GAS HOB
ZGF 681
INSTRUCTION BOOKLET
Please read this instruction booklet before using the appliance
AU
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
For the User
For the Installer
Important Safety Information
Description of the Hob
Operation
2
3
4
5
6
6
Instructions for the Installer
Important safety requirements
Electrical connections
7
7
8
Maintenance and Cleaning
Something Not Working?
Service and Spare Parts
Adaptation to different types of gas
Building in
8
10
Description of the Hob
3
2
Model ZGF 681 IX
3
1
4
5
3
Model ZGF 681 ICX
2
3
1
4
1. Hob Top
2. Auxiliary Burner
5
3. Semi-rapid Burners
4. Ultra-rapid Double-crown Burner
5. Control knobs
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Hob Burners
To light a burner:
F
l
push in the relevant control knob and turn it
anticlockwise to maximum position;
l
upon ignition, keep the knob pushed down about 5
seconds. This will allow the "thermocouple" (Fig. 1 -
letter D) to be heated and the safety device to be
switched off, otherwise the gas supply would be
interrupted;
l
then adjust the flame as required.
If the burner does not ignite, turn the control knob to
zero, and try again.
Fig. 1
To ensure maximum burner efficiency, you should only
use pots and pans with a flat bottom fitting the size of
the burner used (see table).
A - Burner cap
B - Burner crown
C - Ignition electrode
D - Thermocouple
Burner
minimum
diameter
maximum
diameter
Large(double-crown)
Medium(semi-rapid)
Small (Auxiliary)
180 mm.
120 mm.
80 mm.
260 mm.
220 mm.
160 mm.
If you use a saucepan which is smaller than the
recommended size, the flame will spread beyond
the bottom of the vessel, causing the handle to
overheat.
As soon as a liquid starts boiling, turn down the
flame so that it will barely keep the liquid
simmering.
Take care when frying food in hot oil or fat, as
the overheated splashes could easily ignite.
If the control knobs become difficult to turn, please
contact your local Service Centre.
Using the Wok Stand
A wok stand is provided to enable you to use a round
bottomed wok on the hob. The wok stand must only be
used on the double crown burner, and should not be used
with any other type of wok or pan.
When fitting the wok stand, ensure the recesses in the
frame fit securely onto the bars of the pan supports, as
shown in the diagram.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Cleaning
Before any maintenance or cleaning can be carried
out, you must DISCONNECT the hob from the
electricity supply.
The hob is best cleaned whilst it is still warm, as spillage
can be removed more easily than if it is left to cool.
The Hob Top
Regularly wipe over the hob top using a soft cloth well
wrung out in warm water to which a little washing up
liquid has been added.Avoid the use of the following:
- household detergent and bleaches;
- impregnated pads unsuitable for non-stick saucepans;
- steel wool pads;
- bath/sink stain removers.
Should the hob top become heavily soiled, it is
recommended that a cleaning product such as Hob Brite
or Bar Keepers Friend is used.
FO 2237
Pan Supports
To keep the pan supports in the correct position, they
are hooked into hinges at the back of the hob.
Fig. 2
Model ZGF 681 IX: The pan supports can be lifted
for easier cleaning, as shown in Fig. 2.
Model ZGF 681 ICX: The hob has two cast iron
pan supports.
YES
Take care when removing them. They are
heavy and could damage the hob or your
kitchen furniture if you let them fall.
Never turn the pan supports on the hinges, this
could damage them.
To remove the pan supports completely, proceed
as shown in Fig. 3.
Wash the pan supports using hot soapy water. If
necessary, a paste cleaner or a soap impregnated steel
wool pad can be used with caution.
NO
After cleaning, be sure to wipe dry with a soft cloth.
The Burners
The burner caps and crowns (Fig. 1) can be removed for
cleaning.
Wash the burner caps and crowns using hot soapy water,
and remove marks with a mild paste cleaner. A well
moistened soap impregnated steel wool pad can be used
with caution, if the marks are particularly difficult to
remove. After cleaning, be sure to wipe dry with a soft
cloth.
Fig. 3
Ignition candle
The electric ignition is obtained through a ceramic
"candle" and a metal electrode (Fig. 1 - letter C). Keep
these components well clean, to avoid difficult lighting,
and check that the burner crown holes are not
obstructed.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Something Not Working?
If the hob is not working correctly, please carry out the following checks before contacting your local Service Force
Centre.
SYMPTOM
SOLUTION
n There is no spark when lighting the gas
u Check that the unit is plugged in and the electrical
supply is switched on
u Check that the RCCB has not tripped (if fitted)
u Check the mains fuse has not blown
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
n The gas ring burns unevenly
u Check the main jet is not blocked and the burner
crown is clear of food particles.
u Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Service and Spare Parts
In the event of your appliance requiring service, or if you
wish to purchase spare parts, please contact your
Service Centre.
For your nearest Authorised Service Centre please
contact:
Electric Blue Service & Installation P/L
324 Frankston Dandenong Rd,
Dandenong. VIC 3175
Phone: 1300 654 488
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Instructions for the Installer
SUPPLY CONNECTIONS
Engineers technical data
Gas:
OVERALL DIMENSIONS
RC 1/2 inch (1/2 inch male) Rear right hand corner
Width:
Depth:
580 mm.
510 mm.
Electric:
230-240V 50Hz supply
CUT OUT DIMENSIONS
APPLIANCE GAS SUPPLY:
Width:
Depth:
560 mm.
480 mm.
Natural gas 1.0 kPa - Universal LPG 2.75 kPa
TYPE
TYPE
NOZZLE
MARKS
1/100 mm CONSUMPTION
MJ/h
NOMINAL
GAS
NOMINAL
PRESSURE
kPa
OF BURNER
OF GAS
Burner
Dia. Tap By-pass
1/100 mm
Double Crown (wok)
Semi-rapid (medium)
1.67
1.11
0.89
13.00
6.80
3.80
NATURAL
GAS
1.00
2.75
Auxiliary (small)
Auxiliary
Semi-rapid
Double crown
28
35
42
Double Crown (wok)
Semi-rapid (medium)
Auxiliary (small)
1.02
0.71
0.55
13.00
6.30
3.60
U-LPG
Aeration adjustment none
Important safety requirements
FITTING THE GAS HOB
WITHOUTACOOKERHOODABOVE
Location
Choose a location free of draughts and open doors and
clear of combustible materials or other fire hazards such
as curtains, etc. The location should ensure convenience
of operation and service. Any adjacent wall surface
situated within 200mm from the edge of any hob burner
and above the height of the hob must be a suitable non-
combustible material for a height of 150 mm for the entire
depth and width of the cooker.
700 mm
400 mm
50 mm
55 mm
400 mm
100 mm
50 mm
Any combustible material above the hotplate must be at
least 650 mm above the top of the hob and no
construction shall be within 450 mm above the top of the
burner.
FO 0812
FITTING THE GAS HOB
A minimum distance of 100 mm. must be left between
the side edges of the hob and any adjacent cabinets or
walls.
WITHACOOKERHOODABOVE
600 mm
650 mm
400 mm
55 mm
50 mm
400 mm
100 mm
50 mm
FO 0813
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical connections
The appliance is designed to be connected to 230-240 V
monophase electricity supply.
The connection must be carried out in compliance with
the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load (see the rating label);
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the forniture unit.
The appliance is supplied with a connection cable provided
with a plug, able to support the load marked on the
identification plate. The plug has to be fitted in a proper
socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts
and of a type suitable for the required load in compliance
with the current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 50 °C higher
than the room temperature.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.
Adaptation to different types of gas
WARNING: Servicing shall only be carried out
by authorised personnel.
Substitution of the nozzles
-
Remove all pan supports, burner caps, rings and
crowns;
-
With a tubular spanner no. 7 unscrew and remove
(see diagram) the nozzles substituting them with those
corresponding to the type of gas used (see Technical
data);
-
Remount the parts carrying out the operations
described in reverse. Upon completion remove
existing gas type label and stick the relevant gas type
label near the gas supply pipe.
If the pressure of gas used is different (or variable) from
that foreseen an appropriate pressure regulator should
be installed on the entry tube. In case pressure regulators
for U-LPG are used these should conform to the
regulations in force.
FO 0392
Regulation of the minimum
To regulate the minimum:
-
-
-
bring the tap to the minimum flame position.
extract the knob.
in case of conversion from natural gas to U-LPG, tightly
screw the by-pass screw (see diagram);
when converting from U-LPG to natural gas unscrew
about ½ turn by-passscrew,until a regular small flame
is reached.
-
By pass screw
Finally check that by quickly turning the tap from the
maximum position to the minimum position the burner
is not extinguished; remount the parts carrying out
the operations described in reverse.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Important
Important
Upon completion of installation, always check:
l that all the joints are completely sealed by using a
soapy solution, never a flame;
l that the gas pressure has been regulated to 1.00kPa
for Natural Gas and 2.75kPa for Universal-LPG. The
pressure test point is located on the regulator for
Natural Gas models or at the top left hand rear of the
cooker for U-LPG models. The pressure should be
measured and adjusted with the Wok burner on high
flame;
This cooker must be installed by qualified personnel.
The manufacturer will not accept liability, should the above
instructions or any of the other safety instructions
incorporated in this book be ignored.
Regulations
This appliance shall be installed in accordance with the
manufacturers installation instructions, local gas fitting
regulations, municipal building codes, AS5601 (AG601)
and any other relevant statutory regulations.
l that the automatic ignition system is operating
satisfactory on all burners, both individually and in
combination;
Data label
The data label is located centrally on the back frame of
the appliance. This appliance is suitable for Natural or
Universal LPG. Ensure that the gas supply matches the
data label. Aduplicate of the data label is supplied in the
packaging of the user manual and must be attached to
readily accessible adjacent surfaces of the appliance.
l that the burners operate correctly, are stable, without
yellow tipping or excessive noise on high and low
flame.
Then demonstrate to the customer the appliance
operation and leave these instructions.
Connection to the gas supply
Gas connection must be carried out in conformity with
the regulations in force. The appliance leaves the factory
tested and regulated for the type of gas indicated on the
plate which is situated in the lower position near the gas
connection tube. Ascertain that the type of gas with
which the appliance will be supplied is the same as that
indicated on the plate.
If different carry out all the operations according to the
indications cited in the paragraph adaption to different
types of gas.
For a maximum output and minimum consumption
ascertain that the pressure of the gas used has the values
indicated in the table of burner characteristics.
FO 0264
A) End of shaft with nut
B) Washer
The joint is mounted on the intake area of the pipe, fitted
with a filleted nut G 1/2, between the sealing components.
Screw the parts without forcing, turn the joint in the
direction required and then tighten everything.
C) Elbow
Connection
Carry out the connection to the gas plant only by means
of a rigid metallic pipe conforming to the regulations
in force.
The joint for the entry of gas into the appliance is threaded
R 1/2 tapered.
Carry out the connection avoiding any type of stress on
the appliance.
Natural gas appliances must be fitted with a pressure
regulator and be installed at the inlet connection. The
gas pressure must then be set as a part of the
commissioning procedures.
For U-LPG the pressure adjustment is made via the
regulator fitted at the domestic cylinder.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Building In
Rectangular cut-out size for hob
55 min.
580
480
510
560
Fig. 4
150 min
100
FO 2038
Dimensions are given in mm.
Fig. 5
These hobs can be inserted in a built-in kitchen unit whose
depth is between 550 and 600 mm. The hobs dimensions
are shown in Fig. 4.
Cut Out Size
The dimensions of the cut-out are given in the diagram.
FO 2348
Fitting the Hob into the worktop
Fig. 6
Carry out the building in of the hob as follows:
F
put the seals supplied with the hob on the edges of
the cut out, as shown in the diagram, taking care
that the seals meet without overlapping;
place the hob in the cut out, taking care that it is
centred;
fix the hob with the relevant fixing clamps and screws,
as shown in the diagram. When the screws have been
tightened, the excess seal can be removed.
Seal
The edge of the hob forms a double seal which prevents
the ingress of liquids.
FO 0199
Fig. 7
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Possibilities for
insertion
Fig. 9
Fig. 8
480
Kitchen unit with door
Proper arrangements must be taken in
designing the forniture unit, in order to avoid
any contact with the bottom of the hob which
can be heated when it is operated. The
recommended solution is shown in Fig. 8.
The panel fitted under the hob should be
easily removable to allow an easy access if
a technical assistance intervention is needed.
a
60
b
380
140
Kitchen unit with oven
The hob recess dimensions must comply the
indication given in Figs. 9 and 12 and must
be provided with brackets to allow a
continuous supply of air.
To avoid overhating, the building in should be
carried out as shown in Figs. 10 e 11.
The hob's electric connection and the oven's
one must be carried out separately, both for
safety reasons and to allow the oven to be
easily taken off the unit.
FO 2044
FO 2043
a) Removable panel
b) Space possibly useful for
connections
Fig. 11
Fig. 10
Hanging forniture units or hoods must be
placed at 650 mm. minimum from the hob
(Fig. 13).
50 cm2
120 cm2
360 cm2
180 cm2
FO 2041
FO 2042
Fig. 12
Fig. 13
550 min.
FO 2350
FO 0198
11
Download from Www.Somanuals.com. All Manuals Search And Download.
From the Electrolux Group. The worlds No.1 choice.
The Electrolux Group is the worlds largest producer of powered appliances for kitchen, cleaning and outdoor use. More than
55 million Electrolux Group products (such as refrigerators, cookers, washing machines, vacuum cleaners, chain saws and
lawn mowers) are sold each year to a value of approx. USD 14 billion in more than 150 countries around the world.
35677-7401
10/02
Download from Www.Somanuals.com. All Manuals Search And Download.
|