Samsung Aw07lh Series User Manual

AW07LH Series  
AW09LH Series  
Air Conditioner  
user manual  
imagine the possibilities  
Thank you for purchasing this Samsung product.  
To receive more complete service, please  
register your product at  
DB98-30412A  
E
safety information  
To prevent electric shock, disconnect the power before servicing, cleaning, and installing the unit.  
SAFETY INFORMATION  
Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to  
safely and efficiently operate the extensive features and functions of your new appliance.  
Because the following operating instructions cover various models, the characteristics of your air  
conditioner may differ slightly from those described in this manual. If you have questions, call your nearest  
What the icons and signs in this user manual mean:  
Risk of death or serious personal injury.  
WARNING  
Potential risk of personal injury or material damage.  
CAUTION  
To reduce the risk of fire, explosion, electric shock, or personal injury when  
using your air conditioner, follow these basic safety instructions:  
CAUTION  
Do NOT attempt.  
Do NOT disassemble.  
Do NOT touch.  
Follow directions carefully.  
Unplug the power plug from the wall socket.  
Make sure the machine is grounded to prevent electric shock.  
Call the contact center for help.  
Recommended instructions or useful information for use.  
These warning signs are here to prevent injury to you and others.  
Please follow them carefully.  
After reading this section, keep it in a safe place for future reference.  
SEVERE WARNING SIGNS  
Do not cut the power plug and connect to a different power cable.  
Never attempt to lengthen the power cable.  
Potential risk of fire or electric shock.  
Do not yank the power cable and touch the power plug with wet hands.  
Potential risk of fire or electric shock.  
Never use a damaged power plug, power cable, or loosened power  
receptacle.  
Potential risk of fire or electric shock.  
safety information _03  
safety information  
Do not place the air conditioner near hazardous substances or equipment  
that releases free flames to avoid fires, explosions or injuries.  
Do not spray flammable gases such as insecticide near the air conditioner.  
Potential electric shock, fire or unit malfunction.  
Do not block or place items in front of the air conditioner.  
Do not step, hang onto, or place heavy items on the air conditioner.  
Potential risk of personal injury.  
Do not insert anything such as fingers or branches into the air conditioner  
vents.  
Keep children away from the air conditioner.  
Potential risk of personal injury.  
Consult the place of purchase or a contact center to disassemble or reinstall  
the air conditioner.  
Potential risk of unit malfunction, water leakage, electric shock, or fire.  
Consult the place of purchase or a contact center to install the air  
conditioner.  
Improper installation carries a risk of unit malfunction, water leakage, electric shock or  
fire.  
If installing in specialty areas, such as a factory complex or saline coastal area, consult  
the place of purchase or contact center for specific installation details.  
Install the air conditioner with the support bracket securely fastened to use  
for an extended period of time.  
If the air conditioner falls, it may cause personal injury or loss of property.  
Ensure the air conditioner is installed in compliance with current national  
safety standards.  
Use a rated circuit breaker only.  
Never use steel wires or copper wires as a circuit breaker. It may cause fire or unit  
malfunction.  
Use an exclusive power source for the air conditioner.  
Potential risk of electric shock or fire.  
Do not put undue stress on the power cable or place heavy objects on it.  
Do not bend the power cable excessively.  
Potential risk of fire or electric shock.  
If the air conditioner becomes wet, turn off immediately and call your nearest  
contact center.  
Potential risk of fire or electric shock.  
Disconnect the air conditioner from power supply before it is repaired or  
disassembled.  
Use a receptacle that has a ground terminal. The receptacle must be used  
exclusively for the air conditioner.  
Improper electrical grounding may cause electric shock or fire.  
04_ safety information  
CAUTION SIGNS  
Ensure no water gets into the air conditioner.  
Potential risk of fire or electric shock.  
Do not install the air conditioner close to heating appliances to avoid damage.  
Turn off the air conditioner using the provided remote control or control accessory  
(if provided). Do not unplug to turn the unit off (unless there is an immediate  
danger).  
Cool air should not flow directly towards people, pets, and plants.  
It is harmful to your health, pets, and plants.  
Do not run the air conditioner for an extended period of time in a room with  
the door closed or with babies, elderly or disabled people.  
Open the door or windows to ventilate your room at least once an hour to prevent oxygen  
shortage.  
Do not use the air conditioner as a cooling precision instrument for food,  
pets, plants, cosmetics or machinery.  
Potential risk of property loss.  
Do not drink water from the air conditioner.  
Potential risk of health hazard.  
Do not give excessive shock to the air conditioner.  
Potential risk of fire or unit malfunction.  
Do not expose the dust filter to direct sunlight while drying.  
Strong direct sunlight may deform the dust filter.  
Do not spray water directly on the air conditioner or use benzene, thinner, or  
alcohol to clean the surface of the unit.  
Potential risk of electric shock or fire.  
Potential risk of damage to the air conditioner.  
Do not place containers with liquid or other objects on the unit.  
Do not throw the remote control.  
It may break and plastic piece can be dangerous. You may get a cut or greater injury.  
The air conditioner is composed of moving parts. Keep children away from  
the unit to avoid physical injury.  
Check for damage on delivery. If damaged, do not install the air conditioner  
and call the place of purchase immediately.  
Make sure the voltage and frequency of the electric system are compatible  
with the air conditioner.  
Insert the dust filter before operating the air conditioner.  
If there is no dust filter inside the air conditioner, accumulated dust may shorten the life of  
the air conditioner and cause electricity waste.  
Keep indoor temperatures stable and not extremely cold, especially where  
there are children, elderly or disabled people.  
Clean the air conditioner after the inner fan stops operating.  
Potential risk of injury or electric shock.  
Clean the dust filter every 2 weeks. Clean the filter more frequently if the air  
conditioner is operated in dusty areas.  
safety information _05  
safety information  
Inspect the condition, electric connections, pipes and external case of the  
air conditioner regularly by a qualified service technician.  
Do not open doors and windows in the room being cooled during operation  
unless necessary.  
Do not block the air conditioner vents.  
If objects block the air flow, it may cause unit malfunction or poor performance.  
The packaging material and used batteries of the remote control (optional)  
must be disposed of in accordance with the national standards.  
The refrigerant used in the air conditioner must be treated as chemical waste.  
Dispose the refrigerant following national standards.  
Have a qualified service technician install the air conditioner and perform a trial  
operation.  
Ensure the off-on and protection switches are properly installed.  
Do not use the air conditioner if damaged. If problems occur, immediately  
stop operation and disconnect the plug from the power supply.  
If the air conditioner will not be used for an extended period of time (for  
example, over several months), unplug the power from the wall.  
Call the place of purchase or a contact center if repairs are needed.  
Potential risk of fire or electric shock if disassembly or repairs are attempted by  
a non-qualified service technician.  
If you smell burning plastic, hear strange sounds, or see smoke coming from  
the unit, unplug the air conditioner immediately and call a contact center.  
Potential risk of fire or electric shock.  
06_ safety information  
contents  
SETTING UP YOUR AIR CONDITIONER  
BEFORE USE  
08 Checking the parts and the control panel  
08  
08  
09  
10  
11  
11  
Main parts  
Ventilation lever  
Control panel  
Digital display  
Remote control  
Installing the batteries  
08  
12 Selecting operation mode  
OPERATING YOUR AIR COND1ITION2ER  
12  
13  
14  
Cooling  
Air circulation  
Dry  
15 Adjusting air flow direction  
15  
15  
Horizontal air flow  
Vertical air flow  
16 Advanced functions  
16  
17  
18  
19  
On timer  
Off timer  
Good Sleep mode  
Smart Saving mode  
20 Cleaning the exterior  
20 Cleaning the air filter  
20 Maintaining the air conditioner  
CLEANING AND MAINTAINING YOUR  
AIR COND2ITION0ER  
21 Troubleshooting  
21 Operation ranges  
APPENDIX  
21  
22 Getting ready to install the air conditioner  
INSTALLING YOUR AIR COND2ITION2ER  
22  
22  
Checking included parts  
Selecting the best location  
23 Setting up the air conditioner  
23 Assembly for drainage  
contents _07  
setting up your air conditioner  
before use  
Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air  
conditioner and stay cool with optimal efficiency.  
Please read the user manual to get started and to make the best use of the air conditioner.  
CHECKING THE PARTS AND THE CONTROL PANEL  
Carefully unpack your air conditioner, and check the unit to make sure it is not damaged.  
Main parts  
Air intake (Inside)  
Air filter (Inside)  
Inner air flow blades  
Air outlet  
Vertical air flow blades  
Air intake (Outside)  
Ventilation lever  
Door  
Control panel  
Power Cable  
Your air conditioner may slightly differ from illustration shown above depending on your  
model.  
Power plug can be different from the illustration shown above depending on your region.  
When you connect the power plug into the receptacle, a beep will sound.  
Ventilation lever  
The ventilation lever is designed to help you get fresh air from outdoors.  
It can also help prevent strong outdoor odors from entering the room  
through the air conditioner. The lever is located on the lower right side  
of the air flow blades.  
Sliding the ventilation lever to the right lets outdoor  
air enter the room, and sliding the lever to the left  
re-circulates existing air within the room.  
Depending on your model, the ventilation lever  
appearance and location may slightly differ.  
08_ setting up  
Control panel  
1
9
8
2
3
7
6
4
5
Sets the timer to turn on/off the air conditioner after elapsing a  
pre-set time automatically.  
Press this button while the air conditioner is off to activate On timer.  
Press this button while the air conditioner is on to activate Off timer.  
1
2
TIMER BUTTON  
In Good Sleep mode, the air conditioner will run for 8 hours at  
the temperature you set before turning off.  
Press this button to activate/deactivate the Good Sleep mode  
when the air conditioner is on.  
GOOD SLEEP  
BUTTON  
This button can bring your air conditioner to energy saving mode.  
Press the button to activate/deactivate the Smart Saver mode  
when the air conditioner is on.  
SMART SAVER  
BUTTON  
3
4
This button adjusts the horizontal air flow direction.  
Press this button to activate/deactivate the inner air flow blade  
movements.  
AIR SWING  
BUTTON  
This button adjusts how much air flows through the air  
conditioner.  
Sets the fan speed to Low/Medium/High.  
FAN SPEED  
BUTTON  
5
6
Turns the air conditioner on and off.  
Short beep will sound twice when air conditioner is turned on.  
Long beep will sound once when air conditioner is turned off.  
POWER  
BUTTON  
REMOTE  
CONTROL  
SENSOR  
7
8
Aim the remote control toward this spot on the air conditioner.  
You can adjust temperature between 18˚C~30˚C in Cool mode.  
- Increases the temperature by 1˚C unit.  
- Decreases the temperature by 1˚C unit.  
TEMPERATURE  
BUTTON  
Sets the operation mode to Cool or Fan .  
Cool - Gets cool air from the air conditioner.  
Fan - Air circulation with no cooling.  
Dry - Removes humidity from the room without changing the  
temperature.  
MODE BUTTON  
9
setting up _09  
setting up your air conditioner  
before use  
Digital display  
Fan speed  
One of these icons will appear on the display when you press the Fan Speed button on the  
control panel.  
Low fan speed.  
Medium fan speed.  
High fan speed.  
Temperature/Timer reminder  
Temperature/Timer reminder indicates the temperature you have set or the remaining hours left  
in your Timer and the Sleep mode.  
Operating mode  
One of these icons will appear on the display when you press the Mode button on the control  
panel.  
Cool mode is activated.  
Fan mode is activated.  
Timer  
When you activate Timer mode, this icon will appear to let you know that selected mode has  
been set .  
Good Sleep  
When you activate Good Sleep mode, this icon will appear to let you know that selected mode  
has been set .  
Smart Saver  
When you activate Smart Saver mode, this icon will appear to let you know that selected mode  
has been set .  
Dry  
When you activate Dry mode, this icon will appear to let you know that selected mode has been  
set .  
10_ setting up  
Remote control  
Timer  
Temp  
Increases/decreases the  
temperature.  
Sets the timer on/off.  
(See pages 16~17 for instructions.)  
Good Sleep  
Sets the Good Sleep mode on/off.  
(See page 18 for instructions.)  
Fan  
Mode  
Sets the Fan/Cool/Dry/S.Saver mode.  
(See pages 12~14,19 for instructions.)  
Adjusts the fan speed.  
Swing  
Activates/deactivates inner air flow blade  
movements. (See page 15 for instructions.)  
Power  
Turns on/off the air conditioner.  
Installing the batteries  
1. Slide the cover, on  
the rear of the remote  
control, down to open.  
2. Install two AAA  
batteries.  
3. Close the cover by  
sliding it back to its  
original position.  
Check and match the “+”  
and “-” signs accordingly.  
Make sure you have  
installed the batteries in  
correct position.  
You should hear click  
sound when the cover is  
locked properly.  
setting up _11  
operating your air conditioner  
SELECTING OPERATION MODE  
Cooling  
Transform a hot and humid room into a cool haven quickly by closing all unnecessary openings  
such as fireplace dampers, doors, or windows in the room before running the air conditioner to  
increase efficiency and save energy.  
1. Turn on the air conditioner.  
Press the Power  
button on the remote control.  
You will hear a short beep twice and the air  
conditioner is properly on.  
2. Set the operating mode.  
Press the Cool button on the remote control to  
select Cool mode.  
icon will appear on the display.  
3. Set the temperature.  
Press the Temp button on the remote control.  
Press or button to increase or decrease the  
desired temperature.  
You can set the desired temperature between the  
range of 18˚C~ 30˚C in Cool mode.  
You can increase/decrease the temperature by 1˚C unit.  
4. Set the fan speed.  
Press the Low/Med/High button on the remote  
control.  
One of the following icons will appear on the display.  
Low fan speed is activated.  
Medium fan speed is activated.  
High fan speed is activated.  
When you are using the remote control, make sure corresponding icon appears on the  
display.  
If current outside temperatures are much higher than the selected indoor temperature,  
it may take time to bring the inner temperature to the desired coolness.  
Air flow can also be adjusted manually. (See page 15 for instructions.)  
Avoid drastically turning down the temperature. Energy is wasted and the room does not  
cool faster.  
12_ operating  
operating your air conditioner  
SELECTING OPERATION MODE  
Air circulation  
If the room is stuffy and stale, operate your air conditioner in Fan mode. The air conditioner will  
reduce humidity without changing the inner temperature. We recommend using this mode during  
especially humid but cool springdays.  
1. Turn on the air conditioner.  
Press the Power  
button on the remote control.  
You will hear a short beep twice and your air  
conditioner is properly on.  
2. Set the operating mode.  
Press the Fan button on the remote control to  
select Fan mode.  
icon will appear on the display.  
3. Set the fan speed.  
Press the Low/Med/High button on the remote  
control.  
One of the following icons will appear on the display.  
Low fan speed is activated.  
Medium fan speed is activated.  
High fan speed is activated.  
4. Open/block the vents.  
Slide the lever towards  
icon to ventilate the room with  
fresh air and icon to block.  
When you are using the remote control, make sure corresponding icon appears on the  
display.  
Air flow can also be adjusted manually. (See page 15 for instructions.)  
operating _13  
operating your air conditioner  
SELECTING OPERATION MODE  
Dry  
If the atmosphere in your room is very humid or damp,you can remove excess humidity without  
lowering the room temperature too much.  
1. Turn on the air conditioner.  
Press the Power  
button on the remote control.  
You will hear two short beeps and the air  
conditioner will turn on.  
2. Set the operating mode.  
Press the Dry button on the remote control to  
select Dry mode.  
icon will appear on the display.  
3. Set the temperature.  
Press the Temp button on the remote control.  
Press or button to increase or decrease the  
desired temperature.  
You can set the desired temperature within the  
range of 18˚C~ 30˚C in Cool mode.  
You can increase/decrease the temperature in 1˚C units.  
When you are using the remote control, make sure corresponding icon appears on the  
display.  
Air flow can also be adjusted manually. (See page 15 for instructions.)  
14_ operating  
ADJUSTING THE AIR FLOW DIRECTION  
Air flow can be directed to your desired position.  
Horizontal air flow  
1. Press the Swing  
icon will appear on the display.  
2. The inner air flow blades move from side to side continuously to circulate the air.  
button on the remote control.  
3. To keep the air flow direction in a constant position, press the Swing  
button on the  
remote control.  
Vertical air flow  
1. Move the vertical air flow blades up or down to the desired direction with your fingers.  
While the air conditioner cools the room, operate the appliance with the blades pointing  
upwards. If the unit operates in Cool mode for an extended period of time with the blades  
pointing downward, moisture may generate from the temperature difference and thus  
carries the risk of electric shock or unit malfunction.  
operating _15  
operating your air conditioner  
ADVANCED FUNCTIONS  
This advanced function allows you to turn on/off your air conditioner automatically even when you are away.  
Simply set the time and your air conditioner will turn on/off automatically even when you are not home.  
On timer  
This function allows you to turn on the air conditioner automatically within the time range of 24  
hours. On timer is only functional when the unit is not operating.  
1. Turn off the air conditioner.  
Press the Power  
button on the remote control.  
2. Set the time you want the air conditioner to turn  
on automatically.  
Press the Timer button on the remote control.  
Each time you press the button, time will increase  
in hourly unit and you can set it up to 24 hours.  
icon will appear on the display.  
3. Set the operating mode.  
Press one of the Mode button to select Cool,  
Fan mode on the remote control.  
• Temperature/Fan speed can also be adjusted. (See page 12~13 for instructions.)  
• After the setup, approximately after 5 seconds, all the other icons will be gone except the  
remaining hour and  
icon.  
To deactivate On timer  
1. Press the Timer button on the remote control  
until you see on the display.  
Timer will be off and the icons will disappear  
momentarily.  
The air conditioner will remain off.  
This function will only work while your air conditioner is off.  
16_ operating  
Off timer  
This function allows you to turn off the air conditioner automatically within the time range of 24  
hours. Off timer is only functional when the unit is operating.  
1. Turn on the air conditioner.  
Press the Power  
button on the remote control.  
2. Set the time you want the air conditioner to turn  
off automatically.  
Press the Timer button on the remote control.  
Each time you press the button, time will increase  
in hourly unit and you can set it up to 24 hours.  
icon will appear on the display.  
Operating mode, Temperature and Fan speed can be adjusted before setting Off timer.  
(See pages 12~13 for instructions.)  
To deactivate Off timer  
1. Press the Timer button on the remote control  
until you see  
on the display.  
Timer will be off and the  
momentarily.  
will disappear  
The display will show its earlier temperature and  
the icons.  
operating _17  
operating your air conditioner  
ADVANCED FUNCTIONS  
Good Sleep mode  
This function will be helpful to enjoy your sleep. Air conditioner will automatically turn off in 8  
hours while the temperature will be set to give you maximum comfort during your sleep.  
1. Turn on the air conditioner.  
Press the Power  
button on the remote control.  
2. Set the Good Sleep mode on.  
Press the Good Sleep button on the remote control.  
The air conditioner will turn off automatically  
in 8 hours.  
will pass through the display then,  
remaining hours will appear on the display.  
icon will appear on the display.  
Operating mode, Temperature and Fan speed can be adjusted before setting Good Sleep  
mode.(See pages 12~13 for instructions.)  
Temperature changes in Good Sleep mode  
Cool mode  
If Good Sleep is selected after switching on the unit ,the air conditioner will run in Cool mode.  
During this period, the temperature displayed is one you set for the Cool mode.If the Good  
Sleep is selected before switch on the unit,the air conditioner starts running in Cool mode  
and the temperature is set to 26 °C.  
To deactivate Good Sleep mode  
1. Press the Good Sleep button on the remote control.  
Good Sleep mode will be canceled.  
The display will show its earlier temperature and  
icons.  
Good Sleep mode is only available in Cool mode.  
Air flow can also be adjusted manually. (See page 15 for instructions.)  
18_ operating  
operating your air conditioner  
ADVANCED FUNCTIONS  
Smart Saving mode  
If you wish to save smart when using your Air Conditioner,select the Smart Saving mode.  
1. Turn on the air conditioner.  
Press the Power  
button on the remote control.  
2. Set the Smart Saving mode on.  
Press the S. Saver button on the remote control.  
The S. Saver indicator will light up..  
S.Saver Mode can only be selected in Cool mode. When selecting S.Saver,You can not  
set the desired temperature below 24˚C.  
The fan will run always, while the compressor cycle on and off. When the compressor  
off,the fan will run in low RPM,otherwise the fan will run in previously selecting mode.  
Energy Saving will be more than normal mode.  
To deactivate Smart Saving mode  
Press the S.Saver button on the remote control;  
S.Saver mode will be cancelled and the unit will  
return to the mode you previously selecting(Cool mode).  
Air flow can also be adjusted manually. (See page 15 for instructions.)  
operating _19  
cleaning and maintaining your  
air conditioner  
Keeping your air conditioner clean improves its performance, wards off unnecessary repairs, and lengthens  
its life.  
CLEANING THE EXTERIOR  
1. Wipe the surface of the appliance with a slightly wet or  
dry cloth when needed.  
Do not use Benzene, Thinner or CloroxTM.  
They may damage the surface of the unit and can create  
CAUTION  
a risk of fire.  
CLEANING THE AIR FILTER  
1. Hold the air filter handle, pull it right and out.  
If lift it forward when pull right,the air filter out will be easier.  
2. Vacuum the air filter completely.  
3. Push the air filter back into place.  
Air filter  
For best conditions, repeat every two weeks.  
If the air filter dries in a confined (or humid) area, odors may generate. If this occurs,  
re-clean and dry in a well-ventilated area.  
MAINTAINING THE AIR CONDITIONER  
If the air conditioner will not be used for an extended period of time, dry it thoroughly and disconnect from the wall.  
There may be internal damage if moisture is left in its components.  
1. Before storing the appliance, operate the air conditioner in Fan mode for three to four hours to  
dry the air conditioner completely.  
2. Upon removing from storage, dry the inner components of the air conditioner again by  
running in Fan mode for three to four hours. This helps remove odors which may have  
generated from dampness.  
20_ cleaning and maintaining  
appendix  
TROUBLESHOOTING  
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary  
expenses.  
PROBLEM  
SOLUTION  
The air conditioner  
does not start operating  
immediately after it has  
been restarted.  
Because of the protective mechanism, the appliance does not start  
operating immediately to keep the unit from overloading.  
The air conditioner will start in 3 minutes.  
The air conditioner does Check that the power plug is properly connected. Insert the power plug  
not work at all.  
into the wall socket correctly.  
Check if the circuit breaker is switched off.  
Check if there is a power failure.  
Check your fuse. Make sure it is not blown out.  
The temperature does  
not change.  
Check if your air conditioner to make sure it is not operating in Fan mode.  
The cool air does not  
come out of the air  
conditioner.  
Check if the set temperature is higher than the current temperature. Press  
the Temp button on the remote control or Temp. button on the control  
panel to change the set temperature.  
Press to decrease the temperature.  
Check if the air filter is blocked by dirt. Clean the air filter every two weeks.  
Check if the air conditioner has just been turned on. If so wait 3 minutes.  
Check if the appliance is running in a smoky area or if there is a smell  
entering from outside. Operate the air conditioner in Fan mode or open  
the windows to air out the room.  
Odors permeate in the  
room during operation.  
Check your ventilation lever and make sure it is in  
smell might come in when your ventilation lever is in  
position. Outside  
position.  
The air conditioner  
makes a bubbling sound.  
A bubbling sound may be heard when the refrigerant is circulating through  
the compressor. Let the air conditioner operate in a selected mode.  
The air conditioner  
vibrates excessively  
or makes a lot of noise  
during operation.  
Check if there is a gap between the air conditioner and the wall. Insulate  
the crack securely.  
Water is dripping from  
the air flow blades.  
Check if the air conditioner has been cooling for an extended period of  
time with the air flow blades pointed downwards. Condensation may  
generate due to the difference in temperature. Push the vertical air flow  
blades upward and run the appliance.  
Remote control is not  
working.  
Check if your batteries are depleted.  
Make sure batteries are correctly installed.  
Make sure nothing is blocking the remote control sensor.  
OPERATION RANGES  
The table below indicates the temperature and humidity ranges the air conditioner can be operated within.  
Refer to the table for efficient use.  
OPERATIONAL TEMPERATURE  
MODE  
INDOOR HUMIDITY  
INDOOR  
OUTDOOR  
COOLING  
Approximately 21˚C~32˚C Approximately 21˚C~43˚C  
-
appendix _21  
installing your air conditioner  
GETTING READY TO INSTALL THE AIR CONDITIONER  
First select a room and check conditions prior to installation.  
Checking included parts  
Check that all necessary parts are included. Actual accessories may slightly differ from the  
illustration shown below.  
Gasket  
Drain tube  
Rubber cap  
Screws  
Selecting the best location  
The unit should be level when installed, so that the drainage system and other mechanisms  
operate efficiently. If possible, install the unit in a shaded area on the home’s north or east side.  
Before installation, select a location that fulfills these requirements:  
easy access to control panel.  
away from direct exposure to sunlight.  
adequate ventilation.  
can easily connect to a power source.  
can support the weight of the air conditioner and will not cause increased operating noise  
and vibration.  
where there is no obstacles near the air inlet and outlet.  
the bottom of the unit clears at least 750 mm above ground level.  
Indoor side  
Outdoor side  
awning  
75mm  
min.  
300mm  
145mm  
500mm  
about 3˚  
500mm  
500mm  
<Fence, wall  
or other  
obstacles>  
750mm  
150mm min.  
Outdoor side  
45˚  
45˚  
Indoor side  
If the wall is thicker than 150mm,  
cut the back of the wall at 45°.  
100mm or more  
22_ installing  
installing your air conditioner  
SETTING UP THE AIR CONDITINER  
The air conditioner must be installed horizontally or tilted slightly to the outside for proper water drainage.  
Assembly for drainage  
Once a location has been selected for installation, proper drainage should be established. If the  
drain tube and/or drain hose are not provided, call your nearest contact center.  
1
2
3
1. Attach the gasket  
and the drain tube  
to the base pan hole  
in the rear side of the  
unit with screws  
4
4
REAR SIDE  
1
3
2
5
2. Connect the Rubber Cap  
to the drain tube hole.  
5
On exceptionally hot and humid days the air conditioner may overflow condensed water.  
In hot and high humidity zones, make sure the Rubber Cap have been removed .  
installing _23  
QUESTIONS OR COMMENTS?  
COUNTRY  
CALL  
OR VISIT US ONLINE AT  
1-800-10-SAMSUNG(726-7864)  
1-800-3-SAMSUNG(726-7864)  
02-5805777  
PHILIPPINES  

Lexmark Prestige 805 User Manual
Mitsubishi Electronics Mr Slim Pka A Ga User Manual
Panasonic Cs E21cke User Manual
Panasonic Hq 2051rh User Manual
Samsung Aw0595m User Manual
Sanyo 42th72r User Manual
Shibaura N843 User Manual
Soleus Air Ms 10r User Manual
Tecumseh Th139sa User Manual
Uniden Xca4500 User Manual