DIGITAL IO BOX
Owner’s Manual
V516420 R2 1 IP 20
E
100 CR Printed in Japan
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Precautions
• Do not place a container with liquid or small metal
objects on top of this unit. Liquid or metal objects
inside this unit are a fire and electrical shock hazard.
• For normal ventilation during use, remove the rear of
the rack or open a ventilation hole.
• If the airflow is not adequate, the unit will heat up
inside and may cause a fire.
• Do not allow water to enter this unit or allow the unit
to become wet. Fire or electrical shock may result.
• This unit has ventilation holes at the top and bottom
to prevent the internal temperature rising too high.
Do not block them. Blocked ventilation holes are a fire
hazard.
• Connect this unit’s power cord only to an AC outlet of
the type stated in this Owner’s Manual or as marked
on the unit. Failure to do so is a fire and electrical
shock hazard.
• Hold the power cord plug when disconnecting it from
an AC outlet. Never pull the cord. A damaged power
cord is a potential fire and electrical shock hazard.
• Be sure to connect to an appropriate outlet with a pro-
tective grounding connection. Improper grounding
can result in electrical shock.
• Do not touch the power plug with wet hands. Doing
so is a potential electrical shock hazard.
• Do not scratch, bend, twist, pull, or heat the power
cord. A damaged power cord is a fire and electrical
shock hazard.
• The digital circuits of this unit may induce a slight
noise into nearby radios and TVs. If noise occurs,
relocate the affected equipment.
• Do not place heavy objects, including this unit, on top
of the power cord. A damaged power cord is a fire and
electrical shock hazard. In particular, be careful not to
place heavy objects on a power cord covered by a car-
pet.
Rack Mounting Caution
If the unit is rack mounted and transported regularly,
for example, when on a tour, we recommend that the
rear of the unit be supported by fitting a pair metal
brackets, one each side. The following drawing pro-
vides the information necessary to make such brack-
ets.
Note that only one bracket is shown here and the
bracket for the other side must be bent in the opposite
direction.
• If you notice any abnormality, such as smoke, odor, or
noise, or if a foreign object or liquid gets inside the
unit, turn it off immediately. Remove the power cord
from the AC outlet. Consult your dealer for repair.
Using the unit in this condition is a fire and electrical
shock hazard.
• Should this unit/AC adapter/power supply be
dropped or the cabinet be damaged, turn the power
switch off, remove the power plug from the AC outlet,
and contact your dealer. If you continue using the unit
without heeding this instruction, fire or electrical
shock may result.
2-R2
2-R2
(82.1)
76.2
• If the power cord is damaged (i.e., cut or a bare wire is
exposed), ask your dealer for a replacement. Using the
unit with a damaged power cord is a fire and electrical
shock hazard.
44.45
31.75
R5
• Do not remove the unit’s cover. You could receive an
electrical shock. If you think internal inspection,
maintenance, or repair is necessary, contact your
dealer.
0
5.9
ø
4- 6.5
R2
t = 1.6
• Do not modify the unit. Doing so is a fire and electri-
cal shock hazard.
• When setting up the product, make sure that the AC
outlet you are using is easily accessible. If some trou-
ble or malfunction occurs, immediately turn off the
power switch and disconnect the plug from the outlet.
Even when the power switch is turned off, electricity is
still flowing to the product at the minimum level.
When you are not using the product for a long time,
make sure to unplug the power cord from the wall AC
outlet.
• When rack-mounting the unit, allow enough free
space around the unit for normal ventilation. This
should be: 10 cm at the sides, 15 cm behind, and 30
cm above.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Thank you for choosing the DIO8 digital IO box, specifically designed
for the Yamaha PM1D digital audio mixing system.
The DIO8 outputs and inputs digital signals (such as ADAT, TASCAM, and AES/EBU) as well as analog
signals to and from the DSP1D/DSP1D-EX engine controlled via the CS1D control surface. Up to eight
digital I/O cards and analog I/O cards can be installed on each DIO8.
Front panel
I/O UNIT ID
1
PORT B SELECTOR
5-8
2
1-4
I/O UNIT ID
PORT
B
SELECTOR
5-8
1-4
POWER
ON/ OFF
POWER
ON/ OFF
3
DIGITAL IO BOX
Rear panel
IN
4
OFF
75Ω
ON
WORD
CLOCK
8
7
6
5
4
3
2
1
IN
COM
OFF
ON
75Ω
WORD
CLOCK
OUT
OUT
5
COM
OUTPUT
INPUT
B
(1–4/5–8)
A
(1–4/1–8)
B
(1–4/5–8)
A
(1–4/1–8)
6
The illustration shows the unit
without any cards installed.
*
OUTPUT
INPUT
B (1–4/5–8)
A (1–4)/(1–8)
B (1–4/5–8)
A (1–4)/(1–8)
7
8
4
Download from Www.Somanuals.com. All Manuals Search And Download.
If the PORT B SELECTOR is set to 5-8, slots 1-4 are
assigned to PORT A and slots 5-8 are assigned to
PORT B for input and output signals.
AI/O UNIT ID indicator
This indicates the connector number (the number of
the connector used to control the DIO8) of the engine
DSP unit (DSP1D/DSP1D-EX) connected to the DIO8.
If more than one connector is connected, either A or B
will be automatically selected as the connector for
control, according to the connection status of the
INPUT and OUTPUT jacks.
If there is a problem such as an incorrectly connected
DSP unit or if the word clock is not locked, this will be
indicated by one of the following error displays.
If the PORT B SELECTOR is set to 1-4, only PORT B
is available for input and output signals via slots 1-4.
In reality, slot 1-4 input signals are routed to OUT-
PUT A, and the INPUT B signal is output to slots 5-8.
If you wish to route slot 1-4 signals to both OUTPUT
A and B, use this setting.
PORT B SELECTOR issetto “5-8”
Slot1
Slot2
Slot3
Slot4
Error displays
E1: The OUTPUT connector of the DIO8 is connected
to the OUTPUT connector of the DSP unit. Please
connect it to the INPUT connector.
Slot5
Slot6
Slot7
Slot8
E2: The INPUT connector of the DIO8 is connected to
the INPUT connector of the DSP unit. Please con-
nect it to the OUTPUT connector. (This will not be
displayed if the OUTPUT connector of the DIO8 is
connected.)
PORT B SELECTOR issetto “1-4”
E3: Either the cable connected to the INPUT or OUT-
PUT connector has become disconnected, or the
connection destination is incorrect. If the connec-
tion is correct, try replacing the cable. (This will be
displayed only if both INPUT and OUTPUT are
abnormal.)
Slot1
Slot2
Slot3
Slot4
To connect the DIO8 to the DSP1D/DSP1D-EX, make
one of the following settings, depending on your
application.
UC: Control signals are not being received correctly.
Make sure that the power of the DSP unit is on.
These error displays indicate an error for the INPUT/
OUTPUT A connectors if the PORT B SELECTOR
switch is set to 5-8, and indicate an error for the
INPUT/OUTPUT B connectors if the PORT B SELEC-
TOR switch is set to 1-4. Even if there is an incorrectly
connected connector, the error display will not appear
if there is another control connector that is usable.
Using slots 1-8 of the DIO8 with a single
DSP1D/DSP1D-EX
1) Connect the INPUT A and B connectors of the DIO8 to
OUTPUT slot 1-6 of the DSP1D/DSP1D-EX.
2) Connect the OUTPUT A and B connectors of the DIO8
to INPUT slot 1-10 of the DSP1D/DSP1D-EX.
UL: The word clock is not locked. Make sure that the
word clock source is selected correctly, and that
the cable is connected correctly.
3) Set the PORT B SELECTOR to 5-8.
Using slots 1-4 of the DIO8 with two DSP1D/
DSP1D-EXs for Mirror mode operation
Note:
1) Connect the INPUT A connector of the DIO8 to the
OUTPUT slot 1-6 connector of the first DSP1D/
DSP1D-EX.
You can change the PORT B SELECTOR setting by
sending the control signal from the CS1D. At this
time, two dots (“. .”) light up besides the indicator
message described above.
If the PORT B SELECTOR switch setting on the
unit is different from the actual operation, one of
the following messages and the indicator message
described above will appear alternately.
2) Connect the INPUT B connector of the DIO8 to the
second DSP1D/DSP1D-EX OUTPUT slot connector
with the same number as the first unit’s slot you con-
nected in Step 1).
3) Connect the OUTPUT A connector of the DIO8 to the
INPUT connector for INPUT slot 1-10 of the first
DSP1D/DSP1D-EX.
• If the PORT B SELECTOR switches to slots 1-4:
“
”
4) Connect the INPUT B connector to the second
DSP1D/DSP1D-EX OUTPUT slot connector with the
same number as the first unit’s slot you connected in
Step 3).
• If the PORT B SELECTOR switches to slots 5-8:
“
”
BPORT B SELECTOR switch
5) When you place the unit into Mirror mode from the
CS1D, the PORT B SELECTOR changes its setting,
depending on the operating status.
Use this switch to select slots 1-4 or slots 5-8 to assign
the INPUT A/OUTPUT A connectors (referred to as
PORT A) and the INPUT B/OUTPUT B connectors
(referred to as PORT B).
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using slots 1-4 input signals with two DSP1D/
Caution:
DSP1D-EXs simultaneously
If you are using the MY8-AT card to handle ADAT
format signals, synchronization may tend to be
lost easily depending on the device that is con-
nected. For the most reliable synchronization, we
recommend that the word clock for digital audio
devices being used together be taken from a con-
nector other than the ADAT-format connector,
such as this connector.
1) Connect the INPUT A connector of the DIO8 to OUT-
PUT slot 1-6 of the first DSP1D/DSP1D-EX.
2) Connect the INPUT B connector of the DIO8 to the
second DSP1D/DSP1D-EX OUTPUT slot connector
with the same ID number as the first unit’s slot you
connected in Step 1).
3) Connect the OUTPUT A connector of the DIO8 to the
INPUT connector for INPUT slot 1-10 of the first
DSP1D/DSP1D-EX.
FCOM port
4) Connect the INPUT B connector to the second
DSP1D/DSP1D-EX OUTPUT slot connector.
This connector is provided for future system expan-
sion, but it is not operative in the current software
version.
5) Set the PORT B SELECTOR to 1-4.
Slot 1-4 input signals will be output from OUTPUT A
and B. However, the output signal will be the same as
the signal input to INPUT B.
GOUTPUT connectors A (1-4)/(1-8), B (1-4/
5-8)
These connectors are used to output multi-channel
digital audio signals to the DSP1D/DSP1D-EX.
Depending on the setting of the PORT B SELECTOR,
assignment between the OUTPUT A and B connec-
tors and slots 1-8 varies. For more information, refer
to 2PORT B SELECTOR. Be sure to use the included
genuine Yamaha half-pitch 68-pin cable for connec-
tion. Optional genuine Yamaha cables in a variety of
lengths are also available.
CPOWER ON/OFF switch
Use this switch to turn the power to the DIO8 on and
off. When the power is turned on, the I/O UNIT ID
indicator lights up.
DWORD CLOCK IN jack, ON/OFF switch
The WORD CLOCK IN jack is used to provide word
clock to the DIO8 from a clock generator or a con-
nected external device. Use a BNC cable with an
impedance of 75 Ω for connection.
HINPUT connectors A (1-4)/(1-8), B (1-4/5-8)
These connectors are used to input multi-channel dig-
ital audio signals from the DSP1D/DSP1D-EX.
Depending on the setting of the PORT B SELECTOR,
assignment between the INPUT A and B connectors
and slots 1-8 varies. For more information, refer to 2
PORT B SELECTOR. Be sure to use the included gen-
uine Yamaha half-pitch 68-pin cable for connection.
Optional genuine Yamaha cables in a variety of
lengths are also available.
The WORD CLOCK ON/OFF switch is used to termi-
nate the word clock connection. Basically, if the DIO8
is the last device of the word clock chain, or if nothing
is connected to the WORD CLOCK IN/OUT jacks, set
this switch to ON.
EWORD CLOCK OUT jacks
The WORD CLOCK OUT jacks are used to provide
word clock from the DIO8 to the connected external
device, such as digital MTR or DAT recorder. Use a
BNC cable with an impedance of 75 Ω for connection.
Note:
The “(1-8)” function labelled at the INPUT A/
OUTPUT A connectors is provided for future sys-
tem expansion, but it is not operative in the cur-
rent software version.
The following table shows optional Yamaha digital I/O cards and analog I/O cards that can be installed into the slots of dig-
ital IO unit DIO8.
It is not possible to install and use a total of five or more
Card
MY8-TD
Format
TASCAM
Input
8 IN
Output
8 OUT
8 OUT
8 OUT
—
AP8AD/AP8DA cards. Also, if you are using AP8AD/
AP8DA cards simultaneously with MY8-AD/MY4-AD/
MY4-DA cards, there are restrictions on the number of
cards, as described on the next page. Never exceed the
allowable number of cards, since attempting to use a
greater number of cards than allowed may damage the
DIO8 due to excessive current. If you are not using
AP8AD or AP8DA cards, or if you are using AP8AD or
AP8DA cards simultaneously with an MY8-TD/MY8-AT/
MY8-AE card, there is no limitation on the number of
MY8-TD/MY8-AT/MY8-AE cards that can be used.
MY8-AT
MY8-AE
MY8-AD
MY4-AD
MY4-DA
AP8AD*
AP8DA*
ADAT
8 IN
8 IN
8 IN
4 IN
—
AES/EBU
ANALOG IN
ANALOG IN
ANALOG OUT
ANALOG IN
ANALOG OUT
—
4 OUT
—
8 IN
—
8 OUT
*: Manufactured by Apogee Corporation
6
Download from Www.Somanuals.com. All Manuals Search And Download.
[MY8-AD]+[MY4-AD]+
[MY4-DA] cards used
[AP8AD]+[AP8DA] cards used
[MY8-TD]+[MY8-AT]+[MY8-AE] cards used
Total 0 cards
Up to a total of 8 cards
Total 1 card
Up to 6 cards
Up to 4 cards
Up to 2 cards
Up to 1 card
—
Up to the number of vacant DIO8 slots
Up to the number of vacant DIO8 slots
Up to the number of vacant DIO8 slots
Up to the number of vacant DIO8 slots
—
Total 2 cards
Total 3 cards
Total 4 card
Total 5 or more cards cannot be used
Installing an optional I/O card
Important!
Before installing an optional I/O card, be sure to turn off the power to the DIO8 and remove the power cord from the
DIO8. Otherwise, you may be in danger of electrical shock, and/or the unit or the card may be damaged.
1. Turn off the power to the DIO8 and remove the power
cord from the DIO8.
3. Align the edge of the card with the guide rail inside the
slot as shown below and insert the card into the slot.
Push in the card until the connector on the card is
securely plugged into the terminal inside the DIO8.
2. Loosen two screws as shown below and remove the
slot cover.
Keep the cover in a safe place for future use.
1
1
2
2
Guide rail
)
8
–
/1
4
–
(1
A
4. Fix the card by tightening the two screws.
Caution:
Be sure to tighten the screws securely. Otherwise,
the card may not be appropriately grounded.
5. Connect the power cord to the DIO8 and turn the
power on.
Specifications
Sampling frequency (external sync)
39.69 kHz – 50.88 kHz
USA and Canada : 120 V, 60 Hz
Power supply
Others : 230 V, 50 Hz
Power consumption
Dimensions (W × H × D)
Weight
70W
480 mm × 185.5 mm × 411.6 mm
15.5 kg
Operating temperature
Power cord length
Accessories
10 – 35˚C
1.5 m
Connection cable (68-pin, D-sub, half-pitch) x 2, Length: 3m
7
Download from Www.Somanuals.com. All Manuals Search And Download.
I/Os
I/O connectors
Level
Type
INPUT A, B
RS422
RS422
RS232C
D-sub, half-pitch, 68-pin connector (female)
D-sub, half-pitch, 68-pin connector (female)
D-sub,9-pin connector (male)
BNC connector
OUTPUT A, B
COM
*1
WORD CLOCK IN
WORD CLOCK OUT (X4)
TTL/75 Ω (ON/OFF)
TTL/75 Ω
BNC connector
*1 On the rear panel
Slots
Eight slots (slots 1-8) are available on the DIO8 for installing digital I/O cards and analog I/O cards.
Slot 1 supports a serial interface card (not released yet).
Optional interface cards
Card
MY8-TD
Format
TASCAM
Input
Output
8 OUT
8 IN
8 IN
8 IN
8 IN
4 IN
—
MY8-AT
MY8-AE
MY8-AD
MY4-AD
MY4-DA
AP8AD*
AP8DA*
ADAT
8 OUT
8 OUT
—
AES/EBU
ANALOG IN
ANALOG IN
ANALOG OUT
ANALOG IN
ANALOG OUT
—
4 OUT
—
8 IN
—
8 OUT
*: Manufactured by Apogee Corporation
Dimensions
480
I/O UNIT ID
PORT
B
SELECTOR
5-8
1-4
POWER
ON/ OFF
unit: mm
• Specifications and appearance are subject to change without notice for improvement.
• For European Model
Purchaser/User information specified in EN55103-1 and EN55103-2.
Inrush Current: 10A
Conformed Environment: E1, E2, E3 and E4.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
YAMAHA CORPORATION
Pro Audio & Digital Musical Instrument Division
P.O. Box 3, Hamamatsu, 430-8651, Japan
Download from Www.Somanuals.com. All Manuals Search And Download.
|