Important Safety Instructions  
To reduce the risk of fire, electrical shock, or injury when using your appliance, follow  
these basic precautions:  
1. Place the appliance on hard and level surfaces where it can not be easily knocked  
down.  
2. Do not use if the power supply cord is damaged. If damaged, it must be replaced  
by a qualified electrician.  
3. This appliance is not intended for use by young children or physically-challenged  
persons without supervision/assistance. Young children must be supervised to  
ensure safety around this or any appliance.  
4. Always switch off and unplug the appliance when replacing filters, cleaning,  
moving or not in use.  
5. Keep the appliance away from any heat source, direct sunlight or area with  
excessive moisture such as bathroom and kitchen.  
6. This air purifier is an electrical appliance. To avoid injury from electrical shock do  
not operate the appliance with wet hands, while standing on a wet surface or while  
standing in water. Do not use outdoors or in wet conditions.  
7. Avoid placing any objects on top of the appliance.  
8. Never pull the cord to disconnect it from the power outlet. Grasp the plug and pull  
it from the outlet.  
9. Never lift or carry the appliance by the power cord.  
10. This appliance is designed for household, non-commercial use only. Any other use  
will void the warranty  
11. Do not try to disassemble, modify or repair the appliance by yourself.  
12. Do not use the appliance upside down or its side.  
13. Do not block the air intake and air outlet.  
14. When positioning the appliance, ensure that there is at least a 6” clearance  
around the appliance. This allows for adequate ventilation.  
15. If used with a humidifier, please keep this appliance away from the humidifier.  
16. Never use harsh detergents or solvents to clean the appliance.  
17. Do not operate the appliance without installing the filters.  
18. Do not wash and reuse the Whynter HEPA filter. HEPA filters should only be  
replaced, not cleaned.  
3
Technical Data  
Product size  
Input voltage  
Airflow  
11”L x 11”D x 2.6”H  
AC 100-240V / DC12V  
High: 45m3/h / 26.5cfm Low: 25m3/h / 15cfm  
Pre-filter  
Activated carbon filter  
HEPA filter  
Air Purification System  
Photocatalyst filter  
UV Lamp  
Weight  
2.5 lbs  
<45db  
8W  
Noise  
Power  
Coverage Area  
150 Sq. Ft.  
PARTS OVERVIEW  
Main Unit  
4
5
ONE TOUCH OPERATION  
ON/OFF: Turns the air purifier on and off. When the air purifier is on, the green light  
comes on. When the air purifier is off, no light comes on.  
SPEED: The default fan speed is Low (green light). Press the SPEED button to  
change to High fan speed (red light). Press the SPEED button again to change the fan  
speed to LOW (green light).  
FILTER & SCENT MAINTENANCE  
Lift up the three hinges at the back of the air input cover and pull it backward to  
remove the cover.  
Pre-filter: Remove the washable pre-filter. Rinse the pre-filter in warm water. Do not  
wash it in a washing machine or dish washer. Do not use water hotter than 100F  
degree. When the pre-filter is completely dry, place it back to the air purifier.  
Activated Carbon Filter & HEPA Filter: Remove the Activated carbon filter and the  
HEPA filter and replace with new ones. The Activated carbon filter and HEPA filter  
needs to be replaced every 2,000 working hours. The higher level of pollutants, the  
6
shorter the lifespan of the filter. Dispose of the old HEPA and carbon filters and do not  
reuse. Please contact Whynter’s service department at [email protected] to  
order replacement filters.  
Photo catalyst filter: The Photo catalyst filter needs to be replaced after 6 months of  
working hours. Please contact Whynter’s service department at  
[email protected] to order replacement filters.  
Scent replenishment: Remove the scent sponge, drop one to two drops of your  
favorite scented oil to the sponge and put it back into the unit.  
7
CLEANING & MAINTENANCE  
The surface of the air purifier should be cleaned at least once a month or more often  
depending on the air quality.  
Use a clean, dry cloth to wipe the external surfaces.  
Use a damp cloth to remove stubborn stains and dirt build up.  
Clean the air inlets and outlet with a dry cloth or a vacuum cleaner.  
When dismounting or mounting the front cover, please be careful not to break the hinge.  
Service time of each filters are as follows:  
Pre-filter: 1500 hours  
Activated carbon filter: 2000 hours  
HEPA filter: 2000 hours  
Photo catalyst filter: 4500 hours  
UV lamp: The average service life of UV lamp is 3-5 years. Do not replace the UV lamp on  
your own, it should only be changed by a qualified technician.  
Scent freshener: Add scent as desired.  
TROUBLESHOOTING  
Trouble  
Check list  
Solution  
Unit does not start  
There is a power supply failure  
Ensure the air purifier’s power  
supply is securely in the unit and the  
power outlet has power  
The air input cover is installed  
properly  
Install the cover properly  
The air purifier is noisy and  
vibrates  
The unit is not level  
Ensure the unit sits on a hard and  
level surface. Do not place the unit  
on carpets.  
Odor and smoke are not  
removed  
Filters are dirty  
Clean or replace filters  
The unit is unable to circulate air Install unit in a place where air is  
able to circulate  
Air does not flow from the  
unit  
Air inlets maybe obstructed  
Ensure the air inlets are not  
obstructed  
8
ONE YEAR LIMITED WARRANTY  
This WHYNTER air purifier is warranted, to the original owner within the 48  
continental states, for one year from the date of purchase against defects in material  
and workmanship under normal use and service. Should your WHYNTER air purifier  
prove defective within one year from the date of purchase, return the defective part or  
unit, freight prepaid (within two months of purchase; after two months to one year,  
customer will be responsible for freight cost to Whynter’s service department), along  
with an explanation of the claim to Whynter LLC. Please package the air purifier  
carefully in its original packaging material to avoid damage in transit. Please retain the  
original box and packaging material. Under this warranty, Whynter will repair or  
replace any parts found defective. This warranty is not transferable. After the  
expiration of the warranty, the cost of labor and parts will be the responsibility of the  
original owner of the unit.  
THIS WARRANTY DOES NOT COVER:  
Filters  
Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.  
Damage, accidental or other wise, to the air purifier while in the possession of  
a consumer not caused by a defect in material or workmanship;  
Damage caused by consumer misuse, tampering, or failure to follow the care  
and special handling provisions in the instructions.  
Damage to the finish of the case, or other appearance parts caused by wear.  
Damage caused by repairs or alterations to the air purifier by anyone other  
than authorized by the manufacturer.  
Freight and Insurance cost for the warranty service.  
To obtain service or information, contact  
Whynter LLC via Email at [email protected] or  
call 866-WHYNTER.  
9

Metrologic Instruments Quantume Is3480 User Manual
Mitsubishi Electronics Msz Fa35va User Manual
Mtd Automobile Parts 277cc User Manual
Panasonic Kx Mb2060 User Manual
Panasonic Kxp 8410s User Manual
Sharp Mfp Series User Manual
Sony Vgpbpsc27 User Manual
Trane Air Cleaner Cah Svx01a En User Manual
York Predatortm Magnum Dj 150 User Manual
York Sunline Magnum Dy 060 User Manual