6.78 7.14 7.03 6.93 6.92 7.34 7.22 7.12 7.12 7.54 7.42 7.31 7.31  
TOTAL POWER  
INPUT kW  
86 36.1 45.1 45.0 42.7 39.9 48.7 46.8 44.3 43.7 52.3 48.5 45.9 46.9 53.0 49.0 46.4 50.1 53.6 49.5 46.9  
83 31.8 40.8 44.8 42.6 34.9 44.6 46.7 44.2 37.9 48.4 48.5 45.9 40.3 50.5 49.0 46.4 42.6 52.6 49.5 46.9  
80 27.6 36.5 41.5 39.4 29.8 39.5 44.9 42.6 32.1 42.5 48.3 45.8 33.6 44.6 48.9 46.3 35.2 46.6 49.5 46.9  
77 23.3 32.2 37.2 35.1 24.8 34.5 39.8 37.5 26.3 36.7 42.4 40.0 27.0 37.9 42.2 39.7 27.7 39.2 42.0 39.4  
74 19.0 28.0 32.9 30.8 19.7 29.4 34.8 32.5 20.4 30.9 36.6 34.2 20.3 31.3 35.6 33.1 20.3 31.7 34.6 32.0  
105 °F  
115 °F  
125 °F  
71  
68  
-
-
23.7 28.6 26.5  
19.4 24.4 22.3  
-
-
24.4 29.7 27.4  
19.3 24.6 22.4  
-
-
25.0 30.8 28.3  
19.2 24.9 22.5  
-
-
24.6 29.0 26.4  
18.0 22.3 19.8  
-
-
24.2 27.1 24.5  
16.8 19.7 17.1  
NET CAP.  
MBH  
48.4 44.7 41.0 36.9 50.5 46.6 42.8 38.5 52.6 48.6 44.6 40.1 52.9 48.8 44.9 40.3 53.2 49.1 45.1 40.5  
7.56 7.37 7.33 7.27 7.69 7.50 7.46 7.40 7.82 7.63 7.59 7.53 8.05 7.85 7.81 7.75 8.28 8.08 8.03 7.97  
TOTAL POWER  
INPUT kW  
86 34.6 43.3 41.0 36.9 38.4 45.9 42.8 38.5 42.2 48.6 44.6 40.1 45.2 48.8 44.9 40.3 48.3 49.1 45.1 40.5  
83 30.3 39.1 41.0 36.9 33.3 42.8 42.8 38.5 36.3 46.5 44.6 40.1 38.6 47.8 44.9 40.3 40.8 49.1 45.1 40.5  
80 26.1 34.8 38.6 34.8 28.3 37.7 41.9 37.8 30.5 40.7 45.2 40.7 31.9 42.6 45.1 40.6 33.4 44.6 45.1 40.5  
77 21.8 30.5 34.3 30.5 23.2 32.7 36.8 32.7 24.7 34.9 39.3 34.9 25.3 36.0 38.5 34.0 25.9 37.1 37.7 33.1  
74 17.5 26.2 30.0 26.3 18.2 27.6 31.8 27.7 18.8 29.0 33.5 29.1 18.7 29.4 31.9 27.4 18.5 29.7 30.2 25.6  
71  
68  
-
-
22.0 25.8 22.0  
17.7 21.5 17.7  
-
-
22.6 26.7 22.6  
17.5 21.7 17.6  
-
-
23.2 27.7 23.2  
17.4 21.8 17.4  
-
-
22.7 25.2 20.7  
16.1 18.6 14.1  
-
-
22.2 22.8 18.2  
14.8 15.3 10.7  
NET CAP.  
MBH  
43.8 40.5 37.1 31.1 46.0 42.6 38.9 32.7 48.2 44.6 40.7 34.3 48.2 44.6 40.8 34.2 48.2 44.6 40.8 34.2  
8.30 8.00 8.00 7.90 8.40 8.10 8.10 8.00 8.50 8.20 8.20 8.10 8.80 8.50 8.50 8.40 9.00 8.70 8.70 8.60  
TOTAL POWER  
INPUT kW  
86 33.1 41.6 37.1 31.1 36.8 43.2 38.9 32.7 40.6 44.8 40.7 34.3 43.5 44.7 40.8 34.2 46.5 44.6 40.8 34.2  
83 28.8 37.3 37.3 31.2 31.8 41.0 39.0 32.7 34.7 44.7 40.7 34.3 36.9 45.2 40.8 34.2 39.1 45.6 40.8 34.2  
80 24.5 33.0 35.7 30.2 26.7 36.0 38.9 32.9 28.9 38.9 42.0 35.6 30.3 40.7 41.4 34.9 31.6 42.5 40.8 34.2  
77 20.3 28.8 31.4 26.0 21.7 30.9 33.8 27.9 23.1 33.1 36.2 29.8 23.6 34.1 34.8 28.3 24.2 35.1 33.3 26.8  
74 16.0 24.5 27.1 21.7 16.6 25.9 28.8 22.8 17.2 27.2 30.4 24.0 17.0 27.4 28.1 21.6 16.7 27.6 25.9 19.3  
71  
68  
-
-
20.2 22.9 17.4  
15.9 18.6 13.1  
-
-
20.8 23.7 17.8  
15.8 18.7 12.7  
-
-
21.4 24.6 18.2  
15.6 18.7 12.3  
-
-
20.8 21.5 15.0  
14.2 14.8 8.2  
-
-
20.2 18.4 11.9  
12.7 10.9 4.4  
ALL SENSIBLE CAPACITY  
1. These capacities are net capacities (the indoor fan heat is deducted).  
12  
Johnson Controls Unitary Products  
 
292443-XTG-D-0508  
1
TABLE 8: SIDE SUPPLY AIR BLOWER PERFORMANCE  
EXTERNAL STAIC PRESSURE - IWG  
.50 .60 .70  
.10  
.20  
.30  
.40  
.80  
.90  
1.00  
1.10  
MODEL # MTR  
DNA  
SPD  
HI  
-
-
-
-
1238 504 1165 484 1075 463 984 443 894 422 751 390  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
030  
036  
MED 994 333 947 321 901 309 854 297 774 280  
-
-
-
-
-
-
-
-
-
-
-
-
LOW  
HI  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1465 712 1390 685 1315 657 1204 623 1093 588 982 554  
MED 1432 650 1381 628 1330 605 1279 583 1210 556 1140 529 1071 502 977 477  
LOW 1191 527 1149 510 1107 494 1065 477 1009 459 952 441  
HI  
MED 1432 650 1381 628 1330 605 1279 583 1210 556 1140 529  
LOW 1191 527 1149 510 1107 494 1065 477  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1681 797 1610 768 1540 740 1465 712 1390 685 1315 657 1204 623 1093 588  
042  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HI  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1908 1023 1832 982 1737 938 1656 889 1348 789 1252 754  
048,060  
MED  
LOW  
1773 894 1726 869 1674 852 1613 832 1339 731  
-
-
-
-
1672 841 1610 804 1542 773  
-
-
-
-
-
-
1. Above data includes allowances for a dry evaporator coil, gas heat exchanger and no filters. For additional pressure drops, refer to  
1
TABLE 9: BOTTOM SUPPLY AIR BLOWER PERFORMANCE  
EXTERNAL STATIC PRESSURE - IWG  
.10  
.20  
.30  
.40  
.50  
.60  
.70  
.80  
.90  
1.00  
1.10  
MODEL # MTR  
DNA  
SPD  
HI  
-
-
-
-
1115 454 1049 436  
967 417 886 398 805 380 676 351  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
030  
036  
042  
MED 895 300 853 289 811 278 769  
267  
697 252  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
LOW  
HI  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1458 688 1377 663 1295 639 1147 600 999 561  
MED 1482 628 1428 613 1374 599 1320 584 1242 556 1163 528 1085 500 961 474  
LOW 1239 510 1184 496 1130 481 1075 467 998 448 922 428  
HI 1687 763 1614 737 1540 712 1458 688 1377 663 1295 639 1147 600  
MED 1482 628 1428 613 1374 599 1320 584 1242 556 1163 528 1085 500  
LOW 1239 510 1184 496 1130 481 1075 467  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HI  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1928 1032 1844 994 1636 923 1515 888 1441 849  
048,060 MED  
LOW  
1805 837 1693 859 1580 819 1473 788  
-
-
-
-
1725 850 1660 807 1557 776 1428 728  
-
-
1. Above data includes allowances for a dry evaporator coil, gas heat exchanger and no filters. For additional pressure drops, refer  
to Tables 10 and 11.  
Johnson Controls Unitary Products  
13  
   
292443-XTG-D-0508  
1
TABLE 10: ADDITIONAL STATIC PRESSURE RESISTANCE 2-1/2 - 3-1/2 TON (DNA030 - 042)  
RESISTANCE, IWG  
DESCRIPTION  
CFM  
500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000  
WET EVAPORATOR COIL  
.01 .01 .01 .02 .03  
.00 .00 .00 .01 .01  
.01 .02 .04 .06 .08  
.04  
.01  
.10  
.05  
.01  
.13  
.06  
.02  
.16  
.07  
.03  
.17  
.08  
.04  
.18  
.09  
.05  
.19  
.09  
.06  
.20  
-
-
-
-
-
-
-
-
-
-
-
-
2
ECONOMIZER  
FILTER FRAME KIT  
1. Deduct these resistance values from the available external static pressure shown in Tables 8 and 9.  
2. The pressure through the economizer is greater for 100% outdoor air then for 100% return air. If the resistance of the return air  
duct system is less then 0.25 IWG, the unit will deliver less CFM during full economizer operation.  
1
TABLE 11: ADDITIONAL STATIC PRESSURE RESISTANCE 4 - 5 TON (DNA048 - 060)  
RESISTANCE, IWG  
DESCRIPTION  
CFM  
500 600 700 800 900 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000  
WET EVAPORATOR COIL  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
.03  
.02  
.04  
.04  
.02  
.05  
.05  
.03  
.05  
.06  
.03  
.06  
.07  
.04  
.07  
.07  
.04  
.08  
.08  
.04  
.09  
.09  
.05  
.10  
.09  
.05  
.11  
2
ECONOMIZER  
FILTER FRAME KIT  
1. Deduct these resistance values from the available external static pressure shown in Table 8 and 9.  
2. The pressure through the economizer is greater for 100% outdoor air then for 100% return air. If the resistance of the return air duct  
system is less then 0.25 IWG, the unit will deliver less CFM during full economizer operation.  
NOTE:  
HEAT ANTICIPATOR  
SHOULD BE SET AT 0.35  
AMPS FOR ALL MODELS.  
THERMOSTAT  
UNIT TERMINAL STRIP  
** = Minimum wire size of 18 AWG  
wire should be used for all  
field installed 24 volt wire.  
**  
R
R
G
Y
G
Y
24 VOLT  
TRANSFORMER  
W
C
W
C
PROGRAMMABLE  
THERMOSTAT ONLY  
FIGURE 3 - TYPICAL FIELD CONTROL WIRING DIAGRAM  
14  
Johnson Controls Unitary Products  
     
292443-XTG-D-0508  
CONTACTOR  
FIELD-SUPPLIED  
DISCONNECT  
SINGLE  
PHASE  
POWER  
SUPPLY  
REFER TO ELECTRICAL  
DATA TABLES TO SIZE  
THE DISCONNECT  
GROUND  
LUG  
CONTACTOR  
FIELD-SUPPLIED  
DISCONNECT  
THREE  
PHASE  
POWER  
SUPPLY  
GROUND  
LUG  
REFER TO ELECTRICAL  
DATA TABLES TO SIZE  
THE DISCONNECT  
FIGURE 4 - TYPICAL FIELD POWER WIRING DIAGRAM  
TABLE 12: ELECTRICAL DATA  
VOLTAGE  
SUPPLY  
AIR  
BLOWER  
MOTOR AMPACITY  
FLA  
MAX.  
HACR  
BREAKER POWER  
MAX.  
FUSE  
COND.  
FAN  
MOTOR,  
FLA  
COMPRESSOR  
1
MINIMUM  
CIRCUIT  
UNIT  
LIMITATIONS  
MODEL  
DNA  
POWER  
SUPPLY  
TRANSFORMER  
SIZE (VA)  
SIZE,  
SIZE,  
FACTOR  
2
MIN.  
MAX.  
RLA  
LRA  
AMPS  
AMPS  
030  
036  
036  
036  
042  
042  
042  
048  
048  
048  
060  
060  
060  
208/230-1-60  
208/230-1-60  
208/230-3-60  
460-3-60  
187  
187  
187  
414  
187  
187  
414  
187  
187  
414  
187  
187  
414  
253  
253  
253  
504  
253  
253  
504  
253  
253  
504  
253  
253  
504  
14.7  
17.3  
10.9  
5.8  
73  
94  
1.1  
1.1  
1.1  
0.6  
1.1  
1.1  
0.6  
1.3  
1.3  
0.7  
1.3  
1.3  
0.7  
2.2  
3.5  
3.5  
1.8  
3.5  
3.5  
1.8  
7
21.7  
26.2  
18.2  
9.6  
30  
35  
25  
15  
30  
25  
15  
50  
35  
20  
60  
40  
20  
30  
35  
25  
15  
30  
25  
15  
50  
35  
20  
60  
40  
20  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
40  
40  
75  
75  
40  
75  
75  
40  
75  
75  
40  
75  
75  
78  
40  
208/230-1-60  
208/230-3-60  
460-3-60  
15.4  
11.5  
5.8  
86  
23.9  
19  
88  
42  
9.7  
208/230-1-60  
208/230-3-60  
460-3-60  
24.4  
14.1  
7.1  
140  
105  
55  
38.8  
25.9  
13.1  
44.4  
29.5  
15.4  
7
3.5  
7
208/230-1-60  
208/230-3-60  
460-3-60  
28.9  
15.5  
8.9  
175  
125  
66.5  
7
3.5  
1. Utilization range “A” in accordance with ARI Standard 110.  
2. Dual element, time delay type.  
Johnson Controls Unitary Products  
15  
   
292443-XTG-D-0508  
VENT AIR OUTLET HOOD  
BLOWER SERVICE  
ACCESS COMPARTMENT  
PANEL  
CONDENSER COIL  
GAS SUPPLY 1-1/4" DIA.  
HOLE (1/2" NPTI  
CONNECTION)  
UNIT CONDENSATE  
CONNECTION 3/4" NPTI  
(TRAP RECOMMENDED)  
A
2-3/8  
B
HIGH VOLTAGE  
CONN. 1-3/8" DIA.  
KNOCKOUT  
3-3/4  
HIGH VOLTAGE  
CONN. 7/8" DIA.  
KNOCKOUT  
REFRIGERANT  
CONNECTIONS  
2-1/2  
COMBUSTION AIR  
INLET LOUVERS  
GAS SUPPLY 1-1/4" DIA.  
KNOCKOUT (1/2" NPTI  
CONNECTION)  
FRONT  
LOW VOLTAGE CONN.  
1-3/8" DIA. KNOCKOUT  
X 7/8" HOLE  
5-3/8  
2-5/8  
1-1/2  
GAS/ELECTRIC CONTROL  
SERVICE ACCESS  
COMPARTMENT PANEL  
11  
49-1/8  
12-3/4  
47-1/4  
(OVERALL)  
(OVERALL)  
3-1/3  
FIGURE 5 - UNIT DIMENSIONS - FRONT  
TABLE 13: UNIT DIMENSIONS FRONT  
1 2  
TABLE 14: UNIT MINIMUM CLEARANCES  
DIMENSION  
UNIT SIZE  
CLEARANCES  
“A”  
“B”  
FRONT  
REAR  
36”  
0”  
030 thru 042  
048 and 060  
33-1/2  
41-1/2  
18-1/4  
23-1/8  
LEFT SIDE (Filter-Access)  
RIGHT SIDE  
24”  
12”  
0”  
3
BELOW UNIT  
4
36” (For Condenser Air Discharge  
ABOVE UNIT  
1. A 1” clearance must be provided between any combus-  
tible material and the supply air ductwork.  
2. The products of combustion must not be allowed to  
accumulate within a confined space and recirculate.  
3. Units may be installed on combustible floors made from  
wood or class A, B, or C roof covering material.  
4. Units must be installed outdoors. Overhanging struc-  
tures or shrubs should not obstruct condenser air dis-  
charge outlet.  
16  
Johnson Controls Unitary Products  
     
292443-XTG-D-0508  
1
9
-
1
/
4
1
1
-
7
/
8
H
C
K
I
O
G
H
V
O
L
T
A
G
E
8
-
7
/
8
N
N
.
1
-
3
/
3
2
"
D
I
A
.
F
R
O
N
T
N
O
C
K
O
U
T
G
K
C
A
S
S
U
P
P
L
Y
1
-
5
/
8
"
D
I
A
.
N
O
C
K
O
U
T
T
(
1
/
2
"
N
P
T
I
O
N
N
E
C
I
O
N
)
L
1
O
/
W
V
O
L
T
A
G
E
C
O
N
N
.
8
"
D
I
A
.
K
N
O
C
K
O
U
T
4
-
5
/
8
C
D
O
R
N
D
E
N
S
A
T
E
A
I
N
3
/
4
"
'
N
P
T
I
2
6
-
3
/
4
6
FIGURE 6 - UNIT DIMENSIONS - FRONT & BOTTOM  
1
4
-
1
/
2
S
A
I
I
D
R
E
S
U
P
P
L
Y
O
P
E
N
I
N
G
2
8
-
3
/
8
C
O
N
D
E
N
S
E
R
C
O
I
L
1
4
-
1
/
2
B
A
C
K
B
O
T
T
O
M
S
U
P
P
L
Y
A
I
R
O
P
E
N
I
N
G
3
-
3
/
8
S
I
D
E
R
E
T
U
R
N
A
I
R
O
P
E
N
I
N
G
1
4
-
1
/
2
3
-
1
/
2
4
1
-
3
/
4
1
5
1
5
1
-
3
/
4
1
5
B
O
T
T
O
M
R
E
T
U
R
N
A
I
R
O
P
E
N
I
N
G
3
-
1
/
2
2
9
-
9
/
1
6
1
-
3
/
4
FIGURE 7 - UNIT DIMENSIONS - BACK & BOTTOM  
Johnson Controls Unitary Products  
17  
   
292443-XTG-D-0508  
C
O
N
T
O
R
O
N
L
W
I
R
I
N
G
T
O
P
O
W
E
R
S
U
P
P
Y
T
H
I
D
O
O
R
F
I
E
L
D
S
U
P
P
L
I
E
D
T
E
R
M
O
S
T
A
T
D
I
S
C
O
N
N
E
C
T
S
W
I
T
C
H
L
O
C
A
T
E
D
T
O
R
E
A
R
O
F
U
N
I
T
R
E
T
U
R
N
A
I
R
D
U
C
T
S
U
P
P
L
Y
A
I
R
D
U
C
T
T
O
G
A
S
U
P
P
L
Y
L
I
N
E
M
A
N
U
A
L
G
A
S
S
H
U
T
-
O
F
F
V
A
L
V
E
FIGURE 8 - TYPICAL SLAB ON GROUND INSTALLATION  
M
A
N
U
A
L
G
A
S
S
H
U
T
-
O
F
F
V
A
L
V
E
F
I
E
L
D
S
U
P
P
L
I
E
D
D
I
S
C
O
U
N
N
E
C
T
S
W
I
T
C
H
M
O
N
T
E
D
O
N
U
N
I
T
T
O
P
O
W
E
R
S
U
P
P
L
Y
T
O
G
A
S
S
U
P
P
L
Y
L
I
N
E
C
O
N
T
R
O
L
W
I
R
I
N
G
T
O
I
N
D
O
O
R
T
H
E
R
M
O
S
T
A
T
R
E
T
U
R
N
A
I
R
D
U
C
T
S
U
P
P
L
Y
A
I
R
FIGURE 9 - TYPICAL ROOF CURB INSTALLATION  
18  
Johnson Controls Unitary Products  
   
292443-XTG-D-0508  
R
O
O
F
C
U
R
B
I
R
N
S
T
A
L
L
A
T
I
O
N
E
A
R
D
U
C
T
R
I
B
O
O
F
C
U
R
B
N
S
T
A
L
L
A
T
I
O
N
O
T
T
O
M
D
U
C
T
S
I
L
A
B
O
N
G
R
O
U
N
D
N
S
T
A
L
L
A
T
I
O
N
FIGURE 10 - TYPICAL DUCT APPLICATIONS  
TABLE 15: UNIT WEIGHTS AND CENTER OF GRAVITY  
CORNER WEIGHTS  
(location, lbs.)  
SHIPPING  
WEIGHT  
(lbs.)  
395  
OPERATING  
WEIGHT  
(lbs.)  
390  
ROOF  
CURB  
(lbs.)  
UNIT  
SIZE  
ECONOMIZER  
(lbs.)  
“A”  
98  
“B”  
95  
“C”  
96  
“D”  
99  
030  
036  
042  
048  
060  
400  
395  
100  
104  
119  
120  
96  
98  
101  
105  
120  
122  
8” - 70  
14” - 75  
415  
410  
100  
115  
116  
101  
116  
117  
40  
475  
470  
480  
475  
FIGURE 11 - UNIT CENTER OF GRAVITY  
Johnson Controls Unitary Products  
19  
     
292443-XTG-D-0508  
R
E
C
D
O
U
M
M
E
N
D
E
D
C
T
S
I
Z
E
1
7
-
1
/
2
"
X
1
6
-
3
/
4
"
4
2
-
2
/
3
4
5
-
1
/
8
4
0
-
3
/
4
1
7
-
5
/
8
1
7
-
1
/
4
4
3
-
1
/
4
3
-
1
/
2
O
P
E
N
I
N
G
F
O
R
2
2
R
E
T
U
R
N
A
I
R
D
U
C
T
O
P
E
N
I
N
G
F
O
R
1
S
U
P
P
L
Y
A
I
R
D
U
C
T
R
E
C
D
O
U
M
M
E
N
D
E
D
C
T
S
I
Z
E
1
7
-
1
/
8
"
X
2
1
-
1
/
2
"
1
4
1
FIGURE 12 - ROOF CURB DIMENSIONS  
1. 8” Roof curb also available  
1
"
3
/
4
"
X
1
"
W
I
D
E
G
A
S
K
E
T
I
N
G
F
O
R
C
U
R
B
F
R
A
M
E
A
N
D
A
L
L
D
U
C
T
S
U
P
P
O
R
T
S
U
R
F
A
C
E
S
U
N
I
T
B
A
S
E
U
N
I
T
B
A
S
E
R
A
I
L
W
O
O
D
N
A
I
L
E
R
C
O
U
N
T
E
R
F
L
A
S
H
I
N
G
8
"
M
I
N
.
A
B
O
V
E
F
I
N
I
S
H
E
D
R
O
O
F
1
4
"
C
A
N
T
S
T
R
I
P
C
U
R
B
F
R
A
M
E
I
N
S
U
L
A
T
I
O
N
A
N
D
R
O
O
F
I
N
G
M
A
T
E
R
I
A
L
I
N
S
U
L
A
T
I
O
N
R
O
O
F
D
E
C
T
A
N
D
R
O
O
F
I
N
G
M
A
T
E
R
I
A
L
FIGURE 13 - ROOF CURB CROSS SECTION  
20  
Johnson Controls Unitary Products  
   
292443-XTG-D-0508  
FIGURE 14 - TYPICAL WIRING DIAGRAM DNA 030 THRU 060 (208/230-1-60 POWER SUPPLY)  
Johnson Controls Unitary Products  
21  
 
292443-XTG-D-0508  
FIGURE 15 - TYPICAL WIRING DIAGRAM DNA 036, 042, 048, 060 (208/230-3-60 POWER SUPPLY)  
22  
Johnson Controls Unitary Products  
 
292443-XTG-D-0508  
FIGURE 16 - TYPICAL WIRING DIAGRAM DNA 036, 042, 048, 060 (460-3-60 POWER SUPPLY)  
Johnson Controls Unitary Products  
23  
 
292443-XTG-D-0508  
6. If both LR and ASCT are present, wire 801/BL and 805/  
BL are connected to ASCT-3. If only LR is present wire  
801/BL and 805/BL are connected to M1 coil. If only  
ASCT is present wire 202/Y is connected to ASCT-3. If  
neither LR or ASCT are present, wire 202/Y is connected  
to M1 coil as shown.  
TYPICAL WIRING DIAGRAM NOTES  
1. All field wiring to be accomplished following city, local  
and/or national codes in effect at time of installation of  
this unit.  
7. Shunt contact also used with crankcase heater.  
(optional)  
2. Caution: Label all wires prior to disconnection when ser-  
vicing controls. Wiring errors can cause improper and  
dangerous operation. If any of the wire as supplied with  
this unit must be removed it must be replaced with type  
105°C, 600V wire or equivalent clearly renumbered for  
identification. Verify proper operation after servicing.  
8. Select indoor blower speed to remain within the temper-  
ature rise range on the nameplate in heating.  
3. Motors inherently protected.  
4. Factory wired for 230V. For 208V operation, move wire  
107/PR to 208V. Tap on transformer T1.  
Open all disconnects before servicing this unit.  
5. See unit nameplate for maximum fuse size and/or circuit  
breaker size and minimum circuit ampacity.  
LEGEND  
ALS  
ASCT  
BR  
AUXILARY LIMIT SWITCH  
ANTI-SHORT CYCLE TIMER (OPTIONAL)  
BLOWER RELAY  
CB  
CIRCUIT BREAKER  
CCH  
COMPR  
DM  
CRANK CASE HEATER (OPTIONAL)  
COMPRESSOR  
DRAFT MOTOR  
FCB  
GND  
FS  
FAN CONTROL BOARD  
GROUND  
FREEZE STAT SWITCH (OPTIONAL)  
HIGH PRESSURE SWITCH OPENS @ 380 PSIG  
INDOOR FAN MOTOR  
HP  
IDFAN  
LP  
LOW PRESSURE SWITCH OPENS @ 7 PSIG  
LIMIT SWITCH  
LS  
LR  
LOCK OUT RELAY (OPTIONAL)  
CONTACTOR, COMPR. AND OD FAN  
OUTDOOR FAN MOTOR  
M1  
ODFAN  
PS  
PRESSURE SWITCH  
RC1 / RC2  
RS  
COMPRESSOR START & OUTDOOR FAN RUN CAPACITOR  
ROLLOUT SWITCH  
TB4  
T1  
TERMINAL BLOCK  
TRANSFORMER, 24V, 230V  
FIGURE 17 - TYPICAL WIRING DIAGRAM LEGEND  
nized steel tubular heat exchangers and spark to pilot igni-  
tion. They are available in natural gas with field conversion to  
propane.  
MECHANICAL SPECIFICATIONS  
GENERAL  
DESCRIPTION  
Units shall be manufactured by York International Unitary  
Products Group in an ISO 9001 certified facility. YORK’s  
Affinity™ package units are designed to handle applications  
ranging from residential to light commercial and any in  
between. The Affinity™ is a unit that gives you the flexibility  
and choices you need in today’s market. These packaged  
cooling/heating air conditioners are designed for outdoor  
installation. Only utility and duct connections are required at  
the point of installation. The gas fired heaters have alumi-  
Units shall be factory-assembled, single packaged, Electric  
Cooling/Gas Heating units, designed for outdoor mounted  
installation. For EER ratings, refer to technical literature.  
They shall have built in, equal size, field convertible duct  
connections for down discharge supply/return or horizontal  
discharge supply/return. The units shall be factory wired,  
piped, charged with R-22 refrigerant and factory tested prior  
24  
Johnson Controls Unitary Products  
     
292443-XTG-D-0508  
to shipment. All unit wiring shall be both numbered and  
color coded. All units shall be manufactured in a facility cer-  
tified to ISO 9001 standards, and the cooling performance  
shall be rated in accordance with DOE and ARI test proce-  
dures. The heating performance shall be rated to DOE and  
GAMA test procedures. Units shall be CSA listed and classi-  
fied to ANSI Z21.47/CAN/CSA 2.3 standards and UL 1995/  
CAN/CSA No. 236-M90 conditions.  
rosion resistant steel spider bracket and shall be statically  
balanced for smooth operation. The outdoor fan motor shall  
be totally enclosed with permanently lubricated bearings and  
internally protected against overload conditions.  
REFRIGERANT COMPONENTS  
Compressors:  
a. Shall be fully hermetic type, direct drive, internally  
protected with internal high-pressure relief and over  
temperature protection. The hermetic motor shall be  
suction gas cooled and have a voltage range of + or  
- 10% of the unit nameplate voltage.  
UNIT CABINET  
Unit cabinet shall be constructed of galvanized steel, with  
exterior surfaces coated with a non-chalking, powdered paint  
finish, certified at 1000 hours salt spray test per ASTMB117  
standards. The unit top shall be a single piece “Water Shed”  
design, with drip edges and no-seam corners to provide opti-  
mum water integrity. Unit shall have a rigidly mounted con-  
denser coil guard to provide protection from objects and  
personnel after installation. Indoor blower section shall be  
insulated with up to 3/4” thick, aluminum, foil faced insulation,  
fastened to prevent insulation from entering the air stream.  
Cabinet panels shall be “large” size, easily removable for ser-  
vicing and maintenance, with built-in lift handles. Unit shall be  
built on a formed, “Super-Structure” design base pan, with  
embossments at critical points to add strength, rigidity and  
aid in minimizing sound. Full perimeter base rails shall be  
provided to assure reliable transit of equipment, overhead rig-  
ging, for truck access and proper sealing on roof curb appli-  
cations. Base rails shall be removable, when required, to  
lower unit height. Filters shall be furnished and be accessible  
through a removable access door, sealed airtight. Units verti-  
cal discharge and return duct configuration shall be designed  
to fit between standard 24” O.C. beams without modification  
to building structure, duct work and base unit. Condensate  
pan shall be internally sloped and conform to ASHRAE 62-89  
self-draining standards, with 3/4” NPTI copper, ridged mount  
connection.  
b. Shall have internal isolation and sound muffling to  
minimize vibration and noise, and be externally iso-  
lated on a dedicated, independent mounting.  
Coils:  
a. Evaporator and condenser coils shall have alumi-  
num plate fins mechanically bonded to seamless  
internally enhanced copper tubes with all joints  
brazed.  
b. Evaporator coil shall be of the direct expansion,  
blow through design, while condenser coil shall be  
draw through design.  
Refrigerant Circuit and Refrigerant Safety Components:  
a. Shall include independent fixed-orifice expansion  
devices.  
b. Shall include filter/strainer to eliminate any foreign  
matter.  
UNIT OPERATING CHARACTERISTICS  
Unit shall be capable of starting and running at 125º F out-  
door temperature, exceeding maximum load criteria ARI  
Standard 210/240. The compressor, with standard controls,  
shall be capable of operation down to 45º F outdoor tempera-  
ture. Accessory low ambient kit shall be available for opera-  
tion to 0º F.  
INDOOR (EVAPORATOR) FAN ASSEMBLY  
Fan shall be direct drive, multi-speed design. Job site  
selected (BHP) brake horsepower shall not exceed the  
motors nameplate horsepower rating. Fan wheel shall be  
double-inlet type with forward-curved blades, dynamically  
balanced to operate smoothly throughout the entire range of  
operation. Airflow design shall be constant air volume. Bear-  
ings shall be sealed and permanently lubricated for longer life  
and no maintenance. Fan assembly shall be “Slip Track”  
(slide-out) design for easy removal and cleaning.  
ELECTRICAL REQUIREMENTS  
All unit power wiring shall enter unit cabinet at a single factory  
provided location and be capable of side or bottom entry, to  
minimize roof penetrations and avoid unit field modifications.  
Separate side and bottom openings shall be provided for the  
control wiring.  
OUTDOOR (CONDENSER) FAN ASSEMBLY  
The outdoor fan shall be of the direct-driven propeller type,  
discharge air vertically, have aluminum blades riveted to cor-  
Johnson Controls Unitary Products  
25  
292443-XTG-D-0508  
26  
Johnson Controls Unitary Products  
292443-XTG-D-0508  
Johnson Controls Unitary Products  
27  
Subject to change without notice. Printed in U.S.A.  
292443-XTG-D-0508  
Copyright © 2008 by Johnson Controls, Inc. All rights reserved.  
Supersedes: 292443-XTG-C-0108  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  

Oracle Audio Technologies Retail Data Warehouse 13 User Manual
Panasonic Cu E15dkr User Manual
Royal Sovereign Arp 904ec User Manual
Samsung Ast18s0ge User Manual
Samsung Clx 6260fw Laser Multifunction Printer Clx 6260fw User Manual 3
Sanyo Cl1872 User Manual
Soleus Air Ky 80 User Manual
Sterilite Corporation Baby Accessories S12q User Manual
Toshiba Air Conditioner Mmy Map1404ht8zg E User Manual
Traxxas Automobile Parts 5304 User Manual