Before installing, ensure that the following are available:  
Installation Requirements  
Before installing, ensure that the following are available:  
a) sufficient space to position the heater so there is 270 mm clear access  
under the heater (over-sink models) or 270mm above (under-sink).  
b) standard 10 amp 240 volt power outlet within 1500 mm of the heater  
c) cold water supply with a minimum working pressure of 50 kPa and a  
maximum working pressure of 750 kPa.  
If pressure may exceed 750 kPa, a pressure limiting valve must be installed.  
Under-sink models must be installed beneath approved vented mixer taps  
requiring a single mounting point on a sink, basin or tub.  
Water pressure under 100 kPa may be sufficient for over-sink heaters but may  
not operate under-sink mixer taps satisfactorily.  
Before installing, ensure that the following are available:  
Installation Procedure  
Step One - Tapware  
Over-sink models must be installed with an inlet valve to control the flow from  
the water supply to the heater. No valve is supplied with the heater. The water  
supply and valve should be connected after the fastening the heater to the wall.  
Over-sink models are supplied with a 300 mm swivel spout. An 300 mm to  
600 mm telescopic swivel spout (99032) is available as an optional extra.  
SOLO MIXER  
HERO MIXER  
Under-sink models must be installed with approved vented tapware. It is  
advisable to fit the tap to the sink before mounting the heater to the wall  
beneath the sink.  
Cold Water  
Cold Water  
Supply to Heater  
B
Supply from Tap  
A
1. Ensure that the flexible tubes are firmly attached to the base of the tap body.  
2. Flush water supply pipes thoroughly to remove any silt or fines.  
3. Fasten the tap body to the sink using the bolt & plate system provided.  
4. Connect red flexible tube (from tap base "C") to the heater outlet.  
Fixing Bolt  
C
Hot Water  
Supply from Heater  
5. Insert flow restrictor provided to the free end of blue flexible tube "A"  
ONLY IF the water pressure is likely to exceed 250 kPa. Otherwise discard  
restrictor.  
6. Connect blue flexible tube (from tap base "B" ) to the heater inlet.  
7. Connect blue flexible tube (from tap base "A") to the cold water supply.  
MONO MIXER  
Cold Water Supply to  
Heater  
B
Do not dismantle the assembled tap body during installation. Mixer taps are  
factory tested and sealed to provide optimum performance.  
Fixing Bolt  
To adjust water temperature delivered by Solo and Hero mixer taps, see  
instructions on page 7. Such adjustments should be made only by a qualified  
technician.  
C
A
Hot Water  
Supply from Heater  
Cold Water  
Supply from Tap  
Note: If replacing an existing open outlet (vented) water heater an isolation valve  
must be fitted to the incoming water supply and a 7L/min flow restrictor fitted  
at the isolation valve outlet. It is essential to establish that any existing tapware  
is vented.  
ZenithTudor -Installation&OperatingInstructions-81333 -July-2004  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Procedure continued  
Step Two - Positioning  
Over-sink heaters should be installed so that the outlet spout drains to a sink  
or basin, and with a clearance of 270 mm beneath the heater to allow for  
service access.  
Model  
Weight(kg)  
Empty  
Full  
Five Litre  
over-sink 3.5  
8.5  
Under-sink heaters should be installed a closely as possible to directly below  
the outlet tap with a clearance of 270 mm above the heater.  
Ten Litre  
under-sink 4.0  
14.0  
8.5  
Five Litre  
over-sink 3.5  
Step Three - Fastening  
It is not necessary to remove the case of the heater during installation.  
Ten Litre  
under-sink 4.0  
14.0  
The heater must be wall mounted with two fixing screws as shown in the  
diagram on page 5. Fixing screws must have the strength to support the filled  
heater.  
The fixing screws are to protrude 4 mm from the wall as shown in the diagram  
on page 5 so as to fit into keyhole slots provided on the rear of the heater.  
Step Four - Connecting  
On over-sink models, the inlet and outlet are located on the base of the heater.  
On under-sink models, the inlet and outlet are located on the top of the heater.  
All Zenith Tudor water connections are via 15 mm compression fittings and must  
be made strictly as shown in the diagrams.  
Over-sink models are supplied with a 300 mm open outlet spout, and must  
also be fitted with an isolation valve on the cold water side. A valve is not  
supplied with the heater and must be supplied and fitted by the installer.  
Under-sink models must be installed with approved vented tapware regulating  
the incoming water supply which displaces the hot water from the heater so it  
discharges through the open vented spout incorporated into the tap mounted  
on the basin or sink.  
The use of tapware other than approved vented tapware is dangerous.  
Each heater is equipped with a 1600 mm power cord and plug and should be  
connected to a standard 10 amp power outlet located adjacent to the heater.  
Do not turn the power ON until the heater is filled with water and air is purged  
from the heater.  
Step Five - Commissioning  
Fill the heater tank and purge air from the heater by turning the water supply  
ON and running water through the heater until it flows smoothly. Turn the water  
supply OFF and turn the power supply ON. The heater will then run through its  
heating cycle.  
During the heating cycle, drips fall from the delivery spout or tap.  
Dripping will cease when the heating cycle is completed and the stored water  
temperature has reached the level set by the user.  
Page 4  
ZenithTudor-Installation&OperatingInstructions- 81333- July-20043  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Procedure Continued  
Over-Sink  
Under-Sink  
Problem Solving  
Fault  
Possible cause  
Solution  
No heat  
No power  
Check power supply  
Contact Zenith  
Faulty element  
Faulty thermostat  
Faulty cutout  
Tripped overlaod  
No water  
No supply  
Check water supply  
Blockage  
Contact Zenith  
Faulty thermostat  
Faulty cut out  
No indicator  
Faulty LED  
Contact Zenith  
Faulty connection  
ZenithTudor-Installation&OperatingInstructions-81333-July-2004  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Procedures  
Water Temperature  
Zenith Tudor water heaters are fully automatic, and may be left switched ON  
under the control of the variable thermostat.  
Nominal operating temperature can be varied from about 30°C to about 80°C.  
Temperature should not be set to less than 60°C without due regard to  
regulations governing the storage temperature of hot water.  
Economy Setting  
The economy setting "E" will maintain stored water temperature at  
approximately 60°C. At the "E" setting, the temperature control locates into a  
set position and a slight resistance will be felt when rotating the temperature  
control beyond that setting. This measure is to help ensure that higher  
temperatures are only selected deliberately.  
LOW  
ECONOMY  
ANTI-  
FREEZE  
Frost Protection  
If the heater is located where ambient air temperature could fall below 5°C  
when the heater is not in use, the "anti freeze" setting on the temperature  
control will maintain stored water temperature over 5°C to prevent freezing  
and damage to the water heater.  
HIGH  
OFF  
The same protection does not extend to connecting pipework or fittings.  
Safety Cutout  
Should the heater over-heat, a manually resettable safety cutout will  
automatically turn the heating element OFF. The cutout must be reset by a Zenith  
Service Provider or a licensed electrician. Users should never reset the cutout  
without qualified assistance.  
Cleaning  
Never use strong, corrosive or abrasive cleaning materials. Wipe clean the  
outer surfaces with a sponge or soft cloth using a mild soap and water.  
Domestic dish washing liquid detergent is most suitable.  
Spare Parts  
PART NO DESCRIPTION  
Z90401  
Z90407  
Z90408  
Z90415  
Z90416  
Z90417  
Z90418  
Z90420  
Z90421  
Z90423  
element neck ring kit Tudor  
fascia kit Tudor undersink  
fascia kit Tudor oversink  
element kit Tudor 5ltr o/sink  
element kit Tudor 10ltr o/sink  
element kit Tudor 5ltr u/sink  
element kit Tudor 10ltr u/sink  
pilot light kit Tudor  
thermostat kit Tudor  
overload kit Tudor  
Page 6  
ZenithTudor-Installation&OperatingInstructions-81333-July0- 2004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
#
Service Procedures  
This appliance may only be serviced by a suitably qualified technician.  
Disconnect from power and turn water supply OFF before attempting any kind  
of service work.  
Removing the case  
1. Remove temperature control knob by gripping it and pulling towards you.  
2. Remove the single retaining screw located beneath the temperature control knob.  
3. Remove the four case screws two at top, two at bottom.  
4. The case can now be lifted off carefully.  
Replacing the case  
Reverse of the above procedure.  
Replacing a thermostat  
Knob removed to show screw  
1. Remove the front cover.  
2. Disconnect the two electrical terminals from the thermostat. These are  
spade connectors and can be easily pulled off.  
3. Remove the two screws attaching the thermostat to the plastic upright.  
4. Pull the capillary out of the thermostat pocket located on the element  
assembly.  
5. Take the new thermostat (Z90421) and uncoil about half of the capillary tube.  
6. Push the new capillary into the pocket ensuring that:  
a) if it is an over sink model, the cutout bulb goes in first then the  
thermostat bulb behind it.  
b) if it is a under sink model, then the reverse is applicable.  
Thermostat spade connectors  
Attach the thermostat to the plastic upright.  
Reconnect the two electrical terminals. It does not matter which way around  
the connections occur.  
Ensure the remaining capillary coil is out of the way of any live terminals.  
Ensure the plastic upright is located securely in the position provided.  
Refit the cover assembly.  
#
Tap Temperature Adjustment  
Adjustment of a tap temperature limiter on Solo and Hero vented taps  
should be made only by a Zenith Service Provider or a qualified  
technician.  
Top Ring “X”  
1. Remove tap handle assembly to expose the mixer cartridge.  
2. Lift and rotate the serrated top ring "X" from the mixer cartridge "Y".  
Rotating the ring left or right will regulate the water temperature.  
Rotating the ring clockwise will increase the water temperature.  
Rotating the ring anticlockwise will decrease water temperature.  
The tap normally operates with the ring in the central position.  
3. Reassemble the tap handle assembly to its original condition.  
4. Test the temperature of the water outlet to check acceptability.  
Mixer Cartridge “Y”  
ZenithTudor -Installation&OperatingInstructions -81333- July-2004  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
#
Warranty Information  
The Zenith appliance you have chosen is precision-built from the finest materials  
available and should give many years of trouble free service.  
Certain warranties may be implied by law into your contract with Zenith. The  
warranty provided below is additional to these implied warranties and nothing  
set out below shall limit your statutory rights or rights at law.  
Parex Appliances warrants that, should any part fail within 12 calendar  
months of installation, that part will be repaired or replaced free of charge by  
Parex Appliances or its Distributor or Service Provider, except as set out below,  
provided the appliance is installed and used strictly in accordance with the  
instructions supplied, and that failure is not due to accident, misuse, abuse,  
unsuitable water conditions, or to any alteration, modification or repair by any party  
not expressly nominated by Parex Appliances.  
No costs are payable by the customer other than any mileage or travelling-time  
charges incurred by a Zenith Service Provider or the cost of removal, cartage and  
re-installation of any component of the appliance if it needs to be returned for  
repair its Distributor.  
This warranty does not cover damage resulting from non-operation of the  
appliance or consequential damage to any other goods, furnishings or property.  
No warranty applies to the life of any filtration cartridge installed with the  
appliance as cartridge life may vary according to water quality and the rate of  
water consumption.  
Parex Appliances does not exclude, restrict or modify any liability that cannot be  
excluded, restricted or modified or which cannot, except to a limited extent, be  
excluded, restricted or modified as between the owner or user and Parex Appliances  
under the laws applicable.  
Furthermore, this warranty does not displace any statutory warranty, but, to the  
extent to which Parex Appliances is entitled to do so, the liability of Parex Appliances  
under any statutory warranty will be limited at Parex Appliances option to the  
replacement of the appliance or supply of equivalent appliance, the payment of the  
cost of replacing the appliance or acquiring an equivalent appliance, or the payment  
of the cost of having the appliance repaired or the repair of the appliance.  
Head Office  
Parex Appliances  
103 Central Park Dr  
Henderson Auckland  
Telephone (09) 836 6566  
Facsimile (09) 836 6033  
Zenith Tudor - Installation & Operating Instructions - 81438 - June 2004  
Page 8 of 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym WEBE09140 User Manual
Well Traveled Living Patio Heater 60697 User Manual
Weslo Treadmill WCTL293100 User Manual
Whirlpool Cooktop GJC3055RB00 User Manual
Whirlpool Washer AWE6517 User Manual
Wolf Appliance Company Ventilation Hood PI423418R User Manual
Yamaha Stereo Receiver CR 840 User Manual
Zanussi Clothes Dryer TD164 User Manual
Zanussi Refrigerator ZUD 9154 A User Manual
Zap Automobile D555,043 User Manual