Royal Sovereign Arp 9409 User Manual

owneR’S ManUal  
aRp-9409, aRp-9411  
aRp-9409 / aRp-9411  
poRtable aIR condItIoneR  
acondIcIonadoR de aIRe poRtÁtIl  
condItIonneUR d' aIRe poRtable  
Página en Español 17  
Page en Français 33  
Read and retain these instructions for future reference.  
For any customer Support needs, please choose the Support tab on  
Royal Sovereign International, Inc  
contentS  
Page  
Precautions for use∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 4  
Identification of parts∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 5  
Installation instructions∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 6~7  
Operation∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 8~11  
Maintenance∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12  
Troubleshooting∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13  
Specifications∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14  
Warranty∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15  
Contact information∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16  
Página en Español∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17  
pRecaUtIonS FoR USe  
electrical Specifications and power cord  
Check to ensure that the electrical service being used is adequate for the model you’ve chosen. The electrical rating of your new air conditioner is  
defined on the serial plate of the unit. Please refer to the rating when checking electrical requirements to ensure they meet the electrical codes of  
your location.  
•∙Install∙the∙air∙conditioner∙according∙to∙the∙installation∙instructions∙supplied.  
•∙Do∙not∙modify∙any∙part∙of∙this∙product.  
•∙Do∙not∙insert∙any∙objects∙into∙the∙product∙or∙block∙the∙airflow∙in∙any∙way.  
•∙Ensure∙that∙the∙power∙supply∙you∙use∙has∙an∙appropriate∙voltage∙rating.  
•∙Only∙use∙a∙properly∙installed∙3∙pin,∙grounded∙AC∙socket∙that∙is∙rated∙115V,∙60Hz,∙15∙amps∙or∙more.  
•∙If∙the∙electrical∙outlet∙you∙intend∙to∙use∙is∙not∙adequately∙grounded∙or∙protected∙by∙a∙time∙delay∙fuse∙or∙circuit∙breaker,∙you∙should∙have∙a∙  
qualified electrician install the proper outlet.  
•∙This∙unit∙uses∙a∙plug∙with∙a∙built-in∙fuse.∙∙Conduct∙a∙Power∙Plug∙Check∙(see∙page∙9)∙before∙use∙to∙confirm∙normal∙operation.  
• Do not use this unit with any extension cords or adapter plugs.  
•∙If∙the∙cord∙or∙plug∙is∙damaged∙in∙any∙way,∙please∙call∙the∙Royal∙Sovereign∙Service∙Department∙(∙see∙page∙16.)  
•∙Do∙not∙plug∙this∙cord∙into∙a∙loose∙electrical∙outlet.  
•∙Turn∙the∙unit∙off∙and∙unplug,∙when∙cleaning∙the∙air∙conditioner,∙removing∙the∙filter∙or∙when∙the∙air∙conditioner∙will∙not∙be∙used∙for∙an∙extended∙time∙period.  
General Use  
•∙Do∙not∙block∙air∙outlets∙or∙intake∙with∙obstacles.  
•∙Do∙not∙insert∙any∙objects∙into∙the∙air∙conditioner.  
•∙Do∙not∙splash∙or∙pour∙water∙on∙the∙housing∙or∙control∙panel.  
•∙Do∙not∙place∙heavy∙items∙or∙sit∙on∙unit.  
•∙Make∙sure∙the∙drainage∙plug∙is∙installed∙on∙bottom∙of∙machine.  
•∙Drain∙the∙unit∙when∙moving∙the∙air∙conditioner∙or∙when∙storing∙the∙unit.  
4
aRp-9409 / 9411  
IdentIFIcatIon oF paRtS  
1. Control panel  
2. Air outlet  
3. Remote control  
4. Handle  
5.∙Exhaust∙hose  
6. Air intake  
7.∙Exhaust∙outlet  
8. Filter  
9. Drain port  
10. Power cord  
11. Power cord hooks  
12. Secondary drain port  
13. Caster wheel  
5
InStallatIon  
Unpack your New Portable Air Conditioner and let the machine stand upright for 2 hours before startin
Unpack all parts listed below. If any parts are missing do not return this product to the place of purch
accessories Include  
1.∙Exhaust∙hose  
2. Hose connector  
3. Hose adapter  
4. Remote control  
5. Water tray  
6. Drainage hose  
7. Window slider  
Part 1: Exhaust hose, connector and adapter  
1.∙Extend∙one∙end∙of∙the∙exhaust∙hose.  
2.∙Take∙the∙hose∙connector∙and∙twist∙it∙counterclockwise∙onto∙one∙end∙ofthe∙exhaust∙hose.  
3.∙Extend∙the∙opposite∙end∙of∙the∙exhaust∙hose.  
4.∙Take∙the∙hose∙adapter∙and∙twist∙it∙counterclockwise∙onto∙the∙unused∙end∙ofthe∙exhaust∙hose.  
Fig 1.  
6
aRp-9409 / 9411  
Part 2: Attaching exhaust hose  
1.∙Hold∙the∙exhaust∙hose∙parallel∙to∙the∙floor∙with∙the∙hose∙connector∙positioned∙up∙and∙down∙  
2.∙Line∙up∙the∙hose∙connector∙above∙the∙tabs∙on∙the∙exhaust∙outlet.∙∙Slide∙connector∙down∙into∙the∙tabs∙  
locking the connector in place.  
Fig 2.  
part 3: Installing window slider kit  
1. Open the window and place the window slider on the inside edge of the window.  
2. Adjust the window slider to the width of the window.  
3. Insert a screw into the top of the window slider to secure it at the correct length.  
4.∙Take∙window∙slider∙out∙and∙attach∙to∙exhaust∙hose∙by∙snapping∙the∙hose∙adapter∙into∙the∙hole∙on∙the∙window∙slider.∙∙Make∙sure∙that∙the∙tabs∙on∙the∙window∙slider∙are∙facing∙  
outside.  
5.∙Extend∙exhaust∙hose∙to∙desired∙length.  
6. Place window slider and hose into the edge of the window.  
7. Close window to secure slider.  
Fig 3.  
Fig 4.  
7
opeRatIon  
before Use  
•∙Check∙to∙make∙sure∙rubber∙drain∙plugs∙are∙securely∙plugged∙into∙the∙drain∙ports∙on∙the∙back∙of∙the∙unit∙to∙prevent∙water∙leaks  
•∙Check∙to∙make∙sure∙that∙air∙conditioner∙has∙been∙properly∙vented∙out∙the∙window∙(∙See∙Installation∙pg∙7.)  
•∙Check∙to∙make∙sure∙air∙conditioner∙is∙on∙a∙flat∙surface  
•∙Conduct∙a∙Power∙Plug∙Check:  
1. Press the RESET button on the power cord.  
2. Plug cord into an electrical outlet.  
3. Press the TEST button on the power cord. The RESET button should pop up.  
4. Press the RESET button for use.  
5. Do not use the air conditioner if the test fails. The green light on the power cord will turn on if the plug is working properly.  
note: If you turn the air conditioner off and immediately restart it, allow 3 minutes for the compressor to restart cooling.  
In the event of a power failure, wait 3 minutes before restarting unit.  
control panel  
buttons  
Power button  
Timer button  
Sleep mode button  
Mode button  
Fan speed button  
Temperature / Timer up button  
F
C
Temperature / Timer down button  
H
Indicator lights  
Low fan speed  
High fan speed  
Automatic mode  
Dehumidify mode  
Cool mode  
Fan only mode  
8
aRp-9409 / 9411  
control panel operation  
Automatic, Cool, Dehumidify, Fan Only Mode Operation  
1. Turn the unit on  
Press∙the∙Power∙button∙to∙turn∙the∙unit∙on.∙∙The∙red∙light∙next∙to∙the∙power∙button∙and∙the∙Mode,∙Fan∙speed,∙and∙temperature∙indicators∙will∙light∙up.  
2. Select operating mode  
Press the ∙button∙to∙select∙desired∙operating∙mode:  
3. Adjust temperature  
The temperature can be set within a range of 59°F to 87°F by 1 °F intervals.  
Press  
,
to increase or decrease the temperature. The LED display will flash the desired temperature for 5 seconds then display the current room temperature.  
4. Adjust fan speed  
Press the button to select desired fan speed.  
5. Power down  
Press the power button again to turn the unit off.  
Mode descriptions  
automatic mode  
When is selected the unit will automatically select the operation mode with or  
.
When room temperature is greater than 75 °F the unit will automatically select mode.  
When room temperature is less than 75 °F the unit will automatically select mode.  
9
cool mode  
When mode is chosen the air conditioner will run when the room temperature is higher than the set temperature.  
When the room temperature is lower than the set temperature only the fan will run.  
dehumidify mode  
When in mode then fan will run at low speed and cannot be adjusted.  
Temperature cannot be adjusted during dehumidify mode.  
The compressor will stop running after 8 minutes and will turn back on after 6 minutes and will continue to cycle on and off.  
Fan mode  
When is selected the unit will only run the fan at low or high speed.  
Temperature cannot be adjusted during fan mode.  
timer operation  
The timer can be used to turn the unit off after a set amount of time, or to turn the unit on after a set amount of time.  
to use the timer to turn the unit on: While air conditioner is off press the ∙button.∙The∙light∙next∙to∙the∙timer∙button∙will∙blink∙and∙0∙will∙show∙on∙the∙LED∙display.∙∙Press∙the∙  
,
∙buttons∙to∙adjust∙the∙time∙up∙to∙24∙hours.∙∙You∙can∙also∙pre-select∙Mode∙and∙Fan∙speed∙while∙timer∙light∙is∙blinking.∙The∙light∙next∙to∙the∙timer∙will∙stay∙lit∙up∙to∙show∙that∙  
timer is set. The unit will turn on after the set time has passed.  
to use the timer to turn the unit off: Press the ∙button.∙∙The∙light∙next∙to∙the∙timer∙button∙will∙blink∙and∙0∙will∙show∙on∙the∙LED∙display.∙∙Press∙the∙∙  
the time up to 24 hours. The unit will shut down after the set time has passed.  
,
buttons to adjust  
Sleep Mode operation  
Sleep∙mode∙can∙only∙be∙operated∙when∙the∙unit∙is∙in∙Cool∙mode.∙∙When∙in∙Sleep∙mode∙the∙set∙temperature∙will∙1∙°F∙after∙one∙hour∙and∙2∙°F∙after∙two∙hours.∙∙After∙six∙hours∙have∙  
passed the unit will stop running.  
to use sleep mode: Make sure the unit is in Cool mode. Press the ∙button.∙∙The∙light∙next∙to∙the∙sleep∙button∙will∙turn∙on.  
note: The unit has a memory function, when the unit is turned off and back on the previous setting should remain intact. This function does not work when unit is left in Automatic  
mode.  
10  
aRp-9409 / 9411  
Remote control  
To∙use:∙aim∙remote∙control∙at∙the∙sensor∙on∙the∙control∙panel.  
∙∙Power∙button∙:∙Press∙to∙turn∙the∙unit∙on∙or∙off  
∙∙Mode∙button∙:∙Press∙to∙choose∙operation∙mode:∙Automatic,∙Cool,∙Dehumidify,∙Fan  
∙∙Fan∙button∙:∙Press∙to∙choose∙between∙High∙and∙Low∙fan∙speed  
/
∙∙Temperature∙/∙Timer∙button∙:∙Press∙up∙or∙down∙to∙control∙room∙temperature∙or∙timer∙hours  
∙∙Sleep∙mode∙button∙:∙Press∙to∙set∙or∙cancel∙sleep∙mode∙operation  
∙∙Timer∙button∙:∙Press∙to∙set∙unit∙to∙automatically∙turn∙off∙or∙on∙with∙a∙timer  
Remote control battery Installation  
- The remote control uses two AAA batteries which have been included for your convenience.  
- Remove the battery cover on back of the remote.  
-∙Insert∙the∙batteries,∙making∙sure∙the∙(+)∙and∙(-)∙polarity∙is∙aligned∙correctly.  
- Replace the battery cover.  
noteS:  
-When replacing batteries, always change both batteries at the same time.  
-Remove the batteries if the remote control is not used for a month or longer.  
-Do not dispose of batteries in a fire.  
11  
MaIntenance  
drainage  
Occasionally, you may need to drain the unit. The LED display will show E4 when draining is necessary.  
to drain:  
1. Turn off the power to the unit and unplug.  
2. Place the water tray under the drainage port to collect water.  
3. Remove the rubber drainage plug.  
4. Replace the plug, when drainage water stops flowing.  
For continuous drainage into a floor drain:  
1. Turn off the power to the unit and unplug.  
2. Remove the rubber drainage plug from the secondary drainage port.  
3. Attach the drainage hose to the secondary port.  
4. Place other end of drainage hose into a floor drain.  
5. Replace the rubber drainage plug after operation to prevent leaks.  
cleaning the filter  
The filter should be cleaned about every 2 weeks to maintain proper airflow.  
1. Turn off the power to the unit.  
2. Locate the 2 filter knobs on the back of the unit.  
3. Twist both knobs counter clockwise to unlock the filter and remove the knobs.  
4. Remove the filter.  
5. Filter can be cleaned by a vacuum or soft cloth. If the filter is very dirty it can be washed with a mild  
detergent and rinsed with water. Make sure filter is dry before replacement.  
6 . Replace filter and knobs and turn knobs clockwise to the lock position.  
note: Never run the unit without the filter in. The could damage the unit.  
cleaning the unit  
1. Turn off the power to the unit and unplug.  
2. Wipe down unit with a soft, dry, or damp cloth. A mild detergent can be used.  
12  
aRp-9409 / 9411  
3. Never use a volatile substance such a gasoline or abrasive cleaners.  
4. Do not splash water onto the unit.  
Storing the air conditioner  
If the unit will not be used for a long time, be sure to drain the air conditioner, clean the air filter, pull out the power supply plug and wrap around power cord hooks, and remove the  
batteries from the remote control before storage. After draining, keep the air conditioner running on FAN mode for at least 8 hours to dry the unit completely to prevent mold.  
tRoUbleShootInG  
problem  
possible Reasons  
- Check and reset the power plug. Wait 3 minutes and try to run the unit again.  
- The batteries in the remote may need to be replaced. Replace the batteries and try to run the unit again.  
- Make sure the plug is properly plugged into the outlet.  
Air Conditioner does not operate  
- The set temperature may be too close to room temperature. Lower the set temperature.  
- The air outlet may be blocked. Check the air outlet and remove any items that may be found.  
- Check the room for open doors or windows and close them.  
- There may be another appliance in the room giving off heat. Check the room and turn off the appliance.  
- The air filter may be dirty. Check the filter and clean if necessary.  
Air Conditioner runs but does not cool  
-∙The∙air∙exhaust∙or∙intake∙may∙be∙blocked.  
- The set temperature may be too high. Check the set temperature and reduce it if necessary.  
Air Conditioner does not run and LED shows E4  
Water is leaking from the unit  
-∙There∙may∙be∙excess∙water∙in∙the∙unit.∙Drain∙the∙unit.  
- Make sure unit is on a flat surface  
- Drain the unit.  
Machine automatically turns off  
LED display shows E4  
- Timer may have been set to shut off. Turn power back on.  
- Water full. Drain the unit.  
LED display shows E2  
- Temperature sensor error  
LED display shows E3  
- Evaporator error  
13  
SpecIFIcatIonS  
- Figures noted in the contents are for reference only; variation may result due to the application in different countries or regions, and shall be based on practical operation.  
Model  
aRp-9409  
aRp-9411  
Cooling Capacity  
9,000 BTU / 2600W  
1.9 pints / h / .9L/h  
860 W / 7.7 A  
11,000 BTU/ 3200W  
2.3 pints/ h / 1.1 L/h  
1130 W / 10 A  
Dehumidifying Capacity  
Standard Cooling Input Power / Current  
Air∙Flow∙Volume∙  
2
2
340 m /h  
340 m /h  
Voltage∙/∙Frequency  
Sound Pressure Level  
Net Weight  
AC115V∙/∙60∙Hz  
≤∙54dB  
AC115V∙/∙60∙Hz  
≤∙54dB  
53 lbs / 24 kg  
59.5 / 27 kg  
Unit Dimensions  
16.5∙x∙12∙x∙25∙in∙/∙420∙x∙305∙x∙636∙mm  
18.9∙x∙14.6∙x∙32.3∙in∙/∙480∙x∙370∙x∙820∙mm  
R410A  
16.5∙x∙12∙x∙25∙in∙/∙420∙x∙305∙x∙636∙mm  
18.9∙x∙14.6∙x∙32.3∙in∙/∙480∙x∙370∙x∙820∙mm  
R410A  
Packaging Dimensions  
Refrigerant  
“Electrical waste products should not be disposed of with household waste.  
Please∙recycle∙where∙facilities∙exist.∙∙Check∙with∙your∙local∙authority∙or∙retailer∙for∙recycling∙advice."  
14  
aRp-9409 / 9411  
FUll one YeaR waRRantY  
Royal Sovereign warrants each Portable Air Conditioner to be free from defects in material and workmanship. Our obligation under this warranty is limited to the repair or  
replacement,∙free∙of∙charge,∙when∙delivered∙to∙an∙authorized∙Royal∙Sovereign∙service∙center,∙of∙any∙defective∙part(s)∙thereof,∙other∙than∙parts∙damaged∙in∙transit.∙This∙warranty∙is∙  
in effect to the original purchaser, for a period of one year from the date of purchase and is not transferable. This warranty shall apply only if the air conditioner is used on  
Alternating∙Current∙(AC)∙circuit,∙in∙accordance∙with∙the∙factory∙provided∙instructions∙which∙accompany∙it.  
lIMIted FIVe YeaR waRRantY (coMpReSSoR)  
For a period of five years from the date of purchase, when this Royal Sovereign Portable Air Conditioner is operated and maintained according to the instruction manual provided  
with∙the∙product,∙Royal∙Sovereign∙will∙supply∙a∙replacement∙compressor∙(parts∙only),∙free∙ofcharge,∙if∙the∙original∙compressor∙is∙determined∙to∙be∙defective∙in∙workmanship∙or∙  
material. If repair becomes necessary, please contact our customer service center. You will be responsible for all freight, insurance, and any other transportation charges to get the  
unit to our factory or service center. If shipping is required, be sure to pack the unit properly to avoid shipping damages, as we will not be responsible for such damages.  
eXclUSIonS  
This∙warranty∙excludes∙and∙does∙not∙cover∙defects,∙malfunctions∙or∙failures∙ofyour∙Royal∙Sovereign∙Portable∙Air∙Conditioner,∙caused∙by∙repairs∙by∙unauthorized∙persons∙or∙service∙  
centers, mishandling, improper installation, modification or unreasonable use including incorrect voltage, acts of God, or failure to provide reasonable and necessary maintenance.  
This∙warranty∙is∙in∙lieu∙of∙any∙and∙all∙expressed∙warranties.∙In∙no∙event∙shall∙Royal∙Sovereign∙be∙liable∙for∙consequential∙or∙incidental∙damages.∙This∙limitation∙would∙not∙apply∙if∙you∙  
live∙in∙a∙∙location∙thas∙does∙not∙permit∙the∙exclusion∙of∙limitation∙of∙incidental∙or∙consequential∙damages.∙This∙warranty∙gives∙you∙specific∙legal∙rights∙and∙you∙may∙also∙have∙other∙  
rights which vary from state to state.  
15  
RoYal SoVeReIGn InteRnatIonal, Inc.  
2∙Volvo∙Drive∙Rockleigh,∙NJ∙07647∙USA  
TEL∙:∙+1)∙800-397-1025∙∙∙∙∙∙∙∙FAX∙:∙+1)∙201-750-1022  
RS InteRnatIonal aUStRalIa ptY. ltd.  
30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA  
RS holland b.V.  
Industrieweg 6K, 4104AR, Culemborg, The Netherlands  
Tel:∙+31∙(0)345∙473∙097∙∙∙∙Fax:∙31∙(0)345∙519∙811  
TEL∙∙:∙+61)∙2-9674-2127∙  
FAX∙∙:∙+61)∙2-9674-2027  
RoYal SoVeReIGn Inc.  
RS canada Inc.  
1001, World Meridian II, 426-5, Gasan-dong, Geumcheon-gu, Seoul, 153-759, KOREA 1025 Westport Crescent, Mississauga On L5T 1E8 CANADA  
TEL∙∙:∙+82)2-2025-8800∙∙∙∙∙∙FAX∙∙:∙+82)2-2025-8830  
TEL∙:∙+1)∙905-461-1095∙∙∙∙∙∙∙∙∙∙∙∙∙∙TF:∙+1)∙866∙961-6673∙∙∙  
Fax∙:∙+1)∙905-461-1096  
SpanISh  
ManUal del USUaRIo  
aRp-9409, aRp-9411  
aRp-9409 / aRp-9411  
poRtÁtIl de aIRe acondIcIonado  
Lea y conserve estas instrucciones para referencia futura.  
para cualquier asistencia al cliente las necesidades,  
por favor, seleccione la pestaña de soporte en www.royalsovereign.com  
Royal Sovereign International, Inc  
poRtÁtIl de aIRe acondIcIonado  
ARP-9409, ARP-9411  
IntRodUccn  
Gracias∙por∙elegir∙Royal∙Sovereign∙para∙brindarle∙a∙usted∙ya∙su∙familia∙con∙todas∙las∙de∙la∙"Casa∙Confort"∙los∙requisitos∙para∙su∙casa,∙  
apartamento u oficina. Este acondicionador de aire portátil puede ser puesta en marcha en cuestión de minutos y se pueden mover fácilmente  
de una habitación a otra. Es un aire multi-funcional sala de sistema de confort que le ofrece aire acondicionado, deshumidificación y los modos  
de circulación de aire. Este manual le proporcionará valiosa información necesaria para el cuidado y mantenimiento para su nuevo aparato. Por  
favor, tómese unos minutos y lea las instrucciones cuidadosamente. Si el mantenimiento adecuado, el aparato le dará muchos años de operación  
libre de problemas.  
ÍndIce  
Page  
Precauciones para el uso ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 20  
Identificación de las partes∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21  
Las instrucciones de instalación ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22~23  
Operación ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 24~27  
Mantenimiento ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 28  
Solución de problemas ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 29  
Especificaciones ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 30  
Garantía∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 31  
Información de contacto∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 32  
pRecaUcIoneS paRa el USo  
especificaciones eléctricas y cable de alimentación  
Compruebe∙que∙el∙servicio∙eléctrico∙que∙se∙utiliza∙es∙adecuado∙para∙el∙modelo∙que∙ha∙elegido.∙La∙potencia∙eléctrica∙de∙su∙acondicionador∙de∙aire∙  
nuevo∙se∙define∙en∙la∙placa∙de∙serie∙de∙la∙unidad.∙Por∙favor∙refiérase∙a∙la∙calificación∙al∙comprobar∙los∙requisitos∙eléctricos∙para∙garantizar∙que∙  
cumplen los códigos eléctricos de su ubicación.  
•∙Instale∙el∙acondicionador∙de∙aire∙de∙acuerdo∙con∙las∙instrucciones∙de∙instalación∙suministrado.∙  
•∙No∙modifique∙ninguna∙parte∙de∙este∙producto.∙  
•∙No∙introduzca∙ningún∙objeto∙en∙el∙producto∙o∙bloquear∙el∙flujo∙de∙aire∙de∙ninguna∙manera.∙  
•∙Asegúrese∙de∙que∙la∙fuente∙de∙alimentación∙que∙utiliza∙tiene∙un∙voltaje∙adecuado.∙  
•∙Utilice∙sólo∙un∙equipo∙instalado∙de∙3∙pines,∙conector∙a∙tierra∙de∙CA∙que∙está∙clasificado∙115V,∙60Hz,∙15∙amperios∙o∙más.∙  
•∙Si∙la∙toma∙de∙corriente∙que∙vaya∙a∙utilizar∙no∙está∙adecuadamente∙conectada∙a∙tierra∙o∙protegido∙por∙un∙fusible∙de∙retardo∙o∙un∙interruptor∙de∙  
circuito, usted debe tener un electricista calificado instale un tomacorriente adecuado.  
•∙Esta∙unidad∙utiliza∙un∙enchufe∙con∙un∙fusible∙incorporado.∙Llevar∙a∙cabo∙un∙enchufe∙de∙retención∙(ver∙página∙25)∙antes∙de∙su∙uso∙para∙confirmar∙la∙operación∙normal.∙  
• No utilice esta unidad con todos los cables de extensión o adaptador de enchufe.  
•∙Si∙el∙cable∙o∙el∙enchufe∙está∙dañado∙de∙alguna∙manera,∙por∙favor∙llame∙al∙Departamento∙de∙Servicio∙Royal∙Sovereign∙(ver∙página∙32.)  
•∙No∙conecte∙este∙cable∙a∙una∙toma∙de∙corriente∙floja.∙  
•∙Al∙limpiar∙el∙acondicionador∙de∙aire,∙retire∙el∙filtro,∙o∙cuando∙el∙acondicionador∙de∙aire∙no∙se∙utiliza∙durante∙un∙período∙de∙tiempo∙prolongado,∙apague∙la∙unidad∙y∙desenchufe.∙  
Uso General  
•∙No∙obstruya∙las∙salidas∙de∙aire∙o∙la∙ingesta∙de∙obstáculos.∙  
•∙No∙introduzca∙ningún∙objeto∙en∙el∙aire∙acondicionado.∙  
•∙No∙rocíe∙o∙vierta∙agua∙en∙el∙panel∙de∙la∙vivienda∙o∙el∙control.∙  
•∙No∙coloque∙objetos∙pesados∙o∙sentarse∙en∙la∙unidad.∙  
•∙Asegúrese∙de∙que∙el∙tapón∙de∙drenaje∙está∙instalado∙en∙la∙parte∙inferior∙de∙la∙máquina.∙  
•∙drenaje∙de∙la∙unidad∙cuando∙se∙mueve∙el∙aire∙acondicionado∙o∙al∙guardar∙la∙unidad.∙  
20  
aRp-9409 / 9411  
IdentIFIcacn de laS paRteS  
1. Panel de control  
2. Salida de aire  
3. Mando a distancia  
4. Manejar  
5. Tubo de escape  
6. Toma de aire  
7. Salida de escape  
8. Filtro  
9. Drenaje del puerto  
10. Cable de alimentación  
11. Cable de alimentación ganchos  
12. Orificio de drenaje secundario  
13. Rueda del echador  
21  
InStalacn  
Desempaque su nuevo acondicionador de aire portátil y dejar la máquina en posición vertical durante  
2∙horas∙antes∙de∙comenzar.∙  
Desembale∙todas∙las∙piezas∙del∙kit∙de∙instalación∙de∙la∙ventana∙antes∙mencionados.∙Si∙falta∙alguna∙pie
y∙haga∙clic∙en∙"Ayuda"∙ficha.∙  
accessories Include  
1. Tubo de escape  
2. Conector de la manguera  
3. Adaptador de manguera  
4. Mando a distancia  
5. Bandeja para el agua  
6. Manguera de drenaje  
7.∙Ventana∙deslizante∙  
6. Manguera de drenaje  
7.∙Ventana∙deslizante  
parte 1: la manguera de escape, conector y adaptador  
1.∙Extender∙un∙extremo∙de∙la∙manguera∙de∙escape.∙  
2.∙Tome∙el∙conector∙de∙la∙manguera∙y∙gire∙hacia∙la∙izquierda∙en∙un∙extremo∙de∙la∙manguera∙de∙e
3.∙Extienda∙el∙extremo∙opuesto∙de∙la∙manguera∙de∙escape.∙  
4.∙Tome∙el∙adaptador∙de∙la∙manguera∙y∙el∙giro∙hacia∙la∙izquierda∙en∙el∙extremo∙no∙utilizado∙de∙la
de escape.  
Fig 1.  
22  
aRp-9409 / 9411  
parte 2: colocación de tubo de escape  
1. Sostenga el tubo de escape paralelo al piso con el conector de la manguera colocada arriba y abajo  
2. Alinee el conector de la manguera por encima de las pestañas en la salida de escape.  
Deslice el conector hacia abajo en las lengüetas de fijación del conector en su lugar.  
Fig 2.  
parte 3: Instalación de ventana deslizante kit  
1.∙Abra∙la∙ventana∙y∙coloque∙el∙control∙deslizante∙de∙la∙ventana∙en∙el∙borde∙interior∙de∙la∙ventana.∙  
2.∙Ajuste∙el∙deslizador∙de∙ventana∙a∙la∙anchura∙de∙la∙ventana.∙  
3. Inserte un tornillo en la parte superior de la corredera ventana para asegurarlo en la longitud correcta.  
4.∙Tome∙control∙deslizante∙de∙la∙ventana∙y∙se∙adhieren∙al∙tubo∙de∙escape∙por∙romperse∙el∙adaptador∙de∙la∙manguera∙en∙el∙orificio∙de∙la∙ventana∙deslizante.∙  
Asegúrese∙de∙que∙las∙pestañas∙de∙la∙ventana∙deslizante∙se∙enfrentan∙afuera.∙  
5.∙Extienda∙la∙manguera∙de∙escape∙a∙la∙longitud∙deseada.∙  
6. Lugar regulador y la manguera de la ventana en el borde de la ventana.  
7.∙Cerrar∙la∙ventana∙para∙asegurar∙control∙deslizante.∙  
Fig 3.  
Fig 4.  
23  
opeRacn  
antes del uso  
•∙Asegúrese∙de∙que∙los∙tapones∙de∙drenaje∙de∙goma∙estén∙bien∙conectados∙a∙los∙puertos∙de∙drenaje∙en∙la∙parte∙posterior∙de∙la∙unidad∙para∙evitar∙fugas∙de∙agua∙  
•∙Asegúrese∙de∙que∙el∙acondicionador∙de∙aire∙ha∙sido∙una∙ventilación∙adecuada∙por∙la∙ventana∙(ver∙página∙23∙de∙instalación.)∙  
•∙Verifique∙que∙el∙aire∙acondicionado∙esté∙en∙una∙superficie∙plana∙  
•∙Llevar∙a∙cabo∙una∙verificación∙de∙Plug∙Power:∙  
1. Pulse el botón RESET en el cable de alimentación.  
2. Conecte el cable a una toma de corriente.  
3. Pulse el botón TEST en el cable de alimentación. El botón RESET debe saltar.  
4. Pulse el botón RESET para su uso.  
5.∙No∙utilice∙el∙acondicionador∙de∙aire∙si∙la∙prueba∙falla.∙La∙luz∙verde∙en∙el∙cable∙de∙alimentación∙se∙enciende∙si∙el∙enchufe∙funciona∙correctamente.∙  
nota: Si usted apaga el acondicionador de aire y de inmediato lo reinicie, espere 3 minutos para que el compresor reanude el enfriamiento. En el caso de un fallo de alimentación,  
espere 3 minutos antes de reiniciar la unidad.  
panel de control  
botones  
Botón de encendido  
Botón de modo de sueño  
Botón de modo  
∙∙El∙botón∙del∙temporizador∙  
Botón de la velocidad del ventilador  
F
C
∙∙Temperatura∙/∙Temporizador∙hasta∙el∙botón∙  
H
∙∙Temperatura∙/∙Temporizador∙pulsado∙el∙botón∙  
luces indicadoras  
Baja la velocidad del ventilador  
Modo automático  
Alta velocidad del ventilador  
Modo de refrigeración  
El modo de deshumidificación  
∙∙Ventilador∙sólo∙en∙modo∙  
24  
aRp-9409 / 9411  
operación del control panel  
Automática, fresco, deshumidificación, la Operación de los admiradores Sólo en el modo  
1. Encienda la unidad  
Pulse∙el∙botón∙de∙encendido∙para∙encender∙la∙unidad.∙La∙luz∙roja∙al∙lado∙del∙botón∙de∙encendido∙y∙el∙modo,∙la∙velocidad∙del∙ventilador,∙y∙los∙indicadores∙de∙temperatura∙se∙  
encenderá.  
2. Seleccione el modo de funcionamiento  
Pulse el botón ∙el∙botón∙para∙seleccionar∙el∙modo∙de∙funcionamiento:∙  
3. Ajuste la temperatura  
La temperatura se puede ajustar dentro de un rango de 59 °F a 87 °F por intervalos de 1 °F.  
Pulse  
,
para aumentar o disminuir la temperatura. La pantalla LED mostrará la temperatura deseada durante 5 segundos y luego mostrar la temperatura ambiente  
actual.  
4. Ajuste la velocidad del ventilador  
Presione el botón para seleccionar la velocidad deseada del ventilador.  
5. Apague  
Pulse∙el∙botón∙otra∙vez∙para∙apagar∙la∙unidad.∙  
Modo descripciones  
Modo automático  
Cuando se selecciona la unidad seleccionará automáticamente el modo de operación con  
o
.
Cuando la temperatura ambiente es superior a 75 °F la unidad seleccionará automáticamente de modo.  
Cuando la temperatura ambiente sea inferior al 75 °F de la unidad seleccionará automáticamente de modo.  
25  
Modo de refrigeración  
Cuando se elige el modo de aire acondicionado se ejecutará cuando la temperatura ambiente es superior a la temperatura programada.  
Cuando la temperatura ambiente es inferior a la temperatura programada sólo el ventilador funcionará.  
el modo de deshumidificación  
En caso de el modo de continuación, ventilador funciona a baja velocidad y no se pueden ajustar.  
La temperatura no puede ajustarse durante el modo de deshumidificación.  
El compresor deja de funcionar después de 8 minutos y se volverá a encender al cabo de 6 minutos y seguirá ciclo de encendido y apagado.  
Ventilador de modo  
Cuando se selecciona la unidad sólo se ejecutará el ventilador a velocidad baja o alta.  
La temperatura no puede ajustarse durante el modo de ventilador.  
Funcionamiento del temporizador  
El∙temporizador∙se∙puede∙utilizar∙para∙apagar∙la∙unidad∙después∙de∙un∙periodo∙de∙tiempo,∙o∙para∙encender∙la∙unidad∙después∙de∙un∙periodo∙de∙tiempo.∙  
Para∙utilizar∙el∙temporizador∙para∙encender∙la∙unidad:∙Si∙bien∙el∙aire∙acondicionado∙está∙apagado,∙pulse∙el∙botón∙ ∙.∙La∙luz∙al∙lado∙del∙botón∙del∙temporizador∙parpadeará∙y∙0∙se∙  
mostrará en la pantalla LED. Presione el botón  
,
para ajustar el tiempo hasta 24 horas. También puede pre-seleccionar el modo y la velocidad del ventilador mientras que la  
luz∙del∙temporizador∙parpadea.∙La∙luz∙al∙lado∙del∙temporizador∙permanece∙encendido∙para∙indicar∙que∙el∙temporizador∙está∙programado.∙La∙unidad∙se∙enciende∙después∙de∙la∙  
hora fijada ya ha pasado.  
Para∙utilizar∙el∙temporizador∙para∙apagar∙la∙unidad:∙Presione∙el∙botón∙ ∙.∙La∙luz∙al∙lado∙del∙botón∙del∙temporizador∙parpadeará∙y∙0∙se∙mostrará∙en∙la∙pantalla∙LED.∙Presione∙el∙  
botón  
,
para ajustar el tiempo hasta 24 horas. La unidad se apagará después de la hora fijada ya ha pasado.  
el sueño del modo de funcionamiento  
Modo de suspensión sólo puede funcionar cuando la unidad está en modo frío. Cuando está en modo de reposo la temperatura programada una F después de una hora y 2 °F  
después de dos horas. Después de seis horas han pasado la unidad dejará de funcionar.  
Para∙utilizar∙el∙modo∙de∙suspensión:∙Asegúrese∙de∙que∙la∙unidad∙está∙en∙modo∙frío.∙Pulse∙el∙botón∙ ∙.∙La∙luz∙al∙lado∙del∙botón∙de∙reposo∙se∙enciende.∙  
nota: La unidad tiene una función de memoria, cuando la unidad esté apagada y volver a la configuración anterior debe permanecer intacto. Esta función no funciona cuando la  
unidad se deja en el modo automático.  
26  
aRp-9409 / 9411  
control Remoto  
Modo∙de∙empleo:∙el∙control∙objetivo∙de∙distancia∙hacia∙el∙sensor∙en∙el∙panel∙de∙control.∙∙  
∙∙Botón∙de∙encendido∙:∙Pulse∙para∙encender∙la∙unidad∙o∙fuera∙de∙  
∙∙Botón∙de∙modo∙:∙Pulse∙para∙seleccionar∙el∙modo∙de∙funcionamiento:∙automático,∙fresco,∙deshumidificación,∙Ventilador∙  
∙∙Botón∙de∙ventilador∙:∙Pulse∙para∙elegir∙entre∙alta∙y∙baja∙velocidad∙del∙ventilador∙  
/
∙∙Temperatura∙/∙el∙botón∙del∙temporizador∙:∙  
Presione∙hacia∙arriba∙o∙hacia∙abajo∙para∙el∙control∙de∙horas∙la∙temperatura∙ambiente∙o∙el∙temporizador∙  
∙∙Botón∙de∙modo∙de∙sueño∙:∙Pulse∙para∙ajustar∙o∙cancelar∙la∙operación∙en∙modo∙del∙sueño∙  
∙∙El∙botón∙del∙temporizador∙:∙Pulse∙para∙configurar∙la∙unidad∙para∙apagar∙automáticamente∙o∙con∙un∙temporizador∙  
Mando a distancia Instalación de las pilas  
-∙El∙control∙remoto∙utiliza∙dos∙baterías∙AAA∙que∙se∙han∙incluido∙para∙su∙conveniencia.∙  
- Retire la tapa de la batería en la parte posterior del mando a distancia.  
-∙Coloque∙las∙pilas,∙asegurándose∙de∙que∙el∙(+)∙y∙(-)∙polaridad∙está∙alineado∙correctamente.∙  
-∙Vuelva∙a∙colocar∙la∙tapa∙de∙la∙batería.∙  
notaS:  
-Al cambiar las pilas, siempre cambie ambas baterías al mismo tiempo.  
-Quite∙las∙pilas∙si∙el∙control∙remoto∙no∙se∙utiliza∙durante∙un∙mes∙o∙más.∙  
-No arroje las baterías al fuego.  
27  
MantenIMIento  
drenaje  
para drenar:  
1. Apague la alimentación de la unidad y desenchufe.  
2. Coloque la bandeja de agua en el puerto de drenaje para recoger el agua.  
3. Retire el tapón de drenaje de goma.  
4.∙Vuelva∙a∙colocar∙el∙tapón,∙cuando∙el∙agua∙deja∙de∙fluir∙de∙drenaje.∙  
para el drenaje continuo en un desagüe de piso:  
1. Apague la alimentación de la unidad y desenchufe.  
2.∙Retire∙el∙tapón∙de∙drenaje∙de∙goma∙de∙la∙conexión∙de∙drenaje∙secundario.∙  
3. Conecte la manguera de drenaje para el puerto secundario.  
4.∙Coloque∙el∙otro∙extremo∙de∙la∙manguera∙de∙drenaje∙en∙un∙desagüe∙de∙piso.∙  
5.∙Vuelva∙a∙colocar∙el∙tapón∙de∙drenaje∙de∙goma∙después∙de∙la∙operación∙para∙evitar∙fugas.∙  
limpieza del filtro  
El filtro debe ser limpiado cada 2 semanas para mantener el flujo de aire apropiado.  
1. Apague la alimentación de la unidad.  
2. Localice los 2 botones de filtro en la parte posterior de la unidad.  
3. Gire ambas perillas en sentido antihorario para desbloquear el filtro y quitar las perillas.  
4. Quite el filtro.  
5. Filtro puede ser limpiado por un vacío o un paño suave. Si el filtro está muy sucio se puede lavar con un  
detergente∙suave∙y∙enjuagar∙con∙agua.∙Asegúrese∙de∙que∙el∙filtro∙esté∙seco∙antes∙de∙la∙sustitución.∙  
6. Reemplace el filtro y las perillas y botones a la derecha para la posición de bloqueo.  
nota: Nunca haga funcionar la unidad sin el filtro in El podría dañar la unidad.  
limpieza de la unidad  
1. Apague la alimentación de la unidad y desenchufe.  
2.∙Limpie∙la∙unidad∙con∙un∙paño∙suave∙y∙seco∙o∙húmedo.∙Un∙detergente∙puede∙ser∙utilizado.∙  
28  
aRp-9409 / 9411  
3.∙Nunca∙use∙una∙sustancia∙volátil∙como∙la∙gasolina∙o∙productos∙de∙limpieza∙abrasivos.∙  
4. No salpique agua sobre la unidad.  
almacenar el acondicionador de aire  
Si∙la∙unidad∙no∙será∙utilizada∙durante∙mucho∙tiempo,∙asegúrese∙de∙drenar∙el∙acondicionador∙de∙aire,∙limpiar∙el∙filtro∙de∙aire,∙saque∙el∙enchufe∙de∙alimentación∙y∙envolver∙cable∙de∙  
alimentación de los ganchos, y retire las pilas del mando a distancia antes de su almacenamiento. Después de drenar, mantener el aire acondicionado funcionando en modo FAN  
durante al menos 8 horas para secar completamente la unidad para evitar el moho.  
SolUcn de pRobleMaS  
problema  
posible Solución  
-∙Verificar∙y∙restablecer∙el∙cable∙de∙alimentación.∙Espere∙3∙minutos∙e∙intente∙ejecutar∙de∙nuevo∙la∙unidad.∙  
-∙Las∙pilas∙del∙mando∙a∙distancia∙puede∙necesitar∙ser∙reemplazada.∙Cambie∙las∙pilas∙e∙intente∙ejecutar∙de∙nuevo∙la∙unidad.∙  
-∙Asegúrese∙que∙el∙enchufe∙esté∙bien∙conectado∙en∙el∙tomacorriente.∙  
Aire acondicionado no funciona  
- La temperatura puede estar demasiado cerca de la temperatura ambiente. Baje la temperatura del sistema.  
- La salida de aire puede estar bloqueada. Compruebe la salida de aire y quite todos los elementos que se pueden encontrar.  
- Controlar el espacio para puertas o ventanas abiertas y cerrarlas.  
- Es posible que haya otro aparato en la sala de un desprendimiento de calor. Compruebe la habitación y apagar el aparato.  
- El filtro de aire puede estar sucio. Revise el filtro y límpielo si es necesario.  
Acondicionador de aire funciona pero no enfría  
- El aire de escape o la ingesta puede ser bloqueada.  
- La temperatura puede ser muy alto. Compruebe la temperatura del sistema y reducir, si es necesario.  
Aire acondicionado no funciona y el LED muestra  
E4  
-∙Puede∙haber∙exceso∙de∙agua∙en∙la∙unidad.∙Drenaje∙de∙la∙unidad.∙  
-∙Asegúrese∙que∙la∙unidad∙esté∙en∙una∙superficie∙plana∙  
- Drenaje de la unidad.  
Hay fugas de agua de la unidad  
La máquina se apaga automáticamente  
Pantalla LED muestra E4  
-∙Contador∙de∙tiempo∙puede∙haber∙sido∙programado∙para∙apagar∙el.∙Vuelva∙a∙encender.∙  
- El agua lleno. Drenaje de la unidad.  
Pantalla LED muestra E2  
- Error en el sensor de temperatura  
Pantalla LED muestra E3  
- Error del evaporador  
29  
eSpecIFIcacIoneS  
- Las medidas que aparecen son solo para referencia, pueden haber variaciones debido a las diferencias entre países y regiones, y deben ser basadas en funcionamiento práctico.  
Modelo  
Capacidad de enfriamiento  
aRp-9409  
aRp-9411  
9,000 BTU / 2600W  
1.9 pints / h / .9L/h  
860 W / 7.7 A  
11,000 BTU/ 3200W  
2.3 pints/ h / 1.1 L/h  
1130 W / 10 A  
Capacidad de deshumidificación  
Estándar de entrada de energía de refrigeración / actual  
De volumen de aire de flujo  
Tensión / frecuencia  
2
2
340 m /h  
340 m /h  
AC115V∙/∙60∙Hz  
≤∙54dB  
AC115V∙/∙60∙Hz  
≤∙54dB  
Nivel de presión sonora  
Peso neto  
53 lbs / 24 kg  
59.5 / 27 kg  
Unidad Dimensiones  
16.5∙x∙12∙x∙25∙in∙/∙420∙x∙305∙x∙636∙mm  
18.9∙x∙14.6∙x∙32.3∙in∙/∙480∙x∙370∙x∙820∙mm  
R410A  
16.5∙x∙12∙x∙25∙in∙/∙420∙x∙305∙x∙636∙mm  
18.9∙x∙14.6∙x∙32.3∙in∙/∙480∙x∙370∙x∙820∙mm  
R410A  
Embalaje Dimensiones  
Refrigerante  
“Los desperdicios eléctricos no deben botarse juntamente con la basura doméstica.  
Por favor, recicle cuando sea posible. Contacte a las autoridades locales por consejos referentes al  
reciclaje.”  
30  
aRp-9409 / 9411  
GaRantÍa coMpleta poR Un aÑo  
Royal∙Sovereign∙garantiza∙que∙cada∙Acondicionador∙de∙Aire∙Portátil∙está∙libre∙de∙defectos∙en∙cuanto∙a∙materiales∙y∙fabricación.∙Nuestra∙obligación∙bajo∙esta∙garantía∙está∙limitada∙  
a∙la∙reparación∙o∙sustitución,∙sin∙costo,∙de∙cualquier∙parte(s)∙defectuosa(s)∙que∙no∙se∙haya∙dañado∙en∙el∙transporte,∙cuando∙el∙producto∙sea∙entregado∙a∙un∙Centro∙de∙Servicio∙de∙  
Royal Sovereign. Esta garantía cubre al comprador original por un desde la fecha de compra y no es transferible. Esta garantía se aplica solo si el acondicionador de aire se usa en  
un circuito de Corriente Alterna, de acuerdo a las instrucciones de fábrica que acompañan al producto.  
GaRantÍa lIMItada poR cInco aÑoS (coMpReSoR)  
Por un periodo de cinco años desde la fecha de compra, siempre y cuando este Acondicionador de Aire Portátil Royal Sovereign sea operado y mantenido de acuerdo al manual de  
instrucciones∙provisto∙con∙el∙producto,∙Royal∙Sovereign∙suplirá∙un∙compresor∙de∙reemplazo∙(solamente∙la∙parte),∙sin∙costo,∙si∙se∙determina∙que∙el∙compresor∙original∙tiene∙una∙  
falla en cuanto a mano de obra o materiales. Si es necesaria la reparación, por favor contacte a nuestro centro de servicio al cliente. Usted será responsable por el envío, seguro y  
cualquier∙otro∙gasto∙de∙transporte∙para∙hacer∙llegar∙la∙unidad∙a∙nuestra∙fabrica∙o∙centro∙de∙servicio.∙Si∙es∙necesario∙el∙envío,∙asegúrese∙de∙empacar∙∙la∙unidad∙correctamente∙para∙  
evitar daños en el transporte, pues nosotros no seremos responsables por aquellos daños.  
eXclUSIoneS  
Esta∙garantía∙excluye∙y∙no∙cubre∙defectos,∙malfuncionamiento∙o∙fallas∙de∙su∙Acondicionador∙de∙Aire∙Portátil∙Royal∙Sovereign∙causadas∙por∙reparaciones∙hechas∙por∙personas∙o∙  
centros∙de∙servicio∙desautorizados,∙manejo∙inadecuado,∙instalación∙inapropiada,∙modificación∙o∙uso∙irrazonable∙de∙voltaje∙incorrecto,∙fuerzas∙de∙la∙naturaleza,∙o∙dejar∙de∙hacer∙el∙  
mantenimiento∙razonable∙y∙necesario.∙Esta∙garantía∙es∙en∙lugar∙de∙todas∙y∙cada∙una∙de∙las∙garantías∙expresas.∙En∙ninguna∙eventualidad∙Royal∙Sovereign∙será∙responsable∙por∙  
daños incidentales o consecuentes. Esta limitación no se aplica si usted vive en un lugar en donde no es permitida la limitación de daños incidentales o consecuentes. Esta garantía  
le da derechos legales específicos y usted puede tener otros derechos los cuales varían de estado a estado.  
31  
RoYal SoVeReIGn InteRnatIonal, Inc.  
2∙Volvo∙Drive∙Rockleigh,∙NJ∙07647∙USA  
TEL∙:∙+1)∙800-397-1025∙∙∙∙∙∙∙∙FAX∙:∙+1)∙201-750-1022  
RS InteRnatIonal aUStRalIa ptY. ltd.  
30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA  
RS holland b.V.  
Industrieweg 6K, 4104AR, Culemborg, The Netherlands  
Tel:∙+31∙(0)345∙473∙097∙∙∙∙Fax:∙31∙(0)345∙519∙811  
TEL∙∙:∙+61)∙2-9674-2127∙  
FAX∙∙:∙+61)∙2-9674-2027  
RoYal SoVeReIGn Inc.  
RS canada Inc.  
1001, World Meridian II, 426-5, Gasan-dong, Geumcheon-gu, Seoul, 153-759, KOREA 1025 Westport Crescent, Mississauga On L5T 1E8 CANADA  
TEL∙∙:∙+82)2-2025-8800∙∙∙∙∙∙FAX∙∙:∙+82)2-2025-8830  
TEL∙:∙+1)∙905-461-1095∙∙∙∙∙∙∙∙∙∙∙∙∙∙TF:∙+1)∙866∙961-6673∙∙∙  
Fax∙:∙+1)∙905-461-1096  

Philips Tv Screen 37pfl3403 User Manual
Roberts Gorden Combat At 148 User Manual
Samsung Mh07zv 26 User Manual
Sanyo N 2000ck User Manual
Sharper Image Quadra Si637 User Manual
Soleus Air Sptac 15h User Manual
Toshiba Air Conditioner Rav Sm564bt E User Manual
Whirlpool Acm072 User Manual
York Air Conditioner 66386 Yum C 1011 User Manual
York Sunline Magnum Dj 210 User Manual