C S -W 7 D K R C U -W 7 D K R / C S -W 9D K R C U -W 9D K R / C S -W 1 2 D K R C U -W 1 2 D K R
9 Operating Instructions
Thank you for purchasing Panasonic Air Conditioner
SAFETY PRECAUTIONS
I Definition
To prevent personal injury,
injury to others and property
damage, the following
instructions must be
followed.
Installation Precautions
Warning
Do not install, remove and reinstall the unit by yourself.
Incorrect operation due to
failure to follow instructions
will cause harm or damage,
the seriousness of which is
classified as below:
•
Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or
specialist for the installation work.
Caution
•
•
•
This air conditioner must be earthed. Improper grounding will cause electric shock.
Ensure that the drainage piping is connected properly. Otherwise, water will leak.
Warning
Current leakage protection equipment must be installed. Otherwise, electric shock or fire may
occur.
This sign warns of death
or serious injury.
•
Do not install the unit in a potentially explosive atmosphere.
Operation Precautions
Caution
Warning
•
•
•
•
•
Do not share power outlet.
Do not modify power cord.
Do not use an extension cord.
Do not operate with wet hands.
•
•
•
Insert the power plug properly.
Use specified supply cord.
This sign warns of injury
or damage to property.
If the supply cord is damaged or needed
to be replaced, it must be replaced by
the manufacturer or its service agent or
a similarly qualified person in order to
avoid a hazard.
The instructions to be
followed are classified by
the following symbols:
Do not operate or stop the unit by inserting
or pulling out the power plug.
•
•
Do not insert finger or other objects into the
indoor or outdoor unit.
•
•
Remove the batteries if the unit is not
going to be use for a long period of time.
Do not attempt to repair the unit by
yourself.
New batteries of the same type must be
inserted following the polarity stated to
prevent malfunction of the remote control.
•
•
Do not use rechargeable (Ni-Cd) batteries.
This symbol denotes
an action that is
PROHIBITED.
Keep the remote control away from infants
and small children to prevent them from
accidentally swallowing the batteries.
•
In case of emergency or abnormal
condition (burnt, smell, etc) occurs, turn
off the power supply and unplug.
Caution
These symbols denote
actions that are
COMPULSORY.
•
•
•
•
•
•
Do not pull the cord to
disconnect the plug.
•
Ventilate the room regularly.
•
Pay attention as to whether the
installation rack is damaged after long
period of usage.
Do not wash the unit with water, benzene,
thinner or scouring powder.
Do not use for other purposes such as
preservation of food.
•
•
Switch off the power supply and unplug
before cleaning or servicing.
Do not use any combustible equipment at
airflow direction.
Turn off the power supply and unplug if
the unit is not used for a long period of
time.
Do not sit or place anything on the indoor
or outdoor unit.
Do not expose directly to cold air for a
long period.
Operation Condition (OC)
Use this air conditioner under the following temperature
range.
Safety Regulation
The appliance is not intended for use by young children or infirm
person without supervision. Young children should be supervised to
ensure that they do not play with the appliance.
Indoor
Outdoor
DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature
Replacement or installation of power plugs shall be performed by
authorized/qualified personnel only. The wires in this mains lead are
coloured in accordance with the following code:
(GB Standard)
DBT WBT DBT WBT
Maximum Temperature (COOL)
Maximum Temperature (HEAT)
Minimum Temperature (COOL)
Minimum Temperature (HEAT)
32
30
16
16
23
–
43
24
16
-5
26
18
11
-6
11
–
Different countries may have different colour coding for the wires.
39
CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU-W12DKR
HOW TO OPERATE
I Operation Details
Auto, Heat, Cool, Dry
AUTO - Automatic Operation
•
The unit will automatically select the
operation mode according to the
room temperature.
•
Once the operation mode is
selected, the unit will operate at the
standard setting temperature as
shown:
1
operation.
Standard
Start the
Room
Operation
mode
setting
temperature
temperature
23°C & above
Below 23°C
Below 20°C
Cool
Dry
25°C
22°C
21°C
button
Heat
2
•
You may press
or
Select the
desired
operation.
to change the standard setting
temperature to “HI” or “LO” as
shown:
Operation mode
HI
LO
AUTO
Cool
27°C
23°C
Dry
24°C
23°C
20°C
19°C
DRY
HEAT
Heat
COOL
HEAT - Heating Operation
•
Enables you to enjoy the warming
effect at your preferred setting
temperature.
•
The range of temperature can be
selected from 16°C ~ 30°C.
3
temperature.
Set the
COOL - Cooling Operation
•
Enables you to enjoy the cooling
effect at your preferred setting
temperature.
•
The range of temperature can be
selected from 16°C ~ 30°C.
DRY - Soft Dry Operation
G Supersonic air purifying device (super alleru-buster) operates
automatically while the air conditioner is switched on.
•
Enables you to set the desired
temperature at low fan speed which
provides you with the dehumidifying
surroundings.
G Powerful, Quiet and Ion operations could be activated in all
operation modes.
•
The range of temperature can be
selected from 16°C ~ 30°C.
OFF/ON
G Press
button again to stop the operation.
Hint
G
To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
Troubleshooting
G
The room has a peculiar odour.
®
This may be a damp smell emitted by the wall, carpet, furniture or
clothing in the room.
G
Air conditioner does not cool or heat efficiently.
®
®
®
®
Ensure the temperature has been set correctly.
Ensure windows and doors have been closed properly.
Ensure filters are cleaned or replaced when necessary.
Ensure inlet and outlet vents of outdoor unit have not been obstructed.
G
In heating operation Power indicator blinking, no
warm air discharge.
®
Defrost operation at outdoor unit, maximum 12 minutes.
41
CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU-W12DKR
HOW TO OPERATE
I Operations Details
POWERFUL
Pow erful, Quiet, Ion, Fan Speed,
Air Sw ing
•
To achieve setting temperature
quickly. It will operate for 15 minutes
and return to the previous setting.
QUIET
To provide a quiet environment.
POWERFUL
Enables
•
ION
Enables ion
operation.
ION
powerful
operation.
•
To provide fresh air effect by
producing negative ions.
FAN SPEED
•
To provide you with the various fan
speed selections.
•
•
There are 3 levels of fan speed in
addition to automatic fan speed.
FAN SPEED
Select fan speed.
Automatic fan speed:
The speed of the indoor fan is
automatically adjusted according to
the operation.
AIR SWING
•
To ventilate air in the room.
•
There are 5 selections in addition to
automatic vertical air flow direction.
•
If automatic vertical airflow direction
has been set, the louver swings up
and down automatically.
AIR SWING
Adjust the
QUIET
Enables quiet
operation.
•
•
Please do not adjust the vertical
airflow direction louver manually.
vertical airflow
direction louver.
Horizontal airflow direction louver
could be adjusted manually.
G Ion operation could be activated independently.
G Powerful and Quiet operations could not be activated at the
same time.
G Powerful, Quiet and Ion operations could be cancelled by
pressing the respective button again.
Hints
G
If you wish to have the cool air blowing directly on you, set the airflow direction downward but not for an excessive length of time,
as it may harm your health.
G
Approximately 10% of electricity can be saved if you set the temperature 1°C higher in cooling operation or 2°C lower in heating
operation than the desired temperature.
Troubleshooting
G
ION indicator on the indoor unit is blinking.
®
Press ION button twice. If the indicator is still blinking, please consult
the dealer.
G
G
Indoor fan stops occasionally during Automatic Fan
Speed setting.
®
®
This is an advanced feature that helps to remove smell from the
surrounding area during operation.
Indoorfanstopsoccasionallyduringheatingoperation.
To avoids unintended cooling effect.
42
CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU-W12DKR
HOW TO OPERATE
I Operation Details
Timer
TIMER
•
Use the ON timer to turn on the air
conditioner at the desired time. This
will give you a cooling or warming
environment, e.g. when you return
from work or wake up.
•
•
When the ON timer is set, operation
will start 15 minutes for COOL/DRY
or 30 minutes for AUTO/HEAT
before the actual set time.
Use the OFF timer to stop the air
conditioner operation at the desired
time. This can save electricity while
you are going out or sleeping.
1
Select ON or
OFF timer.
•
•
The set timer will repeat daily once
it is set.
If there is a power failure, you can
press SET button to restore the
previous setting once the power is
resumed.
2
desired time.
Set the
•
If the timer is cancelled, you can
restore the previous setting by
pressing SET button.
3
Confirm the
setting.
CANCEL
Cancel the
selected timer.
G Ensure the clock on the remote control has been set
correctly.
G You could use the ON and OFF timers at the same time.
G To cancel either the ON or OFF timer, press
then press
or
,
.
Hint
G
G
Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format.
For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.
Troubleshooting
G
TIMER indicator always on.
®
®
Timer is activated and the setting will repeat itself daily.
G
POWER indicator is blinking 30 minutes before ON
timer is activated.
The unit is determining the operation mode by sensing the room
temperature. This happens when it has been set to AUTO operation
mode.
43
CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU-W12DKR
CARE & CLEANING
I Washing Instructions
•
•
•
Do not use benzene, thinner or
scouring powder.
Switch off the power supply
Use soaps or neutral household
detergent ( pH7) only.
before cleaning
≃
Do not use water with temperature
higher than 40°C.
FRONT PANEL
Raise and Pull to remove.
Wash and dry.
INDOOR UNIT
•
Wipe the unit gently with a soft, dry
cloth.
AIR FILTER
•
It is recommended to clean the air
filters once every 2 weeks.
AIR FILTER
Vacuum, wash and dry.
•
Purchase the replacement filter if it
is damaged.
Part no.: CWD001144
SUPER ALLERU-BUSTER
•
It is recommended to clean the filter
every 6 months.
•
Replace the filter every 3 years or
purchase the replacement filter if it
is damaged.
Remove
Part no.: CZ-SA13P
F UL
ION
POWER
ER QUIET
ER TIM
POW
IONIZER
Remove
•
It is recommended to clean the
ionizer every 6 months.
I Preparation for extended
Non-operation
•
Operate the unit for 2~3 hours using
ion operation to dry the internal parts.
INDOOR UNIT
Wipe gently.
SUPERSONIC AIR
•
•
Turn off the power supply and unplug.
Remove the remote control batteries.
PURIFYING DEVICE
Vacuum the super
alleru-buster filter.
I Pre-season Inspection
•
This inspection is recommended
before operating the air conditioner
at every season.
IONIZER
Clean with cotton
bud.
•
•
•
Check if the remote control batteries
needed to be replaced.
Remove
Ensure there is no obstruction at all
air intake and outlet vents.
After the start of operation for 15
minutes, it is normal if the
temperature differences between
air intake and outlet vents at indoor
unit is:-
Operation
Cooling
Temperature
8°C
Vacuum, wash and
dry the frame.
Heating
14°C
Hints
G
Clean the filter regularly as dirty filters will cause unpurified air, low cooling or heating capacity, unpleasant smells and higher
energy consumption.
G
The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an
authorized dealer to perform seasonal inspections in addition to regular cleaning.
44
|