| ® Combat AT-Series   Indirect-Fired Air Turnover Units   Dimension and   Selection Guide   1.800.828.7450   ™ Quality in Any Language   AT-Series Heating Unit with Filtration   K DA   DA   DA   DA   H J F F LIFTING   ANGLES   CONTROL   PANEL   D INSPECTION   AND RELIEF   PORT   E SPLIT   FOR   SHIPMENT   C G RA   RA   RA   RA   L N L M B M A FRONT VIEW   END VIEW   DIMENSIONS   LEGEND   AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272   DA = Discharge Air   A B C 60   50   75   72   60   75   85   72   86   90   50   60   100   55   66   116   60   66   145   72   72   160   84   72   165   90   76   RA = Return Air   75 - 53   75 - 53 100 - 53   100 - 53 125 - 72   125 - 72 150 - 72   175 - 72   D 53   53   65   53   90   96   96   IMPORTANT NOTES:   • All dimensions are subject to change   without notice.   • Due to height of unit, additional support is   recommended on top of the unit.   • Dimension "F" is flue diameter. Flue located   on left side of unit for 1,000 MBH heat   exchanger and smaller; flue located on right   side of unit for 1,250 MBH heat exchanger   and larger.   • Dimensions "D" and "F" may vary depending   on heat exchanger size (ex. 45 = 450 MBH   heat exchanger).   • All dimensions are in inches.   E F 35   35   35   35   35   35   35   35   35   45 - 6   75 - 6   45 - 6   75 - 6   45 - 6   75 - 6   45 - 6   75 - 6   75 - 6 175 - 12 300 - 14 300 - 14   70 - 6 100 - 8 100 - 8 225 - 12 450 - 16 450 - 16   100 - 8 100 - 8 100 - 8 100 - 8 125 - 10 125 - 10 300 - 14   125 - 10   175 - 12   G H J K L 3 24   48   .75   .75   6 3 24   48   .75   .75   6 3 3 24   48   .75   .75   6 3 30   48   .75   .75   6 3 4 36   48   .75   .75   6 4 36   48   .75   .75   6 4 40   48   .75   .75   6 36   48   .75   .75   6 30   48   .75   .75   6 M N 3 3 3 3 3 3 3 3 3 3 AT-Series Cooling Unit with Filtration   H DA   DA   DA   DA   F D LIFTING   ANGLES   M SPLIT   FOR   G SHIPMENT   C RA   RA   RA   RA   L E J J K A K B FRONT VIEW   END VIEW   DIMENSIONS   LEGEND   AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272   DA = Discharge Air   A B C D E F G H J 60   50   75   48   6 72   60   85   48   6 85   72   95   48   6 90   50   85   48   6 100   55   85   48   6 116   60   95   48   6 145   72   90   48   6 160   84   90   48   6 165   90   90   48   6 RA = Return Air   24   24   36   10   .75   .75   6 24   10   .75   .75   6 30   16   .75   .75   6 30   6 .75   .75   6 36   36   40   10   .75   .75   6 IMPORTANT NOTES:   • All dimensions are in inches.   • All dimensions are subject to change   without notice.   .75   .75   6 .75   .75   6 .75   .75   6 .75   .75   6 K L M • Due to height of unit, additional support is   recommended on top of the unit.   3 3 3 3 3 3 3 3 3 N/A   N/A   N/A   N/A   N/A   N/A   50   50   50   4 AT-Series Heating and Cooling Unit with Filtration   K DA   DA   DA   H DA   E LIFTING   ANGLES   F F CONTROL   PANEL   D P INSPECTION   AND   RELIEF PORT   Q SPLIT   LIFTING   ANGLES   FOR   J SHIPMENT   C G RA   RA   RA   RA   L N L A B M M FRONT VIEW   END VIEW   DIMENSIONS   LEGEND   AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272   DA = Discharge Air   A B C 60   50   75   72   60   85   85   72   95   90   50   85   100   55   85   116   60   95   145   72   90   160   84   90   165   90   90   RA = Return Air   75 - 53   75 - 53 100 - 53   100 - 53 125 - 72   125 - 72 150 - 72   175 - 72   D 53   53   65   53   90   48   96   48   96   48   IMPORTANT NOTES:   • All dimensions are subject to change   without notice.   • Due to height of unit, additional support   is recommended on top of the unit.   • Dimension "F" is flue diameter. Flue   located on left side of unit for 1,000 MBH   heat exchanger and smaller; flue located   on right side of unit for 1,250 MBH heat   exchanger and larger.   • Dimensions "D" and "F" may vary   depending on heat exchanger size   (ex. 45 = 450 MBH heat exchanger).   • All dimensions are in inches.   E F 48   45 - 6   75 - 6   48   45 - 6   75 - 6   48   45 - 6   75 - 6   48   45 - 6   48   48   75 - 6   75 - 6 175 - 12 300 - 14 300 - 14   75 - 6 100 - 8 100 - 8 225 - 12 450 - 16 450 - 16   100 - 8 100 - 8 100 - 8 100 - 8 125 - 10 125 - 10 300 - 14   125 - 10   175 - 12   G H J K L M N P Q 6 24   6 24   6 36   10   .75   .75   6 3 N/A   35   6 24   10   .75   .75   6 3 N/A   35   6 30   16   .75   .75   6 6 30   6 .75   .75   6 6 36   6 36   6 40   10   .75   .75   6 3 50   35   .75   .75   6 3 N/A   35   .75   .75   6 3 N/A   35   .75   .75   6 3 50   35   .75   .75   6 3 50   35   3 3 N/A   35   N/A   35   5 AT-Series Estimated Shipping Weights   ESTIMATED SHIPPING WEIGHTS - BURNERS (ALL MODELS)   IMPORTANT NOTES:   • All weights are in pounds.   • All weights are subject to change   without notice.   • To determine total unit weight, add   the appropriate burner weight to the   appropriate base unit weight   (as listed in performance information   tables).   300 -   625   626 -   938   939 -   1250   1251 -   1875   1876 -   2500   2501 -   3125   3126 -   5000   Input MBH   GAS   BURNER   Weight   155   190   230   290   300   340   340   22.1 -   36   2.5 -   4.5   4.6 -   6.7   6.8 -   8.9   220   939 -   1250   6.8 -   8.9   9.0 -   13.4   220   1251 -   1875   9.0 -   13.4   13.5 -   17.9   310   1876 -   2500   13.5 -   17.9   18 -   22   Input GPH   Weight   #2 OIL BURNER   125   300 -   625   2.5 -   4.5   125   626 -   938   4.6 -   6.7   360   2501 -   3125   18 -   22   385   3126 -   5000   22.1 -   36   Input MBH   COMBINATION   GAS / #2 OIL   BURNER   Input GPH   Weight   200   240   270   360   400   450   500   AT-Series Selection Guide   To create a complete air turnover unit, choose one base unit and one burner/manifold package using the tables on the   following pages. Prices apply for natural gas or LPG units.   1. Choosing A Base Unit Package   Base Unit Package choice is based on model choice. First locate the correct set of tables on the following pages which corresponds to the required   type of unit. Locate CFM and MBH requirements on the appropriate set of tables to determine the unit model. If more than one model is applicable,   choose the smaller model.   Btu/h Output Required = CFM * 1.08 * Temperature Rise   MBH = Btu/h / 1,000   2. Choosing A Burner/Manifold Package   Choose Burner/Manifold Package based on input, burner type and insurance requirements. Choose a Burner/Manifold Package that can fulfill the   maximum output of the model. Note that burner INPUTS are listed rather than outputs.   Burner Input = Burner Output / .8   Tables A: Air Turnover Heating Unit Performance Information   (Additional configurations are available upon request.)   AT-136   AT-248   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   Temp. Rise   Range (°F)   CFM   Motor (HP)   CFM   Motor (HP)   4,500 1 (1 motor)   9,000 2 (1 motor)   12,000 3 (1 motor)   240   240   240   450   450   450   49 to 93   25 to 46   19 to 35   2,225   2,280   2,305   22,000 3 (2 motors)   35,000 5 (2 motors)   45,000 5 (2 motors)   45,000 5 (2 motors)   240   520   560   560   750   10 to 32   14 to 26   12 to 26   12 to 31   5,990   6,145   6,270   6,270   1,000   1,250   1,500   AT-148   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   3,255   3,300   AT-254   Temp. Rise   Range (°F)   CFM   Motor (HP)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   7,670   8,060   Temp. Rise   Range (°F)   CFM   Motor (HP)   10,000 3 (1 motor)   16,000 3 (1 motor)   240   240   450   750   22 to 42   14 to 43   40,000 5 (2 motors)   60,000 7.5 (2 motors)   65,000 7.5 (2 motors)   560   600   600   1,750   2,250   2,500   13 to 41   9 to 35   9 to 36   AT-154   8,310   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   3,880   3,940   4,115   4,220   Temp. Rise   Range (°F)   CFM   Motor (HP)   AT-260   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   10,870   11,135   11,135   14,000 3 (1 motor)   22,000 5 (1 motor)   30,000 7.5 (1 motor)   30,000 7.5 (1 motor)   240   240   520   560   450   750   1,000   1,250   16 to 30   10 to 32   16 to 31   17 to 39   Temp. Rise   Range (°F)   CFM   Motor (HP)   54,000 5 (2 motors)   61,000 7.5 (2 motors)   74,000 7.5 (2 motors)   600   720   720   3,000   4,000   4,000   10 to 51   11 to 61   9 to 50   AT-236   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   3,945   3,990   Temp. Rise   Range (°F)   CFM   Motor (HP)   AT-272   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   11,720   12,185   12,185   Temp. Rise   Range (°F)   9,000 1 (2 motors)   18,000 2 (2 motors)   24,000 3 (2 motors)   240   240   520   450   750   1,000   25 to 46   12 to 39   20 to 39   CFM   Motor (HP)   4,115   62,000 5 (2 motors)   88,000 10 (2 motors)   100,000 10 (2 motors)   600   720   720   3,000   4,500   4,500   9 to 45   8 to 47   7 to 42   AT-242   Output   (MBH)   Output   (MBH)   Temp.   Rise   Base Unit   Weight   (lbs.)   CFM   Motor (HP)   Minimum Maximum Range (°F)   21,000 2 (2 motors)   31,000 3 (2 motors)   31,000 3 (2 motors)   240   520   560   750   1,000   1,250   11 to 33   16 to 30   17 to 37   4,990   5,115   5,240   6 Tables B: Air Turnover Heating Unit with Filtration Performance Information   (Additional configurations are available upon request.)   AT-136   AT-248   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   Temp. Rise   Range (°F)   CFM   Motor (HP)   CFM   Motor (HP)   4,500 1 (1 motor)   9,000 3 (1 motor)   12,000 5 (1 motor)   240   240   240   450   450   450   49 to 93   25 to 46   19 to 35   2,425   2,505   2,520   22,000 3 (2 motors)   35,000 5 (2 motors)   45,000 7.5 (2 motors)   45,000 7.5 (2 motors)   240   520   560   560   750   10 to 32   14 to 26   12 to 26   12 to 31   6,190   6,345   6,575   6,730   1,000   1,250   1,500   AT-148   Output   (MBH)   Minimum Maximum   240   240   Output   (MBH)   Base Unit   Weight   (lbs.)   3,455   3,470   AT-254   Temp. Rise   Range (°F)   CFM   Motor (HP)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   7,870   8,310   Temp. Rise   Range (°F)   CFM   Motor (HP)   10,000 3 (1 motor)   16,000 5 (1 motor)   450   750   22 to 42   14 to 43   40,000 5 (2 motors)   60,000 10 (2 motors)   65,000 10 (2 motors)   560   600   600   1,750   2,250   2,500   13 to 41   9 to 35   9 to 36   AT-154   8,560   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   4,080   4,140   4,210   4,420   Temp. Rise   Range (°F)   CFM   Motor (HP)   AT-260   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   11,070   11,335   11,385   Temp. Rise   Range (°F)   14,000 3 (1 motor)   22,000 5 (1 motor)   30,000 10 (1 motor)   30,000 10 (1 motor)   240   240   520   560   450   750   1,000   1,250   16 to 30   10 to 32   16 to 31   17 to 39   CFM   Motor (HP)   54,000 5 (2 motors)   61,000 7.5 (2 motors)   74,000 10 (2 motors)   600   720   720   3,000   4,000   4,000   10 to 51   11 to 61   9 to 50   AT-236   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   4,145   4,240   AT-272   Temp. Rise   Range (°F)   CFM   Motor (HP)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   9,000 1 (2 motors)   18,000 3 (2 motors)   24,000 5 (2 motors)   240   240   520   450   750   1,000   25 to 46   12 to 39   20 to 39   7.5 (2 mo-   tors)   62,000   600   3,000   9 to 45   12,160   4,270   88,000 10 (2 motors)   100,000 15 (2 motors)   720   720   4,500   4,500   8 to 47   7 to 42   12,385   12,515   AT-242   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   21,000 3 (2 motors)   31,000 5 (2 motors)   31,000 5 (2 motors)   240   520   560   750   1,000   1,250   11 to 33   16 to 30   17 to 37   5,240   5,270   5,445   Tables C: Air Turnover Cooling Unit with Filtration Performance Information   (For cooling applications, consult factory. Base Unit Weights do not account for inclusion of cooling coils or exclusion of heat exchanger.   Additional configurations are available upon request.)   AT-136   AT-248   CFM   Motor (HP)   Base Unit Weight (lbs.)   CFM   Motor (HP)   Base Unit Weight (lbs.)   4,500   9,000   12,000   1 (1 motor)   3 (1 motor)   5 (1 motor)   2,425   2,505   2,520   22,000   35,000   45,000   45,000   3 (2 motors)   5 (2 motors)   7.5 (2 motors)   7.5 (2 motors)   6,190   6,345   6,575   6,730   AT-148   AT-254   CFM   Motor (HP)   Base Unit Weight (lbs.)   CFM   Motor (HP)   Base Unit Weight (lbs.)   10,000   16,000   3 (1 motor)   5 (1 motor)   3,455   3,470   40,000   60,000   65,000   5 (2 motors)   10 (2 motors)   10 (2 motors)   7,870   8,310   8,560   AT-154   CFM   Motor (HP)   Base Unit Weight (lbs.)   AT-260   14,000   22,000   30,000   30,000   5 (1 motor)   5 (1 motor)   10 (1 motor)   10 (1 motor)   4,080   4,140   4,210   4,420   CFM   Motor (HP)   Base Unit Weight (lbs.)   54,000   61,000   74,000   5 (2 motors)   7.5 (2 motors)   10 (2 motors)   11,070   11,335   11,385   AT-236   AT-272   CFM   Motor (HP)   Base Unit Weight (lbs.)   CFM   Motor (HP)   Base Unit Weight (lbs.)   9,000   18,000   24,000   2 (1 motors)   3 (2 motors)   5 (2 motors)   4,145   4,240   4,270   62,000   88,000   100,000   7.5 (2 motors)   10 (2 motors)   15 (2 motors)   12,160   12,385   12,515   AT-242   CFM   Motor (HP)   Base Unit Weight (lbs.)   21,000   31,000   31,000   3 (2 motors)   5 (3 motors)   5 (3 motors)   5,240   5,270   5,445   7 Tables D: Air Turnover Heating/Cooling Unit with Filtration Performance Information   (For cooling applications, consult factory. Base Unit Weights do not account for inclusion of cooling coils or exclusion of heat exchanger.   Additional configurations are available upon request.)   AT-136   AT-248   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   Temp. Rise   Range (°F)   CFM   Motor (HP)   CFM   Motor (HP)   4,500 1.5 (1 motor)   240   240   240   450   450   450   49 to 93   25 to 46   19 to 35   2,425   2,505   2,520   22,000 5 (2 motors)   35,000 7.5 (2 motors)   45,000 10 (2 motors)   45,000 10 (2 motors)   240   520   560   560   750   10 to 32   14 to 26   12 to 26   12 to 31   6,190   6,345   6,575   6,730   9,000   5 (1 motor)   1,000   1,250   1,500   12,000 5 (1 motor)   AT-148   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   3,455   3,470   AT-254   Temp. Rise   Range (°F)   CFM   Motor (HP)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   10,000 5 (1 motor)   16,000 7.5 (1 motor)   240   240   450   750   22 to 42   14 to 43   40,000 5 (2 motors)   60,000 10 (2 motors)   65,000 15 (2 motors)   560   600   600   1,750   2,250   2,500   13 to 41   9 to 35   9 to 36   7,870   8,310   8,560   AT-154   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   AT-260   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   11,070   11,335   11,385   Temp. Rise   Range (°F)   14,000 5 (1 motor)   22,000 7.5 (1 motor)   30,000 10 (1 motor)   30,000 10 (1 motor)   240   240   520   560   450   750   1,000   1,250   16 to 30   10 to 32   16 to 31   17 to 39   4,080   4,140   4,210   4,420   CFM   Motor (HP)   54,000 7.5 (2 motors)   61,000 10 (2 motors)   74,000 15 (2 motors)   600   720   720   3,000   4,000   4,000   10 to 51   11 to 61   9 to 50   AT-236   AT-272   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   9,000 1.5 (2 motors)   18,000 5 (2 motors)   24,000 5 (2 motors)   240   240   520   450   750   1,000   25 to 46   12 to 39   20 to 39   4,145   4,240   4,270   62,000 7.5 (2 motors)   88,000 15 (2 motors)   100,000 15 (2 motors)   600   720   720   3,000   4,500   4,500   9 to 45   8 to 47   7 to 42   12,160   12,385   12,515   AT-242   Output   (MBH)   Minimum Maximum   Output   (MBH)   Base Unit   Weight   (lbs.)   Temp. Rise   Range (°F)   CFM   Motor (HP)   21,000 5 (2 motors)   31,000 7.5 (2 motors)   31,000 7.5 (2 motors)   240   520   560   750   1,000   1,250   11 to 33   16 to 30   17 to 37   5,240   5,270   5,445   Installation Code and Annual Inspections:   All installations and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and ser-   vice of equipment sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals   and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate   optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON®   equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon.   Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is   available through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the   Installation, Operation and Service Manual.   This product is not for residential use.   This document is intended to assist licensed professionals in the exercise of their professional judgement.   Roberts-Gordon, LLC   1250 William Street   P.O. Box 44   Buffalo, NY 14240-0044 USA   Telephone: 716.852.4400   Fax: 716.852.0854   European Office:   Roberts Gordon Europe Limited   Telephone: +44(0)121 506 7700   Fax: +44(0)121 506 7701   Toll Free: 800.828.7450   © 2007 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form   or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information   storage and retrieval systems – without written permission of Roberts-Gordon, LLC.   Printed in U.S.A.   CATDSGNA   2M 1107 Orig   |