S I M P L Y
A M A Z I N G
USER’S GUIDE
Table Top Air Purifier
AIR7
Series
•IMPORTANT•
SAVE THIS BOOKLET!
Includes:
• Warranty
• Safety Warnings
• Parts List
• Operating Instructions
• Accessories List
• Trouble Diagnosis
2
5
3
6
1
4
7
Operation
5
1
How Your Electronic Air Purifier Works
4
2
Polluted air enters the air purifier through the front grill. As the air is
pulled through, a pre-filter helps trap large particles (hair, lint, etc.). Then
an electronic ionizer electrostatically charges smaller particles (dust,
smoke, pollen). The positive charged particles then enter the negatively
charged electronic cell, where the aluminum plates attract and retain the
particles. It works like a powerful magnet and the particles remain until
the electronic cell is cleaned. The air then passes through a charcoal
odor absorber that helps remove household odors. Next, the negative
ion generator releases negative ions to freshen the air. Finally,
3
1. MAIN POWER SWITCH: Turn the unit on by sliding the power switch
to the blower speed you prefer: High ( ) for maximum cleaning -
Medium ( ) for normal use - Low ( ) for quiet operation.
electronically cleaned air passes back into the room through the top grill.
2. FRAGRANCE CARTRIDGE: Fragrance compartment switch ejects
drawer for access to fragrance cartridge. Insert fragrance cartridge
and close drawer. One fragrance cartridge included.
3. IONIZER POWER SWITCH: Turns the ionizer ON or OFF. The
indicator light will glow green when ON and functioning properly.
4. POWER INDICATOR LIGHT: The indicator light will glow green when
the unit is operating normally. It will flash red when the collector cell
requires cleaning. NOTE: The light will glow red for a moment
when unit is first turned on. This is normal and only a test of the
system.
5. AIR DIRECTION CONTROL: Slide switch on top of unit controls the
louvers and enables you to direct airflow to desired areas.
NOTE: You may notice an occasional infrequent sharp snapping
sound coming from your unit. This is a normal occurrence called
“arcing” and results as large particles of dust are collected in the
ionizing-collecting cell. Should prolonged or continuous arcing
occur, the ionizing-collecting cell should be thoroughly cleaned
and dried completely (See “Cleaning Collector Cell”).
PRE-FILTER
ELECTRONIC CELL
CHARCOAL ODOR POWERFUL FAN
ABSORBER
Instructions
WARNING: DO NOT USE THIS ELECTRONIC AIR PURIFIER WHEN
OXYGEN TANKS ARE BEING USED OR IN THE PRESENCE OF
COMBUSTIBLE GASES.
ELECTRONIC IONIZER
NEGATIVE ION GENERATOR
3
IMPORTANT NOTES:
every two months or as needed. IMPORTANT: DO NOT wash the
charcoal odor absorber. Replace, if necessary.
G
Your air purifier works best if you leave it in operation all the time.
G
Replacing Cell After Cleaning
1. Snap in the charcoal odor absorber. (fig. 3)
2. Slide in the pre-filter. (fig. 4)
3. Slide cell into cabinet, using handles. (fig. 2)
4. Replace front grill. Unit is now ready for operation. (fig. 1)
NOTE: An occasional “arcing” sound is normal when operating the
unit immediately after cleaning the cell and should stop after a few
minutes of operation.
Place or mount the air purifier near a standard electrical outlet. Do
not block either the air intake or outlet grill.
G
Never place your air purifier on soft surfaces (such as bed, sofas or
carpet), near computers or next to sources of heat (such as stove
tops, ovens, etc.)
G
Make sure the front grill is securely locked in place.
G
A safety switch is installed behind the grill of your electronic air
purifier. If the grill is not properly secured in place, the unit will not
operate. If your unit fails to operate, remove the front grill and reinstall
it, being sure that the lower right-hand side of the grill (next to the
control panel) is firmly locked in place.
Replacing Fragrance Cartridge
1. Open cartridge compartment by sliding the compartment release switch.
(fig. 5)
G
Plug the power cord into the nearest available standard electrical
outlet. (See data label on bottom of your air purifier for electrical
specifications and power consumption.)
2. Remove fragrance disk from center of cartridge and replace with a
new one. (fig. 6)
G
Do not use an extension cord to supply power to your air purifier.
3. Close compartment until it locks. (fig. 7)
NOTE: One fragrance cartridge is included.
Cleaning
Troubleshooting Guide
The Cabinet
Service problems that appear to be major can often be solved easily. You
can be your own troubleshooter by reviewing the chart below. It pinpoints
problems and how to correct them. Remember, check the simple things first.
You can clean the air purifier cabinet with mild, non-abrasive cleanser and a
soft cloth. IMPORTANT: Unplug the unit from its electrical power source.
Do not spray cleansers or furniture polish into the louver or grill areas.
PROBLEM
UNIT DOES NOT TURN
CHECK
1. Power Cord
WHAT TO DO
1. Plug in power cord
Collector Cell
Indicator light is green under normal operation and flashes red
when the cell requires cleaning. To clean, proceed as follows:
ON
2. Selector Switch
2. Set selector switch
for desired blower
speed.
The red "WASH CELL" light will flash or illuminate when it is
time to clean your cell. However, it is recommended that every four to
eight weeks or if snapping sounds become frequent, clean your
electronic air purifier. Your electronic air purifier is still filtering the air
when the red light illuminates. Cleaning your electronic air purifier is a
snap too... and a must for efficient operation.
3. Reinsert front grill
until it is flush with
cabinet front. Tap grill
lightly, if necessary, to
fully insert.
3. Front Grill
1. Turn the unit off and unplug it from the electric power source. If wall
mounted, remove unit from wall.
Wash ionizer/collector
cell. Make sure it is
thoroughly clean & dry
before re-installing it.
INDICATOR LIGHT ON
UNIT IS FLASHING RED
OR HAS TURNED RED
Ionizer/collector cell
2. Remove front grill by unscrewing the retainer screw under the grill on
the cabinet bottom. (fig. 1)
3. Pull the cell out of the cabinet by using the two small handles on the
front of the cell. (fig. 2)
UNIT DOES NOT
Wash cell
Ionizer/collector cell
Ionizer/collector cell
REMOVE POLLUTANTS
UNIT SPARKS,
A little is normal. Make
sure the cell is
thoroughly dry before
re-installing it.
4. Snap off the charcoal odor absorber from the back of the cell. Change
as necessary for continued odor removal. (fig. 3)
CRACKLES AND POPS
5. Slide off pre-filter. This can be cleaned with the cell and reused. (fig. 4)
NOTE: Handle the electronic cell with care. Damaged metal plates
and/or broken wires will cause the air purifier to malfunction. (Do
not wash charcoal odor absorber; it is disposable.)
Cleaning with Assail-A-Cell® Cell Cleaner:
6. Using Assail-A-Cell® Cleaner, thoroughly saturate the cell and pre-
filter. Be sure to spray between each cell plate and cover every
surface. Allow product to soak for a few minutes, not allowing it to dry.
Rinse thoroughly with water. For extremely heavy deposits, repeat the
process.
If it persists, clean cell.
If that doesn’t help, cell
may be damaged and
needs replacing.
DOES NOT REMOVE
ODOR
Old Charcoal Odor
Absorber
Check all the above
points
Replace Charcoal
Odor Absorber.
UNIT STILL DOES NOT
OPERATE PROPERLY
Return unit to the
Service Center.
ALL OTHER SERVICING SHOULD BE DONE BY AN
ORECK AUTHORIZED SERVICE CENTER.
IMPORTANT: Dry the collection cell thoroughly outside of the
air purifier before reinstalling it into the air purifier. Ensure
that all areas including corners and areas that may trap
water are dry before reinstalling into the air purifier. DO NOT
place a wet or damp collection cell in the air purifier.
CALL CUSTOMER SERVICE HOT LINE
US:1-800-989-3535 Canada: 1-888-676-7325
Whenever calling, please be sure to have your model and serial
number from data plate.
Replacing the Charcoal Odor
Absorber (Optional)
Accessories
In addition to air purification, your Oreck provides the additional benefit
of odor removal. The odor removal function is optional. Your Oreck Air
Purifier will continue to remove harmful airborne particles with its
permanent electronic collector cell even if you choose not to use the
optional charcoal odor absorber.
ITEM
1.
2.
3.
4.
PART #
Pre-Filter
7780-8041
09-5510-7065
AT4PK7
Ionizer/Collector Cell
Charcoal Odor Absorber (Set of 4)
Wall Mounting Kit
8660-0201
Odor absorption effectiveness will gradually deteriorate over time unless
the charcoal odor absorber is replaced. While every environment is
different, Oreck suggests that the charcoal odor absorber be replaced
5.
Oreck Fresh Air® Scent Cartridges
Spring Mulberries®, 8pk.
FA2PK
FA3PK
Blooming Jasmine®, 8pk.
© 2006 Oreck Holdings, LLC. All Rights Reserved. All word mark, logos, product configurations, and registered trademarks are
owned and used under the authority of Oreck Holdings, LLC. 3323-3018 REV H 01/06 ECN# R-8239, R-8240