Ultraviolet Devices Hygeaire Air Disinfection User Manual

375 Marcus Boulevard Hauppauge, NY 11788 USA  
631.273.0500 Fax: 631.273.0771  
Extensive Product Information Available at:  
ultraviolet.com  
Document No. 98-1137A1 • Revised September 2007 • ©2003-2007 Atlantic Ultraviolet Corporation  
SAFETY WARNINGS  
All personnel should be alerted to the potential hazards indicated by the product safety labeling on this fixture.  
The following conventions are used to indicate and classify precautions in this manual and on product safety  
labeling. Failure to observe precautions could result in injury to people or damage to property.  
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all  
safety messages that follow this symbol to avoid possible injury or death.  
!
Danger indicates an IMMINENTLY hazardous situation, which, if not avoided, WILL result in  
death or serious injury.  
Warning indicates a POTENTIALLY hazardous situation, which, if not avoided, COULD  
result in death or serious injury.  
Caution indicates a POTENTIALLY hazardous situation, which, if not avoided, MAY result in  
minor or moderate injury.  
Caution used without the safety alert symbol indicates a potentially hazardous situation, which,  
if not avoided, may result in property damage.  
This symbol/pictorial is used to identify an ELECTRICAL SHOCK or ELECTROCUTION  
hazard.  
This symbol/pictorial is used to identify an ULTRAVIOLET LIGHT hazard.  
This symbol/pictorial is used to identify the need to wear approved ultraviolet resistant eyewear.  
This symbol/pictorial is used to identify the need to wear protective gloves.  
Product safety labels should be periodically inspected and cleaned, as necessary, to maintain good legibility.  
Always replace illegible safety labels. Contact factory to obtain replacement safety labels.  
3
SAFETY INSTRUCTIONS  
!
WARNING: To guard against injury, basic safety precautions should be observed, including the following:  
1. Read and follow ALL safety instructions.  
2.  
!
WARNING: Avoid exposure to direct or strongly reflected germicidal ultraviolet rays.  
Germicidal ultraviolet rays are harmful to the eyes and skin.  
3. Intended for indoor use only.  
4. Do not alter the construction or design.  
5. Do not override safety interlock.  
6. Do not remove safety labels or devices.  
7.  
!
CAUTION: Do not operate without proper electrical ground.  
8. Do not operate without louver panel secured.  
9. Use personal protection equipment, such as gloves, long sleeves with no gaps between cuffs and gloves, and  
an ultraviolet resistant face shield, when entering the irradiated space above 6 ½ feet.  
10. Utility power supplied, to the fixture, MUST match power requirements listed on the System label.  
11. Always disconnect power, from the fixture, before performing any maintenance.  
12. Read and follow all notices and warnings on the fixture.  
13. SAVE THESE INSTRUCTIONS.  
PRODUCT APPLICATION  
CONSTRUCTION  
The Hygeaire® brand fixtures are categorized as indirect type germicidal fixtures, which utilize germicidal lamp(s)  
with a series of louvers to direct ultraviolet rays to the upper areas of a room, thereby destroying bacteria and viruses  
that are carried into the ultraviolet field by convection currents or air circulation.  
The Hygeaire® consists of; a Louver Panel, Parabolic Reflectors with specular aluminum inserts, Electronic Variable  
Output Ballast, Germicidal Lamp, and Stainless Steel Housing.  
LIMITATIONS  
Hygeaire® requires knowledgeable planning for; location, installation, and continued supervision to prevent exceed-  
ing the ultraviolet radiant exposure incident Threshold Limit Value (TLV) set by the American Conference of  
Governmental Industrial Hygienists. Currently the ultraviolet radiant exposure incident for unprotected skin or eyes  
should not exceed 0.2 microwatts per square centimeter (µW/cm2) at 254 nanometers (nm) for an eight (8) hour period.  
Hygeaire® requires professional installation so all wiring complies with applicable local and national electrical codes.  
Installation is permanent, and relatively inflexible.  
Safety and maintenance procedures should be implemented to prevent accidental exposure of personnel, who might  
enter the irradiated space (Electricians and other trades people in particular). All work performed (painting, new ceil-  
ings, equipment or fixture installation, etc.) in the irradiated space must be monitored to insure that they do not  
adversely impact the safety or effectiveness of the installation.  
4
IINSPECTION  
Remove the Hygeaire® fixture from its shipping carton. Inspect the fixture, and wire leads for damage. Do not oper-  
ate if there is any damage to the fixture, and/or wire leads. Lamp(s) are packed separately, to ensure maximum protec-  
tion to the lamp(s). Keep the lamp(s) aside until ready for installation. When installing lamp(s) into the fixture, exercise  
care not to touch the lamp's glass. Oils deposited, from fingers, on the glass could effect ultraviolet transmission.  
The Hygeaire® Model LIND 24-EVO fixture includes:  
1 - Model LIND 24-EVO single lamp fixture with 6 inch lead wires  
1 - Germicidal Ultraviolet Lamp  
1 - Operating Instructions  
The Hygeaire® Model LIND 24-EVO-2PM fixture includes:  
1 - Model LIND 24-EVO-2PM dual lamp fixture with 4 ½ foot lead wires  
1 - Pendant Mounting Kit, consisting of:  
1 - #19 Crossbar  
1 - #11 Canopy  
2 - 3/8" IP Stems 18 inches long  
2 - #14 3/8" IP Slip Rings  
6 - #22 3/8" IP Locknuts  
2 - Germicidal Ultraviolet Lamps  
1 - Operating Instructions  
INSTALLATION  
LOCATION  
The Hygeaire® fixture is recommended for use in rooms with good ventilation, with a ceiling height of 9 feet or  
more and where occupants remain for prolonged periods.  
Access to the room does not need to be controlled while the fixture is operating.  
The louver panels of the Hygeaire® fixtures protect room occupants from ultraviolet exposure, by directing  
ultraviolet radiation into the upper areas of the room.  
Any plans for the installation of the Hygeaire® fixtures, should take into account the reflectance of the ceiling.  
Some finishes may have reflectances that are objectionably high, making exposure of more than a few hours  
unsafe. If any help is needed in determining the reflectance of a surface, please contact the Factory.  
Ultraviolet energy, produced by the germicidal lamp(s), can fade some colors and/or alter the surface of some  
materials especially those directly irradiated by the lamp(s). If any help is needed in determining the ultraviolet  
resistance of any material, please contact the Factory.  
The Hygeaire® LIND 24-EVO fixture is designed to mount horizontally on a vertical surface, or wall,  
approximately 6 ½ to 7 feet above the floor.  
The Hygeaire® LIND 24-EVO-2PM fixture includes pendant hardware to suspend fixture from the ceiling.  
Standard stem pipe length is 18 inches. Other lengths are available, contact the Factory with requirements.  
5
INSTALLATION  
INSTALLATION OF LIND 24-EVO  
Figure 1 - LIND 24-EVO Installation  
1. The fixture is to be mounted on a plumb, vertical surface, at a minimum height of 6 ½ to 7 feet from the floor.  
Installation must be able to support approximately 16 pounds.  
2. Remove thumbscrews and open fixture to expose interior lamp holders and reflectors.  
3. Remove one mounting screw from each end of the reflector so that the reflector will be able to pivot toward the  
lamp holder.  
4. Pivot reflectors, on remaining screws, to expose the rear mounting holes and 7/8-inch wire access hole.  
5. All wiring should confirm to state and local electrical codes as well as the current National Electrical Code (NEC).  
6. After mounting and wiring, pivot reflectors back into place and replace mounting screws. Install lamp (packed  
separately), close fixture and replace thumbscrews.  
6
INSTALLATION OF LIND 24-EVO-2PM  
Figure 2 - LIND 24-EVO-2PM Installation  
1. Installation and all wiring should confirm to state and local electrical codes as well as the current National  
Electrical Code (NEC). Installation must be able to support approximately 32 pounds.  
2. After fixture is mounted and wired, open louver panels by removing thumbscrews. Install lamps (packed  
separately), close panels and replace thumbscrews.  
RECOMMENDED OPTIONS  
1. ZenithTM Ultraviolet Meter: Provides accurate Easy-To-Read Levels of Intensity that may be interpreted by  
anyone, not just engineers. Zenith’sTM design makes it insensitive to ambient lighting within the area being surveyed.  
PRECAUTIONS  
Immediately following initial installation of the Hygeaire® fixture, the occupied area, of the room, should be surveyed  
with the ZenithTM Ultraviolet Meter, to insure that the ultraviolet radiant exposure of personnel is within acceptable  
limits. Thereafter this procedure should be repeated whenever any maintenance is performed, including lamp changes  
or whenever maintenance or repairs are performed in the vicinity of the fixture. In addition, procedures should be  
adopted to insure that the fixture is switched off whenever personnel are working above the 6-foot level. Personnel who  
work in and around the treated area should be briefed on the benefits and the precautions to be observed.  
If there are any doubts or questions about the safety or the effectiveness of the installation, or if a sensitive ultraviolet  
meter is required, please contact the Factory.  
7
MAINTENANCE  
The Hygeaire® is designed to operate with a minimal amount of maintenance. Besides occasional ultraviolet measure-  
ments to insure that ultraviolet intensities in the treated areas remain within the allowable exposure limits and above  
minimum levels, a regular cycle of cleaning, the germicidal lamp and interior reflectors, should be established based on  
visual inspection and experience. The frequency of cleaning will vary with the conditions surrounding each installation.  
It is recommend that the germicidal lamp(s) and interior reflectors be cleaned at least every three (3) months.  
The germicidal lamp used in the Hygeaire® fixture is a high output instant start lamp with a rated average effective  
life of 10,000 hours. For maximum efficiency, lamp replacement is recommended every 10,000 hours of operation.  
Personal protection equipment is required only when entering the irradiated space, above 6 ½ feet from the floor, or  
when opening the louver panel, with the germicidal lamp operating. Personal protection equipment would include skin  
and eye protection such as gloves, long sleeves with no gaps between cuff and gloves, and an ultraviolet resistant face  
shield.  
The Hygeaire® is equipped with a safety interlock switch that will shut down the germicidal lamp when the louver  
panel is opened.  
!
CAUTION: Do not override safety interlock switch. Operation of the fixture with the override of the inter-  
lock switch and louver panel open will expose personnel to direct or strongly reflected germicidal ultraviolet  
rays. Germicidal ultraviolet rays are harmful to the eyes and skin.  
ULTRAVIOLET OUTPUT ADJUSTMENT  
If after a survey of the occupied area of the room shows the ultraviolet radiant exposure of personnel is not within  
acceptable limits, the output of the Hygeaire® fixture must be adjusted. The electronic variable output ballast controls  
germicidal ultraviolet lamp output. The remote potentiometer, used for output adjustment, is recessed in the base of the  
fixture. Access, to the potentiometer, is limited by a ½" ID plug which must be removed before any adjustments can be made.  
1. Locate and remove protective plug.  
2. Carefully insert a small flat bladed screwdriver, through the clearance hole in the fixture, into the slotted shaft of  
the potentiometer. Slowly turn the shaft until desired output is reached. Turning shaft clockwise increases output,  
while turning the shaft counterclockwise decreases output.  
3. Replace protective plug.  
CLEANING GERMICIDAL LAMPS  
!
CAUTION: Germicidal lamps are easily damaged. Exercise care when removing or replacing lamps.  
1. Shut down power to the fixture, and disconnect fixture from utility power source, if possible.  
2. Open the louver panel, by removing the two (2) thumbscrews.  
3. Carefully remove the germicidal lamp(s), from the telescoping lamp holders. Wipe down the lamp using a clean,  
soft rag and denatured alcohol. After cleaning, re-install lamp(s) into the fixture, exercise care not to touch the  
lamp's glass with your fingers.  
4. Finally remove any visible dust from the interior of the fixture with a clean, soft rag or vacuum cleaner.  
5. Close the louver panel and re-install thumbscrews.  
6. Reconnect fixture to utility power, and restart fixture.  
DISPOSAL OF MERCURY ADDED LAMPS  
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added  
lamps should not be placed in the trash. Dispose of properly.  
For further information regarding the disposal and recycling of lamps containing mercury, along with Federal and State  
“PDF Library for Ster-L-RayTM Germicidal Ultraviolet Lamps” section of http://www.ultraviolet.com.  
8
TROUBLESHOOTING  
!
CAUTION: Always disconnect power to the fixture, before performing any service.  
Use personal protection equipment, such as gloves; long sleeves with no gaps between cuffs  
and gloves, and ultraviolet resistant face shield, if troubleshooting Hygeaire®.  
IMPORTANT: This fixture is to be serviced ONLY by qualified, and appropriately licensed, personnel.  
Table 1 - Troubleshooting  
Problem  
Possible Cause  
Corrective Action  
No electrical power…  
Verify that the purifier is connected to a live power source.  
Fixture not operating.  
Power connections, to fixture, Verify power connections to fixture are fully engaged.  
loose or disconnected…  
Lamp(s) not installed…  
Install lamp(s).  
Germicidal lamp not  
properly seated…  
Confirm connection of lamp and lamp holder, make sure  
connection is tight and lamp holder is making full contact  
with lamp.  
Germicidal lamp faulty…  
Swap suspect lamp, with lamp known to be good. If  
suspect lamp does not operate, replace lamp.  
Germicidal lamp  
not operating.  
Ballast not functioning…  
Interlock Switch open…  
Interlock Switch faulty…  
Locate ballast and replace.  
Confirm louver panel is closed and secured.  
Replace Interlock Switch.  
TECHNICAL SPECIFICATIONS  
Table 2 Technical Specifications  
MODEL  
LIND 24-EVO  
LIND 24-EVO-2PM  
Length:  
Width:  
Height:  
24"  
24"  
1
2
Dimensions:  
4 / "  
9"  
7
7
8
8
7- / "  
7- / "  
c
Volts:  
120v  
.42A  
220-240v  
.23A  
120v  
.83A  
220-240v  
.45A  
Electrical:  
Amps (Max):  
Frequency:  
50/60Hz 50/60Hz  
8.5 Watts  
50/60Hz 50/60Hz  
17 Watts  
Total Ultraviolet Output:c  
c Ultraviolet output at 254 nm at 100 hours and 80° F (approximate).  
d 120v 50/60Hz and 220-240v 50/60Hz units are standard - specify when ordering. Consult factory  
with other specific power requirements.  
9
REPLACEMENT PARTS  
LIND 24-EVO  
Figure 3 - Replacement parts Model LIND 24-EVO  
Item No.:  
Description:  
Germicidal Ultraviolet Lamp, G24T6L  
Quantity:  
Part No.  
05-1348  
1
1
Electronic Variable Output Ballast, 120v 50/60Hz  
Electronic Variable Output Ballast, 220-240v 50/60Hz  
Lamp Holder Set  
10-0056B  
10-0055B  
05-1320A  
35-0008A  
50-0080  
2
1
3
4
5
6
1
1
2
1
Safety Interlock Switch  
Thumbscrew, 8-32 x 3/8" Lg  
Plug, ½" ID  
00-0027  
Other replacement parts are available. Consult the Factory for specific requirements.  
10  
REPLACEMENT PARTS  
LIND 24-EVO-2PM  
Figure 4 - Replacement parts Model LIND 24-EVO-2PM  
Item No.:  
Description:  
Quantity:  
Part No.  
05-1348  
1
Germicidal Ultraviolet Lamp, G24T6L  
Electronic Variable Output Ballast, 120v 50/60Hz  
Electronic Variable Output Ballast, 220-240v 50/60Hz  
Lamp Holder Set  
2
10-0056B  
10-0055B  
05-1320A  
35-0008A  
50-0080  
2
2
3
4
5
6
7
8
2
2
4
2
1
2
Safety Interlock Switch  
Thumbscrew, 8-32 x 3/8" Lg  
Plug, ½" ID  
00-0027  
Hanger, Canopy Set  
40-0127  
Hanger, Stem, 3/8" IP x 18" Lg  
40-0129A18  
Other replacement parts are available. Consult the Factory for specific requirements.  
11  
USER ASSISTANCE  
Atlantic Ultraviolet Corporation  
375 Marcus Boulevard  
Hauppauge, New York, 11788  
Atlantic Ultraviolet Corporation  
makes every effort to ensure that  
the Hygeaire® Ultraviolet Air  
Disinfection Fixtures are products  
of superior quality and workman-  
ship. This manual describes the  
installation, operation and mainte-  
Please read and become familiar  
with the contents of this manual  
before installing or using this fix-  
ture. If after reading the manual  
you still have questions, or con-  
cerns, regarding the installation or  
use of this fixture, contact our  
Tel: 631.273.0500  
Fax: 631.273.0771  
nance of the Hygeaire® Ultraviolet offices, weekdays between 8:30 am  
Air Disinfection Fixtures. and 5:00 pm Eastern time, at:  
Please fill out and return the Owner Registration card immediately. If the card is missing from this manual,  
please contact any of our application specialists to obtain one.  
Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage.  
Carefully inspect and report all damage. Do not install damaged equipment. Follow all instructions on any labels  
or tags. Carefully inspect all packing materials before discarding to prevent the loss of accessories, mounting  
hardware, spare parts or instructions.  
For your convenience, record the following information below. The model and serial number can be found on  
a label located on the Hygeaire® Ultraviolet Air Disinfection Fixtures. Keep this manual, along with proof of  
purchase, handy when contacting our offices.  
Purchased From:  
Model:  
Date:  
Serial No.:  
WARRANTY  
We warrant that this product will be free from defects in material and workmanship for a period of one year  
from the date of shipment thereof or the product’s total rated life, whichever first occurs. Within the warranty  
period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and  
which are determined by us to be defective. This warranty will not apply to any product, which has been sub-  
jected to misuse, negligence, or accident; or misapplied; or modified; or repaired by unauthorized persons; or  
improperly installed.  
The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing of  
claims, including claims of breach of warranty, within thirty (30) days after the Buyer discovers or should have  
discovered the facts upon which the claim is based. Failure of the Buyer to give written notice of a claim within  
the time period shall be deemed to be a waiver of such claim.  
The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties,  
expressed or implied, including warranties of merchantability and fitness for a particular purpose, whether or not  
purposes or specifications are described herein. We further disclaim any responsibility whatsoever to the cus-  
tomer, or to any person, for injury to person, damage to, or loss of property or value caused by any product  
which has been subjected to misuse, negligence, accident; or modified or repaired by unauthorized persons; or  
improperly installed.  
Under no circumstances shall the Company be liable for any incidental, consequential or special damages,  
losses or expenses arising from the contract for this product, or in connection with the use of, or inability to use,  
our product for any purpose whatsoever.  
PATENT NOTICE  
No attempt has been made to determine the patent status of applications illustrated or described in this publi-  
cation. Inclusion in this publication of any design or method of use, which may be patented, is not to be con-  
strued as promoting or sanctioning unauthorized use.  
12  

Mitsubishi Electronics Split Type Heat Pump Air Conditioners Pmfy P06nbmu E1 User Manual
Panasonic Cu A18ctp5 User Manual
Radio Shack 43 3808 User Manual
Samsung As12hpan User Manual
Samsung Avmkc032ca0 User Manual
Schumacher Nin 812a User Manual
Schumacher Sc 6500a User Manual
Soleus Air Sg Pac 10e5 User Manual
Vector Vec012apc User Manual
Xantrex Technology Tc10tb User Manual