Samsung Aw0693l User Manual

OWNER'S  
INSTRUCTIONS  
AW0593L  
AW0693L  
AW0893L  
AW1093L  
AW1293L  
AW1893L  
Window-type Room Air Conditioner  
(Cool)  
E
S
DB98-15117A  
Contents  
PREPARING YOUR AIR CONDITIONER  
Safety Precautions  
2
4
5
6
7
Description of Each Component  
Remote Control - Buttons and display  
Getting Started  
Inserting the Remote Control Batteries  
USING THE CONTROL PANEL ON THE UNIT  
OPERATING YOUR AIR CONDITIONER  
Cooling Your Room  
Airing Your Room  
Removing Excess Humidity  
9
10  
11  
PROGRAMMING YOUR AIR CONDITIONER  
Setting the On Timer  
Setting the Off Timer  
Setting the Sleep Timer  
Selecting Energy Saving mode  
12  
13  
14  
15  
USING THE WIRELESS REMOTE CONTROL  
OPERATING YOUR AIR CONDITIONER  
Cooling Your Room  
Airing Your Room  
Removing Excess Humidity  
17  
18  
19  
PROGRAMMING YOUR AIR CONDITIONER  
Setting the On Timer  
Setting the Off Timer  
Setting the Sleep Timer  
Selecting Energy Saving mode  
Adjusting the Air Flow Direction Horizontally  
Adjusting the Air Flow Direction Vertically  
20  
21  
22  
23  
24  
24  
RECOMMENDATIONS FOR USE  
Temperature and Humidity Ranges  
Cleaning Your Air Conditioner  
Solving Common Problems  
Technical Specifications  
25  
26  
27  
27  
E-3  
Description of Each Component  
The design and shape are subject to  
change.  
Air inlet(outside)  
Outer air flow blades  
(up/down orientation)  
- Except AW0593L  
Inner air flow  
blades (right/left  
orientation)  
Air outlet  
Ventilation lever  
- Except AW0593L  
Air inlet (Inside)  
Air inlet (Outside)  
Air filter (Inside)  
Power plug  
(The type of power plug  
may differ, depending on  
the local power supply.)  
Temperature/Timer/Fan Speed  
Display  
Cooling indicater  
Dry indicater  
Fan indicater  
Mode  
Mode selection button  
(Cool,Fan, Dry)  
Cool/Dry/Fan  
Energy indicater  
Sleep indicater  
Timer indicater  
Temp.  
Power  
Energy Saver button  
Sleep timer setting button  
Timer setting button  
E.Saver  
Sleep  
Timer  
Temperature adjustment  
buttons  
On/Off button  
Fan Speed  
Fan speed adjustment button Remote control sensor  
E-4  
Remote Control - Buttons and display  
Remote control  
transmission indicator  
Mode selection button  
(Cool,Fan, Dry)  
Operating mode  
(
Cool, Dry, Fan)  
Temperature adjustment  
buttons  
Temperature setting  
Sleep mode  
Sleep timer setting button  
Energy Saving mode  
Fan speed adjustment  
button  
Fan speed  
Energy Saving button  
On Timer setting  
Off Timer setting  
Timer setting button  
Timer Set/Cancel button  
On/Off button  
Battery discharge indicator  
E-5  
Getting Started  
You have just purchased a Samsung window-type room air condotioner which should be installed  
following your installation manual.  
Your Owner's Instructins contain much valuable information on using your air conditioner.  
Please tade the tine to read then as they will help you take full advantage of the unit's feaatures.  
The booklet is organized as follows.  
The following figures are shown on pages 4 and 5:  
-
-
Description of Each Component  
Remote control(buttons&display)  
They will help you find the buttons and understand the symbols dispalyed.  
In the main part of the document, you will find a series of step-by-step pricedures for  
each function available.  
The illustrationsin the step-by-step procedures use foru different symbols:  
PRESS  
PUSH  
IMPORTANT  
NOTE  
E-  
6
Inserting the Remote Control Batteries  
You must insert or replace the remote control batteries when :  
You purchase the air conditioner  
The remote control does not work correctly  
Use two AAA, LR03 1.5V batteries.  
Do not use old batteries or different kinds of batteries together.  
Batteries may be completely discharged after 12 months, even  
if they have not actually been used.  
1
2
Push the battery cover on the rear of the remote control with your thumb  
in the direction of the arrow and remove it.  
Insert the two batteries, taking care to respect the polarities :  
+ on the battery with + on the remote control.  
- on the battery with - on the remote control.  
3
Close the cover by sliding it back until it clicks into place.  
E-7  
Using the  
Control Panel  
on the Unit  
This chapter indicates how to operate and program  
your air conditioner with the control panel on the unit.  
E-8  
Cooling Your Room  
You must select the Cool mode if you wish to lower the temperature  
in your room. You can also set the Fan speed.  
Control Panel  
Press the  
Result:  
(On/Off) button.  
The air conditioner starts up in the cool mode.  
The unit beeps twice.  
1
Power  
The air conditioner is fitted with a protection mechanism to prevent  
the unit from being damaged when it is started immediately after  
being:  
Plugged in  
Stopped  
It will start up normally after three minutes.  
If the temperature is not displayed on the control panel:  
2
Mode  
Cool/Dry/Fan  
Press the  
button on the unit one or more times until the  
temperature is displayed.  
Mode  
Cool/Dry/Fan  
Result:  
The unit beeps each time you press the  
button.  
The air conditioner starts up in the Cool mode.  
You can chang modes at any time.  
3
To adjust the temperature, press the  
or more times until the desired temperature is displayed.  
The temperature can be set between 64 Fand 86 F.  
or  
buttons on the unit one  
Result:  
Each time you press the  
or  
buttons:  
-The temperature is adjusted by 1 F and displayed on  
the control panel  
-The unit beeps  
The air conditioner starts cooling, if the room temperature is  
higher than the selected temperature.  
If the room temperature reaches the set temperature, the air  
conditioner stops cooling, but the fan is still operating.  
To set the fan speed:  
4
5
Fan Speed  
Press the  
button on the unit one or more times until the  
desired the Fan speed(F1, F2 or F3) is displayed.  
F1:Low  
F2:Medium  
F1:High  
To control the direction of the air flow, refer to page 24.  
E-9  
AiringYourRoom
If you want to provide air circulation without cooling, you can use  
the Fan mode.  
Control Panel  
If necessary, press the  
(On/Off) button.  
1
Result:  
The air conditioner starts up in the cool mode.  
The unit beeps twice.  
Power  
2
If the fan speed(F1, F2 or F3) is not displayed on the control panel:  
Mode  
Cool/Dry/Fan  
Press the  
(F1, F2 or F3) is displayed.  
button on the unit one or more times until the fan speed  
Mode  
Cool/Dry/Fan  
The unit beeps each time you press the  
The air conditioner starts up in the Fan mode.  
button.  
Result:  
You can change modes at any time.  
When the air conditioner is in the Fan mode, the temperature  
cannot be set or displayed.  
F1:Low  
F2:Medium  
F1:High  
3
To set the fan speed:  
Fan Speed  
Press the button on the unit one or more time until the  
desired fan speed(F1, F2 or F3) is displayed.  
F1:Low  
F2:Medium  
F1:High  
To control the direction of the air flow, refer to page 24.  
4
E-10  
Removing Excess Humidity  
If the atmosphere in your room is very humid or damp,you can remove  
excess humidity without lowering the room temperature too much.  
Control Panel  
1
If necessary, press the  
(On/Off) button.  
Power  
Result:  
The air conditioner starts up in the Cool mode.  
The unit beeps twice.  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
It will start up normally after three minutes.  
If the temperature is not displayed on the control panel:  
2
press the  
temperature is displayed.  
Result:  
button the unit one or more times until the  
The unit beeps each time you press the  
button.  
The air conditioner starts up in the cool mode.  
You can change modes at any time.  
To adjust the temperature, press the  
more times until the required temperature is displayed.  
or  
buttons one or  
3
Possible temperatures are between 64 F and 86 F inclusive.  
Result:  
Each time you press the  
or  
buttons:  
- The temperature is adjusted by 1 F  
- The unit beeps  
The air conditioner starts removing the excess humidity;  
the quantity of air is adjusted automatically.  
To control the direction of the air flow, refer to page 24.  
4
E-11  
Setting the On Timer  
The On Timer enables you to switch on the air conditioner automatically after a  
given time, You can select the On Timer only when the air conditioner is off. You  
can select the On timer when the air conditioner operates in the Cool or Dry mode.  
Check that the air conditioner has been switched off; if necessary,  
press the  
1
(On/Off) button.  
Timer  
2
Set the operating time by pressing the  
button on the unit one or  
more times until the desired time is displayed. The operating time can be  
set between 1 and 24 hours.  
Timer  
Result:  
Each time you press the  
buton:  
- The time is adjust by 1 hour and displayed on the control  
panel  
- The unit beeps  
The operating time is displayed and decreases automatically to  
indicate the remaining time.  
The air conditioner starts up in the Cool mode automatically  
when the operating time reaches zero.  
You can select the fan speed, temperature and Energy saving mode  
after setting the On timer and Off timer mode. However, when you  
change the mode, the On timer and Off timer mode is cancelled.  
To Cancel the On Timer  
Timer  
To cancel the timer, press the  
until "--" is displayed.  
button on the unit one or more times  
1
2
Press the  
(On/Off) button on the unit.  
E-  
12  
Setting the Off Timer  
The Off Timer enables you to switch off the air conditioner automatically after a  
given time. You can select the On timer only when the air conditioner is on. You  
can select the Off timer when the air conditioner operates in the Cool or Dry mode.  
Control Panel  
1
Check that the air conditioner has been switched on; if necessary,  
press the (On/Off) button.  
Power  
Timer  
2
Set the operating time by pressing the  
button on the unit one or  
more times until the desired time is displayed. The operating time can be  
set between 1 and 24 hours.  
Timer  
Result:  
Each time you press the  
button:  
- The time is adjusted by 1 hour and displayed on the control  
panel  
- The unit beeps  
The operating time is displayed and decreases automatically to  
indicate the remaining time.  
The air conditioner switches off automatically when the  
operating time reaches zero.  
You can select the fan speed, temperature and Energy saving mode  
after setting the On timer and Off timer mode. However, when you  
change the mode, the On timer and Off timer mode is cancelled.  
To Cancel the Off Timer  
Timer  
To cancel the timer, press the  
times until "--" is displayed.  
button on the unit one or more  
1
2
Press the (On/Off) button on the unit.  
E-13  
Setting the Sleep Timer  
The Sleep Timer can be used when your are cooling your room to switch  
the air conditioner off automatically after 8 hours.  
Control Panel  
If you wish to switch the unit off at a specific time, refer to page 13.  
1
Make sure that you have selected the Cool mode.  
Power  
2
Press the  
Result:  
button on the unit.  
Each time you press a button, the unit beeps.  
The " " will be displayed.  
The remaining time is displayed and decreased by 1 hour  
automatically to indicate the remaining time.  
The air conditioner will be controlled as illustration below  
.
Cooling When the temperature has  
been increased by 2 F  
(after 1 hour), it is maintained  
for 7 hours.  
To Cancel the Sleep Timer  
To cancel the timer, press:  
The  
button on the unit.  
Result:  
The unit beeps.  
The SLEEP indicator is no longer displayed.  
The air conditioner operates in the mode selected last.  
If you select the Energy Saving mode in the Sleep Timer mode,  
the Sleep Timer will be cancelled and the air conditioner will start  
up in the Energy Saving mode.  
E-14  
Selecting Energy Saving Mode  
If the wish to save energy when using your air conditioner,  
select the energy saving mode.  
Control Panel  
1
To select the energy saving mode, press the button on the unit one  
or more times until the Energy Saver indicator lights up.  
Result:  
The fan and compressor cycle on and off together.  
The fan will continue to run for a short time after the  
compressor cycles off.  
If you would like the air conditioner to run in the Dry mode, do not  
button.You cannot use the Dry mode in the energy  
press the  
saving mode.  
Control Panel  
2
To stop the energy saving mode, press the the  
on the unit again.  
button  
Result:  
The fan runs at all times, while the compressor cycles on and off.  
If you select the Sleep Timer in the Energy Saving Mode, the Energy  
Saving will be cancelled and the air conditioner will start up in the  
Sleep Timer mode.  
E-15  
Using the  
Wireless  
Remote  
Control  
This chapter indicates how to operate and program  
your air conditioner with the wireless remote control.  
E-16  
Cooling Your Room  
You must select the Cool mode if you wish to adjust the:  
Cooling temperature  
Fan speed when cooling  
1
If necessary, press the  
(On/Off) button.  
Result:  
The air conditioner starts up in the Cool mode.  
The unit beeps.  
The air conditioner is fitted with a protection mechanism to  
prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
lt will start up normally after three minutes.  
2
If the is not displayed at the top of the remote control,  
press the  
appears.  
button on the remote control one or more times until it  
Result:  
The unit beeps each time you press the  
The air conditioner runs in the Cool mode.  
button.  
You can change modes at any time.  
3
To adjust the temperature, press the buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 64 F and 86 F inclusive.  
Result: Each time you press the buttons:  
- The temperature is adjusted by 1 F  
- The unit beeps  
The air conditioner starts cooling, if the room temperature  
is higher than the selected temperature.  
If the room temperature reaches the set temperature, the air  
conditioner stops cooling, but the fan is still operating.  
4
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
Low  
Medium  
High  
Result:  
Each time you press the  
button, the unit beeps.  
5
To control the direction of the air flow, refer to page 24.  
E-17  
Airing Your Room  
If the atmosphere in your room is stale, you can air the room using  
the Fan feature.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The air conditioner starts up in the Cool mode.  
The unit beeps.  
2
If the is not displayed at the top of the remote control,  
press the button on the remote control one or more times until it  
appears.  
Result:  
The unit beeps each time you press the  
The air conditioner runs in the Fan mode.  
The temperature is set automatically.  
button.  
You can change modes at any time.  
3
Select the fan speed by pressing the  
until the required setting is displayed:  
button one or more times  
Low  
Medium  
High  
Result: Each time you press the  
button, the unit beeps.  
4
To control the direction of the air flow, refer to page 24.  
E-18  
Removing Excess Humidity  
If the atmosphere in your room is very humid or damp, you can remove  
excess humidity without lowering the room temperature too much.  
1
If necessary, press the  
(On/Off) button.  
Result:  
The air conditioner starts up in the Cool mode.  
The unit beeps.  
The air conditioner is fitted with a protection mechanism  
to prevent the unit from being damaged when it is started  
immediately after being:  
Plugged in  
Stopped  
It will start up normally after three minutes.  
2
If the  
is not displayed at the top of the remote control, press the  
button on the remote control one or more times until it appears.  
Result:  
The unit beeps each time you press the  
The air conditioner runs in the Dry mode.  
button.  
You can change modes at any time.  
3
To adjust the temperature, press the  
buttons one or more times  
until the required temperature is displayed.  
Possible temperatures are between 64 F and 86 F inclusive.  
Result: Each time you press the buttons:  
- The temperature is adjusted by 1 F  
- The unit beeps  
The air conditioner starts removing the excess humidity;  
the quantity of air is adjusted automatically.  
4
To control the direction of the air flow, refer to page 24.  
E-19  
Setting the On Timer  
The On Timer enables you to switch on the air conditioner automatically after a  
given time.You can select the On timer only when the air conditioner is off. You  
can select the On timer when the air conditioner operates in the Cool or Dry mode.  
Timer  
button one or more times until  
1
To set the operating time, press the  
the required time is displayed. Possible time is between 1 hour and  
24 hours inclusive.  
2
Press the  
Result:  
(Set/Cancel) button to complete the setting.  
The remaining time is displayed.  
Blinking of the timer indicator stops.  
The air conditioner will switch on automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the On timer setting.  
You can select the fan speed, temperature and Energy saving mode  
after setting the On timer and Off timer mode. However, when you  
change the mode, the On timer and Off timer mode is cancelled.  
To Cancel the On Timer  
1
To cancel the On Timer, press the  
until the timer setting disappears.  
button one or more times  
2
Press the  
(Set/Cancel) button.  
If you want to turn on the air conditioner before the timer reaches  
the setting time, press the (On/Off) button.  
E-20  
Setting the Off Timer  
The Off Timer enables you to switch off the air conditioner automatically after a  
given time.You can select the On timer only when the air conditioner is off. You  
can select the Off timer when the air conditioner operates in the Cool or Dry mode.  
Timer  
button one or more times until  
1
To set the operating time, press the  
the required time is displayed. Possible time is between 1 hour and  
24 hours inclusive.  
2
Press the  
Result:  
(Set/Cancel) button to complete the setting.  
The remaining time is displayed.  
Blinking of the timer indicator stops.  
The air conditioner will switch off automatically when the  
counter displayed on the remote control reaches the set time  
and disappears the Off timer setting.  
You can select the fan speed, temperature and Energy saving mode  
after setting the On timer and Off timer mode. However, when you  
change the mode, the On timer and Off timer mode is cancelled.  
To Cancel the Off Timer  
Timer  
button one or more times  
1
To cancel the Off Timer, press the  
until the timer setting disappears.  
2
Press the  
(Set/Cancel) button.  
If you want to turn off the air conditioner before the timer reaches  
the setting time, press the (On/Off) button.  
E-21  
Setting the Sleep Timer  
The Sleep Timer can be used when you are cooling to switch the air  
conditioner off automatically after a period of 8 hours.  
If you wish to switch the unit off at a specific time, refer to  
page 21.  
1
2
Make sure that you have selected the Cool mode.  
Press the  
Result:  
button on the remote control.  
Each time you press a button, the unit beeps.  
The  
indicator is displayed.  
The remaining time is displayed and decreased by 1 hour  
automatically to indicate the remaining time.  
The air conditioner will be controlled as illustrations below.  
Cooling When the temperature has  
been increased by 2 F  
(after 1 hour), it is maintained  
for 7 hours.  
To Cancel the Sleep Timer  
To cancel the timer press:  
The  
button on the remote control.  
Result:  
The unit beeps.  
The indicator is no longer displayed.  
The air conditioner operates in the mode selected last.  
If you select the Energy Saving mode in the Sleep Timer mode,  
the Sleep Timer will be cancelled and the air conditioner will start  
up in the Energy Saving mode.  
E-22  
Selecting Energy Saving Mode  
If you wish to save energy when using your air conditioner,  
select the energy saving mode.  
To select the energy saving mode, press the  
button on the remote  
1
control one or more times until the Energy Saving indicator lights up.  
Result:  
The fan and compressor cycle on and off together.  
The fan will continue to run for a short time after the  
compressor cycles off.  
If you would like the air conditioner to run in Dry mode, do not press  
the  
button. You cannot use the Dry mode in the Energy Saving  
mode.  
2
To stop the energy saving mode, press the  
control again.  
button on the remote  
Result: The fan runs at all times, while the compressor cycles on and off.  
If you select the Sleep Timer in the Energy Saving mode, the Energy  
Saving will be cancelled and the air conditioner will start up in the  
Sleep Timer mode.  
E-23  
Adjusting the Air Flow Direction Horizontally  
Depending on the position of the unit in your room, you can adjust  
the orientation of the inner air flow blades on the unit.  
Adjust the air flow blades to the desired position by pushing them side to side.  
Adjusting the Air Flow Direction Vertically  
The outer air flow blades can be adjusted to control the vertical air  
flow direction. (Except AW0593L)  
RECOMMENDA  
When...  
Adjust the blades to face...  
Cooling  
Upwards.  
Adjust the air flow blades to the desired position, by pushing them  
upwards or downwards.  
If you orient the air flow blades downwards and the unit operates  
in Cool mode for long periods of time, dew may:  
-
-
Form on the surface of the blades  
Drip from the blades  
E-24  
Temperature and Humidity R anges  
The following table indicates the temperature and humidity ranges  
within which the air conditioner can be used.  
Mode  
Indoor Temperature  
70 F to 90 F approx.  
Outdoor Temperature  
70 F to 110 F approx.  
Indoor Humidity  
80% or less  
C ooling  
If the air conditioner is us ed at... Then...  
Higher temperature  
The automatic protection feature may be triggered and the air  
conditioner stopped.  
Lower temperature  
A water leakage or some other malfunction may happen if the  
heat exchanger freezes.  
Higher humidity levels  
Water may condense on and drip from the surface of the unit  
if it is used for long periods.  
E -25  
CleaningYour Conditioner  
Be sure to clean the air filter periodically to maintain the air conditioner  
in the best condition for a long period of time.  
When cleaning the air conditioner,turn it off and pull out the  
power pulg.  
Open the front grille by pulling the tabs on both sides of the grille.  
Then lift it up slightly to open the front grille completely.  
1
2
3
Grab the tabs on the filter and pull it up and out.  
Remove all dust on the air filter with a vacuum cleaner or brush.  
4
5
When you have finished,insert the air filter back into its original position.  
Wipe the surface of the unit with a neutral detergent  
and then wipe it again with dry cloth.  
(Be sure not to use benzene,solvent or other chemical products.)  
If you...  
Then...  
Will not be using the  
air conditioner for a  
long period of time  
Set the fan going for a few hours to  
dry the inside of the air conditioner  
thoroughly.  
Switch the air conditioner off and  
unplug it from the wall socket.  
Clean the filter and outer surfaces.  
Have not used the air  
conditioner for a long  
period of time  
Set the fan going for a few hours to  
dry the inside of the air conditioner  
thoroughly.  
E-26  
Solving Common Problems  
Before contacting an authorized service center, perform the following simple checks.  
They may save you the time and expense of an unnecessary call.  
Problem  
Explanation / Solution  
Check that the circuit breaker used for the air conditioner has not been  
triggered.  
The air conditioner does  
not operate at all  
Check that the power cable is plugged inot a wall socket and the socket is  
switched on, if necessary.  
Check that the temperature indicator on the unit is lit; if necessary,  
press the  
(On/Off) button on the remote control or unit.  
Check that there are no obstacles between you and the unit.  
Replace the remote control batteries if necessary.  
Check that you are close enough to the unit (seven metres/yards or less).  
The air conditioner does not  
operate with the remote  
control  
Check that you are pointing the remote control at the remote control sensor  
on the unit.  
No beep is heard when you  
press the  
(On/Off) button  
Replace the remote control batteries if necessary.  
on the remote control  
Check that the correct operating mode has been selected(Cool).  
The room temperature may be too low.  
The air conditioner does not  
cool  
Dust may be blocking the air filter; refer to page 26 for cleaning instructions.  
Check that there is no obstacle blocking the air flow into or out of the unit.  
Check that the timer has been programmed correctly;  
refer to page 12~14,20~22.  
The timer is not correctly  
triggered  
Odors are permeating the  
room during air conditioning  
Ventilate the room.  
Technical Specifications  
Design and specifications are subject to change without notice.  
Model  
Power Supply  
AW0593L  
AW0693L  
AW0893L  
AW1093L  
AW1293L  
AW1893L  
115V~, 60Hz  
230-208V~, 60Hz  
E-27  
SAMSUNG ROOM AIR CONDITIONER  
LIMITED WARRANTY TO ORIGINAL PURCHASER  
This SAMSUNG brand product, as supplied and distributed by SAMSUNG ELECTRONICS AMERICA, INC.  
(SAMSUNG) and delivered new, in the original carton to the original consumer purchaser, is warranted by SAMSUNG  
against manufacturing defects in materials and workmanship for a limited warranty period of:  
One (1) Year Parts and Labor, Five (5) Years Parts Warranty for Compressor  
This limited warranty begins on the original date of purchase, and is valid only on products purchased and used in the United  
States.Warranty repairs must be performed by SAMSUNG's authorized service center.To receive warranty service, the original  
dated bill of sale must be presented upon request as proof of purchase to SAMSUNG or SAMSUNG's authorized service center.  
SAMSUNG will repair or replace any part found to be defective at no charge, as stipulated herein, with new or reconditioned parts  
during the limited warranty period specified above.To request warranty service, the purchaser must contact SAMSUNG for  
problem determination and service procedures. SAMSUNG does not warrant uninterrupted or error-free operation of the product.  
All replaced parts and products become the property of SAMSUNG and must be returned to SAMSUNG. Replacement parts and  
products assume the remaining original warranty, or ninety(90) days,whichever is longer.  
In - Home Service (Except AW0593L):  
During the warranty labor period, in-home service will be provided subject to availability within the contiguous United States.  
In-home service is not available in all areas. If during in-home service repair can not be completed, it may be necessary to remove,  
repair and return the product. If in-home service is unavailable, SAMSUNG may elect, at our option, to provide for transportation of  
our choice to and from a SAMSUNG authorized service center. Otherwise, transportation to and from the SAMSUNG authorized  
service center is the responsibility of the purchaser.  
This limited warranty covers manufacturing defects in materials and workmanship encountered in normal, noncommercial use of  
this product and shall not apply to the following, including, but not limited to: delivery and installation; damage which occurs in  
shipment; applications and uses for which this product was not intended; failures or problems which are caused by products or  
equipment not supplied by SAMSUNG; accidents, misuse, abuse, neglect, misapplication, fire, water, lightning or other acts of  
nature; incorrect electrical line voltage, fluctuations or surges; damage caused by improper or faulty installation; product alteration or  
modification; improper or unauthorized repair; cosmetic damage or exterior finish; product with altered serial numbers; failure to  
follow operating and environmental instructions that are covered and prescribed in the instruction book; customer adjustments,  
routine maintenance and cleaning; consumable items such as filters; use of non-SAMSUNG or unauthorized parts, supplies,  
accessories or equipment which damage this product or result in service problems.  
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE LISTED AND DESCRIBED ABOVE, AND NO WARRANTIES  
WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILI-  
TY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY AFTER THE EXPRESS WARRANTY PERIODS STATED  
ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY GIVEN BY ANY PERSON, FIRM OR CORPORATION  
WITH RESPECT TO THIS PRODUCT SHALL BE BINDING ON SAMSUNG. SAMSUNG SHALL NOT BE LIABLE FOR LOSS  
OF REVENUE OR PROFITS, FAILURE TO REALIZE SAVINGS OR OTHER BENEFITS, OR ANY OTHER SPECIAL,  
INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY THE USE, MISUSE OR INABILITY TO USE THIS PRODUCT,  
REGARDLESS OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF SAMSUNG HAS BEEN ADVISED  
OF THE POSSIBILITY OF SUCH DAMAGES. NOR SHALL RECOVERY OF ANY KIND AGAINST SAMSUNG BE GREATER IN  
AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY SAMSUNG AND CAUSING THE ALLEGED  
DAMAGE.WITHOUT LIMITING THE FOREGOING, PURCHASER ASSUMES ALL RISK AND LIABILITY FOR LOSS, DAMAGE  
OR INJURY TO PURCHASER AND PURCHASERS PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF  
THE USE, MISUSE OR INABILITY TO USE THIS PRODUCT SOLD BY SAMSUNG NOT CAUSED DIRECTLY BY THE  
NEGLIGENCE OF SAMSUNG.THIS LIMITED WARRANTY SHALL NOT EXTEND TO ANYONE OTHER THAN THE ORIGINAL  
PURCHASER OF THIS PRODUCT, IS NONTRANSFERABLE AND STATESYOUR EXCLUSIVE REMEDY.  
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or  
consequential damages, so the above limitations or exclusions may not apply to you.This warranty gives you specific legal rights,  
and you may also have other rights which vary from state to state.  
To obtain warranty service, please contact SAMSUNG at:  
SAMSUNG ELECTRONICS AMERICA, INC. - CONSUMER ELECTRONICS CUSTOMER SERVICE  
400 Valley Road, Suite 201 Mount Arlington, NJ 07856  
Tel: 973-601-6000, Fax: 973-601-6001  
1-800-SAMSUNG (1-800-726-7864)  

Lexmark 4039 1xx User Manual
Lexmark Prospect Pro208 User Manual
Panasonic Cs E22jkk User Manual
Precisionaire Gas Turbine Rigid Filters Cell Gt User Manual
Quantum Lc 15000 User Manual
Samsung As18hpbn User Manual
Samsung Aw09p1hba User Manual
Samsung Sgh M610 User Manual
Soleus Air Ky 320 User Manual
York Svy48 Thru 60 User Manual