280-600
ELECTRIC CORP.
801 BUSINESS CENTER DRIVE • MOUNT PROSPECT, ILLINOIS 60056-2179
Send Warranty Product Repairs to: 1025 E. Thompson Ave., Hoopeston, IL 60942-0280.
Call Customer Service if you have questions: 1-800-621-5485
A. IMPORTANT SAFETY INSTRUCTIONS
1. SAVE THESE INSTRUCTIONS - This manual contains important
safety and operating instructions for battery charger Models.
MODELS: #2, CM-1, SE-82-6, SE-83, SE-84, SE-86, SE-1010, SE-1010-2,
SE-1015, MC-1, WS-63, WS-84, WS-86, WS-212, WS-1010, WS-1015,
WS-1020.
Also models SEC-1, SE-82-6, SEC-84, SEC-86, SEC-1010, SEC-1010-2,
SEC-1015,SEC-1020.
ABATTERYCHARGERRECEIVESACPOWERFROMTHEELECTRICOUTLET,AND
DELIVERSDCCURRENTTOTHEBATTERY.
2. Before using battery charger, read all instructions and cautionary markings on (1)
battery charger, (2) battery and (3) product using battery.
3. CAUTION - To reduce risk of injury, charge only lead acid type rechargeable batteries.
Other types of batteries may burst causing personal injury and damage.
4. Use of an attachment not recommended or sold by the battery charger manufacturer
may result in a risk of fire, electric shock, or injury to persons.
5. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when
disconnecting charger.
6. Make sure cord is located so that it will not be stepped on, tripped over, or otherwise
subjected to damage or stress.
7. An extension cord should not be used unless absolutely necessary. Use of improper
extension cord could result in a risk of fire and electric shock. If extension cord must
be used, make sure:
(a) That pins on plug of extension cord are the same number, size and shape as those
of plug on charger;
(b) That extension cord is properly wired and in good electrical condition; and
(c) That wire size is large enough for AC ampere rating of charger as specified below
ACINPUTRATING,AMPERES
AWG SIZE OF CORD
Length of Cord, Feet
Equal to or
but less than
Greater than
25
50 100 150
0
2
3
2
3
4
18
18
18
18 18
18 16
18 16
18
14
14
8. Do not operate charger with damaged cord or plug - replace them immediately.
9. Do not operate charger if It has received a sharp blow, been dropped, or otherwise
damaged in any way; take it to a qualified service man.
10. Do not disassemble charger; take it to a qualified serviceman when service or repair
is required. Incorrect reassembly may result in a risk of electric shock or tire.
11. To reduce risk of electric shock, unplug charger from outlet before attempting any
maintenance or cleaning. Turning off controls will not reduce this risk.
B.
WARNING-RISKOFEXPLOSIVEGASES
1. WORKINGINVICINITYOFALEAD-ACIDBATTERYISDANGEROUS.BATTERIES
GENERATEEXPLOSIVEGASESDURINGNORMALBATTERYOPERATION.FORTHIS
REASON,ITISOFUTMOSTIMPORTANCETHATEACHTIMEBEFOREUSINGYOUR
CHARGER,YOUREADTHISMANUALANDFOLLOWTHEINSTRUCTIONEXACTLY.
Page1
position and removing AC cord from electric outlet. Never allow clips to touch each other.
2. Attach clips to battery posts and twist or rock back and forth several times to make
a good connection. This tends to keep clips from slipping off terminate and helps to reduce
risk of sparking.
G. FOLLOWTHESESTEPSWHENBATTERYISINSTALLEDINVEHICLE.ASPARKNEAR
BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF SPARK NEAR
BATTERY, DO AS FOLLOWS:
1. Position AC and DC cords to reduce risk of damage by hood, door, or moving engine
part.
2. Stay clear of fan blades, belts, pulleys, and other parts that coo cause injury to persons.
3. Check polarity of battery posts. POSITIVE (POS, P. + ) battery post usually has larger
diameter than NEGATIVE (NEG, N. - ) post.
4. Determine which post of battery is grounded (connected to the chassis). If negative
post is grounded to chassis (as in mast vehicles), see #5. If positive post is grounded
to the chassis, see #6.
5. For negative-grounded vehicle, connect POSITIVE (RED) clip from battery charger to
POSITIVE (POS, P. + ) ungrounded post of battery. Connect NEGATIVE (BLACK) clip to
vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel
lines, or sheet-metal body puts. Connect to a heavy gage metal part of the frame or engine
block.
6. For positive-grounded vehicle, connect NEGATIVE (BLACK) clip from battery charger
to NEGATIVE (NEG, N. -) ungrounded post of battery. Connect POSITIVE (RED) clip to
vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel
lines, orsheet-metalbodyparts. Connecttoaheavygagemetalpartoftheframeorengine
block.
7. When disconnecting charger, turn switches to off, disconnect AC cord, remove clip
from vehicle chassis, and then remove clip from battery terminal, in that order.
8. See operating instructions for length of charge information.
H. FOLLOWTHESESTEPSWHENBATTERYISOUTSIDEVEHICLE.ASPARKNEARTHE
BATTERYMAYCAUSEBATTERYEXPLOSION.TOREDUCERISKOFASPARKNEAR
BATTERY, DO AS FOLLOWS:
1. Check polarity of battery posts. POSITIVE (POS, P. + ) battery post usually has a larger
diameter than NEGATIVE (NEG, N. - ) post.
2. Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to NEGATIVE
(NEG, N. - ) battery post.
3. Connect POSITIVE (RED) charger clip to POSITIVE (POS, P. + ) post of battery.
4. Position yourself and free end of cable as far away from battery as possible-then
connect NEGATIVE (BLACK) charger clip to free end of cable.
5. Do not face battery when making final connection.
6. When disconnecting charger, always do so in reverse sequence of connecting
procedure and break first connection while as far away from battery as practical.
7. A marine (boat) battery must be removed and charged on shore. To charge it on board
requires equipment specially designed for marine use.
I. GROUNDINGANDACPOWERCORDCONNECTIONINSTRUCTIONS
Charger should be grounded to reduce risk of electric shock. Charger is equipped with
anelectriccordhavinganequipment-groundingconductorandagroundingplug. Theplug
must be plugged into an outlet that is properly installed and grounded in accordance with
all local codes and ordinances.
DANGER - Never alter AC cord or plug provided - if it will not fit outlet, have proper outlet
Page3
Installed by a qualified electrician. Improper connection can result in a risk of an electric
shock.
This battery charger is for use on a nominal 117-volt circuit, and has a grounding plug
that looks like the plug illustrated In sketch A In Figure 1. A temporary adapter, which looks
like the adapter illustrated in sketches B and C, may be used to connect this plug to a two-
pole receptacle as shown In sketch B if a properly grounded outlet is not available. The
temporary adapter should be used only until a properly grounded outlet can be installed
by a qualified electrician.
DANGER - Before using adapter as illustrated, be certain that center screw of outlet plate
is grounded. The green colored rigid ear or lug extending from adapter must be connected
to a properly grounded outlet - make certain it is grounded. If necessary, replace original
outlet cover plate screw with a longer screw that will secure adapter ear or lug to outlet
cover plate and make ground connection to grounded outlet.
Use of an adapter is not allowed in Canada. It a grounding type receptacle is not available,
do not use this appliance until the proper outlet is installed by a qualified electrician.
FIGURE1
GROUNDINGMETHODS
GROUNDINGOUTLET
ADAPTER
DAPTER
BOX
(C)
GROUNDING
MEANS
(B)
(A)
GROUNDINGPIN
J. OPERATIONINSTRUCTIONS
This battery charger is equipped with a self-resetting circuit breaker. This device protects
the charger from temporary overloads. In the event of an overload, the circuit breaker
will trip open, and after a short cooling off period will reset automatically. This process
is known as cycling and can be recognized by an audible clicking sound.
K. OUTPUTVOLTAGESELECTORSWITCH
Set output voltage selector switch to match voltage of battery to be charged. For models
without voltage selector switch make sure voltage of battery matches that of the charger.
Battery charger models having a voltage selector switch are for charging a 6 or a 12 Volt
battery. Those having no voltage switch are intended for charging a 12 Volt battery only.
Page4
L
OUTPUTCURRENTSELECTORSWITCH
In addition to the voltage selector switch, some models are equipped with a two position
switch, allowing the operator to select the ampere charge rate to a battery, as follows:
MODELS
WS or SE- or SEC-
SWITCHSETTING
82-6
6 or 2 Amps (Trickle)
10 or 2 Amps (Trickle)
15 or 3 Amps (Trickle)
20 or 3 Amps (Trickle)
1010-2
1015
1020
-
Before making any connections to battery, read instructions F, G and H carefulIy.
Connect DC output clips only when AC power supply cord is removed from electrical
outlet.
Never allow cilps to touch each other.
M. CHARGE PERIOD: The approximate required time to bring a battery to full charge state
depends upon the number of ampere hours (AH) depleted from the battery. AH’s are
determined by multiplying the number of hours times the number of Amps supplied by a
battery to a load.
For example - If a load was connected to a battery, which drew 7 Amps for a period of
5 hours, the battery will have supplied 35 AH. The approximate recharge time would then
be calculated by dividing the 35 AH depleted from the battery, by the ampere charge rate
of the charger. To allow for tapering of the charge rate add 25 percent to the charge time.
Indications of a fully charged battery are:
When the ammeter indicates the charge rate has tapered to approximately one half the
charger rated output.
A hydrometer reading of the specific gravity of the electrolyte (fluid) of a battery in good
condition should be between 1.250 and 1.285.
When a battery reaches 80 - 85% of full charge bubbles will appear on the surface of
the fluid. As the battery nears full charge, bubbling will become more noticeably
vigourous.
Disconnecting from Battery:
Before disconnecting from battery read instructions F. G and H carefully.
N. STORAGE: Store battery charger In a dry area.
O. PROBLEMCHECKLIST
1. If no meter reading, check the following:
a. Remove the charger power cord plug from the AC outlet and recheck the battery
charger clips for clean, tight connections.
b. Check voltage selector switch for proper setting.
c. Check for voltage at the AC outlet by plugging in a lamp or other appliance.
2. If Ammeter pointer moves to extreme right, remains a short time, then returns to zero,
accompanied by a cilcking sound, check the following:
a. Possibly, the charger connections are reversed. (Positive to negative, instead of
positive to positive).
Page5
b. A severely discharged, but otherwise good battery. In this situation, the circuit
breaker will continue to cycle and the ammeter pointer will swing from one side
to the other, until the battery has recovered sufficiently to allow a normal charging
rate.
c. A defective battery may cause repeated circuit breaker cycling. A battery in this
condition will not accept a charge and should be replaced.
d. Check voltage switch for proper setting.
3. If charging current Is less than full output rating of the charger, check the following:
a. Perhaps battery is partially charged.
b. Perhaps battery is sulphated and will not accept full charge rate.
c. Perhaps power line is providing low AC supply voltage.
LIMITEDWARRANTY
SCHUMACHER ELECTRIC CORPORATION 801 BUSINESS CENTER DRIVE, MOUNT PROSPECT,
ILLINOIS 60056-2179 MAKES THIS LIMITED WARRANTY TO THE ORIGINAL PURCHASER AT RETAIL
OF THIS PRODUCT. THIS LIMITED WARRANTY IS NOT TRANSFERABLE.
SchumacherElectricCorporationwarrantsthisbatterychargerfortwoyearsfromdateofpurchaseatretailagainst
defective material or workmanship. If such should occur. the unit will be repaired or replaced at the option of the
manufacturerItistheobligationofthepurchasertoforwardtheunittogetherwithproofofpurchase,transportationand/
ormailingchargesprepaidtothemanufactureroritsauthorizedrepresentative.
Thislimitedwarrantyisvoidi~theproductismisusedsubjectedtocarelesshandlingorrepairedbyanyoneotherthan
themanufactureroritsauthorizedrepresentative.
Themanufacturermakesnowarrantyotherthanthislimitedwarrantyandexpresslyexcludesanyimpliedwarranty
includinganywarrantyforconsequentialdamages.
THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR
AUTHORIZESANYONETOASSUMEORMAKEANYOTHEROBLIGATIONTOWARDSTHEPRODUCTOTHER
THAN THIS EXPRESS LIMITED WARRANTY. THE MANUFACTURER MAKES NO WARRANTY OF MER-
CHANTABILITYORFITNESSFORPURPOSEOFTHISPRODUCTANDEXPRESSLYEXCLUDESSUCHFROM
THIS LIMITED WARRANTY.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGESORLENGTHOFIMPLIEDWARRANTYSOTHEABOVELIMITATIONSOREXCLUSIONSMAYNOT
APPLYTOYOU.
THIS WARRANTY GIVES YOU SPECIFIED LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.
Page6
|