Samsung Avmbc020ca0 User Manual

OWNER’S INSTRUCTIONS  
MANUAL DE INSTRUCCIONES  
MANUEL D’UTILISATION  
Heat pump  
Cooling only  
AVMBC020CA0  
AVMBC032CA0  
AVMBC040CA0  
AVMBC052CA0  
AVMBC072CA0  
AVMBC020EA(B)0  
AVMBC026EA(B)0  
AVMBC035EA(B)0  
AVMBC052EA(B)0  
AVMBC070EA(B)0  
AVMBH020CA0  
AVMBH032CA0  
AVMBH040CA0  
AVMBH052CA0  
AVMBH072CA0  
AVMBH020EA(B)0  
AVMBH026EA(B)0  
AVMBH035EA(B)0  
AVMBH052EA(B)0  
AVMBH070EA(B)0  
System Air Conditioner  
Aire acondicionado sistemático  
Climatiseur numérique multifonctionnel  
E S F A DB98-06192A(1)  
Contents  
PREPARING YOUR AIR CONDITIONER  
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Wireless Remote Controller-Buttons and Display . . . . . . . . . . . 6  
The Receiver & Display Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Wired Remote Controller-Buttons and Display . . . . . . . . . . . . . 8  
Centralized Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
RECOMMENDATIONS FOR USE  
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . . 11  
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . 12  
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
TECHNICAL SPECIFICATIONS  
E-3  
View of the Unit  
The figures are shown in this instruction may differ from yours depending on the model.  
Indoor Unit  
◆◆020/026/032/035/040◆  
Air  
outlet  
Panel(optional)  
Air  
inlet  
Indoor Unit  
◆◆052/070/072◆  
Air  
outlet  
Panel(optional)  
Air  
inlet  
Air  
inlet  
E-4  
Outdoor Unit TYPE A  
Air outlet  
Connection valve  
Outdoor Unit TYPE B  
Air outlet  
Connection valve  
Air outlet  
Outdoor Unit TYPE C  
Outdoor Unit TYPE D  
Outdoor Unit TYPE E  
Connection valve  
Air outlet  
Connection valve  
Air outlet  
Connection valve  
If the heat exchanger in the outdoor unit gets dusty, cooling efficiency may fall. So clean the heat exchanger with water  
when it becomes dirty. However, be careful when you wash the surface of the heat exchanger because it is very sharp.  
Note  
E-5  
Wireless Remote Controller-Buttons and Display  
The wireless remote controller is an optional accessory.  
To use the wireless remote controller, refer to an appropriate manual.  
Mode selection button  
Operating mode  
Temperature adjustment  
buttons  
Temperature setting  
Filter Reset button  
Fan speed  
Fan speed adjustment  
button  
Air flow direction  
Swing button (Not operated)  
On Timer setting  
On Timer button  
Off Timer setting  
Off Timer button  
Battery discharge indicator  
On/Off & Timer  
Set/Cancel button  
Note  
- After cleaning the air filter, press the filter reset button.  
- Duct type air conditioner does not have function of adjusting air flow direction.  
Therefore, the function is not operated even if you press the swing button.  
- The heating mode( ) is not selected in cooling only models.  
E-6  
The Receiver & Display Unit  
The Receiver & Display unit is an optional accessory and it is installed on the wall.  
To use the receiver & display unit, refer to an appropriate manual.  
Concealed Type  
Filter sign indicator  
Fan indicator  
Timer indicator  
Remote control sensor  
- Heat Pump Models :  
On/Off indicator(Blue) &  
Removing frost  
indicator(Red)  
- Cooling Only Models :  
On/Off indicator  
Standard Type  
Removing frost indicator  
(Except Cooling Only Models)  
Filter sign indicator  
Remote control sensor  
On/Off indicator  
Fan indicator  
On/Off button  
Timer indicator  
E-7  
Wired Remote Controller-Buttons and Display  
The wired remote controller is an optional accessory and it is installed on the wall.  
To use the wired remote controller, refer to an appropriate manual.  
Operating mode  
Removing frost indicator  
(Except Cooling Only Models)  
Centralized controller indicator  
(In case of installing the Centralized controller)  
Communication error indicator  
Temperature setting  
Fan speed  
On Timer setting  
Off Timer setting  
Air flow direction  
Filter Sign indicator  
Test indicator  
On/Off & Timer  
Set/Cancel button  
Temperature adjustment  
buttons  
On/Off indicator  
On Timer button  
Fan speed adjustment  
button  
Off Timer button  
Swing button  
(Not operated)  
Test button  
Filter Reset button  
Mode selection button  
Note  
- Test button is for your installation specialist. You must NOT press it.  
- After cleaning the air filter, press the filter reset button. Then the wired remote  
controller will display the FILTER SIGN indicator when the time to clean the air filter;  
refer to page 12.  
- Duct type air conditioner does not have function of adjusting air flow direction.  
Therefore, the function is not operated even if you press the swing button.  
- The heating mode( ) is not selected in cooling only models.  
E-8  
Centralized Controller  
The centralized controller is an optional accessory and it is installed on the wall.  
To use the centralized controller, refer to an appropriate manual.  
Operating lamp  
All On button  
All Off button  
On/Off indicators  
On/Off buttons  
Index  
Note  
Operating lamp comes on when at least one air conditioner connected to the  
centralized controller is operating.  
E-9  
Operating Recommendations  
Here are a few recommendations that you should follow when operating  
your air conditioner.  
Topic  
Recommendation  
The heat pump function of the air conditioner absorbs heat  
Heating  
performances from outside air and brings it indoors. As the temperature of the  
outside air drops, the heating performance of air conditioner will  
decrease. If you find that the room is not warm enough, using  
an additional heating appliance is recommended.  
Frost  
When outside temperature is low but humidity is high,  
frost may form on the outdoor unit at HEAT mode.  
If this happens:  
The heating operation stops.  
The defrost mode will be triggered automatically for about ten  
minutes.  
No intervention is required ; after about ten minutes, the air  
conditioner operates again normally.  
High indoor  
and outdoor  
If both indoor and outdoor temperatures are high and the air  
conditioner is running at HEAT mode, the outdoor unit’s fan  
temperatures and compressor may stop at times.  
This is normal ; simply wait until the air conditioner switches  
on again.  
Power failure  
If a power failure occurs while the air conditioner is operating,  
the unit will be switched off. When the power returns, the air  
conditioner starts up again automatically.  
E-10  
Temperature and Humidity Ranges  
The following table indicates the temperature and humidity ranges,  
within which the air conditioner can be used.  
If the air conditioner is used at...  
Then...  
High temperature  
The automatic protection feature may be  
triggered and the air conditioner stopped.  
Low temperature  
A water leakage or some other  
malfunction may happen if the heat  
exchanger freezes.  
High humidity levels  
Water may condense on and drip from  
the surface of the indoor unit if it is used  
for a long periods.  
Mode  
Heating  
Cooling  
Drying  
Outdoor Temperature  
-20°C to 24°C approx.  
- 5°C to 43°C approx.  
-5°C to 43°C approx.  
Indoor Temperature  
27°C or less  
Indoor Humidity  
-
21°C to 32°C approx.  
18°C to 32°C approx.  
80% or less  
-
◆◆ If the heating operation is used at below 0°C(outdoor temperature) then,  
it does not heat at its full capacity.  
If the cooling operation is used at over 33°C(indoor temperature) then,  
it does not cool at its full capacity.  
E-11  
Cleaning Your Air Conditioner  
To get the best possible use out of your air conditioner, you must clean  
it regularly to remove the dust that accumulates on the air filter.  
Before cleaning your air conditioner, ensure that you have  
switched off the electric circuit breaker used for the unit.  
IMPORTANT  
Open the front grille by pushing tabs on the grille.  
1
2
Remove the front grille.  
2-1 Remove the safety clips.  
2-2 Open the front grille about 45° and pull it forward.  
Remove a bracket by unfastening the screw.  
3
Note  
◆◆052/070/072models have two brackets.  
Pull out the air filter.  
Note  
In case of 052/070/072models, there are two air filters  
under the grille.  
4
5
Remove all dust on air filter with a vacuum cleaner or a brush. In case of  
serious dust accumulation, put the air filter in warm detergent water and  
shake it vertically.  
Dry the air filter.  
6
7
8
When you have finished, insert the filter into the original position.  
Reinstall the bracket, then close the front grille.  
Note  
After cleaning the air conditioner, press the Filter Reset button.  
Wired Remote Controller  
Wireless Remote Controller  
E-12  
Solving Common Problems  
Before contacting the after-sales service, perform the following simple checks.  
They may save your time and expense of an unnecessary call.  
Problem  
Explanation/Solution  
The air conditioner does not Check that the breaker used for the air conditioner is switched on.  
operate at all  
Wired Remote Controller  
The air conditioner does not  
operate with the remote  
controller  
is displayed on the wired remote controller. In this case,  
turn the air conditioner off and contact your dealer.  
Wired Remote Controller  
When turning on/off the  
air conditioner, it is not  
In case of using the wired remote controller for a group, the air  
conditioners connected to the remote controller are turned on/off in  
order. Thus, it takes some time(up to 32 seconds).  
turned on/off immediately.  
Wireless Remote Controller  
The air conditioner does not Check that there are no obstacles between you and the remote  
operate with the remote  
controller  
control sensor.  
Check the wireless remote controller batteries.  
Check that you are close enough to the remote control sensor.  
(seven metres/yards or less).  
Wireless Remote Controller  
No beep is heard when you Check that you are pointing the remote controller at the remote  
press  
(ON/OFF) on the  
control sensor on the receiver & display unit.  
remote controller  
Replace the remote controller batteries if necessary.  
If there is a strong light around the air conditioner, a  
three-wavelength light, a neon sign, etc., for example,  
the air conditioner may not be operated with a remote controller.  
If this happens, use the remote controller close by the remote  
control sensor.  
The air conditioner does  
not cool or heat  
Check that the correct operating mode has been selected.  
The room temperature may be too low or too high.  
Dust may be blocking the air filter guard; refer to page 12  
for cleaning instructions.  
Check that there is no obstacle in front of the outdoor unit.  
When heating, the required Check that the required temperature has been set correctly.  
room temperature is never  
reached and the air  
Increase the fan speed.  
conditioner frequently stops  
E-13  
Technical Specifications  
Model  
Power Supply  
AVMBH020CA0  
AVMBH032CA0  
AVMBH040CA0  
AVMBH052CA0  
AVMBH072CA0  
1Ø, 208-230V~, 60Hz  
AVMBC020CA0  
AVMBC032CA0  
AVMBC040CA0  
AVMBC052CA0  
AVMBC072CA0  
AVMBH020EA(B)0  
AVMBH026EA(B)0  
AVMBH035EA(B)0  
AVMBH052EA(B)0  
AVMBH070EA(B)0  
1Ø, 220-240V~, 50Hz  
AVMBC020EA(B)0  
AVMBC026EA(B)0  
AVMBC035EA(B)0  
AVMBC052EA(B)0  
AVMBC070EA(B)0  
E-14  
Memo  
E-15  
THIS AIR CONDITIONER IS MANUFACTURED BY:  
ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:  
CE CLIMATISEUR EST FABRIQUE PAR:  
ELECTRONICS  
Printed in Korea  

Nec Xen Digital Voicemail User Manual
Panasonic Cw C200nu User Manual
Panasonic Kx Fl501 User Manual
Ricoh Aficio Sp C232sf User Manual
Royal Sovereign Arp 9409 User Manual
Samsung Clx 6220 User Manual
Toshiba Multifunctional Digital Systems E Studio202l User Manual
Toshiba Rav Sm800xt E User Manual
York Sunline Dhg 060 User Manual
York Ymb User Manual