VEC022APC
Jump-Start System
260 PSI AIR COMPRESSOR • 12 VOLT DC POWER SUPPLY
OWNER’S MANUAL
& WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION,
MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USING, READ AND UNDERSTAND
ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S
BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN INJURY AND/
OR PROPERTY DAMAGE.
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312
TEL: 954-584-4446 • TOLL FREE: 866-584-5504 • FAX: 954-584-5556
Manual 022APC
1
12/20/02, 8:40 PM
SAFETY INFORMATION
WARNING:
(Warning statements identify conditions or practices that may result in personal
injury or loss of life)
1) When working with lead acid batteries, always make sure immediate assistance
is available in case of accident or emergency.
2) Always use protective eyewear when using this product: contact with battery acid
may cause blindness and/or severe burns, be aware of first aid procedures in
case of accidental contact with battery acid.
3) There is a risk of explosive gases being released when lead acid batteries are
being charged or discharged. Failure to follow instructions may cause property
damage, explosive hazard, and/or personal injury.
4) When connecting the battery clamps to a discharged battery, and an alarm sounds
- the polarity is reversed.
5) When charging unit from a 110/120 Volt AC electrical outlet in any wet or damp
area, make sure that the outlet used is protected by a ground fault interrupt (GFI)
Switch.
6) When charging the unit near water, do not allow the electrical cords and outlets
to get wet or come near water–electrical shock could result.
7) Jump-start procedures should only be performed in a safe, dry, well-ventilated
area.
8) When using this unit in proximity to the vehicle’s battery and engine, stand the
unit on a flat, stable surface, and be sure to keep all clamps, cords, clothing and
body parts away from moving vehicle components.
9) Do not wear vinyl clothing when jump-starting a vehicle, friction can cause
dangerous static-electricity sparks. Remove all jewelry or metal objects that could
cause short circuits or react with battery acid.
10) Always disconnect the negative (Black) jumper cable first: followed by the
positive (Red) jumper cable, except for positive ground systems.
11) Never allow red and black clamps to touch each other or another common metal
conductor–this could cause damage to the unit and/or create sparking/
explosion hazard. Always store battery clamps in built-in holsters when not in use.
12) Do not expose battery to fire or intense heat as it may explode. Before disposing
of the battery, protect exposed terminals with heavy-duty electrical tape to
prevent shorting (shorting can result in injury or fire).
13) Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while
working on a vehicle’s battery system.
14) Keep unit out of reach of children (whether stored, or in use)!
FIRST AID:
SKIN: If battery acid comes in contact with skin, rinse immediately with water, then
wash thoroughly with soap and water. If redness, pain, or irritation occurs, seek
immediate medical attention.
EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a
minimumof 15 minutes and seek immediate medical attention.
CAUTION:
(Caution statements advise against certain conditions and practices that may result
in damage to vehicles, appliances and/or The Jump-Starter)
3
Manual 022APC
3
12/20/02, 8:40 PM
IMPORTANT:
Although this unit is delivered in a partially charged state, you must fully charge it
with the supplied 110/120 Volt AC charger for a full 24 hours before using it for
the first time. You cannot overcharge the unit using the AC charger method.
1) Use only the supplied cords/adapters for recharging this unit. Do not recharge
for more than 3-4 hours maximum using 12 Volt DC method. Recharge unit after
each use.
2) All On/Off switches should be in the OFF position when the unit is charging or
not in use. Make sure all switches are in the OFF position before connection to a
power source or load.
3) Never insert anything other than the supplied power/recharging cords or
recommended appliance power/recharging cords into the 12 Volt DC charging/
power socket on this unit. Do not use any accessory that is not recommended or
provided by the manufacturer.
4) Do not use this unit to operate appliances that draw more than 20 amps.
5) This system is designed to be used only on vehicles with 12 Volt DC battery
systems. Do not connect to a 6 Volt or 24 Volt battery system.
6) This system is not designed to be used as a replacement for a vehicular battery.
Do not attempt to operate a vehicle that does not have a battery installed.
7) Vehicles that have on-board computerized systems may be damaged if vehicle
battery is jump-started. Before jump-starting, read the vehicle’s owners manual
to confirm that external-starting assistance is advised.
8) Excessive engine cranking can damage a vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedures and look for other problems that may need to be corrected.
9) Although this unit contains a non-spillable battery, it is recommended that unit be
kept upright during storage, use and recharging. To avoid possible damage that
may shorten the unit’s working life, protect it from direct sunlight, direct heat
and/or moisture.
10) Check unit periodically for wear and tear. Replace worn or defective parts
immediately. Contact Vector Customer Service department toll-free 866-584-5504.
11) Do not attempt to jump-start a frozen battery.
12) Never submerge this unit in water.
13) DO NOT over-inflate tires.
4
Manual 022APC
4
12/20/02, 8:40 PM
1.
INTRODUCTION
Congratulations on selecting the VECTOR® JUMP-STARTER, AIR COMPRESSOR and
12 VOLT DC POWER SUPPLY. This compact jump-starter is unique in the amount of
energy it can supply for its size. The internal battery is a high density sealed,
lead-acid battery that stores and delivers energy comparable to full sized ordinary
jump-starters. Please read this guide carefully before use to ensure optimum
performance and avoid damage to the unit or items that you are using it with.
A standard feature of this model is a high pressure, self-contained tire compressor
with lighted gauge. This compressor allows quick inflation of vehicle tires to 260 PSI
and with supplied adapter nozzles, inflates beach balls, rafts and virtually any low-
pressure inflatables. Three different sized nozzles allow for easy connection to all
popular inflatables.
The VECTOR® JUMP-STARTER & 12 VOLT DC POWER SUPPLY is a compact, durable
and portable jump-start system for vehicles and boats that have a standard 12 Volt
battery system. This self-contained, rechargeable system will start most vehicles and
boats without the need for a host vehicle or 110/120 Volt AC power supply. It can
also be used as a safe, portable source of 12 Volt DC electric power in remote loca-
tions and/or emergency situations. It is ideal for use with Vector 12 Volt DC cordless,
portable, rechargeable products and MAXXSST DC/AC Power Inverters.
Use the VECTOR JUMP-START SYSTEM to:
• Jump-start any engine system with a standard 12 Volt DC battery: boat; truck; car;
airplane; RV; personal watercraft; snowmobile; garden tractor; gasoline engine
generator, etc.
• Operate: 12 Volt DC fans, inflators, fluorescent worklights, cellular phones (can
quick-charge a cellular phone by using the phone’s 12 Volt DC adapter cord),
spotlights, TVs, portable radios, cassette or CD players, and more.
Operate: Certain 110/120 Volt AC Accessories (requires a Vector 12 volt power
inverter, sold separately).
The JUMP-START SYSTEM has an easy-to-read series of LED (Light Emitting Diode)
charge indicators that show when the unit is fully charged, or the level of charge in the
battery. Charge level can be viewed when the charge status push button is pressed. A
12 Volt DC accessory socket is provided for use with appliances that can operate from
a vehicle 12VDC accessory outlet. This allows maximum portability and utility when
the Jump-Start Sytem is used in remote locations.
The Jump-Start System can be recharged from any standard 110/120 Volt AC power
source using the supplied AC Recharge Adapter. The adapter barrel connector
attaches to the Recharge Port on the top panel of the jump-starter. A built-in 12 Volt
appliance socket and the appropriate DC/DC charging/adapter cord is used to
recharge the battery from another 12 volt DC source. When pressed, the CHARGE
STATUS button will show the battery power level status (from Low to Full). The green
LED full indicator illuminates when the unit is fully recharged and charging can be
discontinued. An ON/OFF switch operates the built-in work/emergency light.
5
Manual 022APC
5
12/20/02, 8:40 PM
1
9
3
2
3
12
13
10
5
6
7
4
8
15
11
16
14
FIGURE 1A (FRONT VIEW)
FIGURE 1B (REAR VIEW)
1. Reverse connection indicator
2. Good connection indicator
3. 12 Volt DC Accessory Socket with 20 amp overload protection
4. Battery Level Push Button
5. LED Charging/Battery Level Indicators
6. Heavy-Duty Welding Quality Jumper Cables
7. Heavy-Duty Copper Clamps
8. Exclusive Quick-Release Clamp Holsters
9. 110/120 Volt UL approved AC/DC Charging Adapter
10. 12 Volt DC/DC Charging Adapter
11. Built-in CCFL Emergency/Worklight
12. Light ON/OFF Switch
13. AC Recharge Adapter barrel connector receptacle
14. 260 PSI compressor air hose and tire chuck
15. Analog pressure gauge
16. Compressor Power Switch
17. Inflation Adapters included (not shown)
ADDITIONAL FEATURES:
• Includes non-spillable, maintenance-free, heavy-duty, new high energy density
19 Amp hour, sealed battery
• Sturdy and unique compact design provides up to 35 hours of completely portable
12 Volt DC power
• Safe to use, transport, and store. Includes an audible polarity alarm
• Requires no maintenance (other than recharging) for optimum operation
• Automatic taper charge for AC recharge
• Audible alarm for reverse polarity
• Molded high-impact case is tough and durable
• Built-in emergency/worklight with krypton bulb for roadside repairs and use in
remote locations without utility power
CAUTION:
Use only adapters supplied with this unit. Never insert any other adapters into the
charging or power receptacles on this unit.
6
Manual 022APC
6
12/20/02, 8:40 PM
2.
USE AS A JUMP-START SYSTEM
WARNING:
1. Before using this system to jump-start any vehicle or boat, read and understand
all instructions, safety tips, warnings, cautions and first aid information
provided in this manual and on the product labeling. Additional important
information may also be provided by the vehicle’s battery system manufacturer.
2. Be aware of first aid procedures before attempting jump-start procedure.
3. Always wear protective eyewear when working with a lead acid-type battery.
4. Do not smoke or use inflammable items (matches, cigarette lighters, etc.) while
working on a vehicle’s battery system.
5. When using this jump-starter in proximity to the vehicle’s battery and engine,
stand the unit on a flat, stable surface, and be sure to keep all cords and cables
away from any moving parts.
6. Check unit periodically for wear and tear. Replace worn or defective parts
immediately; contact Vector Customer Service Department toll-free:
7. Do not attempt to jump-start a frozen battery.
8. NEVER submerge this unit in water.
9. Do not wear vinyl clothing when jump-starting a vehicle, friction can cause
dangerous static electricity sparks. Remove all jewelry or metal objects-they can
cause short circuits or react with battery acid to cause severe burns. Remove or
secure any loose clothing, and restrain long hair, before attempting jump-start
procedure.
10. Lead-acid batteries generate hydrogen gas during normal operation. More gas is
generated when the battery is charging. Hydrogen gas is explosive, poisonous
to breathe and highly flammable.
Recommendations for optimum performance of the VECTOR® Jump-starter:
CAUTION:
1. To avoid possible damage that may shorten the unit’s working life, protect this
unit from direct sunlight, direct heat and moisture.
2. This system is to be used ONLY on vehicles, boats, garden tractors and gasoline
powered generators with 12 Volt DC battery systems.
3. This system is NOT designed to be installed as a replacement for a vehicle battery.
4. Vehicles that have on-board computerized systems may be damaged if vehicle
battery is jump-started. Before jump-starting this type of vehicle, read the vehicle
owner’s manual to confirm that external-starting assistance is advised.
5. Excessive engine cranking can damage the vehicle’s starter motor. If the engine
fails to start after the recommended number of attempts, discontinue jump-start
procedure and look for other problems that may need to be corrected.
6. This VECTOR® jump-starter is equipped with an internal, automatic
safety switch. This switch only activates when connections to the battery are
correctly made positive (+) to positive (+) and negative (-) to negative (-). An
incorrect connection will sound an audible alarm indicating an incorrect
connection. Should this alarm sound, remove the clamps and reconnect ensuring
proper polarity. Once the connections are properly made, the internal switch
turns on and you are ready to jump-start the vehicle. This automatic internal
safety switch is fully automatic and requires no action by the user.
7
Manual 022APC
7
12/20/02, 8:40 PM
2.1
EASY, STEP-BY-STEP JUMP-STARTING INSTRUCTIONS
This jump-starter is equipped with an automatic safety switch that only allows
jump-start energy to flow when proper connections are made to battery and
frame. The automatic switch works in conjunction with an audible reverse
polarity alarm and a large red LED. If inadvertent reverse polarity occurs, the
alarm will sound and the red LED will light. Disconnect the black clamp (negative
clamp) first, then the red clamp. Reconnect properly and a green LED will light.
Wait one minute and then turn the key. To recap:
Connect – Red clamp first, then black clamp.
Disconnect – Black clamp first, then red clamp.
Note: The automatic safety switch and polarity alarms require the vehicle
battery to have at least 2 volts when the clamps are connected
1. Turn OFF vehicle ignition and all accessories (radio, A/C,
lights, cell phone, etc.). Place vehicle in park and set the
emergency brake.
2. Remove booster clamps from protective holster (Figure 1):
simply squeeze the handles and pull up on the clamp.
3. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (NEGATIVE
BATTERY TERMINAL IS CONNECTED TO CHASSIS).
3a. Connect positive (+) red clamp to vehicle battery’s positive terminal.
3b. Connect negative (-) black clamp to chassis or a solid, non-moving, metal
vehicle component or body part. Never clamp directly to negative battery
terminal or moving part. If the audible alarm sounds, the polarity is not correct.
Reverse the connections.
4. Procedure for jump-starting POSITIVE GROUND SYSTEMS
(NOTE: In the rare event that the vehicle to be started has a Positive Grounded
System (positive battery terminal is connected to chassis) replace steps
3a and 3b above with steps 4a and 4b, then proceed to steps 5 through
7 below.
4a.Connect negative (-) black clamp to vehicle battery’s negative
terminal
4b. Connect positive (+) red clamp to vehicle chassis or a solid, non-mov
ing, metal vehicle component or body part. DO NOT CLAMP DIRECTLY
TO POSITIVE BATTERY TERMINAL OR MOVING PART
5. A five (5) second delay is built into this jump-starter unit after the clamp
connections are made. This delay is designed to reduce the possibility of sparking
upon connection. We recommend waiting one (1) minute after making the clamp
connections prior to attempting to start vehicle.
6. Start vehicle (do not turn key for longer than 3-5 seconds).
7. After vehicle starts, remove clamps (disconnect the frame or engine clamp first,
followed by the battery cable) and replace them in the built-in storage holsters.
Squeeze the handles and slide the clamp into position and release your grip.
CAUTION:
1. If engine fails to start, leave ignition key turned off and disconnect the negative
(-) clamp first, then the positive (+) clamp. Try again later – the engine may be flooded.
2. Recharge jump-start system after each use.
WARNING:
•
Always disconnect the engine or frame jumper clamp first; followed by the
battery jumper clamp
•
There is a risk of explosive gases being released when batteries are charged or
discharged, failure to follow instructions may cause property damage, explosive
hazard, and/or personal injury
8
Manual 022APC
8
12/20/02, 8:40 PM
•
Always use protective eyewear when using this product: contact with battery acid
may cause blindness and/or severe burns
•
•
Keep out of children’s reach
ALWAYS store battery clamps in built-in holsters when not in use and never touch
battery clamps together, this can cause dangerous sparks, power arcing and/or
explosion
FIRST AID:
• SKIN: If battery acid comes in contact with skin, rinse immediately with water, then
wash thoroughly with soap and water. If redness, pain, or irritation occurs, seek
immediate medical attention
• EYES: If battery acid comes in contact with eyes, flush eyes immediately for
a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION
3.
CHARGING/RECHARGING
For maximum battery life, we recommend the VECTOR® system be kept fully charged
at all times. If the battery is allowed to remain in a discharged state, battery life will be
shortened.
NOTE: Recharging battery after each use will prolong battery life; frequent discharges
between recharges will reduce battery life
IMPORTANT:
• MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING
• Charge unit for full 24 hours using AC method, prior to first use
• Recharge unit fully after each use
• Recharge unit every two months, when it has not been used
3.1
110/120 VOLT AC CHARGING
1. Simply plug the AC plug of the AC/DC adapter/charger into any standard 110/
120 volt AC wall outlet.
2. Plug the barrel connector attached to the AC/DC adapter into the small barrel
receptacle on the jump-starter that is marked recharge port.
3. After initial 24 hour charge, charge this device for at least 14-16 hours or until the
green FULL indicator lights. Charge at least once a month when not in use.
4. When charging is completed and the FULL light lights, remove the AC/DC charger
plug and store in a safe place.
NOTE:
The unit cannot be overcharged using the AC method. The VECTOR® system also
comes with a DC/DC charging adapter for recharging the unit from a 12 volt DC
accessory socket in a vehicle or boat .
This recharging method will NOT recharge the unit as effectively as recharging from a
110/120 volt AC outlet. The 12 Volt DC recharging procedure is recommended only
when it is necessary, as continued use of the 12 Volt DC recharging procedure may
shorten the battery system’s life .
If unit is fully discharged, it is recommended that the vehicle being used for recharging
be left running while the unit is being charged via the 12 Volt DC method.
WARNING:
Do not recharge for more than 3-4 hours maximum using 12 Volt DC method.
9
Manual 022APC
9
12/20/02, 8:40 PM
3.2
12 VOLT DC CHARGING
1. Insert one end of the DC/DC charging adapter into a 12 Volt DC accessory
receptacle on the vehicle or boat.
2. Insert the plug at the other end of this charging adapter into the 12 Volt DC
accessory socket receptacle on the front of the unit.
3. Charge the unit until the green FULL indicator lights when Charge Switch
Indicator Button is pressed. DO NOT EXCEED 3-4 HOURS MAXIMUM.
4. When charging is completed, remove the power cord and store in a safe place.
3.3
ESTIMATED BATTERY LIFE
Table I shows the relationship of the frequency of use between recharging and the
expected number of discharge/recharge cycles.
Table I - Estimated Battery Life between recharges (lifetime of unit’s battery)
USE
1
RECHARGES
1000+
700+
5
10
500+
4.
OPERATION AS A 12 VOLT PORTABLE POWER SUPPLY
1. Lift up the cover of the unit’s 12 Volt DC accessory receptacle (See Figure 1).
2. Insert the 12 volt DC plug from the appliance into the receptacle on the unit.
3. Switch on the appliance, and operate as usual.
CAUTION:
DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW
MORE THAN 20 AMPS DC
Table II shows the estimated 12 volt DC operation time when using a fully
charged system.
Table II - VECTOR® as a 12 Volt DC Power Supply
Appliance
Estimated Power Usage Operating Time
(Watts)
(hours)
Cell phone
1
120 (talk time)
Fluorescent light
4
40
24
14
10
2
Radio, fan, depth finder
Camcorder, VCR, spotlight
Power tools, bilge pump
Car vacuum
9
15
24
80
NOTE: ALL TIMES ARE APPROXIMATE AND BASED UPON A FULLY CHARGED UNIT.
10
Manual 022APC
10
12/20/02, 8:40 PM
5.
6.
EMERGENCY WORKLIGHT
The Worklight is controlled by an On/Off switch. Make sure the lamp is turned OFF
when the unit is being recharged or stored. The lamp is efficient and will operate up to
114 hours on a full charge. The CCFL lamp’s operating life is 100,000 hours.
AIR COMPRESSOR/TIRE INFLATOR
IMPORTANT:
Read Instructions Carefully To Avoid Possible Injury Or Property Damage.
The built-in 12 Volt DC air compressor is the ultimate compressor for all vehicles,
trailer tires and recreational inflatables. Three different sized nozzles are supplied.
Each nozzle will clip on the end of the standard tire valve connector located at the free
end of the compressor hose. The compressor nozzles are stored inside the hose hatch.
The compressor hose with tire fitting is stored in a retaining channel between the
jumper cable channels on the rear of the unit. The ON/OFF Switch is located on the
side of the Main Unit near the AC Recharge Port. The compressor can operate long
enough to fill up to 3 average sized tires before the battery must be recharged.
The compressor may be used by removing the air hose from the storage hatch and if
required, fitting an appropriate nozzle to the air hose. An On/Off switch located on
the side of the unit controls the power to the compressor and the gauge light. Refer to
Figure 3 for locations of compressor hose, nozzle storage hatch and hose. Return
hose to the storage compartment after use.
STORAGE HATCH
FOR HOSE AND
ADAPTERS
INFLATION
COMPRESSOR
ADAPTERS
HOSE AND
(NOZZLES)
CHUCK
6.1
WARNINGS FOR COMPRESSOR USE
The compressor is capable of inflating up to 260 pounds per square inch (PSI)
pressure. To avoid over-inflation, carefully follow instructions on articles to be
inflated. Never exceed recommended pressures. Bursting articles can cause
serious injury. Always check pressure with the pressure gauge. Never leave
compressor unattended while in use. Allow unit to cool after 10 minutes of
continuous operation.
11
Manual 022APC
11
12/20/02, 8:40 PM
6.2
TIRE INFLATION OR PRODUCTS WITH A VALVE STEM
1. Place connector (chuck) on valve stem.
2. Push connector toward valve stem and close thumb latch.
3. Make sure connector is pushed onto valve stem as far as possible before
closing thumb latch.
4. Check pressure with the pressure gauge.
5. When desired pressure is reached, turn OFF Compressor Power Switch.
6. Open thumb latch and remove connector from valve stem.
7. Store compressor hose and tire fitting in storage compartment.
IMPORTANT:
Always leave the thumb latch in the open position when storing unit.
6.3
INFLATING OTHER ARTICLES (WITHOUT VALVE STEM)
Inflation of other items requires use of one of the adapters (nozzles).
1. Open the hatch and remove the nozzles noting their storage positions.
2. Insert appropriate adapter (e.g. needle) into connector (chuck) and close
thumb latch.
3. Refer to Table III, Typical Inflation Times, for approximate filling pressure and
time. Small items such as volleyballs, footballs, etc. inflate very rapidly.
4. Insert adapter (e.g. needle) into item to inflate to appropriate pressure.
5. Turn ON compressor switch - inflate to desired pressure or fullness (refer to
paragraph 6.4).
6. Turn off compressor switch.
7. Remove adapter from item.
6.4
TYPICAL INFLATION TIMES
The following are approximate pressure and inflation times for various items.
WARNING:
Always follow tire manufacturers recommendations for pressure on item to
be inflated.
Table III
INFLATION PRESSURE (PSI)
FILLING TIME
VEHICLE AND TRAILER TIRES
155/80R 13”
26
30
30
50
2.5 min
4.5 min
6.5 min
16 min
185/70R 14”
235/75R 15”
235/85R 16”
BICYCLE TIRES
27” X 1” (racing)
Football
10
13
9
40 sec.
24 sec.
20 sec.
6 sec
Basketball
Volleyball
5
12
Manual 022APC
12
12/20/02, 8:40 PM
7.
REPLACEMENT PARTS
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector Customer Service:
(954) 584-4446 or toll-free (866) 584-5504.
7.1
7.2
CCFL
CCFL lamp is designed for 100,000 hours of operation.
It is not user replaceable.
BATTERY REPLACEMENT
It is recommended that the unit be returned to Vector Customer Service
for battery replacement: Contact (954) 584-4446 or toll-free
(866) 584-5504.
WARNING:
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical
tape to prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode
7.3
BATTERY DISPOSAL:
This unit contains a maintenance-free, non-spillable, sealed lead-acid
battery. This battery is fully recyclable and should be accepted at any
location that accepts common automotive starter batteries. Examples of
places that accept these batteries are: County or municipal recycling
drop-off centers, scrap metal dealers and retailers who sell automotive
replacement lead acid starter batteries. For more information on
recycling this battery, call toll-free (877) 288-7722.
8.
SPECIFICATIONS
Model ................................................................................. VEC022APC
Boost Ampere..................................... 450 Instantaneous Cranking Amps
Peak Ampere ....................................................................... 1200 Amps
Continuous Cranking .............................................................. 250 Amps
Battery Type ....................... Sealed, high energy density, AGM, lead-acid,
.............. rechargeable, maintenance-free, 12 volt DC, 19 Amp-hour
Area Light ................................... Cold Cathode Fluorescent Lamp (CCFL)
Booster Cables ......................................... Heavy duty welding cable with
................................................................. 450 Amp copper clamps
Accessory Socket..................................... Self-Resetting Breaker 20 Amps
Air Compressor .......................................................................... 260 PSI
DC Charging Adapter ............................................................12 Volt DC
AC Charging Adapter ......110/120 Volt AC (700mA, 12 Volt DC Output)
Reverse Polarity Detection .................................................... 2 Volts (min)
HEIGHT ................................................................... 11.75 in. (29.8 cm)
DEPTH ............................................................................8.25 in (21 cm)
WIDTH ................................................................... 11.625 in (29.5 cm)
WEIGHT .....................................................................19.1 lb. (8.66 Kg)
13
Manual 022APC
13
12/20/02, 8:40 PM
TWO YEAR LIMITED WARRANTY PROGRAM
This limited warranty program is the only one that applies to this product, and it sets forth all the
responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other warranty,
other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free of
defects in materials and workmanship for two years from the date of purchase without additional
charge. The warranty does not extend to subsequent purchasers or users. Vector Manufacturing, Ltd.
will not be responsible for any amount of damage in excess of the retail purchase price of the product
under any circumstances. Incidental and consequential damages are specifically excluded from cov-
erage under this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or
damage to units from misuse or incorrect installation. Misuse includes wiring or connecting to im-
proper polarity power sources.
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned postage
prepaid to Vector Manufacturing. Any defective product, other than accessories, that is returned to
Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge. If such
a product is returned more than 30 days but less than two years from the purchase date, Vector
Manufacturing will repair the unit or, at its option, replace it free of charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector Manufacturing’s
option. A unit may be replaced with a new or reconditioned unit of the same or comparable design.
The repaired or replaced unit will then be warranted under the terms of the remainder of the warranty
period. The customer is responsible for the shipping charges on all returned items after 30 days.
During the warranty period, Vector Manufacturing, Ltd. will be responsible for the return shipping
charges.
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting
from normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to
usage or exposure to sunlight), accidents, damage during shipping to our service facility, alterations,
unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care and mainte-
nance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department at
(954) 584-4446 or toll free at 866-584-5504 for general repair information and charges if
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations
on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential
damages, so the exclusions or limitations stated herein may not apply. This warranty gives the pur-
chaser specific legal rights; other rights, which vary from state to state, may apply.
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Vector Manufacturing
Technical Support by telephone, fax or mail. We suggest that you keep the original packaging in case
you need to ship the unit. When returning a product, include your name, address, phone number,
dated sales receipt (or copy) and a description of the reason for return and product serial number.
After repairing or replacing the unit, we will make every effort to return it to you within four weeks.
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Vector
Manufacturing. Enter “VEC022APC” as Model and Jump-starter/compressor/12VDC power supply
as “Product Type”. All Vector Manufacturing, Ltd. products must be registered within (10) days of
purchase to activate this warranty. Mail the completed registration form, along with a copy of the
original sales receipt to:
ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.
4140 SW 28th Way, Ft. Lauderdale, FL 33312
PH: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556.
WARRANTY MUST BE PURCHASED WITHIN 10 DAYS OF PRODUCT PURCHASE DATE.
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.
14
Manual 022APC
14
12/20/02, 8:40 PM
15
Manual 022APC
15
12/20/02, 8:40 PM
© 2002 VECTOR MANUFACTURING, Ltd.
FT. LAUDERDALE, FL 33312 MADE IN CHINA
112202
Manual 022APC
16
12/20/02, 8:40 PM
|