Quadra
Silent Air Purifier
SI867 Instructions
INCLUDES IMPORTANT
SAFETY INFORMATION.
READ ALL INSTRUCTIONS
BEFORE USING THIS APPLIANCE.
SAVE THESE INSTRUCTIONS.
Table of Contents
Warnings ...................................................................................4
Important Information - Please Read ......................................6
Frequently Asked Questions...................................................7
OzoneGuard™.......................................................................8
General Instructions...................................................................9
Setup and Operation..............................................................9
Cleaning the Collection Grid................................................11
Thorough Cleaning...............................................................12
Additional Information.........................................................13
Statement of FCC Compliance .............................................14
In rooms where candles or oil lamps are frequently burned,
the smoke from these products tend to stick on and around
the Ionic Breeze. Avoid placing the Ionic Breeze in a location
where it will be subjected to smoke from oil lamps or candles.
Warnings
Warning: To reduce the risk of fire, electric shock or injury when
using any electrical appliance, basic precautions should always be
observed, including the following:
•This appliance operates at 110V AC and 50Hz or 60Hz only.
•Connect to a polarized outlet only.
•Plug is polarized with one blade wider than the other. The plug
is only designed to fit in polarized outlet. Do not attempt to
defeat this safety feature.
•Use indoors only.
•Before unplugging the unit from the outlet, turn off all
the controls.
•Do not unplug by pulling the cord. Grasp the plug itself, not the
cord, when unplugging from an outlet.
•Do not handle the plug or appliance with wet hands.
•Unplug from outlet when not in use and before servicing.
•Do not allow the appliance to be used as a toy. Close attention
is necessary when the appliance is operated near children.
•Use only as described in this user manual.
•Do not use if cord or plug appears to be damaged. If the
appliance is not working properly, or has been dropped,
Warnings
damaged, left outdoors or dropped into water, return it to
a service center or to the original place of purchase.
•Do not pull, lift or carry by the power cord. Do not use the cord
as a handle, close a door on the cord, or pull the cord around
or against sharp edges or corners.
•Keep the cord away from heated surfaces.
•A damaged power cord must be replaced by qualified service
personnel only. There are no user-serviceable parts inside the
unit. Any attempt to open the unit will void the warranty and
could lead to serious damage to the unit and/or personal injury
to the user.
•Do not put any object into openings. Do not continue to use
with any opening blocked. Keep all openings free of dust, lint,
hair or anything that may reduce airflow.
•Keep hair, loose clothing, fingers and all parts of the body away
from openings.
•Do not operate the unit in areas where flammable or combus-
tible products or vapors may be present.
READ AND SAVE THESE INSTRUCTIONS
5
Important Information – Please Read
The collection grid has many edges and areas that can trap
water. Ensure the grid is completely dry before re-inserting it into
the unit. If it is not completely dry, the unit could be damaged.
If water is used to clean the grid, allow at least 24 hours for the
collection grid to dry.
This unit should not be located near a fireplace, whether or not
the fireplace is actually in operation. Dust and soot from the
chimney could be rapidly drawn through the air purifier and
deposited on or around the unit.
In any area where this product is subjected to heavy pollution
or smoke, it will be necessary to clean the collection grid
more frequently.
If the unit begins to arc or make a “static-like” sound, turn the
unit off, slide the collection grid out and slowly invert the unit
several times. Replace the grid.
6
Frequently Asked Questions
How often is cleaning required?
Clean the grids at least every two weeks, anytime
The Sharper Image® Quadra® Silent Air Purifier makes a sound
or when the Cleaning Overdue indicator illuminates.
How should it be cleaned?
Wipe the removable collection grid with a damp cloth, paper
towel or sponge. It is very important that the collection grid
be allowed to dry completely before returning it to the
main housing.
What is the clean fresh scent I smell?
3
The scent is ozone, (O ), a combination of three oxygen atoms.
(The U.S. government has set safe standards for ozone and
Sharper Image® Silent Air Purifiers comply with those standards.)
Which power setting should I use?
If the odor of ozone is strong (for instance in a smaller room),
you may prefer to have the power setting on medium or low.
Please read this product instruction manual for impor-
tant safety information and operating instructions.
7
OzoneGuard™
The Sharper Image Quadra was packed with an OzoneGuard
front grill preinstalled. To clean the OzoneGuard and the front
grill, follow the directions for Thorough Cleaning of the front grill.
What does OzoneGuard™ do?
With the OzoneGuard in place, a significant portion of ground-
level ozone inside the air purifier — including any trace levels of
ozone by-product — is converted into oxygen before the cleaned
air circulates back into the room.
Why is the OzoneGuard™ smaller than the grill itself?
The majority of the air output is directed toward the center of the
grill and therefore a larger OzoneGuard isn’t necessary.
Does the air purifier still have the Negative-Ion Feature™ option?
Yes it does. The new OzoneGuard front grill does not affect the
popular Negative-Ion Feature of the air purifier. An emitter at the
bottom of the new grill has replaced the ionizing wires inside the
original grill. The feature itself works the same way as before.
Please read this product instruction manual for impor-
tant safety information and operating instructions.
8
General Instructions
Setup and Operation
Place The Sharper Image Quadra on a
level surface, at least twelve inches from
the wall and furniture. Plug into a polarized
110V outlet. (Read Warnings for details.)
Switch the MODE CONTROL to the
desired setting:
12"
LOW: For small rooms or rooms
where the door is usually closed.
MEDIUM: For average-sized rooms.
Mode Control
HIGH: For large rooms and higher
traffic areas.
These are recommended settings.
Adjust to your own comfort level.
This model features 3 highly charged
collection blades separated by 2 oppositely charged “driver”
blades. This improves the particle capture rate.
9
Setup and Operation
Normal operation at all power
Mode Control
levels involves a programmed
cycle of air movement.
To override the power control
setting and let the unit run at
maximum power for five minutes,
press BOOST.
Boost
Your previously selected power level
resumes after the five minutes has elapsed.
Note: When the unit is on, the negative-ion
feature is always on.
10
Cleaning the Collection Grid
Clean the grid every one or two weeks. As a reminder, the
Cleaning Overdue indicator will turn amber after two weeks. If
the Cleaning Overdue indicator turns red, the unit has shut down
because of excessive dirt or circuitry problems. In many cases, a
thorough cleaning will return the unit to normal operation.
1. Before cleaning, unplug the unit.
Collection Grid
2. Remove the collection grid
by releasing the latch and
pulling the grid from the
top of the unit.
Release-Latch
3. Use a dry or slightly damp
towel or sponge to quickly
wipe the dust from each of
the three collection bars.
4. Before replacing the grid,
invert the entire unit two
or three times.
11
Thorough Cleaning
If the unit makes noise during operation, a thorough cleaning of
the grid, back grill and OzoneGuard front grill may be required.
Note: The OzoneGuard cannot be detached from
the front grill. The OzoneGuard has sharp edges;
use caution when cleaning.
1. Before cleaning, unplug the unit.
2. Release the back grill and the OzoneGuard
front grill by lifting the blue RELEASE-TABS
on the bottom of the grills. Slide up to remove.
3. Use a hair dryer to blow dust from the
interior or a vacuum to remove the dust.
4. The grills can be cleaned with a mild deter-
gent and warm water. Before returning to
Release-Tabs
unit, rinse and allow to dry.
Do not use a dishwasher to clean any part of this unit.
CAUTION: Do not use the product if the ionizing wires are
broken or either grill appears damaged.
To order a replacement grill, call 1-800-344-5555.
12
Additional Information
The exterior of the unit can be cleaned using a cloth or sponge
and a solution of one part household bleach to five parts water or
any bleach-based spray cleaner.
Before plugging the unit back into an outlet, allow the surface to
dry completely.
The unit will not function while the collection grid is removed or
either of the grills are removed.
The majority of collected particles will gather on the removable
stainless steel grid. Over time, debris will accumulate inside the
unit. To access the inside, remove the front and rear grills.
(See section titled “Thorough Cleaning.”)
Sharper Image® Silent Air Purifiers comply with current U.S.
safety requirements for low ozone emissions for consumer
products. We recommend that individuals with a history of
respiratory disease consult with their doctor about possible
heightened sensitivity to very low ozone.
13
Statement of FCC Compliance — Model SI867
WARNING: Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protec-
tion against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communi-
cations. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
14
Statement of FCC Compliance — Model SI867
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician
for assistance.
15
One-Year Warranty
What Is Covered
This warranty covers any defects in materials or workmanship, with the exceptions stated below.
How Long Coverage Lasts
This warranty runs for one year from the date of original purchase.
What Is Not Covered
This warranty does not cover damage caused by misuse or use other than as intended and described
in the product instruction manual, or loss or damage to batteries or removable parts.
What The Sharper Image Will Do
The Sharper Image warrants this product against defects in materials and workmanship. When repair
is not practical, The Sharper Image will have the option to replace the defective product with a fully
warranted, factory-reconditioned product that is the same or has similar functionality.
How to Obtain Service
Return the product and receipt, along with a brief explanation of the problem, to:
T.S.I. - Returns Department
2901-A West 60th Street
Little Rock, AR 72209
If you have questions please feel free to contact our customer service representatives at 1-800-344-5555
or by email at [email protected].
This warranty gives you specific legal rights, and you may have other legal rights that vary from state to state.
© 2006 Sharper Image Corporation
Sharper Image Corporation
350 The Embarcadero, Sixth Floor
San Francisco, CA 94105-1218
Shop online:
Actual product may differ slightly from the product described herein.
V2 11/06
|