Portable Air Conditioner Owner’s manual
For ACP-1400E/H Series
2
THANK YOU
Thank you for choosing this innovative air conditioner. We suggest that you
keep this manual in a safe place for future reference. It describes the many
benefits and advanced features this unique product has to offer. Before you
use your new air conditioner you should carefully read these instructions to
maximize this product’s performance.
SAFETY INSTRUCIONS
IMPORTANT!
• The unit is designed for indoor operation.
• The installation must be in accordance with regulations of the country
where the unit is used.
If you are in any doubt about the electrical installation, have it
checked and if necessary modified by a qualified electrician.
• The air conditioner is safe. However, as with other electrical appliances, use
it with care.
• Keep out of the reach of children.
• Do not clean the air conditioner by spraying it or immersing it in water.
• Do not insert any object into openings of the air conditioner.
• Disconnect it from all electricity before cleaning the unit or any of its
components.
• Never connect the unit to an electrical outlet using an extension cord. If an
outlet is not available, one should be installed by a licensed electrician.
• Don’t lift or move by pushing the air conditioner at the rear, but always
from the front side.
WARNING
• Never operate this appliance if it has a damaged cord or plug. Do not lead
the cord over sharp edges.
• A damaged supply cord should be replaced by the manufacturer, its service
agent or a qualified person in order to avoid a hazard.
• Any service other than regular cleaning or filter replacement should be
performed by an authorized service representative. Failure to do so could
result in a loss of warranty.
3
Do not use your air conditioner under the following conditions:
• If the power cable wires are frayed or cut
• Where small children may be left unattended
• On a slope or uneven surface
• Close to a naked flame
• This product is not made for DIY repair
• If there is a risk of liquid falling on the unit
• Inside unit exposed to the weather outdoors
• Near water
• If an extension lead may become overloaded
• Where the power cable may be damaged
• Where it may be damaged by chemicals
• Where there is a risk of interference by foreign objects
4
PARTS
(1) Front panel
(2) Air outlet
(3) Control panel
(4) Rear panel
(5) Right air inlet
(6) Castor
( OLD )
(7) Left air inlet
(8) Hose connector
(9) Exhaust hose
(10) Drainage point
with rubber
water stopper
( NEW )
5
ACCESSORY
Exhaust Hose
Hose Connector
Telescopic Slide Bar Connecto(r NEW) Telescopic Slide Bar Connecto(r OLD)
Telescopic Slide Bar
Carbon Filter
Water Container
Remote Control
6
CONTROL PANEL
LED Indicator Light
1 – Ionizer & UV indicator light in green
2 – Swing indicator light in green
3 – Timer indicator light in green
4 – Sleep mode indicator light in green
5 – Fan speeds
a. Fast – indicator light in red
b. Normal - indicator light in green
c. Slow - indicator light in yellow
6 – Mode
a. Cooling – indicator light in green
b. Dehumidification – indicator light in yellow
c. heat – indicator light in red
d. Fan only – no light
7 – When the unit is working, the indicator light will be in green
8 – Water full indicator light in red
7
INSTALLATION
WARNING!
Before using the air conditioner it should be left in an upright position for at
least 2 hours. This unit can easily be moved from one room to another.
In doing so keep this in mind:
-
-
-
Ensure that the unit is positioned upright, on a level surface and 50cm
away from any obstacles.
Do not operate the unit inside the bathroom, shower, or in any other very
humid environment.
Slide the hose connector A in the hot air outlet.
-
-
Connect the hose to hose connector A by turning it clockwise (at least 5
turns).
Similarly, connect the hose to hose connector B as far as possible.
(OLD)
(NEW)
-
-
Slide the hose connector B in the telescopic slide bar connector.
Place the telescopic slide bar in the open window or door and adjust the
length to fill as much open space as possible.
(OLD)
(NEW)
-
Close the window or door as much as possible to prevent outside air
entering the room.
-
-
Ensure that the hose connector B has a free flow outside.
8
IMPORTANT!
The flexible exhaust hose can be extended from 500 to 1500mm for mounting.
This length has been designed especially according to the specifications of the
air conditioner. Do not use an extension or exchange for a different
hose as that may cause the unit to malfunction. The exhaust air must
flow freely; any blockage can lead to overheating of the air conditioner. Take
care to prevent any sharp bow or bend in the exhaust.
OPERATION
ON/OFF
Press
to switch the unit on or to switch off, a buzzer will beep, and the 2
digits display will show 72℉ as default, and the unit will run in cooling
function with turbo speed (the
light in green).
indicator light in red, the
indicator
Setting the temperature
If you want to change the set temperature press the
digit display will indicate the set temperature.
or
button. The 2
Note: Reaching the set temperature depends on the room and outdoor
climatic conditions.
Mode
Pressing the
button to switch the operating mode among ‘cooling’, ‘fan
only’, ‘dehumidification’ and ‘heat’.
Fan speed
If you prefer a constant fan speed, press the
• Fast – for the turbo speed
• Normal – for the medium speed
• Slow – for the slow speed
button successively.
9
Timer
For all of the following TIMER programming, proceed firstly with these
standard
steps:
• Press the
button briefly, the 2 digits on the control panel will show 00.
button again to program the timer for ON – when the unit is
• Press the
OFF or program the timer for OFF – when the unit is RUNNING. The time
will be increased by hour from 00, 01, 02…..24, thence go back from 24, 23,
22…..00 by each press of the
button.
• Press the
button briefly to adjust the time as 00 to cancel the timer
function.
Sleep mode
The sleep mode function adjusts the set temperature of the unit to the
thermal needs of the body falling asleep as follows:
• Default fan speed: Low
• Press the
button to operate the sleep mode. Press the
button again
in order to cancel the sleep mode. The set temperature will increase 2℉
after 1 hour and a further 2℉ after 2 hours.
• No FAN ONLY / DEHUMIDIFICATION mode under SLEEP mode operation.
Dehumidification
If the unit will be used mainly as a dehumidifier just let the warm air return in
the room. Continuous drainage (see separate chapter) is then necessary
and more efficient. Only low fan speed under dehumidifying.
Heat (optional function)
The unit features a heat pump that can heat a room on cooler days. With the
mode switch select ‘heat’ with the temperature in 68℉ as default. You can
set the desired temperature and the unit will heat until this temperature is
reached.
Do not place the unit near anything that could catch fire or be scorched.
Do not obstruct the air outlet.
10
Ionizer & UV
Press
Press
button to turn on the Ion & UV function.
button to turn off the Ion & UV function.
Air flow
The moment the air conditioner is connected to the electricity, the louvers
open then close and stay closed.
• When the ON – button is pressed, the louvers open to maximum.
• Press the
button, the louvers will swing continuously up and down.
• When the ON-button is pressed, the louvers open to maximum.
• By pressing the
button again the movement will stop and the louver
remain in that position. The direction of the air flow is then constant.
• When the OFF-button is pressed, the louvers close.
REMOTE CONTORL
The unit responds to all signals that are sent by
the remote control. There will be a beep sound
from the unit after receiving the signal. The
operation of the unit by remote control is almost
identical to the operation by the control panel. The
only exception is the temperature setting.
For setting the temperature
The temperature will be increased from
64℉, 65℉…..92℉, then go back from 92℉,
89℉…..64℉by each press.
11
AIR FILTERS
This air conditioner is equipped with two filter sets to clean the circulated
room air:
A screen filter in the both sides of the unit to remove dust particles
Clean the air filters
The screen filters should be cleaned regularly by rinsing them under running
water.
Note: When the unit is running for 100 hours, the 2 digits on the control
panel will blink to remind you that the filter needs to be cleaned. Press
and
buttons simultaneously to turn off the blinking of 2 digits.
Filter installation
• Slide out the filter frame from both sides of the unit.
• Separate the filter fixer from the filter frame.
• Remove the carbon into the filter frame.
• Fix the filter by reassembling the fixer into the filter frame.
NOTE!
The screen filter must always be used.
12
EMPTYING THE INTERNAL WATER CONTAINER
Under high humidity conditions it may be necessary to empty the internal
water container. When the internal water container is full the beep will be
alarmed in 15 times. The unit will switch off automatically and the water full
indicator will be in red.
To empty the water container do the following:
• Switch off the unit and remove the plug from the wall socket.
Do not move the unit. Doing this can result in water leakage,
damaging your floor or carpet.
• Place a water container on the floor underneath the permanent drainage
point.
• Remove the rubber water stopper from the drain and let the water run out.
• Replace the rubber water stopper, put the plug into the wall socket, and
switch the unit on. The red water full indicator should be off.
NOTE!
When the air conditioner is in use, under normal circumstances the
condensed water will evaporate and then be discharged through the hot air
outlet hose.
CONTINUOUS DRAINAGE
• Switch off the unit and remove the plug from the mains.
• Remove the rubber water stopper.
• Connect a drain tube (Φ16mm inner dimension) onto the water outlet and
extend with extra water tube if needed.
• Place the other end in a normal drain. Make sure that the tube is free from
twists and bends. The tube must decline over its entire length.
13
CLEANING
WARNING! First of all switch off the unit and remove the plug from the wall
Socket.
Clean the housing with a soft, damp cloth. Never use aggressive chemicals,
petrol, detergents or other cleansing solutions.
Clean the screen filter regularly with a vacuum cleaner.
NOTE! Never use the air conditioner without the screen filter.
STORAGE
• Empty the internal water container.
• Clean the screen filter.
• Put the unit in Fan Only mode for a few hours to ensure that the inside
becomes completely dry.
• Store the cable as shown.
(OLD)
(NEW)
Protect the unit against dust and store in a dry place, not accessible to
children.
14
TROUBLE SHOOTING
Never try to repair or dismantle the air condition yourself. Incompetent repairs
result in loss of warranty and can endanger the user and the property.
Problem
The air
Cause
No power supply.
Solution
Connect to a functioning outlet and switch
on.
conditioner
does not
function.
Timer function is active.
Deactivate TIMER function.
Close curtains.
In direct sunlight.
Windows or doors open, many
people or a heat source in the
room.
Close doors and windows, place an extra air
conditioner.
The air
conditioner does
not seem to
perform.
Dirty filter.
Clean or replace the filter.
Remove the blockage.
Air inlet or air outlet blocked.
Room temperature lower than the
selected value.
Change temperature selection.
The unit is noisy. Unit stands uneven.
Place on an even, solid surface.
The compressor
does not work.
The overheat protection is
probably active.
Wait 3 minutes until the temperature has
decreased, then turn on the unit again.
To correct problems that were not been described in this table and / or if the recommended
solutions fail to solve the problem, contact an authorized service centre.
15
16
|