BASIC BATTERY LOAD TEST  
(Conventional & Maintenance-Free Types)  
1. Connect clamps to battery posts Red (+) Pos, Black  
(-) Neg and note the battery’s capacity. Engine and all  
electrical accessories must be off when testing battery.  
2. Hold load switch “on” for 10 seconds.  
3. Read meter with load still on then refer to battery  
analysis table on back of Tester.  
COLD TEMPERATURE EFFECTS  
A battery will test lower when cold than when warm. For  
more accurate results, please reduce the battery’s nominal  
rating by 200 cranking amperes (one step on meter scale)  
for each 20°F drop below 40°F. If cranking ampere rating is  
800 and battery temperature is 0°F, test as a 400 cranking  
ampere battery (i.e. 2 steps down).  
TEMPERATURE COMPENSATION  
BATTERY  
+20°F  
0°F  
-20°  
TEMPERATURE  
DECREASE BAT.  
RATING BY:  
1 STEP  
2 STEP  
3 STEP  
1 STEP = 200 Cranking Amps.  
1
BATTERYANALYSIS  
(Meter ReadingAfter 10 Seconds with Load Switch On)  
LOAD TEST  
BATTERY CONDITION  
Good (Green)  
Battery capacity is OK. Battery may or  
may not be fully charged. Check spe-  
cific gravity of battery to determine state  
of charge, check for electrical drain or  
possible charging system trouble. Re-  
charge battery to full level.  
Battery capacity is not satisfactory. Bat-  
tery may be either defective or not fully  
charged. Check specific gravity to de-  
termine which condition exists. If charg-  
ing does not bring specific gravity to full  
charge level, battery should be replaced.  
Weak or Bad,  
But Needle  
Remains Steady  
(Yellow or Red)  
Weak or Bad,  
But Needle  
Battery may be defective or very run  
down. Release load switch and note volt  
Remains Failing meter reaction. Voltage recovery to 12  
(Yellow or Red)  
volt or above within seconds indicates  
defective battery. Slow voltage recovery  
indicates run down condition. For best  
results, check specific gravity.  
2
STARTER MOTOR TEST  
1. Connect clamps to battery posts and do the basic  
battery test. In addition, note the exact voltage with the  
load test on. If voltage continues to fall after 10 seconds,  
this test cannot be preformed.  
2. Apply the voltage obtained above to starter test table  
on the scale plate. In this case, please use the next  
higher minimum cranking volts for the engine of less  
than 200 CID. For example, if load voltage is 11.00,  
use 10.2 for minimum cranking voltage.  
LOAD  
10.2 10.4 10.6 10.8 11.0 11.2 11.4  
VOLTS  
MIM CRANK 7.7  
8.2  
8.7  
9.2  
9.7 10.2 10.6  
VOLTS  
STARTER  
TEST  
3. Disable the ignition system without starting, crank the  
engine and note the voltage.  
4. If cranking voltage of Step 3 is below the minimum  
cranking voltage in starter test table, the starter current  
draw is excessive. If starter cranks slowly, check for  
high resistance or poor connections.  
3
CHARGING SYSTEM TEST  
1. Connect clamps to battery for basic load test.  
2. Operate engine at fast idle.  
3. Note meter reading with all electrical accessories off.  
It should be in green “good” band in “charging system”  
scale.  
4. With headlights and blower motor on high, meter  
should remain in green “good” band.  
5. If meter reads red band or outside the charging system  
zone, trouble is indicated.  
NOTE  
On initial use of your Battery Tester, smoke may  
develop. This is caused by the lubrication burning off  
the heater coils. This will not affect the performance of  
your Battery Tester and will diminish upon further use.  
4
LIMITED WARRANTY  
SCHUMACHER ELECTRIC CORPORATION, 801 BUSINESS CEN-  
TER DRIVE, MOUNT PROSPECT, ILLINOIS 60056-2179 MAKES  
THIS LIMITED WARRANTY TO THE ORIGINAL PURCHASER AT  
RETAIL OF THIS PRODUCT. THIS LIMITED WARRANTY IS NOT  
TRANSFERABLE.  
Schumacher Electric Corporation warrants this battery tester for six  
months from date of purchase at retail against defective material or  
workmanship. If such should occur, the unit will be repaired or re-  
placed at the option of the manufacturer. It is the obligation of the  
purchaser to forward the unit together with proof of purchase, trans-  
portation and/or mailing charges prepaid to the manufacturer or its  
authorized representative.  
This limited warranty is void if the product is misused, subjected to  
careless handling, or repaired by anyone other than the manufac-  
turer or its authorized representative.  
The manufacturer makes no warranty other than this limited war-  
ranty and expressly excludes any implied warranty including any war-  
ranty for consequential damages.  
THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE  
MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANY-  
ONE TOASSUME OR MAKEANY OTHER OBLIGATION TOWARDS  
THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WAR-  
RANTY. THE MANUFACTURER MAKES NO WARRANTY OF MER-  
CHANTABILITY OR FITNESS FOR PURPOSE OF THIS PRODUCT  
AND EXPRESSLY EXCLUDES SUCH FROM THIS LIMITED WAR-  
RANTY.  
SOME STATES DO NOTALLOW THE EXCLUSION OR LIMITATION  
OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LENGTH OF  
IMPLIED WARRANTY SO THE ABOVE LIMITATIONS OR EXCLU-  
SIONS MAY NOT APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTSAND YOU  
MAYALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO  
STATE.  

Painless Performance Vortec 60211 User Manual
Panasonic Cu A9ckp5 User Manual
Panasonic Cu E28gkr User Manual
Samsung Aw0805b User Manual
Savin 9700 User Manual
Sears 2871234 User Manual
Sharp Af 08erl User Manual
Sharp Mx 2600n User Manual
Spt Wa 1400h User Manual
Zebra Technologies 11680100001 User Manual