Zephyr Fan AK2000 User Manual

5SEꢀ #ARE AND )NSTALLATION 'UIDE  
2EAD ALL )NSTRUCTIONS BEFORE )NSTALLING AND OPERATING THIS APPLIANCE  
)MPORTANT 3AFETY .OTICE  
-/$%,ꢀ AK2000,AK6000,AK9800  
2%!$ !.$ 3!6% 4(%3% ).3425#4)/.3  
:$51,1*  
72ꢀ5('8&(ꢀ7+(ꢀ5,6.ꢀ2)ꢀ),5(ꢀ25ꢀ(/(&75,&ꢀ6+2&.ꢁꢀ'2ꢀ127ꢀ86(ꢀ7+,6  
)$1ꢀ:,7+ꢀ$1<ꢀ62/,'ꢂ67$7(ꢀ&21752/ꢀ'(9,&(ꢃ  
:$51,1*  
72ꢀ5('8&(ꢀ7+(ꢀ5,6.ꢀ2)ꢀ),5(ꢀ(/(&75,&ꢀ6+2&.ꢁꢀ25ꢀ,1-85<ꢀ72  
3(56216ꢁꢀ2%6(59(ꢀ7+(ꢀ)2//2:,1*ꢄ  
Dꢃꢀꢀ8VHꢀWKLVꢀXQLWꢀRQO\ꢀLQꢀWKHꢀPDQQHUꢀLQWHQGHGꢀE\ꢀWKHꢀPDQXIDFWXUHUꢁꢀLIꢀ\RXꢀKDYHꢀTXHVWLRQVꢁ  
FRQWDFWꢀWKHꢀPDQXIDFWXUHUꢃ  
Eꢃꢀꢀ%HIRUHꢀVHUYLFLQJꢀRUꢀFOHDQLQJꢀXQLWꢁꢀVZLWFKꢀSRZHUꢀRIIꢀDWꢀVHUYLFHꢀSDQHOꢀDQGꢀORFNꢀSDQHO  
WRꢀSUHYHQWꢀSRZHUꢀIURPꢀEHLQJꢀVZLWFKHGꢀRQꢀDFFLGHQWDOO\ꢃꢀꢀ:KHQꢀWKHꢀVHUYLFHꢀGLVFRQQHFWLQJ  
PHDQVꢀFDQQRWꢀEHꢀORFNHGꢁꢀVHFXUHO\ꢀIDVWHQꢀDꢀSURPLQHQWꢀZDUQLQJꢀGHYLFHꢁꢀVXFKꢀDVꢀDꢀWDJꢁ  
WRꢀWKHꢀVHUYLFHꢀSDQHOꢃ  
&$87,21  
)RUꢀJHQHUDOꢀYHQWLODWLQJꢀXVHꢀRQO\ꢃꢀ'RꢀQRWꢀXVHꢀWRꢀH[KDXVWꢀKD]DUGRXVꢀRUꢀH[SORVLYHꢀPDWHULDOVꢀ  
DQGꢀYDSRUVꢃꢀꢀ7DNHꢀFDUHꢀZKHQꢀXVLQJꢀFOHDQLQJꢀDJHQWVꢀRUꢀGHWHUJHQWVꢃ  
6XLWDEOHꢀIRUꢀXVHꢀLQꢀKRXVHKROGꢀFRRNLQJꢀDUHDꢃ  
:$51,1*  
72ꢀ5('8&(ꢀ7+(ꢀ5,6.ꢀ2)ꢀ5$1*(ꢀ723ꢀ*5($6(ꢀ),5(ꢄ  
Dꢃꢀꢀ1HYHUꢀOHDYHꢀVXUIDFHꢀXQLWVꢀXQDWWHQGHGꢀDWꢀKLJKꢀVHWWLQJVꢃꢀꢀ%RLORYHUVꢀFDXVHꢀVPRNLQJ  
DQGꢀJUHDV\ꢀVSLOORYHUVꢀWKDWꢀPD\ꢀLJQLWHꢃꢀ+HDWꢀRLOVꢀVORZO\ꢀRQꢀORZꢀRUꢀPHGLXPꢀVHWWLQJVꢃ  
Eꢃꢀꢀ$OZD\VꢀWXUQꢀKRRGꢀ21ꢀZKHQꢀFRRNLQJꢀDWꢀKLJKꢀKHDWꢀRUꢀZKHQꢀIODPLQJꢀIRRGꢀ  
Fꢃꢀꢀ&OHDQꢀYHQWLODWLQJꢀIDQVꢀIUHTXHQWO\ꢃꢀꢀ*UHDVHꢀVKRXOGꢀQRWꢀEHꢀDOORZHGꢀWRꢀDFFXPXODWH  
RQꢀIDQꢀRUꢀILOWHUꢃ  
Gꢃꢀꢀ8VHꢀSURSHUꢀSDQꢀVL]Hꢃꢀꢀ$OZD\VꢀXVHꢀFRRNZDUHꢀDSSURSULDWHꢀIRUꢀWKHꢀVL]HꢀRIꢀWKHꢀVXUIDFH  
HOHPHQWꢃ  
Hꢃꢀ.HHSꢀIDQꢁꢀILOWHUVꢀDQGꢀJUHDVHꢀODGHQꢀVXUIDFHVꢀFOHDQꢃ  
Iꢃꢀꢀ8VHꢀKLJKꢀVHWWLQJꢀRQꢀKRRGꢀRQO\ꢀZKHQꢀQHFHVVDU\ꢃ  
Jꢃꢀꢀ'RQ¶WꢀOHDYHꢀKRRGꢀXQDWWHQGHGꢀZKHQꢀFRRNLQJꢃ  
Kꢃꢀꢀ$OZD\VꢀXVHꢀFRRNZDUHꢀDQGꢀXWHQVLOVꢀDSSURSULDWHꢀIRUꢀWKHꢀW\SHꢀRIꢀDQGꢀDPRXQWꢀRIꢀIRRGꢀ  
EHLQJꢀSUHSDUHGꢃ  
:$51,1*  
72ꢀ5('8&(ꢀ7+(ꢀ5,6.ꢀ2)ꢀ,1-85<ꢀ72ꢀ3(56216ꢀ,1ꢀ7+(ꢀ(9(17ꢀ2)ꢀ$ꢀ5$1*(ꢀ723  
),5(ꢁꢀ2%6(59(ꢀ7+(ꢀ)2//2:,1*ꢄ  
Dꢃꢀ  
6027+(5ꢀ)/$0(6ꢀZLWKꢀDꢀFORVHꢂILWWLQJꢀOLGꢁꢀFRRNLHꢀVKHHWꢁꢀRUꢀPHWDOꢀWUD\ꢁꢀWKHQꢀ  
WXUQꢀRIIꢀWKHꢀEXUQHUꢃꢀ%(ꢀ&$5()8/ꢀ72ꢀ35(9(17ꢀ%8516ꢃꢀ,IꢀWKHꢀIODPHVꢀGRꢀQRWꢀJRꢀRXWꢀ  
LPPHGLDWHO\ꢁꢀ(9$&8$7(ꢀ$1'ꢀ&$//ꢀ7+(ꢀ),5(ꢀ'(3$570(17ꢀ  
Eꢃꢀ  
Fꢃꢀ  
1(9(5ꢀ3,&.ꢀ83ꢀ$ꢀ)/$0,1*ꢀ3$1ꢀ±ꢀ<RXꢀPD\ꢀEHꢀEXUQHGꢃꢀ  
'2ꢀ127ꢀ86(ꢀ:$7(5ꢁꢀLQFOXGLQJꢀZHWꢀGLVKFORWKVꢀRUꢀWRZHOVꢀ±ꢀDꢀYLROHQWꢀVWHDPꢀ  
H[SORVLRQꢀZLOOꢀUHVXOWꢃ  
5HYꢄꢅꢆꢅꢇ  
ZZZꢃ]HSK\URQOLQHꢃFRP  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT OVERVIEW  
1
HURRICANE SERIES  
Model number: AK2000, 2036  
QuattroVent Air Curtain  
Dual “Thrust-Fore" Self Clean Blowers  
Digital Touch Pad Controls  
Clock, Timer, 3 stage Delay Shutoff.  
CYCLONE SERIES  
Model number: AK6000, 6036, 6042, 6048  
Dual “Thrust-Fore" Self Clean Blowers  
Independent Rocker Controls w/ High, Low  
speed  
3 Way convertible ducting option  
WHIRLWIND SERIES  
Model number: AK9800  
Dual Self Clean Blowers  
Independent Rocker Controls w/ High, Low  
speed  
Slim Line Design  
3
1
Overview  
1.  
QuattroVent Air Curtain  
(Hurricane only)  
Self Clean Blowers  
Controls  
2.  
3.  
4.  
5.  
6.  
4
Light  
2
Residue Cup  
Underside splash guard  
6
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROLS  
2
HURRICANE SERIES  
14  
13 12 11 10  
3
hr  
LO  
LO  
HI  
HI  
2
5
4
12:01  
1
DELAY  
min  
FAN-R ON-OFF  
FAN-L  
7
OFF  
6
8
9
Controls Overview  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
Set Time  
8.  
Right Blower: On-High-Low-Off  
Operations: On-Off  
Right Blower Low Speed Indicator  
Right Blower High Speed Indicator  
Left Blower Low Speed Indicator  
Left Blower High Speed Indicator  
Delay Off Indicator  
Digital Display  
9.  
Set Hours  
Set Minutes  
10.  
11.  
12.  
13.  
14.  
Set Timed Delay Shut Off  
Light On-Off  
Left Blower: On-High-Low-Off  
Setting Clock  
press:  
hr  
LO  
LO  
HI  
HI  
12:01  
12:01  
Press "clock".  
DELAY  
OFF  
min  
FAN-L FAN-R ON-OFF  
Hour Indicator will flash indicating clock  
setting function is ready.  
hr  
hr  
LO  
LO  
HI  
HI  
Press "hr" to set hours (from 1-12).  
Press "min" to set minutes (from 00-59).  
min  
DELAY  
OFF  
min  
FAN-L FAN-R ON-OFF  
Let clock flash for 7 seconds and your new  
time input will automatically be stored.  
Light On-Off  
press:  
Press "light" button once to turn light on.  
Press again to turn off.  
to turn light On/Off  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROLS  
3
Blower Controls  
You can simultaneously turn On the light and  
both blowers on Hi speed by simply pressing  
"On/Off" once.  
press:  
to turn light and both  
blowers on Hi  
ON-OFF  
FAN-R  
During this time, you can select blowers and  
speed as indicated by pressing the "Fan-L"  
and "Fan-R" button.  
or turn individual blowers  
On/Off and select Hi/Lo speed  
FAN-L  
press again to turn all  
operations Off  
Note:  
ON-OFF  
The third press on the "Fan-L" and "Fan-R"  
button will turn blower Off the selected side (as  
indicator light turns off).  
You can also turn individual blowers On/Off  
and select speed by simply pressing the  
desired "Fan-L" or "Fan-R" button.  
Press "On/Off" again and all operations will  
stop.  
Timed Delay Off  
While blowers are in operation, pressing  
press:  
"Delay Off" button once will set the unit to  
turn off in 3 minutes. Press again for the  
preset 5 minutes countdown and third  
press for 10 minutes.  
once- countdown in 3 minutes  
twice- in 5 minutes  
3rd time- in 10 minutes  
DELAY  
OFF  
Light will turn off when pressed  
and blowers will decelerate to  
Lo speed.  
Once a desired time is selected,  
countdown will start as the delay off  
indicator light flashes. All operation will  
cease as the countdown reaches zero.  
indicator:  
hr  
3
DELAY  
min  
OFF  
Note: At any time when the delay function  
is selected, the light will turn off  
automatically and all blower will decelerate  
to Lo speed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROLS  
4
Setting Timer (Alarm)  
Press "hr" and "min" button to set desired timer  
countdown.  
press:  
hr  
Once timer is set, countdown will start in 7  
seconds as delay indicator light flashes.  
hr  
min  
1:04  
DELAY  
OFF  
min  
When countdown reaches 0, 10 short beeps will  
sound.  
set "hr" & "min" for timer countdown  
alarm will sound at end of timer  
To cancel timer after setting, press "On/Off"  
button to terminate all operations and restart.  
Note: Timer function cannot be operated  
simultaneously with the "Delay Off" function.  
Nevertheless, setting the timer function will not  
effect any other operations.  
CYCLONE & WHIRLWIND  
Rocker Controls  
(1) Light On/Off  
(1) Light- turns light On/Off  
(2) Right Blower  
(Hi/Lo, Off)  
3
2
1
(2) (3) Blower Controls- Independently controls  
Right and Left blowers. Rock switch up (I) for  
Lo speed, (II) for Hi speed, and center (.) to  
turn off.  
(3) Left Blower  
(Hi/Lo, Off)  
L
R
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
5
Self Clean Feature  
All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The  
centrifugal blower system automatically liquefies grease accumulated in its internal housing.  
All systems are equipped with dishwasher safe grease containers for its self clean function.  
Grease and residue from cooking are often automatically liquefied and can accumulate in the  
containers from everyday use. Nevertheless, grease from cooking could also dry and  
adhered in its internal housing. Running the self clean function periodically will flush out the  
accumulated grease in the range hood’s internal housing.  
Cleaning Frequency  
Cleaning should be approximately once a month under normal use.  
Detergent  
Grease cutting detergent such as ‘409’ or its equivalent are recommended.  
Cleaning  
Safety Grill  
Remove both safety grills for cleaning by  
simply loosening Philips screws. Clean safety  
grills in dishwasher under normal wash cycle.  
WARNING: Use with extreme caution as both  
safety grills are removed. Beware of blowers  
catching on to hair, loose clothing, and fingers.  
NEVER leave children unattended.  
press:  
Self Clean  
Turn both blowers on Low speed for cleaning.  
twice- countdown in 5  
minutes  
DELAY  
OFF  
For Hurricane series, simply set Timed Delay  
Off to 5 minutes as indicated.  
indicator:  
hr  
5
DELAY  
OFF  
min  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
6
With nozzle on ‘spray’, squirt ‘409’ detergent  
directly onto blower blades 30-35 times.  
Repeat with second blower. Allow self  
cleaning to run for 5 minutes before switching  
off. (If desired, spray water to rinse off detergent after  
completion of the cleaning cycle and run for another few  
minutes)  
Remove residue containers by gently sliding  
out with both hands. Clean in dishwasher  
under normal wash cycle.  
Hurricane Series:  
Remove light shield by turning counter-  
clockwise.  
Clean in dishwasher under normal wash cycle.  
Whirlwind Series:  
Remove light shield by unscrewing Philips  
screw.  
Clean in dishwasher under normal wash cycle.  
Cleaning Tip:  
Fill residue containers ¼ full with water before cleaning or during regular use. This will  
help to prevent grease from drying and tacking on cup surface.  
Warning:  
Edges on stainless steel surface are exposed once shield is removed. Clean around  
edges with extreme care and we recommend the use of latex cleaning gloves.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
7
QuattroVent Channels  
The QuattroVent Air-Curtain channels are  
adjoined to its two main blowers and share the  
same internal housing. No further cleaning is  
required after the self clean is completed.  
Clean residue around the channels surface  
with ‘409’ and a cotton cloth regularly.  
Surface Maintenance  
Clean all surface residue with ‘409’ or mild detergent and wipe with a cotton cloth.  
Stainless steel surface could further be polished with any stainless steel polish or glass  
cleaners.  
Replacing Lights  
All light bulbs included are 40W appliance bulb. Replace with 60W bulbs if brighter  
illumination are desired. Remove light shield according to instructions on page 6.  
Warning: Edges on stainless steel surface are exposed once shield is removed. Replace  
bulb through opening with extreme care. We recommend wearing of latex gloves.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
8
WARNING  
Installation of this product is intended for qualified installers, service technicians, or  
persons with similar qualified background. DO NOT attempt to install this appliance  
yourself. Injury could result form installing the unit due to lack of appropriate electrical  
knowledge and technical background. Improper installation, adjustment, alteration,  
service or maintenance can cause injury or property damage and the warranty on the  
product automatically becomes void.  
Installation of this product must conform with all local codes. All connections must be  
electrically grounded and ducting must be properly vented outside in accordance to  
codes. Never duct exhaust into attics, within walls, crawlspaces, garages, or anywhere  
inside the house which might cause grease fire. All duct joints must be properly  
inspected, taped and sealed.  
Edges are exposed around the duct opening and once the bottom grease shield is  
removed. Be careful when handling the sharp edges. Wearing protective gloves and  
appropriate work clothing is recommended.  
REQUIREMENTS  
Duct Size  
Tools  
Hurricane- 6“ Vertical Duct Discharge  
Whirlwind- 6“ Vertical Duct Discharge  
Cyclone- 6“ Vertical Duct Discharge  
3-1/4 x 10“ Vertical Duct Discharge  
3-1/4 x 10“ Horizontal Rear  
Discharge  
Hand Drill with #2 philips  
Flat head screwdriver to pry electrical knockout  
3/4“ Wood Boring Bit  
Jigsaw (if cabinet opening modification is  
required)  
Power Source  
115W  
ACCESSORIES  
Hurricane & Whirlwind series  
2
2
residue cups  
1
3
1
1
1
6“ starting collar  
‘L’ brackets (for direct wall mount  
only)  
electrical wire connectors & screws  
Convertible transition collar  
6“ collar cap  
4
1
3
screws for ‘L’ brackets  
6“ starting collar  
electrical wire connectors & screws  
3-1/4 x 10“ starting collar (packaged  
separately)  
Back-splash  
1
Cyclone series  
2
2
residue cups  
Check all accessories before installation, packaging also  
includes 1) Care, Maintenance and installation manual  
2) Owner’s Warranty Registration Card 3) Serial number  
label adhered on top of box.  
‘L’ brackets (for direct wall mount  
only)  
4
screws for ‘L’ brackets  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
9
DUCT OPENING  
Wall  
2-1/2”  
4-1/2”  
Rear  
Front  
3-1/4 x 10”  
6”  
(A)  
Rear  
7”  
Front  
Wall  
Cut Out Size (A):  
Hurricane  
Cyclone  
Whirlwind  
10-1/2“  
10-1/2”  
8-1/2”  
CLEARANCES  
Minimum clearance above range should be no  
less than 18“ from the range surface to the  
range hood’s base. Maximum height are  
recommended not to exceed 30” for maximum  
efficiency.  
Net width on all models are call out width less  
1/4”.  
Call Out Size  
Net Width  
29-3/4”  
35-3/4”  
41-3/4”  
47-3/4”  
net width  
30“  
36“  
42“  
48“  
MIN. 18” MAX 30”  
Note: Refer Manufacturers’ height clearance  
requirements on all high btu and professional  
ranges.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
10  
STEP 1  
STEP 2  
1. Remove all contents from box  
2. Unscrew and remove bottom grease splash shield  
1. Locate electrical connection box inside  
2. Unscrew cover to reveal wiring  
STEP 3  
STEP 4  
1. Locate electrical connection box knock out from left  
rear of hood and pry open with screwdriver  
1. Cut out cabinet base opening if necessary. Refer  
cut out dimensions previous page.  
STEP 5  
STEP 6 (also refer notes on pg. 16)  
1. Reinforce cabinet base with 1x2 wood strips if  
additional strengthening is required.  
1. Install damper if required by local codes (not  
provided), or install 6“ starting collar (green)**  
2. Unscrew and remove bottom grease splash shield  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
11  
STEP 7  
STEP 8  
1. Lift hood to bottom of cabinet  
1. Support hood to place, fasten both rear with screws  
and washers provided.  
STEP 9 (also refer notes on pg. 16)  
STEP 10  
1. Fasten front of hood. Level all sides and adjust  
accordingly.**  
1. Drill out cabinet base through electrical box with  
3/4" boring bit.  
STEP 11  
STEP 12 (also refer notes pg. 16)  
1. Connect both wires (blk) on hood to either power  
supply (blk or wht). Ground green wire.**  
1. Pull electrical supply wire through drill out or use  
#14 grounded wire for receptacles (not supplied)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
12  
STEP 13  
STEP 14  
1. Reinstall electrical box cover.  
1. Reinstall bottom splash shield by first fastening 3  
rear screws, (do not tighten all the way).  
STEP 15  
STEP 16  
1. Next, fasten the 3 front screws and begin tightening  
all screws from rear to front.  
1. Connect duct to opening, inspect and tape all joints  
with approved aluminum or duct tape.  
STEP 17  
STEP 18  
1. Turn on electrical supply or plug into receptacles.  
1. On Cyclone & Whirlwind models, be sure to pull  
both grease tubes over its opening.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
13  
CONVERTIBLE OPTIONS  
Cyclone series: AK6000, 6036, 6042, 6048  
Zephyr’s Cyclone series are equipped with the option of a 6“ vertical discharge, 3-1/4x10” vertical discharge, or 3-  
1/4x10” rear discharge. Additional accessories are provided to convert to either of the above discharge methods.  
Convertible Options  
Vertical discharge  
Convertible Accessories  
6“ round duct cap  
Round to rectangular transition adaptor  
Rectangular to round transition adaptor (pre-  
mounted)  
Gasket (pre-mounted)  
Rectangular rear cap (pre-mounted)  
3-1/4 x 10“ starting collar  
6“ round  
3-1/4 x 10“  
3-1/4 x 10”  
Vertical discharge  
Horizontal rear discharge  
Back Splash  
Cyclone models also come with a standard back splash. If desired, install back splash to rear of range hood with  
screws provided after all duct conversion steps below are completed.  
3-1/4 x 10“ Vertical Discharge  
1. Remove pre-mounted 6“ transition adaptor on duct  
opening. Leave attached gasket in its original place.  
2. Place rectangular transition adaptor as shown over  
gasket and by first installing 4 screws on half round  
section.  
3. Mount the 3-1/4 x 10“ starting collar on top of  
transition piece with remaining screws.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
14  
3-1/4 x 10“ Rear Discharge  
4. At rear of range hood, remove all screws on pre-  
mounted rear rectangular cap and remove cap with  
gasket.  
5. Remove top pre-mounted transition piece. Leave  
attached gasket in its original place.  
6. Remove 2 arch blocks through top opening.  
7. Mount Starting Collar (provided) at rear discharge  
opening with gasket previously removed.  
Option 1: (for recessed cabinet base)  
Re-install originally pre-mounted round transition  
piece at opening with gasket.  
Cap opening with 6“ cap provided OR, use option 2 if  
cabinet base is not recessed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
15  
3-1/4 x 10“ Rear Discharge  
Option 2: (for flush cabinet base)  
Mount rectangular transition piece at opening with  
gasket as shown.  
Mount rectangular cap (previously removed) on top of  
transition adaptor.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
16  
INSTALLATION NOTES  
Step 6:  
A damper (not included) should be installed to prevent back-draft where needed. A damper might also be required  
local codes in order to qualify for building inspections. You can purchase dampers from most hardware stores, or call  
our service line to order.  
When a damper is not installed, a starting collar is provided in order to increase and raise the duct opening clearance  
above the cabinet's base. Snap the adaptor's smaller end to hood's duct opening and secure by drilling 2 pilot holes  
and fasten with screws (as shown on step 6, page 10).  
Step 9:  
The hood should NEVER be installed so that the front is  
tilting downward. This will cause grease to back flow to the  
front instead of the rear. ALWAYS level the hood or slightly  
tilt front of hood upward. Some models includes 2 pre-  
installed bumpers on the rear (or top) to aid the hood front  
tilt upward when installed. Remove the bumpers simply by  
peeling off if hood is preferred to be installed leveled. (refer  
diagram)  
Step 12:  
A connector locking the electrical wiring on the electrical box is recommended and might be required by local codes.  
Check with local inspectors, purchase and install the appropriate connector in order to meet all mandatory codes.  
Call our service line to order connector.  
Wall  
Rear  
Front  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE SHOOTING  
17  
1.  
Upon completion of installation,  
Check if unit has been plugged in, make sure that all power  
has been turned back on and all electrical wiring are  
properly connected.  
nothing works.  
2.  
3.  
Light is on but blowers are not  
turning at all or seems to be scraping on  
something.  
Blower blade unit might have been mounted too low and  
scraping the bottom or jammed. Loosen hex screw on  
bladeunitandadjusttoproper height.  
When blowers are on, something  
seems to be loose and spinning  
around inside.  
There might have been foreign particles left within the  
discharge opening or rocks, leaves, branches, etc. that  
might have fell in from old duct work. Disconnect duct work  
toinspectandremoveanyforeignparticles.  
4.  
5.  
Vibration when blowers are on  
Blowers noise  
Unit might not have been secured properly on cabinet. Or  
cabinetmightneedtobefurthersecuredintostudsonwall.  
Our blowers are designed to perform up to 695 cfm. A  
properly functioning motor itself should be relatively quiet.  
Nevertheless, due to vacuum created by the suction, noise  
level up to 5.5 sones will be generated when both blower  
unit is turned on at its maximum speed. Employ both  
blowers at maximum speed only when needed (heavy pan  
frying, wok cooking etc.) Employing low speeds or a single  
blower will suffice moderate cooking such as steaming,  
broilingetc.  
6.  
7.  
Light is not working  
Light bulb might need to be replaced. On some instances,  
the fragile bulb could have been damaged during the  
shipping process. Simply replace with a 40 or 60W  
appliancebulb.  
No grease is collected in the residue  
containers  
Grease flow will vary by the amount, methods and types of  
cooking. If pan-frying is frequent accompanied by  
steaming, vapor from steam will liquefy accumulated  
greaseinitsinternalhousingandflowsinthecontainers.  
No grease collected in the residue containers is normal  
until the self clean function is completed. Clean blowers  
approximately once a month as instructed to avoid  
clogging.  
8.  
No grease is collected in the residue  
containers after self cleaning.  
Tubes connected to the internal housing might have been  
clogged due to lack of cleaning. Or hood might not have  
been leveled when installed. Unclog tubes or re-install  
hood(referpage16).  
9.  
Safety grill are dirty  
The self clean feature cleans only the internal housing  
within the range hood. Remove safety grill to clean in  
dishwasherandcleanall surfaceperiodicallyasinstructed.  
Check duct size used, duct size should be at least 6“ or 3-  
1/4 x 10”. Range hood WILL NOT function properly with  
theinsufficientductsize.  
10.  
Blowers seemed weak  
Check if duct is clogged or if damper unit is not opening  
properly. A tight mesh on a side wall cap unit might also  
causerestrictiontotheair flow.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE SHOOTING  
18  
Use a damper type sidewall cap.  
Reduce the number of elbows and length of duct work.  
Check if all joints are properly connected, sealed and  
taped.  
11.  
Cooking fumes and smoke dissipates  
before it reaches the blower.  
Check if unit is installed at the recommended height  
(page 9). The range hood should also be able to cover  
the entire cooking area from left to right and most areas  
from rear to front.  
Open doors and windows might also distract air flow  
before it reaches the blowers.  
Make sure blowers are on high speed for heavy cooking.  
For other questions and further assistance please call our service department with  
the product’s registered serial number or write to:  
ZEPHYR CORPORATION  
Service Department  
1.888.880.VENT (8368) 415.282.1211  
1551 Minnesota St., San Francisco, CA 94107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TO OBTAIN SERVICE UNDER WARRANTY  
or any Service Related Questions, please call:  
1-888-880-8368  
Staple your receipt here.  
Proof of the original purchase  
date is needed to obtain service  
under the warranty.  
TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date.  
Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.  
One Year Service Repair Warranty:  
For one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or  
components due to manufacturing defects.  
Ten Years Parts Warranty:  
For ten years from date of original purchase, we will provide free of charge, nonconsumable replacement parts or  
components that failed due to manufacturing defects. Consumable parts not covered by this warranty include: Light Bulbs,  
Metal and Charcoal Filters.  
Who is Covered:  
This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48 mainland states,  
Hawaii and Washington D.C. In Canada and Alaska, this warranty is Limited.  
There might be costs associated with  
shipping the products to our designated service locations or you might need to pay service technician's travel costs, to have  
the appliance repaired in-home.  
This Warranty will be Voided when:  
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instruc-  
tions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with  
equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents.  
What is Not Covered:  
Consumable parts such as light bulbs, filters, and fuses. Services outside of service area and the labor cost incurred in  
connection with the removal, shipping and reinstallation cost, nor does it cover any other contingent expenses. The natural  
wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven  
cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Service trips to your  
home to teach you how to use the product. Damage of product caused by accident, fire, floods or act of God.  
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the original purchaser and  
does not extend to subsequent owners of this product. Any applicable implied waranties, including the warranty of  
merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original  
purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.  
Have your product proof of purchase with date ready for warranty issues.  
Or write to:  
Zephyr Corporation  
Service and Warranty Department  
395 Mendell Street  
San Francisco, CA 94124  
JAN07.0101  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weed Eater Tiller 168126 User Manual
Weed Eater Trimmer 545186764 User Manual
Western Digital Network Card Network hard drive User Manual
Westinghouse Flat Panel Television VR 3215 User Manual
Xtant Stereo Amplifier 3300x User Manual
Yamaha Microcassette Recorder MD8 User Manual
Zanussi Cooktop ZKF 661 LN User Manual
Zephyr Ventilation Hood ES1 30AW User Manual
Zephyr Ventilation Hood ESL M90AS User Manual
Zircon Stud Sensor Pro SL User Manual