Indoor unit  
Outdoor unit  
AQ07P8GE  
AQ07PBGE  
SH07ZPG  
UQ07P8GE  
UQ07PBGE  
SH07ZPGX  
SH07ZPGAX  
UQ09P8GE  
UQ09PBGE  
SH09ZPGX  
SH09ZPGAX  
UQ12PBGE  
UQ12PGGB  
UQ12PGGE  
SH12ZPGX  
SH12ZPGAX  
UQ18P0GB  
UQ18P0GE  
SH18ZP0X  
SH18ZP0AX  
UQ24P6GB  
UQT24P6GE  
SH24TP6X  
SH24TP6AX  
SH07ZPGA  
AQ09P8GE  
AQ09PBGE  
SH09ZPG  
SH09ZPGA  
AQ12PBGE  
AQ12PGGB  
AQ12PGGE  
SH12ZPG  
SH12ZPGA  
AQ18P0GB  
AQ18P0GE  
SH18ZP0  
SH18ZP0A  
AQ24P6GB  
AQT24P6GE  
SH24TP6  
SH24TP6A  
Split-type Room Air Conditioner (Cool and Heat)  
Aire acondicionado doméstico sistema Split (Refrigeración y Calefacción)  
Climatiseur de type Séparé (Refroidissement et Chauffage)  
Condizionatore daria per ambienti ad unità Separate (Raffreddamento e Riscaldamento)  
Aparelho de ar condicionado tipo Split (Refrigeração e Aquecimento)  
Geteilte raumklimaanlage (Kühlen und Wärmen)  
¢IAIPOYMENO K§IMATI™TIKO ¢øMATIOY(æ‡Í˘ Î·È £¤ÚÌ·ÓÛ˘)  
E S F I P D G DB98-08672A(6)  
Contents  
PREPARING YOUR AIR CONDITIONER  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . . .  
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . . .  
2
4
6
7
8
OPERATING YOUR AIR CONDITIONER  
Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . . . .  
9
Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Heating Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Changing the Room Temperature Quickly . . . . . . . . . . . . . . . . . . 12  
Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Selecting Energy Saving Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
Generating Anion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . . . . . 17  
Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . . . . 17  
PROGRAMMING YOUR AIR CONDITIONER  
Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
RECOMMENDATIONS FOR USE  
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . . . . . 22  
Operating Your Air Conditioner Without the Remote Control . . . . . 22  
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
Cleaning Deodorizing and Bio-Green filters (option) . . . . . . . . . . . 24  
TECHNICAL SPECIFICATIONS  
E-3  
View of the Unit  
The design and shape are subject to change according to the model.  
Indoor Unit  
Room temperature sensor  
Air Inlet  
Auto grille  
On/Off switch  
Air filter  
(under the grille)  
Remote Control Sensor  
Air flow blades  
(outlet)  
Operation indicator  
Set temperature &  
room temperature  
Timer indicator  
Sleep Timer indicator  
Anion indicator  
Fan speed setting  
No t e  
If you want to turn on/off the Display during operation,  
press the button on the remote control.  
The room temperature sensor senses air temperature  
around the sensor, and shows the temperature on the  
display.  
E-4  
Outdoor Unit  
UQ07P8GE  
Air Outlet  
UQ09P8GE  
Air Inlet(Rear)  
SH30ZC1(C2)X  
Connection Valve  
(inside)  
Outdoor Unit  
UQ07PBGE UQ09PBGE UQ12PBGE  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
Outdoor Unit  
SH07ZPGX  
SH07ZPGAX SH09ZPGX SH09ZPGAX  
UQ12PGGB UQ12PGGE SH12ZPGX SH12ZPGAX  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
(inside)  
Outdoor Unit  
UQ18P0GB  
UQ24P6GB  
UQ18P0GE  
UQT24P6GE SH24TP6X  
SH18ZP0X  
SH18ZP0AX  
SH24TP6AX  
Air Inlet(Rear)  
Air Outlet  
Connection Valve  
E-5  
Remote Control - Buttons and Display  
Operating mode  
Remote control  
transmission indicator  
(
AUTO,  
COOL,  
DRY,  
FAN,  
HEAT)  
Battery discharge indicator  
Fan speed  
Turbo mode  
Temperature setting  
Air flow direction  
Anion indicator  
Sleep mode  
Off Timer setting  
Energy saving  
On Timer setting  
On/Off button  
Digital i On/Off button  
Temperature adjustment  
buttons  
Mode selection button  
(AUTO, COOL, DRY, FAN, HEAT)  
Swing button  
Fan speed adjustment  
button  
Energy saving button  
Turbo button  
Anion button  
Sleep button  
On Timer button  
Off Timer button  
Timer Set/Cancel button  
E-6  
Getting Started  
You have just purchased a split type air conditioner and it has been  
installed by your installation specialist.  
Your Owners Instructions contains valuable information on using your  
air conditioner. Please take the time to read it as it will help you take full  
advantage of the units features.  
The booklet is organized as follow s.  
The follow ing figures are show n on pages from 4 to 6 :  
-
-
Indoor and outdoor units  
Rem ote control(buttons and display)  
They w ill help you find the buttons and understand the sym bols displayed.  
In the manual, you will find a series of step-by-step procedures for each  
function available.  
The illustrations in the step-by-step procedures use three different sym bols:  
PRESS  
PUSH  
HOLD DOWN  
E-7  
Inserting the Remote Control Batteries  
You m ust insert or replace the rem ote control batteries w hen :  
You purchase the air conditioner  
The rem ote control does not w ork correctly  
No t e  
Use two AAA, LR03 1.5V batteries.  
Do not use old batteries or different kinds of batteries together.  
Batteries may be completely discharged after 12 months, even  
if they have not actually been used.  
1
2
Push the battery cover on the rear of the remote control with your thumb  
in the direction of the arrow and remove it.  
Insert the two batteries, taking care to respect the polarities :  
+ on the battery with + on the remote control.  
- on the battery with - on the remote control.  
3
Close the cover by sliding it back until it clicks into place.  
E-8  
Selecting the Automatic Operating Mode  
You can start the air conditioner in Autom atic m ode from your rem ote  
control. In the Autom atic m ode, the optim um tem perature and the fan  
speed is selected autom atically.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The operation indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
button.  
The air conditioner runs in AUTO mode.  
No t e  
You can change modes at any time.  
E-9  
Cooling Your Room  
You m ust select the Cool m ode if you w ish to adjust the:  
Cooling tem perature  
Fan speed w hen cooling  
1
If necessary, press the  
(On/Off) button.  
Result: The operation indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in COOL mode.  
button.  
No t e  
You can change modes at any time.  
3
To adjust the temperature, press the  
the required temperature is displayed.  
button one or more times until  
Possible temperatures are between 18°C and 30°C inclusive.  
Result: Each time you press the button:  
- The temperature is adjusted by 1°C  
- The indoor unit beeps  
The air conditioner starts cooling, provided that the room  
temperature is higher than the selected temperature.  
If the room temperature reaches the set temperature, the air  
conditioner stops cooling, but the fan is still operating.  
4
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
Automatic (rotated :  
)
Low  
Medium  
High  
Result:  
Each time you press the  
beeps.  
button, the indoor unit  
5
To control the direction of the air flow, refer to page 17.  
E-10  
Heating Your Room  
You m ust select the Heat m ode if you w ish to adjust the:  
Heating tem perature  
Fan speed w hen heating  
1
If necessary, press the  
(On/Off) button.  
Result: The operation indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
The air conditioner is fitted with a protection mechanism  
to prevent the unit from being damaged when it is started  
immediately after being:  
IMPORTANT  
Plugged in  
Stopped  
It will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control, press the  
button on the remote control one or more times until it appears.  
Result:  
The indoor unit beeps each time you press the  
The air conditioner runs in HEAT mode.  
button.  
No t e  
You can change modes at any time.  
3
To adjust the temperature, press the  
button one or more times  
until the required temperature is displayed.  
Possible temperatures are between 16°C and 30°C inclusive.  
Result: Each time you press the button:  
- The temperature is adjusted by 1°C  
- The indoor unit beeps  
The air conditioner starts heating, provided that the room  
temperature is lower than the desired temperature  
(selected temperature+3°C).  
If the room temperature reaches the set temperature, the air  
conditioner stops heating, but the fan is still operating.  
4
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
)
Automatic (rotated :  
Low  
Medium  
High  
Result:  
Each time you press the  
button, the indoor unit beeps.  
For the first three to five minutes, the fan operates very  
slowly until the air has been sufficiently warmed. Once the  
correct temperature has been reached, the fan is automatically  
set to the required speed.  
5
To control the direction of the air flow, refer to page 17.  
E-11