Sanyo 42xhw72r User Manual

Print Form  
Split System Submittal Data  
System: 42XHW72R  
Indoor/Outdoor: XHW4272R/CH4272R  
Grille: PNR-XH3642  
Ceiling Recessed Heat Pump  
Job Name:  
Location:  
Approval:  
Date:  
Engineer:  
Construction:  
Unit #:  
Drawing #:  
Submitted to:  
Submitted by:  
Reference:  
General Data (at 230V)  
Power  
Circuit Ampacity  
Fuse Size, Max.  
V/PH/Hz  
(A)  
(A)  
230/208/1/60  
15-40 Indoor-Outdoor  
15-40 Indoor-Outdoor  
Refrigerant  
Lbs. - R410a (outdoor unit)  
Control  
R410A  
7.94  
Electric Expansion Valve  
Compressor  
No. used  
DC Rotary Inverter  
1
Flare  
165  
R.L. Amps - L.R.  
Connection  
(A)  
18.1-31.0  
Line Length, Max (ft.)  
Lift Difference, Max (ft.)  
Line Size  
50 (outdoor lower), 100 (outdoor higher)  
Outdoor Unit  
Fan type  
Dia. (in.) - No. Speeds  
Type Drive - No. Speeds  
No. Poles  
No. Motors  
CFM  
F.L. Amps  
(in. O.D. Discharge)  
(in. O.D. Suction)  
3/8”  
5/8”  
Line Size  
Propeller  
18-7/64-2  
DC Motor  
8 - 830  
2 - 90  
Dimensions  
Indoor Unit  
(in.)  
H x W x D  
(RPM)  
(W)  
(High)  
(Uncrated)  
14-31/64 x 45-9/32 x 33-55/64  
12-13/32 x 44-19/64 x 33-9/32  
48-7/16 x 37 x 13-3/8  
(Crated)  
(Uncrated)  
(Crated)  
3531  
19.7  
Outdoor Unit  
(A)  
52-3/8 x 39-31/32 x 16-3/32  
Aluminum Fin & Copper Pipe  
Coil Type  
Weight  
Net  
Shipping  
Indoor  
Outdoor  
220  
Slit Plate - Inner Rifed  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
(lbs.)  
(lbs.)  
60  
71  
2-12.7  
11.62  
3/8”  
240  
(sq.ft.)  
(in.)  
Tube Size  
Indoor  
10.6  
Outdoor  
19.5  
Shipping Volume  
(cu.ft.)  
Indoor Unit  
Fan type  
Dia. & Length (in.) - No. Speeds  
No. Speeds  
No. Poles  
No. Motors  
Performance Data @ ARI Standard Conditions (230/208V)  
Cooling  
Turbo  
17-7/16-1  
3 & Auto  
Total Capacity  
Sensible Capacity  
Latent Capacity  
SEER  
(BTU/H)  
(BTU/H)  
(BTU/H)  
39,500 (9,500-39,500)  
(RPM, High)  
(W)  
(HI/Med/Lo)  
6 - 506  
1 - 60  
1050/840/720  
23,530  
15,970  
14.6  
CFM  
Indoor Sound Rating  
F.L. Amps  
Dehumidification  
Amps  
Power Inputs  
Outdoor Sound Rating  
(Pints/H)  
(A)  
(W)  
12.6  
(Hi) (dB-A)  
(A)  
45  
1.0  
23.0/25.4  
4,520/4,520  
53  
Coil Type  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area  
Tube Size  
Aluminum Plate Fin & Copper Tube  
Slit Plate - Inner Rifed  
2 - 14.9  
(dB-A)  
Heating  
Total Capacity  
HSPF  
(sq.ft.)  
(in.)  
(in.)  
8.2  
9/32”  
1-17/64  
(BTU/H) 48,000 (8,000-48,000)  
10.4  
Drain Connection Size  

Philips Tea1104t User Manual
Planon System Solutions Docupen Rc850hs User Manual
Psc Falcon 315 User Manual
Ricoh Pro 907ex User Manual
Sanyo Eneloop Mdu01 E 2 3utg User Manual
Schumacher Automatic With Engine Start Sci90 User Manual
Schumacher Speedcharge 300a User Manual
Sharp Fo 2950m User Manual
Toshiba Multifunctional Digital Color Systems 4520c User Manual
Toshiba Rav Sm560at E User Manual