Samsung Mc26ac2 07 User Manual

OWNERS INSTRUCTIONS  
MANUAL DE INSTRUCCIONES  
MANUEL DUTILISATION  
ISTRUZIONI PER LUSO  
MANUAL DE INSTRUÇÕES  
GEBRAUCHSANWEISUNG  
√¢∏°π∂™ Ã∏™∆∏  
àçëíêìäñàü èéãúáéÇÄíÖãü  
Indoor unit  
Outdoor unit  
AM14B1(B2)E07  
AM18B1(B2)E09  
AM20B1(B2)E06  
AM20B1(B2)E09  
AM26B1(B2)E07  
AM26B1(B2)E12  
AM18B1(B2)B09  
AM26B1(B2)B13  
AM26B1(B2)B13A  
AM27B1(B2)C07  
AM27B1(B2)C13  
MC18AC2-09  
UM14B1(B2)E2  
UM18B1(B2)E2  
UM20B1(B2)E3  
UM26B1(B2)E3  
UM18B1(B2)B2  
UM26B1(B2)B2  
UM26B1(B2)B2A  
UM27B1(B2)C3  
MC18AC2X  
MC19AC2X  
MC24AC2X  
MC26AC2X  
MC19AC2-07  
MC19AC2-12  
MC24AC2-12  
MC26AC2-07  
MC26AC2-12  
MULTI-SPLIT TYPE ROOM AIR CONDITIONER ( Cool )  
ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT ( Refrigeración )  
CLIMATISEUR DE TYPE MULTIPLE ( Refroidissement )  
CONDIZIONATORE DARIA PER PIÙ AMBIENTI AD UNITÀ SEPARATE ( Raffreddamento )  
AR CONDICIONADO MULTI SPLIT ( Refrigeração )  
RAUMKLIMAGERÄT IN MEHRFACH GETEILTER AUSFÜHRUNG ( Kühlen )  
O§Y¢IAIPOYMENO K§IMATI™TIKO ¢øMATIOY( æ‡Í˘ )  
äéåçÄíçõâ ÇéáÑìòçõâ äéçÑàñàéçÖê íàèÄ åìãúíà-ëèãàí ( éı·ʉÂÌË )  
E S F I P D G R DB98-03915A(4)  
Contents  
PREPARING YOUR AIR CONDITIONER  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . 6  
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . 8  
OPERATING YOUR AIR CONDITIONER  
5 Way Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . 10  
Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Changing the Room Temperature Quickly . . . . . . . . . . . . . . . 12  
Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . 15  
Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . 15  
PROGRAMMING YOUR AIR CONDITIONER  
Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
RECOMMENDATIONS FOR USE  
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . 19  
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . 20  
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . 20  
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Installing a Filter (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
TECHNICAL SPECIFICATIONS  
E-3  
View of the Unit  
The design and shape are subject to change according to the model.  
Indoor Unit  
Air Inlet  
Air flow blades (outlet)  
Air filter  
(under the grille)  
Timer indicator  
Remote Control Sensor  
SAVING indicator  
STANDARD indicator  
NATURE indicator  
SILENCE indicator  
POWER indicator  
On/Off & 5 Way  
selection button  
No t e  
For details on the 5 Way, refer to page 9.  
E-4  
MCC2◆  
Indoor Unit  
Air Inlet  
Air flow blades (outlet)  
Air filter  
(under the grille)  
On/Off & 5 Way  
selection button/  
Remote Control Sensor  
TIMER indicator  
STANDARD indicator  
NATURE indicator  
SILENCE indicator  
SAVING indicator  
POWER indicator  
For details on the 5 Way, refer to page 9.  
No t e  
The design and shape are subject to change according to the model.  
Outdoor Unit  
Air Inlet(Rear)  
Air Inlet(Rear)  
Air Outlet  
Air Outlet  
Connection  
Valve  
Connection  
Valve  
E-5  
Remote Control - Buttons and Display  
Remote control  
transmission indicator  
Mode selection button  
(AUTO, COOL, DRY, FAN)  
Operating mode  
(
AUTO,  
COOL,  
DRY,  
FAN)  
Temperature adjustment  
buttons  
Temperature setting  
Turbo mode  
Sleep mode  
Turbo/Sleep mode  
selection button  
Fan speed  
Fan speed adjustment  
button  
Air flow direction  
Swing button  
On Timer setting  
On Timer button  
Off Timer setting  
Off Timer button  
Battery discharge indicator  
On/Off &  
Timer Set/Cancel button  
5 Way selection button  
E-6  
Getting Started  
You have just purchased a split type air conditioner and it has been  
installed by your installation specialist.  
Your Ow ners Instructions contains valuable inform ation on using your  
air conditioner. Please take the tim e to read it as it w ill help you take full  
advantage of the units features.  
The booklet is organized as follow s.  
The follow ing figures are show n on pages from 4 to 6 :  
-
-
Indoor and outdoor units  
Rem ote control(buttons and display)  
They w ill help you find the buttons and understand the sym bols displayed.  
In the m ain part of the installation book, you w ill find a series of  
step-by-step procedures for each function available.  
The illustrations in the step-by-step procedures use three different sym bols:  
PRESS  
PUSH  
HOLD DOWN  
E-7  
Inserting the Remote Control Batteries  
You m ust insert or replace the rem ote control batteries w hen :  
You purchase the air conditioner  
The rem ote control does not w ork correctly  
No t e  
Use two AAA, LR03 1.5V batteries.  
Do not use old batteries or different kinds of batteries together.  
Batteries may be completely discharged after 12 months, even  
if they have not actually been used.  
1
2
Push the battery cover on the rear of the remote control with your thumb  
in the direction of the arrow and remove it.  
Insert the two batteries, taking care to respect the polarities :  
+ on the battery with + on the remote control.  
- on the battery with - on the remote control.  
3
Close the cover by sliding it back until it clicks into place.  
E-8  
5 Way Function  
You can select the 5 Way function with operating mode of the air conditioner for  
more comfortable circumstances. You can use the 5 Way function with the indoor  
unit as well as the remote control. Thus, you can use this function  
even though you have lost your remote control.  
Using with the indoor unit  
1
Press the  
mode.  
(ON/OFF) button one time and then select the desired  
To obtain a(n)...  
Then select...  
Normal operating  
(STANDARD) mode  
Reducing the uncomfortable  
temperature gradually  
(NATURE) mode  
(POWER) mode  
(SAVING) mode  
(SILENCE) mode  
High fan speed  
Compressor run time reduced  
Fan speed reduces as the temperature  
decreases  
MCC2◆  
To obtain a(n)...  
Normal operating  
Then select...  
(STANDARD) mode  
Reducing the uncomfortable  
temperature gradually  
(NATURE) mode  
(POWER) mode  
(SAVING) mode  
(SILENCE) mode  
High fan speed  
Compressor run time reduced  
Fan speed reduces as the temperature  
decreases  
2
To stop the operating, press the  
turn off.  
(ON/OFF) button until all indicators  
No t e  
Even if the air conditioner has been turned on via the ON/OFF  
button on the unit, operations can still be controlled using the  
remote control as usual.  
Selecting with the Remote Control  
To select the 5 Way function with the remote control, press the 5 Way  
button one or more times until the desired mode is selected.  
Each time you press the 5 Way button:  
MCC2◆  
Each 5 Way indicator on the indoor unit lights up in order.  
E-9  
Selecting the Automatic Operating Mode  
You can start the air conditioner in Autom atic m ode from your rem ote  
control. In the Autom atic m ode, the standard tem perature and the  
optim um fan speed is selected autom atically. You can adjust the  
standard tem perature but not the fan speed.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the MODE button on the remote control one or more times until it  
appears.  
Result:  
The indoor unit beeps each time you press the MODE button.  
The air conditioner runs in AUTO mode.  
No t e  
You can change modes at any time.  
3
To adjust the standard temperature (The air conditioner automatically  
set the standard temperature by the current room temperature.),  
press the TEMPERATURE buttons one or more times.  
SET TEMP. SET TEMP.  
-2°C -1°C  
< When you feel hot >  
-
SET TEMP. SET TEMP.  
+1°C +2°C  
< When you feel chilly >  
Standard temperature  
E-10  
Cooling Your Room  
You m ust select the Cool m ode if you w ish to adjust the:  
Cooling tem perature  
Fan speed w hen cooling  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected  
when the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control,  
press the MODE button on the remote control one or more times until it  
appears.  
Result:  
The indoor unit beeps each time you press the MODE button.  
The air conditioner runs in COOL mode.  
No t e  
You can change modes at any time.  
3
To adjust the temperature, press the TEMPERATURE buttons one or  
more times until the required temperature is displayed.  
Possible temperatures are between 18°C and 30°C inclusive.  
Result:  
Each time you press the TEMPERATURE buttons:  
- The temperature is adjusted by 1°C  
- The indoor unit beeps  
The air conditioner starts cooling, provided that the room  
temperature is higher than the selected temperature;  
the fan will, however, operate.  
4
Select the fan speed by pressing the FAN button one or more times  
until the required setting is displayed:  
Automatic (rotated :  
)
Low  
Medium  
High  
Result:  
Each time you press the FAN button, the indoor unit beeps.  
5
To control the direction of the air flow, refer to page 15.  
E-11  
Changing the Room Temperature Quickly  
The Turbo cooling function is used to cool your room as quickly as possible.  
Exa m p le :  
You have just com e hom e and find that the room is very  
hot. You w ish to cool it dow n as quickly as possible.  
The Turbo function operates for 30 minutes with the maximum settings before  
returning automatically to the mode and temperature previously selected.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when the unit  
was last used.  
The indoor unit beeps.  
2
Press the  
Result:  
button.  
The temperature and fan settings are adjusted automatically.  
The air conditioner cools the room as quickly as possible.  
After 30 minutes, the air conditioner is reset automatically to the  
previous mode, temperature and fan settings.  
But, if you press the  
button in DRY or FAN mode,  
it will change to AUTO mode automatically.  
3
If you wish to stop the Turbo function before the end of the 30-minute period,  
press the  
button one or more times until  
or  
disappears.  
Result:  
The air conditioner is reset automatically to the previous mode,  
temperature and fan settings.  
4
To control the direction of the air flow, refer to page 15.  
E-12  
Removing Excess Humidity  
If the atm osphere in your room is very hum id or dam p, you can  
rem ove excess hum idity w ithout low ering the room tem perature too  
m uch.  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
IMPORTANT  
The air conditioner is fitted with a protection mechanism  
to prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
It will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control, press the  
MODE button on the remote control one or more times until it appears.  
Result:  
The indoor unit beeps each time you press the MODE button.  
The air conditioner runs in DRY mode.  
No t e You can change modes at any time.  
3
To adjust the temperature, press the TEMPERATURE buttons one or  
more times until the required temperature is displayed.  
Possible temperatures are between 18°C and 30°C inclusive.  
Result: Each time you press the TEMPERATURE buttons:  
- The temperature is adjusted by 1°C  
- The indoor unit beeps  
The air conditioner starts removing the excess humidity;  
the quantity of air is adjusted automatically.  
4
To control the direction of the air flow, refer to page 15.  
E-13  
Airing Your Room  
If the atm osphere in your room is stale, you can air the room using  
the Fan feature.  
1
If necessary, press the  
(On/Off) button.  
Result: The 5 Way indicator on the indoor unit lights up.  
The air conditioner starts up in the mode selected when  
the unit was last used.  
The indoor unit beeps.  
2
If the  
is not displayed at the top of the remote control,  
press the MODE button on the remote control one or more times until it  
appears.  
Result:  
The indoor unit beeps each time you press the MODE button.  
The air conditioner runs in FAN mode.  
The temperature is set automatically.  
No t e  
You can change modes at any time.  
3
Select the fan speed by pressing the FAN button one or more times  
until the required setting is displayed:  
Low  
Medium  
High  
Result: Each time you press the FAN button, the indoor unit beeps.  
4
To control the direction of the air flow, refer to page 15.  
E-14  
Adjusting the Air Flow Direction Vertically  
Depending on the position of the indoor unit on the wall of your room, you  
can adjust the position of the outer air flow blade on the bottom of the unit,  
thus increasing the efficiency of the air conditioner.  
1
Press the SWING button one or more times as required.  
Result: The outer blade is adjusted vertically.  
RECOMMENDATION  
When...  
Adjust the blade to face...  
Cooling  
Upwards.  
2
If you want the blade to move up and down automatically when the air  
conditioner is operating, press the SWING button.  
Result: The blade move up and down, around the base position set.  
3
To stop the blade moving up and down, press the SWING button again.  
No t e  
If you switch the air conditioner... Then the blade is...  
Off  
Closed completely.  
On again  
Set to the initial position powered.  
Adjusting the Air Flow Direction Horizontally  
There are tw o sets of inner air flow blades. J ust as the outer air flow  
blade can be adjusted vertically, the inner blades can be adjusted  
horizontally.  
1
Adjust each set of inner blades to the required position, by pushing or  
pulling them sideways.  
The design and shape are subject  
to change according to the model.  
E-15  
Setting the On Timer  
The On Timer enables you to sw itch on the air conditioner automatically  
after a given period of time. You can set the period of time from  
30 minutes to 24 hours.  
1
To set the operating time, press the ON TIMER button one or more times  
until the required time is displayed. Possible time is between 0.5 hour and  
24 hour inclusive.  
2
Press the  
(Set/Cancel) button to complete the setting.  
Result: The remaining time is displayed.  
Blinking of the timer indicator stops.  
The selected mode and the temperature on the display  
disappear after 10 seconds.  
The air conditioner will switch on automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the On timer setting.  
3
To select an operating mode in advance, press the  
button until the  
desired mode is displayed at the top of the remote control.  
Result: The air conditioner will run in the selected mode when it is  
turned on.  
To Cancel the On Timer  
1
To cancel the On Timer, press the ON TIMER button one or more times  
until the timer setting disappears.  
2
Press the  
(Set/Cancel) button.  
No t e  
If you want to turn on the air conditioner before the timer reaches  
the setting time, press the (ON/OFF) button.  
E-16  
Setting the Off Timer  
The Off Timer enables you to switch off the air conditioner automatically  
after a given period of time. You can set the period of time from  
30 minutes to 24 hours.  
1
To set the operating time, press the OFF TIMER button one or more times  
until the required time is displayed. Possible time is between 0.5 hour and  
24 hour inclusive.  
2
Press the  
(Set/Cancel) button to complete the setting.  
Result: The remaining time is displayed.  
Blinking of the timer indicator stops.  
The air conditioner will switch off automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the Off timer setting.  
Exam ple If you would like to turn the air conditioner on after 2 hours  
and to operate it for 2 hours:  
1. Press the ON TIMER button until ‘2.0 Hr’ is displayed.  
2. Press the (Set/Cancel) button.  
3. Press the OFF TIMER button until ‘4.0 Hr’ is displayed.  
4. Press the (Set/Cancel) button.  
No t e  
You can see or change the setting mode and/or the temperature  
by pressing the MODE button or the TEMPERATURE buttons  
after setting the Off timer.  
To Cancel the Off Timer  
1
To cancel the Off Timer, press the OFF TIMER button one or more times  
until the timer setting disappears.  
2
Press the  
(Set/Cancel) button.  
No t e  
If you want to turn off the air conditioner before the timer reaches  
the setting time, press the  
(ON/OFF) button.  
E-17  
Setting the Sleep Timer  
The Sleep Tim er can be used w hen you are cooling your room to  
sw itch the air conditioner off autom atically after a period of six  
hours.  
No t e  
If you w ish to sw itch the unit off at a specific tim e,  
refer to page 17.  
1
2
If the  
is not displayed at the top of the remote control,  
press the MODE button on the remote control one or more times until it  
appears.  
Press the  
button one or more times until  
appears on the  
remote control.  
Result: The indoor unit beeps.  
The air conditioner will be controlled as indicated in the  
illustrations below.  
Cooling The desired temperature is  
increased by 1°C every hour.  
When it has been increased  
by 2°C (after two hours), the  
temperature is maintained for  
four hours.  
To Cancel the Sleep Timer  
If you no longer w ish to use the Sleep Tim er that you have set, you  
can cancel it at any tim e.  
Press the  
Result:  
button.  
The indoor unit beeps.  
The  
The air conditioner operates normally.  
is no longer displayed.  
E-18  
Operating Recommendations  
Here is a recom m endation that you should follow w hen using your  
air conditioner.  
Topic  
Recommendation  
Power failure  
If a power failure occurs when the air conditioner is  
operating, the unit is switched off.  
When the power returns,  
you must press the (ON/OFF)  
button to restart it.  
◆◆B1◆  
the air conditioner starts up  
again automatically  
◆◆B2◆  
◆◆C2◆  
No t e  
Be sure which model you have purchased because some  
air conditioners do not restart automatically.  
E-19  
Temperature and Humidity Ranges  
The following table indicates the temperature and humidity ranges within which the air conditioner can be used.  
If the air conditioner is used at...  
Then...  
High temperatures  
The automatic protection feature may be triggered and the air conditioner stopped.  
Low temperatures  
A water leak or some other malfunction may occur if the heat exchanger freezes.  
High humidity levels  
Water may condense on and drip from the surface of the indoor unit if it is used for long periods.  
Mode  
Outdoor Temperature  
Indoor Temperature  
Indoor Humidity  
Cooling  
Drying  
21°C to 43°C approx.  
18°C to 43°C approx.  
18°C to 32°C approx.  
18°C to 32°C approx.  
80% or less  
-
◆◆ If the cooling operation is used at over 33°C(indoor temperature) then, it does not cool as its full capacity.  
Cleaning Your Air Conditioner  
To get the best possible use out of your air conditioner, you m ust  
clean it regularly to rem ove the dust that accum ulates on the air filter.  
Before cleaning your air conditioner, ensure that you  
have sw itched off the breaker used for the unit.  
IMPORTANT  
1
Open the front grille by pulling on the tabs on the lower right and left  
sides of the indoor unit.  
2
3
Disassemble the front grille by pulling it forwards.  
Hold the edge of the air filter under the front grille and pull to release  
them.  
4
5
Remove all dust on the air filters with a vacuum cleaner or brush.  
Clean the front panel with a damp cloth and mild detergent  
(do NOT use benzene, solvents or other chemicals).  
6
Reassemble the air filters and the front grille.  
Not e  
◆◆ If you have not used the air conditioner for a long period of time,  
set the fan going for three to four hours to dry the inside of the  
air conditioner thoroughly.  
E-20  
Solving Common Problems  
Before contacting the after-sales service, perform the follow ing sim ple checks.  
They m ay save you the tim e and expense of an unnecessary call.  
Problem  
Explanation/Solution  
The air conditioner does not  
operate at all  
Check that the breaker used for the air conditioner is switched on.  
Check that the 5 Way indicator on the indoor unit is on;  
if necessary press the  
(On/Off) button on the remote control.  
Check whether the TIMER indicator on the indoor unit is switched on.  
If so:  
- Wait until the switch-on time is reached and the air conditioner starts  
up automatically  
- Cancel the timer (see pages 16 and 17 for further details)  
The air conditioner does not  
operate with the remote control  
Check that there are no obstacles between you and the indoor unit.  
Check the remote control batteries.  
Check that you are close enough to the indoor unit (seven metres/  
yards or less).  
No beep is heard when you press  
Check that you are pointing the remote control at the remote control  
sensor in the right of the indoor unit.  
the  
(On/Off) on the remote  
control  
Replace the remote control batteries if necessary.  
The air conditioner does not cool  
Check that the correct operating mode has been selected (AUTO,  
COOL).  
The room temperature may be too low.  
Dust may be blocking the air filter guard; refer to page 20 for cleaning  
instructions.  
Check that there is no obstacle in front of the outdoor unit.  
The fan speed does not change  
when you press the FAN button  
Check that the operating mode is set to COOL or FAN ; in the  
AUTO mode, the fan speed changes automatically and in the  
DRY mode, it is set to AUTO.  
The air flow direction does not  
change when you press the  
SWING button  
Check that the air conditioner has been switched on; if necessary,  
press the  
(On/Off) button on the remote control.  
The timer is not correctly triggered  
Check that the timer has been programmed correctly;  
see pages 16 and 17.  
Odours are permeated in the room Air the room.  
during air conditioning  
E-21  
Installing a Filter (Option)  
The air conditioner can be fitted w ith a deodorizing and Bio-Pure  
filter to rem ove m inute dust particles or odours. The service life of  
the filter is approxim ately three m onths depending on the tim e  
during w hich the air conditioner is used.  
1
Remove the vinyl packing from the filter.  
No t e  
Do not remove the packing from a deodorizing filter until you  
wish to use the filter, as it will lose its properties.  
Deodorizing  
filter  
2
3
4
Insert the filter in the filter holder and press the three insert tabs until  
you hear a click.  
Bio-Pure Filter  
Open the front grille by pulling on the tabs on the lower right and left  
sides of the indoor unit.  
Take out the existing filter and replace it with the new one.  
E-22  
Technical Specifications  
Indoor unit  
Outdoor unit  
Power Supply  
AM14B1(B2)E07  
AM18B1(B2)E09  
UM14B1(B2)E2  
UM18B1(B2)E2  
AM20B1(B2)E06  
AM20B1(B2)E09  
UM20B1(B2)E3  
AM26B1(B2)E07  
AM26B1(B2)E12  
UM26B1(B2)E3  
MC18AC2X  
220-240V~, 50Hz  
MC18AC2-09  
MC19AC2-07  
MC19AC2-12  
MC19AC2X  
MC24AC2X  
MC24AC2-12  
MC26AC2-07  
MC26AC2-12  
MC26AC2X  
AM18B1(B2)B09  
AM26B1(B2)B13  
AM26B1(B2)B13A  
UM18B1(B2)B2  
UM26B1(B2)B2  
UM26B1(B2)B2A  
220V~, 60Hz  
AM27B1(B2)C07  
AM27B1(B2)C13  
208-230V~, 60Hz  
UM27B1(B2)C3  
E-23  
THIS AIR CONDITIONER IS MANUFACTURED BY:  
ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:  
CE CLIMATISEUR EST FABRIQUE PAR:  
QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA:  
ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR:  
DIESE KLIMAANLAGE IST FABRIZIERT VON:  
AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O:  
ùíéí äéçÑàñàéçÖê àáÉéíéÇãÖç îàêåéâ:  
ELECTRONICS  
Printed in Korea  

Murphy Glow Plug Control Module Gpm92 User Manual
Ryobi 140501001 User Manual
Samsung As12b1 User Manual
Samsung Aw2410c User Manual
Samsung Tipo Ventana Aw0890a User Manual
Samsung Us09a5 A6 Ma User Manual
Sharp Mx 2300n User Manual
Snapper 126t00 User Manual
Stearns X00 User Manual
Wachsmuth Krogmann Mw5798 User Manual