ELECTRICAL REQUIREMENTS  
The electrical ratings for your air conditioner are listed on the model and serial  
number label located on the front left side of the unit (when facing the front).  
Specific electrical requirements are listed in the chart below. Follow the  
requirements below for the type of plug on the power supply cord.  
Power Supply Cord  
Electrical Shock Hazard  
Plug into a grounded 3 prong outlet.  
Do not remove the ground prong.  
Do not use an adapter  
NEMA 6-20P  
Do not use an extension cord.  
Failure to follow these instructions can result in death,  
fire, or electrical shock  
Recommended Ground Method  
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power  
supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong  
outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus-  
tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.  
Copies of the standards listed may be obtained from:  
It is the customer’s responsibility:  
National Fire Protection Association  
To contact a qualified electrician  
One Batterymarch Park  
Quincy, Massachusetts 02269  
To assure that the electrical installation is adequate  
and in conformance with the National Electrical Code,  
ANSI/NFPA 70 - latest edition, and all local codes and  
ordinances.  
LCDI Power Cord and Plug - NEMA 6-20P  
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as  
required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination  
on the load side and a LCDI attachment plug on the line side.  
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current  
leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-  
energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or  
combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if  
exposed. The cord shield must not be connected to ground or to any exposed metal.  
The test and reset buttons on the LCDI Plug are used to check if  
the plug is functioning properly. To test the plug:  
1. Plug power cord into a wall outlet, the power light will turn  
on.  
2. Press the TEST Button, the circuit should trip and cut all  
power to the air conditioner. The power light will turn off.  
3. Press the RESET button for use. The power light will turn  
back on.  
If a test is performed and the indicator light remains ON prior to  
pressing RESET, current leakage has been detected. Do not  
use the air conditioner or attempt to reset the LCDI Plug. Con-  
tact Customer Service for troubleshooting recommendations.  
3
IMPORTANT SAFETY INSTRUCTIONS  
Read all instructions before using this air conditioner  
FOR YOUR SAFETY  
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read  
product labels for flammability and other warnings.  
ACCIDENT PREVENTION  
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions,  
including the following:  
ꢀꢁ Be sure the electrical service is adequate for the model you have chosen. This information can be found on the se-  
rial number plate located on the side of the cabinet or behind the grille.  
ꢀꢁ If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass prior to in-  
stallation. If the windows is a triple-track type with a screen panel included, remove the screen completely before  
installation.  
ꢀꢁ Be sure the air conditioner has been securely and correctly installed according to the installation instructions pro-  
vided with this manual. Save this manual and the installation instructions for future use when removing and reinstall-  
ing the unit.  
ꢀꢁ When handling the air conditioner, be careful to avoid cuts form sharp metal fins on the front and rear coils.  
4
SPECIFICATIONS  
ꢀꢁ Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.  
ꢀꢁ Power consumption is measured when the fan runs at the highest speed setting.  
ꢀꢁ These specifications are for reference only. For actual data, please refer to the rating label on the unit.  
Model  
SG-TTW-10HC  
1/230-208/60  
60  
10,000/9,700  
10,600/8,600  
1,060/1,030  
3,450/2,800  
4.8/5.1  
SG-TTW-12HC  
1/230-208/60  
91.6  
12,000/11,700  
10,600/8,600  
1,280/1,240  
3,450/2,800  
6.0/6.5  
SG-TTW-14HC  
1/230-208/60  
100.8  
14,000/13,600  
10,600/8,600  
1,650/1,600  
3,450/2,800  
7.0/7.5  
Power Supply (Ph/V/Hz)  
Dehumidifier Capacity (Pints/Day)  
Rated Cooling Capacity (BTU/Hr)  
Rated Heating Capacity (BTU/Hr)  
Cooling Power Input (Watts)  
Heating Power Input (Watts)  
Rated Current Cooling (Amperage)  
Rated Current Heating (Amperage)  
EER (Cooling)  
15/13.6  
15.0/13.6  
9.4  
15/13.6  
9.4  
8.5  
Noise Level Indoor/Outdoor [dB(A)]  
Air Flow (CFM)  
59/70  
290  
59/70  
300  
61/70  
320  
Product Dimensions WxHxD (Inches)  
Product Weight (LBS)  
24 x 14.5 x 20.625 24 x 14.5 x 20.625 24 x 14.5 x 20.625  
79.4  
81.6  
84  
Refrigerant  
R-410A  
R-410A  
R-410A  
NORMAL OPERATING SOUNDS  
5
OPERATING YOUR AIR CONDITIONER  
Before you start using your air conditioner, please familiarize yourself with the control panel and remote control the func-  
tions of each. This air conditioner can be controlled by the control panel (touch pad) or the included remote control.  
CONTROL PANEL (TOUCH PAD for cool only model)  
LOWERS  
TEMPERATURE  
OR TIME  
DISPLAYS  
TEMPERATURE/TIME  
RAISES  
TEMPERATURE  
OR TIME  
TURNS UNIT  
ON OR OFF  
SETS FAN SPEED  
SETS MODE  
SLEEP MODE  
TIMER  
CONTROL PANEL (TOUCH PAD for cool and heat model)  
LOWERS  
TEMPERATURE  
OR TIME  
DISPLAYS  
TEMPERATURE/TIME  
RAISES  
TEMPERATURE  
OR TIME  
TURNS UNIT  
ON OR OFF  
SETS FAN SPEED  
SETS MODE  
SLEEP MODE  
TIMER  
6
Air Conditioner Features(continued)  
Note: Be sure that there are no obstructions between receiver and remote controller;  
Don't drop or throw the remote control; Don't let any liquid in the remote control and  
put the remote control directly under the sunlight or any place where is very hot.  
Signal transmitter  
SLEEP  
SLEEP button  
Press this button, Sleep On and Sleep  
Off can be selected. After powered on,Sleep  
Off is defaulted. After the unit is turned  
off, the Sleep function is canceled. After  
Sleep function set up, the signal of Sleep  
Remote control  
will display. In this mode, the time of timer  
can be adjusted. Under Fan and Auto  
modes, this function is not available.  
FAN  
FAN button  
By pressing this key, you may select AUTO,  
FAN 1, FAN 2, FAN 3 or FAN 4, and may  
also cycle between them. FAN 4 only in  
cool, save and heat mode. After being  
energized, AUTO is defaulted.  
ON/OFF  
ON/OFF button  
Press this button, the unit will be turned on,  
press it once more, the unit will be turned  
off. When turning on or turning off the unit,  
the Timer, Sleep function will be canceled,  
but the presetting time is still remained.  
Fan 1  
Fan 3  
Fan 2  
Fan 4  
MODE  
MODE button  
Press this button, Auto, Cool,Save(Energy  
Saver), Fan,Heat mode can be selected  
circularly. Auto mode is default while  
power on. Under Auto mode,the temperature  
will not be displayed; Under Heat mode,  
SWING  
SWING button  
Press this key to activate or deactivate  
the swing.  
oF);Under other  
the initial value is 28  
(82  
o
modes,  
the initial value is 2577 F) .  
(
AUTO  
SAVE  
COOL  
HEAT  
FAN  
AUTO  
COOL  
SAVE  
FAN  
HEAT  
(Only for cooling and heating unit.)  
7
Air Conditioner Features(continued)  
Notice: This is a general use remote controller, it could be used for the air conditioners  
with multifunction; For some function, which the model dosen't have, if press the  
corresponding button on the remote controller that the unit will keep the original  
running status.  
TIMER  
TIMER button  
By pressing this key under switch-off state,  
you may set the time for auto switch-on. The  
range of setting is 0.5 ~ 24 hours. The  
characters "T-ON" and "H" will flash for 5  
seconds. Within 5 seconds,you may make  
one press of this key to complete the setting  
and send the message.If the setting is valid,  
the set time will be displayed for 2 seconds  
before display of the temperature message.  
During flash, you may press "+" key to  
increase the value and press "-" key to decrease  
the value. The time will increase or decrease  
by 0.5 hours with each press of this key.  
If pressing "+" or "-" key continuously, the  
time value will change rapidly. The remote  
Remote control  
controller can increase the set time by 0.5  
hours every 0.25 seconds. After being  
energized, the fault is no timer setting, and  
+
there is no display of "T-ON" or "H". Press  
ON/OFF key to switch on the unit and cancel  
the auto switch-on.When the temperature  
+ button  
For presetting temperature increasing.  
Press this button,can set up the temperature,  
when unit is on . Continuously press and  
hold this button for more than 2 seconds,  
the corresponding contents will be  
display becomes constant, you may press  
this key again to display the remaining set  
time. The time value, "T-On" and "H" will  
display constantly for 2 seconds. After 2  
seconds,the preset temperature will be  
displayed. Within these 2 seconds, you may  
changed rapidly, until unpress the button  
o
then send the information, C(o F) is disp-  
laying all along. In Auto mode, the temp-  
erature can not be set up, but operate this  
button can send the signal. Centigrade  
setting range :16-30; Fahrenheit scale  
setting range 61-86.  
press this key again to cancel the auto  
switch-on and send the message.  
By pressing this key under switch-on state,  
you may set the time for auto switch-off.  
The method of setting as the same as for  
auto switch-on.  
-
- button  
Presetting temperature can be decreased.  
Press this button, the temperature can be  
set up, continuously press this button  
and hold for two seconds, the relative  
contents can quickly change, until unhold  
this button and send the order that the  
(oF) signal will be displayed all the time.  
The temperature adjustment is unav-  
ailable under the Auto mode, but the order  
can be sent by if pressing this button.  
8
Air Conditioner Features(continued)  
Guide for operation- General operation  
1. After powered on, press ON/OFF button, the unit will start to run.(Note: When  
it is powered off, the guide louver of main unit will close automatically.)  
2. Press MODE button, select desired running mode, or press COOL or HEAT  
mode to enter into the corresponding operation directly.  
3. Pressing + or - button, to set the desired temperature. (It is unnecessary  
to set the temp. at AUTO mode.)  
4. Pressing FAN button, set fan speed, can select AUTO, FAN 1, FAN 2,  
FAN 3 or FAN 4.  
5. Pressing SWING button, to select the swing.  
Guide for operation- Optional operation  
1. Press SLEEP button, to set sleep.  
2. Press TIMER button, can set the scheduled timer on or timer off.  
Introduction for special function  
About AUTO RUN  
When AUTO RUN mode is selected, the setting temperature will not be displayed on the  
LCD, the unit will be in accordance with the room temp. automatically to select the  
suitable running method and to make ambient comfortable.  
About LOCK  
Under switch-on or switch-off state, you may hold "+" and "-" key simultaneously to lock and  
unlock the keypad. When locked, the display will show the LOCK icon, in which case the  
lock icon will flash three times upon operation of any key. After the keypad is unlocked, the  
lock icon on the display will be hidden. After being energized, the default is unlock.  
About switch between Fahrenheit and Centigrade  
Under switch-off state, you may hold "-" and "MODE" keys simultaneously to switch between  
and.  
Changing batteries and notices  
Slightly to press the place  
to take out the back cover of wireless  
1.  
remote control.(As shown in figure)  
2.  
3.  
Take out the old batteries. (As show in figure)  
Insert two new AAA1.5V dry batteries, and pay attention to the polarity.  
(As show in figure)  
4.  
Attach the back cover of wireless remote control. (As show in figure)  
NOTE:  
When changing the batteries, do not use the old or different batteries,  
otherwise, it can cause the malfunction of the wireless remote control.  
If the wireless remote control will not be used for a long time, please  
take them out, and don't let the leakage liquid damage the wireless  
remote control.  
The operation should be in its receiving range.  
It should be placed at where is 1m away from the TV set or stereo sound sets.  
If the wireless remote control can not operate normally, please take them out,  
after 30s later and reinsert, if they cannot normally run, please change them.  
9
Air Conditioner Features(continued)  
TO TURN UNIT ON:  
YOU WILL SEE:  
DO THIS:  
PRESS ON/OFF  
BUTTON  
TO CHANGE  
TEMPERATURE SETTING:  
YOU WILL SEE:  
DO THIS:  
PRESS TO RAISE  
PRESS TO LOWER  
Note: Tap or hold either up(^) or down(v) button until the desired temperature is seen on display. This temperature will be  
°
automatically maintained anywhere between 61F (16° C) and 86F (30 C) for both cooling and heating modes.  
If you want the display to read the actual room temperature, "Select the fan only mode" .  
YOU WILL SEE THE  
SPEED CHOSEN:  
TO CHANGE FAN SPEEDS:  
LIGHT ON  
DO THIS:  
PRESS FAN SPEED  
BUTTON  
SELECT SPEED  
YOU WILL SEE:  
LIGHT ON  
TO USE AUTO FAN FEATURE:  
DO THIS:  
PRESS FAN  
SPEED BUTTON  
SELECT  
AUTO FAN  
Note: The fan speed toautomatically set to the speed needed to provideoptimum comfort settings with the set temperature.  
If the room needs more cooling, the fan speed will automatically increase. If the room needs lesscooling, the fan speed  
will automatically decrease. Auto fan speed cannot be used when in the Fan Only mode.  
10  
Air Conditioner Features(continued)  
TO OPERATE ON FAN ONLY:  
YOU WILL SEE:  
LIGHT ON  
DO THIS:  
PRESS  
MODE BUTTON  
CHOOSE  
FAN ONLY  
Note: Use this function only when cooling is not desired, such as for room air  
circulation. You can choose any fan speed you prefer,EXCEPT AUTO FAN.  
During this function, the display will show the actual current temperature, not the set temperature as in the cooling mode.  
TO USE THE  
ENERGY SAVER FEATURE:  
LIGHT ON  
YOU WILL SEE:  
DO THIS:  
PRESS  
MODE BUTTON  
CHOOSE  
ENERGY SAVER  
Note: In this mode, the fan will continue to run for a short time after the compressor cycles off.  
TIMER-DELAY  
START/STOP FEATURE:  
YOU WILL SEE  
FIRST  
THE TIME CHOSEN:  
DO THIS:  
PRESS TIMER  
BUTTON  
THEN  
DO THIS:  
PRESS TEMP/TIMER  
BUTTON  
LIGHT ON  
Note 1: For Delay Stop, the unit must be in the ON position.  
Note 2: For Delay Start, the unit must be in the OFF position.  
To adjust timer setting, tap or hold the UP arrow (^) or DOWN arrow (v) to change the delay time by 0.5 hour increments up to 10 hours,  
then by 1 hour increments up to 24 hours. The control will count down the timer remaining until start (8, 7.5, 7, etc.). After  
set Timer,the unit will enter into Timer mode by 5 seconds, then Timer light on, Set light off. In Timer mode: Set temperature  
and fan speed keeps previously set temperature and fan speed; Temperature display set temperature, no display if power  
turn off; Press Timer once, LED display remaining time of set time, LED return to set temperature by 5 seconds;  
When in Fan Only mode, LED only display room temperature, do not display set temperature.Turning the unit "ON" or  
"OFF" at any timer will cancel the Delay Start/Stop function. The delay Start/Stop feature will work until the unit either starts  
or stops. Once this has happened then the above steps have to be repeated again.  
11  
Air Conditioner Features(continued)  
HEATING FEATURE (on some models):  
:
YOU WILL SEE  
DO THIS:  
PRESS  
MODE BUTTON  
SELECT HEAT  
Note: This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes. When in the “Heat” Mode, the  
fan will run continuously while heat is needed. The temperature will automatically be maintained anywhere between 61°F  
(16°C) and 86°F (30°C). When the room set temperature is satisfied, the fan will cycle off and on to circulate and sample  
the room air.  
:
YOU WILL SEE  
SLEEP FEATURE :  
DO THIS:  
PRESS  
MODE BUTTON  
SELECT SLEEP  
Note: Press this button, Sleep On and Sleep Off can be selected.After powered on,Sleep Off is defaulted. After the unit is  
turn off, the Sleep function is canceled. As the unit is in Cool or Energy Saver Modes, if Sleep Mode is set, SET TEMP. would  
increase 1in 1 hour and 2in 2 hours. As the unit is in Heat Mode, if Sleep Mode is set, SET TEMP. would decrease 1in  
hour and 2in 2 hours.Under Fan Only and Auto modes, this function is not available.  
:
TO TURN UNIT OFF  
YOU WILL SEE:  
DO THIS:  
PRESS  
ON/OFF BUTTOT  
4-Way Directional Louvers  
The 4-Way directional louvers allow you to direct the air up or  
down, left or right. Use the handle in the center of the louvers to  
change the air direction.  
12  
Cabinet Cleaning  
CARE AND CLEANING  
To clean the air conditioner cabinet:  
Clean your air conditioner to keep it looking new  
and to minimize dust build up.  
ꢀꢁ Unplug the air conditioner to prevent shock or  
a fire hazard. The cabinet and front panel of  
the air conditioner may be dusted with an oil-  
free cloth or washed with a cloth dampened in  
a solution of warm water and mild liquid soap.  
Rinse thoroughly with a damp cloth and wipe  
dry.  
Air Filter Cleaning  
The air filter should be checked at least once  
every month to see if it needs cleaning. Trapped  
particles and dust can build up in the filter and  
may decrease airflow as well as cause the  
cooling coils to accumulate frost. To clean the air  
filter:  
ꢀꢁ Never use harsh cleaners, wax or polish on  
the cabinet front.  
ꢀꢁ Be sure to wring excess water from the cloth  
before wiping around the controls. Excess  
water in or around the controls may cause  
damage to the air conditioner.  
1. Remove the filter by pulling down on the in-  
dents of the filter door on the front of the unit.  
(See FIG. 13)  
2. Wash the filter using liquid dish soap and  
warm water. Rinse the filter thoroughly. Gen-  
tly shake the filter to remove excess water.  
3. Let the filter dry completely before placing it  
Energy Saving Ideas  
into the air conditioner.  
ꢀꢁ Do not block the air flow inside with blinds,  
curtains or furniture; or outside with shrubs,  
enclosures, or other buildings.  
4. If you do not wish to wash the filter, you may  
vacuum the filter to remove the dust and  
other particles.  
ꢀꢁ The capacity of the room air conditioner must  
fit the room size for efficient and satisfactory  
operation.  
ꢀꢁ Install the room air conditioner on the shady  
side of your home. A window that faces North  
is best because it receives the least amount  
of sun exposure.  
ꢀꢁ Close the fireplace damper, floor and wall  
registers so cool air does not escape.  
ꢀꢁ Keep blinds and drapes closed for cooling  
and open for heating.  
FIG. 13  
ꢀꢁ Clean the air filter as recommended in the  
“care and cleaning” section.  
Wear and Tear  
ꢀꢁ Proper insulation and weather stripping in  
your home will help limit cool air loss.  
ꢀꢁ External house shading with trees, plants, or  
awnings helps reduce the air conditioner’s  
work load.  
ꢀꢁ Operate heat producing appliances during the  
coolest part of the day. Such as a dish-  
washer, oven, or computer.  
To minimize wear and tear on the air condi-  
tioner, always wait at least 3 minutes before  
changing modes. This will help prevent the  
compressor from overheating and the circuit  
breaker from tripping.  
Winter Storage  
To store the air conditioner when it is not in use  
for an extended period of time, remove it care-  
fully from the window according to the installation  
instructions and cover it with plastic or place it in  
the original box.  
13  
TROUBLESHOOTING  
PROBLEM  
POSSIBLE CAUSES  
SOLUTIONS  
The Air Conditioner will not start  
The air conditioner is unplugged  
ꢀꢁ Make sure the air conditioner is  
plug is pushed completely into the  
outlet  
ꢀꢁ Check the house fuse/circuit  
breaker box and replace the fuse  
or reset the breaker.  
The fuse is blown/circuit breaker is  
tripped.  
ꢀꢁ The unit will automatically re-start  
when power is restored.  
Power Failure  
ꢀꢁ There is a protective time delay  
(approx. 3 minutes) to prevent  
tripping of the compressor  
overload. For this reason, the unit  
may not start normal cooling for 3  
minutes after it is turned back on.  
ꢀꢁ Press the RESET button located  
on the power cord plug.  
ꢀꢁ If the RESET button will not stay  
engaged, discontinue use of the  
air conditioner and contact a  
qualified service technician.  
The current interrupter device is  
tripped.  
The Air Conditioner does not cool  
as it should  
Airflow is restricted  
ꢀꢁ Make sure there are no curtains,  
blinds, or furniture blocking the  
front of the air conditioner  
ꢀꢁ Lower the set thermostat tempera-  
The temperature control may not be  
set correctly.  
ture  
The air filter is dirty  
ꢀꢁ Clean the filter. See the Cleaning  
and Care Section of the manual.  
ꢀꢁ Please allow time for the room to  
cool down after turning on the air  
conditioner.  
The room may be too warm  
ꢀꢁ Check for open furnace registers  
Cold air is escaping  
and cold air returns  
The Cooling Coils are frozen  
ꢀꢁ See “Air Conditioner Freezing Up”  
below.  
The Air Conditioner is freezing up  
Ice blocks the air flow and stops the air  
conditioner from cooling the room  
ꢀꢁ Set the MODE dial to HIGH FAN  
or HIGH COOL and set the ther-  
mostat to a higher temperature  
The Remote Control is not working The batteries are inserted incorrectly  
ꢀꢁ Check the position of the batteries.  
The batteries may be dead  
ꢀꢁ Replace the batteries  
14  
TROUBLESHOOTING (CONT.)  
PROBLEM  
POSSIBLE CAUSES  
SOLUTIONS  
Water is dripping outside  
Hot and Humid weather.  
ꢀꢁ This is normal  
Water is dripping inside the room  
The air conditioner is not correctly  
tilted outside.  
ꢀꢁ For proper water drainage, make  
sure the air conditioner is slightly  
tilted downward from the front of  
the unit to the rear.  
Water collects in the base pan  
Moisture removed from the air is  
draining into the base pan.  
ꢀꢁ This is normal for a short period in  
areas with low humidity and nor-  
mal for a longer period in areas  
with high humidity.  
The Air Conditioner Display reads  
A Sensor has failed in the air  
conditioner  
ꢀꢁ Contact customer service  
ꢀꢁ Contact customer service  
ꢀꢁ Contact customer service  
ꢀꢁ Contact customer service  
F1”  
The Air Conditioner Display reads  
F2”  
A Sensor has failed in the air  
conditioner  
The Air Conditioner Display reads  
F4”  
A Sensor has failed in the air  
conditioner  
The Air Conditioner Display reads  
FJ”  
A Sensor has failed in the air  
conditioner  
15  
WARRANTY  
One Year Limited Warranty  
Soleus International, Inc. warrants the accompanying Soleus Air Powered by Gree Air Conditioner to be free of defects  
in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year  
from the date of original retail purchase in the United States.  
If the unit exhibits a defect in normal use, Soleus International will, at its option, either repair or replace it, free of  
charge within a reasonable time after the unit is returned during the warranty period.  
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a  
copy of the original purchase invoice.  
THIS WARRANTY DOES NOT COVER:  
ꢀꢁ Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in  
material or workmanship.  
ꢀꢁ Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions  
in the instructions.  
ꢀꢁ Damage to the finish of the case, or other appearance parts caused by wear.  
ꢀꢁ Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-  
tional Inc.  
ꢀꢁ Freight and Insurance cost for the warranty service.  
ꢀꢁ Filter and Accessories  
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO  
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.  
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT  
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR  
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.  
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-  
vaged, or refurbished products.  
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow  
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you  
specific legal rights, and you may also have other rights that vary from state to state.  
For Technical Support and Warranty Service  
Please Call (888) 876-5387  
Or Write To:  
Soleus International, Inc.  
20035 E. Walnut Dr. N.  
City of Industry, CA 91789  
16  
66129903750  

Panasonic Cu E21fkr User Manual
Samsung Clp 600 User Manual
Samsung Uq09a5 6 Maf User Manual
Sanyo C4232a User Manual
Sanyo Stb0810c1 User Manual
Schumacher Sc 6000a User Manual
Sharp True Hepa Replacement Filter Fzc150hfu User Manual
Thermax 8510 User Manual
Toshiba E Studio28 User Manual
Xerox Phaser 3155 User Manual