K0080-1-2
PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC‐14000E, AC‐14000H
Portable Air Conditioner
Owner’s Manual
K0080-1-2
PARTS LIST
Front:
Back:
1. Control panel
5. Air filters
2. Louvers
6. Air inlets
3. Carrying handle
4. Casters
7. Exhaust air outlet
8. Cord wrap
9. Rubber plug / drainage hole
Accessories:
10. Hose adapter (goes over the
exhaust hose and into the back
of the unit)
11. Exhaust hose
12. Round connector (to be used in
between the hose and window kit
or through a wall)
13. Exhaust cap
14. Extendable window kit
15. Drain hose for continuous
drainage
16. Activated carbon filter
17. Remote control
2
K0080-1-2
INSTALLATION INSTRUCTIONS
Installing the Exhaust Hose and Window Kit:
The unit is a portable air conditioner that may be moved from room to room. Hot air must be
exhausted out of the room for the appliance to work. This can be done with the included
window kit or by cutting a hole into a wall.
1. Venting Through a Window (Using the Window Kit)
Window kit
FIG.5
•
•
Attach the round connector to the exhaust hose and secure it in place with screws.
Then, insert the other end of the exhaust hose into the window kit’s round opening.
Open your window and insert the window kit into the open gap. Adjust the size of
the kit if necessary by sliding the window across so that the window kit is securely
held into place. This technique may also be used for sash windows.
2. Venting Through a Wall
Wall or Window
Round connector
FIG.7
FIG.6
•
•
Cut a 5.95” (151 mm) diameter hole in the wall.
Insert the exhaust hose through the hole. On the other side of the wall, attach the
round connector to the exhaust hose with screws (Fig. 7). When the air conditioner
is not in use, cover the hole with the provided exhaust cap.
3
K0080-1-2
Positioning the Exhaust Hose:
•
•
•
Slide the hose adaptor over
the opening on the back of
the unit.
Then insert one end of the
exhaust hose into the
adapter.
FIG.8
Avoid kinks and bends in
the exhaust hose. This can
cause moist air to
accumulate, resulting in
overheating and
unexpected shut offs.
•
The exhaust hose may be
extended from 12” (300 mm)
to 59” (1500 mm), but for
maximum efficiency, use the
shortest hose length
FIG.9
possible.
FIG.10
WARNING!
The included exhaust hose is
specifically designed to fit the
specifications of this unit. Do not
extend it with your own hose, as
this can cause the air conditioner to
malfunction.
FIG.11
4
K0080-1-2
Installing the Activated Carbon
Filters:
1. Remove the filter frames from
the unit (left and right sides).
2. Separate the filters from the filter
frames.
3. Remove the activated carbon
filters from their plastic bags.
4. Attach the activated carbon filters
onto the filter frames.
5. Re-fix the filters to the filter
frames (make sure the active
carbon filters will be hold
properly).
6. Re-install the filter frames to the
unit.
FIG.12
5
K0080-1-2
OPERATING INSTRUCTIONS
Control Panel:
FIG.13
1. ON/OFF (power) button
2. Full water tank indicator
3. Fan mode indicator
4. Mode selection button
5. Heater indicator (AC-14000H only)
6. Fahrenheit indicator
12. Remote control receiver
13. Timer display
14. Temperature increase button
15. Timer button
16. Ionizer indicator
17. Ionizer button
7. Swing button
8. Sleep mode indicator
9. Sleep mode button
10. Temperature decrease button
11. Temperature display
18. Fan speed indicator
19. Automatic mode indicator
20. Fan speed button
21. Cooling mode indicator
6
K0080-1-2
Turning the Unit On and Off
1. Press the ON/OFF button. The unit will automatically begin operating. If the ambient
temperature is higher than 74o F, the unit will work in cooling mode. If the temperature
is at or below 74o F, the unit will work in ventilation (fan) mode.
2. At this time, the indicator lights will show any functions that are in progress. Please
note that the display window will only show ambient room temperatures ranging from
32o F to 122o F
.
3. To turn the unit off, press ON/OFF button again.
Setting the Mode/Function:
1. Press the MODE button to select the desired mode (cooling, fan or heating). Heating
mode is only available on the AC-14000H.
2. The selected mode’s indicator light will turn on.
Setting the Temperature:
1. Press the “Up” or “Down” button to change the set temperature.
2. The display window will indicate the set temperature. If no temperature is set, the
display will show the ambient room temperature.
3. Please note that the default temperature for cooling is 75 o F and 68 o F for heating.
Setting the Fan/Ventilation Speed:
1. Press the SPEED button to select the desired fan speed (high, medium or low). The
desired fan speed will show on the display screen.
2. If the unit is in AUTO mode, it will automatically choose the fan speed depending on the
room’s ambient temperature.
Setting the Timer:
1. Press the TIMER button to set the desired number operating hours (from 1 to 24 hours).
The display will show the number of hours being set as you press the TIMER button. If
the TIMER is not set, the unit will work continuously.
2. By pressing the timer but without selecting any other modes or settings, you can set the
number of hours to be delayed before the unit turns on. For example, if you set the
timer to “2,” the unit will automatically turn on after 2 hours.
7
K0080-1-2
Sleep Mode:
1. When in cooling mode, press the SLEEP button. The set temperature will increase 2o F
on the first hour, another 2o F on the second hour, and then maintain that temperature.
2. When in heating mode, press the SLEEP button. The set temperature will decrease 2o
F on the 1st hour, another 2o F on the second hour, and then maintain that temperature.
3. In sleep mode, the fan will be automatically set to low. By pressing the SLEEP button
again, the set temperature and fan speed will revert back to previous settings.
4. The unit will shut down automatically after it has been in sleep mode for 12 hours.
5. Sleep mode will not work when the unit is in fan, dehumidification or auto mode. It will
only work in cooling or heating mode.
Swing Function
1. To activate the unit’s swinging louvers, press the SWING button. The louvers will rise in
3 different angles: 45°, 60°, and 75°.
2. Once the air conditioner is turned on, the louvers will rise to a 75° first, and then
automatically return to 45°.
45o
60 o
75 o
FIG. 14
Dehumidification Function:
When the air conditioner is in dehumidification mode, the temperature cannot be adjusted,
and the fan speed will be automatically set to low.
Heating Mode:
When the air conditioner is in heating mode, ambient warm air is recycled and used to heat
your immediate area. The exhaust pipe will still need to be fitted onto the unit in order
for the cold air to be removed. When in heating mode, the machine can be set on HIGH
or LOW speed.
8
K0080-1-2
Ionizer:
Press IONIZIER button to activate the ionizer function. This will remove harmful particles
from the air.
Error Messages:
If there is an error with the air conditioner, the LCD screen will display “E1” or “E2.” If either
of these error messages appears, please contact the manufacturer or a service center.
All of the above functions can be controlled with
the included remote.
The remote requires 2 AAA batteries.
FIG.15
Please Note:
1. To prolong the life of the compressor, after turning off the unit, please wait at least
3 minutes before turning it back on.
2. The cooling system will turn off if the ambient temperature is lower than the set
temperature. However, the fan will continue operating at the set level. Once the
ambient temperature rises above the set temperature, cooling will resume.
3. The heating system will turn off if the ambient temperature is higher than the set
temperature. The ventilation fan will continue operating at the set level. Once the
ambient temperature drops below the set temperature, heating will resume.
4. This machine is equipped with an anti-frost function. When using the heating function in
low temperatures, the heater will occasionally stop heating in order to melt any frost
that has accumulated within the air conditioner. Normal operation will resume in a few
moments.
9
K0080-1-2
DRAINING THE UNIT
During the cooling process, some water will be extracted from the air and stored within
the unit’s water reservoir.
If the water reservoir is full, both the compressor and motor will stop and the unit will
beep (press any button to stop the beeping sound). The full water tank indicator light
will also start flashing.
To resume cooling, empty the reservoir by following these steps:
1. Turn off the air conditioner and unplug
it from the wall socket. To prevent
water leakage, avoid moving the unit
when full.
2. Place a container (such as a small pan)
underneath the drainage hole.
3. Remove the drain knob and rubber
plug from the drainage hole and allow
the water to drain out.
4. When the container is almost full, place
the rubber plug back into the drainage
hole, empty the container, and place
the drain knob back over the rubber
plug.
5. Repeat these steps until the water
reservoir is completely empty.
FIG.16
6. Replace the rubber plug and make
sure it is firmly in place.
7. Turn the unit back on. The full tank
indicator light should now turn off.
10
K0080-1-2
For Continuous Drainage:
•
Remove the drain knob and rubber
plug from the drain hole and retain it
for future use.
•
•
Connect the included drain tube to the
drain hole.
Connect the other end of the tube to a
drain (see Fig. 18).
FIG.17
•
The drain tube may be extended by
adding an extension tube with a
suitable connector.
FIG.18
Please Note:
1. The drain must be at or below the
level of the drainage port.
2. The full water tank indicator will not
work when the unit is being
continuously drained.
FIG.19
3. To extend the drain tube, you can
connect it with another hose with an
overall diameter of approximately
0.7” (18 mm).
(OD:18MM)
11
K0080-1-2
For Heating Mode (AC-14000E Only):
While using the heating function, please
note the following:
1. In order to properly exhaust cool
air, make sure the exhaust hose
and window kit are properly
installed (refer to page 4 for
instructions).
2. Set up the air conditioner for
continuous drainage using the
included drain tube (refer to page
12 for instructions).
FIG.20
3. The working range for the heating
function is 45° F to 77° F The unit
.
optimal heating
may not provide
if used in temperatures outside this range.
12
K0080-1-2
MAINTENANCE INSTRUCTIONS
Always unplug the air conditioner from the power supply before cleaning.
To maximize the efficiency of the air conditioner, regularly clean the unit.
Cleaning the Housing:
•
•
Use a soft, damp cloth to wipe the body clean.
Never use harsh chemicals, gasoline, detergents, chemically treated cloths, or other
cleansing solutions. These all could possibly hurt the cabinet.
Cleaning the Filters:
•
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the
filters. Rinse the filters under running water (no warmer than 104oF).
Thoroughly dry the filters before replacing it back into the unit.
Do not use the air conditioner without the filters.
•
•
End of Season Storage:
• Completely drain out any condensed
cord
water from the unit.
• Set the air conditioner on fan mode
(ventilation only) for a few hours to
dry the inside of the unit.
• Clean or change the filter.
• Unplug and wrap the power cord
around the cord wrap as sown (Fig.
21).
• Place the unit back in its original
carton and store it in a clean, dry
area.
FIG. 21
13
K0080-1-2
TROUBLESHOOTING
The air conditioner does not operate.
y
y
y
y
Is the air conditioner plugged in?
Is the power outlet functioning correctly?
Is the full water tank indicator light flashing?
Is the ambient room temperature lower than the
set temperature?
y
y
Is the filter dusty or dirty?
Is the air inlet or outlet blocked?
The unit does not produce adequate
cooling.
y
Is the unit placed in direct sunlight? If so, close
any curtains or move the unit to a more shaded
area.
y
y
y
y
y
y
Are too many windows or doors open?
Are there too many people in the room?
Are there additional heat sources in the room?
Is the filter dusty or dirty?
Is the air inlet or outlet blocked?
Is the ambient room temperature lower than the
set temperature?
The unit is noisy.
y
y
Is the machine positioned unevenly? Make sure
the air conditioner is placed on a level, solid
surface.
The compressor does not work.
Is the compressor’s overheat protection function
activated? If so, wait for the temperature to drop
and then turn on the unit again.
☆ Never try to repair or dismantle the unit yourself. Unauthorized repairs
can void your warranty and endanger the user.
14
K0080-1-2
TECHNICAL SPECIFICATIONS
Model Number:
AC-14000E
AC-14000H
Power/Ampere Consumption
for Cooling*
1420W / 12.8A
Power/Ampere Consumption
for Heating*
N/A
1420W / 12.8A
Air Volume (max. speed)
Voltage / Frequency
Compressor Type
Refrigerant Type
450m3/h
115V, 60Hz
Rotary
R-410A
Number of Fan Speeds
Timer
3
1~24 hours
Ø 5.6" X 59.1"
72.8 lbs
Exhaust Pipe Dimensions
Net Weight
Product Dimensions
17.7" x14.4" x 32.5"
Notes:
1. Heating function is only for model number AC-14000H.
2. The data marked with '*' may vary for technical reasons; for more accurate data, please refer
to the rating label found on the back of the unit.
3. Measuring condition for the above specifications:
Cooling – DB = 95° F , WB= 82.94°F
Heating – DB= 68° F , WB= 59°F
* D.B. = dry bulb temperature = room temperature
*W.B. = wet bulb temperature = relative humidity
15
|