MODEL W1690
DELUXE CEILING MOUNTED
AIR CLEANER
INSTRUCTION MANUAL
COPYRIGHT © FEBRUARY, 2003 BY WOODSTOCK INTERNATIONAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT
THE WRITTEN APPROVAL OF WOODSTOCK INTERNATIONAL, INC.
Printed in China
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
PAGE
INTRODUCTION ....................................................................................2
About Your New Deluxe Ceiling Mounted Air Cleaner ........................................2
Woodstock Service and Support....................................................................2
Warranty and Returns................................................................................3
Specifications ................................................................................3
SAFETY..............................................................................................4
Standard Safety Instructions ....................................................................4-5
Additional Safety Instructions for Air Cleaners ................................................6
ELECTRICAL ........................................................................................7
110V Operation........................................................................................7
Extension Cords........................................................................................7
Grounding ..............................................................................................7
INSTALLATION ....................................................................................8
Unpacking ..............................................................................................8
Box Contents ..........................................................................................8
Shop Preparation ......................................................................................9
Dust System ............................................................................................9
Beginning ..............................................................................................10
Table-Top Mount ....................................................................................10
Hanging Mount........................................................................................11
Flush Mount ..........................................................................................12
OPERATION ......................................................................................13
Overview ..............................................................................................13
Control Panel ........................................................................................13
Remote Control ......................................................................................13
Troubleshooting......................................................................................14
MAINTENANCE....................................................................................15
Filters ..................................................................................................15
CLOSURE ..........................................................................................16
Parts Breakdown and Parts List ..............................................................17-18
USE THE QUICK GUIDE PAGE LABELS TO SEARCH OUT INFORMATION FAST!
-1-
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
About Your New Deluxe Ceiling
Mounted Air Cleaner
Your new SHOP FOX® Model W1690 Deluxe Ceiling Mounted Air Cleaner has been specially designed to
provide many years of trouble-free service. Close attention to detail, ruggedly built parts and a rigid
quality control program assure safe and reliable operation.
When used in conjunction with a dust collector system, the W1690 Deluxe Ceiling Mounted Air Cleaner
efficiently removes fine wood particles in the air that many dust collectors cannot. Your unit has key
features like a 5-micron outer filter, a washable 1-micron inner filter, three fan speeds, 110V operation,
remote control functions, and a compact design. For further features and details, refer to the
Specifications section on Page 3.
Woodstock International, Inc. is committed to customer satisfaction in providing this manual. It is our
intent to include all the information necessary for safety, ease of assembly, practical use and durability
of this product.
If you still have questions after reading the latest manual, or if you have comments please contact us at:
Woodstock International, Inc.
Attn: Technical Support Department
P.O. Box 2309
Bellingham, WA 98227
Woodstock Service and Support
We stand behind our machines! In the event that a defect is found, parts are missing or questions arise
about your machine, please contact Woodstock International Service and Support at 1-360-734-3482 or
send e-mail to: [email protected]. Our knowledgeable staff will help you troubleshoot problems,
order parts or arrange warranty returns.
-2-
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty and Returns
Woodstock International, Inc. warrants all SHOP FOX® machinery to be free of defects from
workmanship and materials for a period of 2 years from the date of original purchase by the original
owner. This warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence
or accidents, lack of maintenance, or to repairs or alterations made or specifically authorized by anyone
other than Woodstock International, Inc.
Woodstock International, Inc. will repair or replace, at its expense and at its option, the SHOP FOX®
machine or machine part which in normal use has proven to be defective, provided that the original
owner returns the product prepaid to the SHOP FOX® factory service center or authorized repair
facility designated by our Bellingham, WA office, with proof of their purchase of the product within 2
years, and provides Woodstock International, Inc. reasonable opportunity to verify the alleged defect
through inspection. If it is determined there is no defect, or that the defect resulted from causes not
within the scope of Woodstock International Inc.'s warranty, then the original owner must bear the cost
of storing and returning the product.
This is Woodstock International, Inc.'s sole written warranty and any and all warranties that may be
implied by law, including any merchantability or fitness, for any particular purpose, are hereby limited
to the duration of this written warranty. We do not warrant that SHOP FOX® machinery complies with
the provisions of any law or acts. In no event shall Woodstock International, Inc.'s liability under this
warranty exceed the purchase price paid for the product, and any legal actions brought against
Woodstock International, Inc. shall be tried in the State of Washington, County of Whatcom. We shall in
no event be liable for death, injuries to persons or property or for incidental, contingent, special or
consequential damages arising from the use of our products.
Every effort has been made to ensure that all SHOP FOX® machinery meets high quality and durability
standards. We reserve the right to change specifications at any time because of our commitment to
continuously improve the quality of our products.
Specifications
Motor ..............................................1⁄5 HP, 115V, 60 Hz, 1200 RPM, Single-Phase
Motor Amperage..................................HI = 3 Amps, MID = 21⁄2 Amps, LO = 2 Amps
Motor Low Speed ..........................................................................750 RPM
Motor Medium Speed ......................................................................960 RPM
Motor High Speed ........................................................................1200 RPM
Fan Low Speed Sound Rating ................................................................62 dB
Fan Medium Speed Sound Rating............................................................67 dB
Fan High Speed Sound Rating................................................................69 dB
Air Flow at Low Speed ....................................................................556 CFM
Air Flow at Medium Speed................................................................702 CFM
Air Flow at High Speed ..................................................................1044 CFM
Primary Filter ..............................................................................5-Micron
Secondary Filter............................................................................1-Micron
Unit Dimensions (L x W x H) ............................................301⁄4" x 241⁄8" x 121⁄8
"
Shipping Weight ..............................................................................64 lbs.
Installed Weight..............................................................................55 lbs.
-3-
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY
READ MANUAL BEFORE OPERATING MACHINE.
FAILURE TO FOLLOW INSTRUCTIONS BELOW WILL
RESULT IN PERSONAL INJURY.
Indicates an imminently hazardous situation which, if not avoided, WILL
result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, COULD
result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, MAY
result in minor or moderate injury.
This symbol is used to alert the user to useful information about proper
operation of the equipment, and/or a situation that may cause damage
to the machinery.
NOTICE
Standard Safety Instructions
1. Thoroughly read the instruction manual before operating your machine. Learn the applications,
limitations and potential hazards of this machine. Keep manual in a safe, convenient place for future
reference.
2. Keep work area clean and well lit. Clutter and inadequate lighting invite potential hazards.
3. Ground all tools. If a machine is equipped with a three-prong plug, it must be plugged into a three-
hole grounded electrical receptacle or grounded extension cord. If using an adapter to aid in
accommodating a two-hole receptacle, ground using a screw to a known ground.
4. Wear eye protection at all times. Use safety glasses with side shields or safety goggles that meet
the appropriate standards of the American National Standards Institute (ANSI).
5. Avoid dangerous environments. DO NOT operate this machine in wet or open flame environments.
Airborne dust particles could cause an explosion and severe fire hazard.
6. Ensure all guards are securely in place and in working condition.
7. Make sure the machine power switch is in the OFF position before connecting power to machine.
8. Keep the work area clean, free of clutter, grease, etc.
9. Keep children and visitors away. Visitors should be kept at a safe distance while operating unit.
10.Childproof your workshop with padlocks, master switches or by removing starter keys.
11.Stop and disconnect the machine when cleaning, adjusting or servicing.
-4-
Download from Www.Somanuals.com. All Manuals Search And Download.
12.DO NOT force tool. The machine will do a safer and better job at the rate for which it was designed.
13.Use correct tool. Do not force machine or attachment to do a job for which it was not designed.
14.Wear proper apparel. Do not wear loose clothing, neck ties, gloves, jewelry, and secure long hair
away from moving parts.
15.Remove adjusting keys, rags, and tools. Before turning the machine on, make it a habit to check
that all adjusting keys and wrenches have been removed.
16.Avoid using an extension cord. But if you must,
Extension Cord Requirements
examine the extension cord to ensure it is in good
TABLE 1
condition. Use TABLE 1 to determine the correct
length and gauge of extension cord needed for your
particular needs. The amp rating of the motor can be
found on its nameplate. If the motor is dual voltage,
be sure to use the amp rating for the voltage you will
be using. If you use an extension cord with an
undersized gauge or one that is too long, excessive
heat will be generated within the circuit, increasing
the chance of a fire or damage to the circuit. Always
use an extension cord that uses a ground pin and
connected ground wire. Immediately replace a
damaged extension cord.
Length and Gauge
Amp Rating
0-6
25ft
#16
#16
#16
#14
#12
#10
50ft 100ft
#16 #16
#16 #14
#16 #14
#12 #12
#12 #10
7-10
11-12
13-16
17-20
21-30
#10
No
17.Keep proper footing and balance at all times.
18.DO NOT leave machine unattended. Wait until it comes to a complete stop before leaving the area.
19.Perform machine maintenance and care. Follow lubrication and accessory attachment instructions
in the manual.
20.Keep machine away from open flame. Operating machines near pilot lights and/or open flames
creates a high risk if dust is dispersed in the area. Dust particles and an ignition source may cause
an explosion. Do not operate the machine in
high-risk areas, including but not limited to,
those mentioned above.
Always wear safety glasses or goggles when
operating equipment. Operating this
21.If at any time you are experiencing difficulties
equipment creates the potential for flying
performing the intended operation, stop using
debris that can cause eye injury. Everyday
glasses or reading glasses only have impact
resistant lenses, they are not safety glasses.
Be certain the safety glasses you wear meet
the appropriate standards of the American
National Standards Institute (ANSI).
the machine! Contact our service department or
ask a qualified expert how the operation should
be performed.
22. Habits—good and bad—are hard to break.
Develop good habits in your shop and safety will
become second-nature to you.
-5-
Download from Www.Somanuals.com. All Manuals Search And Download.
Additional Safety Instructions for Air Cleaners
Read and understand this
entire instruction manual
before using this machine.
Serious personal injury
may occur if safety and
operational information is
Use this and other machinery with caution
and respect, and always consider safety
first, as it applies to your individual working
conditions. Remember, no list of safety
guidelines can be complete, and every shop
environment is different. Failure to follow
guidelines can result in serious personal
injury, damage to equipment and/or poor
work results.
MODEL W1690
DELUXE CEILING MOUNTED
AIR CLEANER
INSTRUCTION MANUAL
On-Line Technical Support: [email protected]
not
understood
and
Phone: 1-360-734-3482
•
COPYRIGHT
©
JANUARY, 2003 BY WOODSTOCK INTERNATIONAL, INC.
WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT
THE WRITTEN APPROVAL OF WOODSTOCK INTERNATIONAL, INC.
Printed in China
followed. Do not risk your
safety by not reading!
•
•
ALWAYS secure any aprons, clothing, and long hair away from the intake side of the air cleaner unit
and any moving parts.
ALWAYS research the dangers of the specific species of wood you are working with as dust from
some woods are toxic and can make you sick, cause cancer, and lead to long-term respiratory
problems.
•
ALWAYS use a respirator along with a dust collection system when operating woodworking
machinery, and keep the filters of your air cleaner unit clean for optimum performance.
•
•
ALWAYS keep your hands and tools away from the fan output screen during fan operation.
ALWAYS turn the air cleaner OFF, let the fan and motor come to a complete stop, and unplug the
power source before leaving, servicing, adjusting, or troubleshooting the unit.
•
ALWAYS keep the filters serviced, and never attempt to replace filters or work on the machine
while it is operating.
•
•
ONLY operate this air cleaner unit in dry environments.
NEVER allow this air cleaner unit to operate in an environment that has volatile fumes from fuels,
paints, pesticides, chemicals, smoke; and never operate in an environment that has particles of
silica, metal, asbestos, or hazardous bacterium. This air cleaner unit is only designed to remove very
fine wood particles from the air. It is not a dust collector.
-6-
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRICAL
110V Operation
Grounding
The SHOP FOX® Model W1690 Deluxe Ceiling
Mounted Air Cleaner uses a 110V, single-phase,
1
⁄5
HP motor that draws approximately 3 amps
Any electrical outlet and
at the high speed setting.
circuit that you plug your
machine into must be
grounded. Serious injury
and/or fire may occur if this
warning is ignored!
Make sure the supply circuit, circuit breaker, or
fuse can carry the additional 3 amp load since
other machines may be using the same circuit. If
the total amperage load of all machines and the
air cleaner unit exceeds the amperage rating of
the circuit breaker or fuse, use a different
circuit that can carry the load.
Ground this machine! The electrical cord
supplied with the Model W1690 Air Cleaner has a
ground pin. If your power receptacle does not
have a ground pin hole, have the receptacle
replaced by a qualified electrician, or have an
appropriate adapter installed and grounded
properly.
DO NOT modify an existing low-amperage circuit
by only replacing the circuit breaker with a
breaker rated for a higher amperage. The
breaker and the complete circuit must be
replaced by a qualified electrician.
NOTICE
When using an electrical plug adapter, make
sure the adapter is grounded.
Extension Cords
We do not recommend using an extension cord
with most equipment because the cord can
generate heat that may cause fire or circuit
damage. If you must use an extension cord, use
the guidelines below.
NEVER cut the ground pin off so your air cleaner
unit will plug into a non-grounded receptacle.
See Figure 1. Remember, an adapter with a
grounding wire does not guarantee the air
cleaner unit is grounded. A ground source must
always be verified in the electrical circuit within
the wall or conduit.
•Use a cord rated for Standard Service
(Grade S)
•Use a cord that is 100 feet or less only
•Use a cord with a ground pin
•Use an undamaged cord only
Figure 1. NEVER cut the ground pin off so the
plug can fit into a non-grounded receptacle.
-7-
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Unpacking
3
1
Get lifting assistance to
2
remove the unit from the
box. At 55 pounds, the
Model W1690 Air Cleaner
is a heavy load.
The Model W1690 Deluxe Ceiling Mounted Air
Cleaner is carefully packed. However, if it is
damaged or is missing any parts, please contact
Woodstock International Service and Support at 1-
360-734-3482 or send e-mail to:
Figure 2. Model W1690 Deluxe Ceiling
Mounted Air Cleaner and filters.
No assembly is required for the Model W1690
Deluxe Ceiling Mounted Air Cleaner; however, you
should remove the filters and remove any packing
material that may be inside of the unit.
10
5
Hardware has been included for various air
cleaner mounting applications.
6
Box Contents
Layout and inventory the shipped parts to
familiarize yourself with your Model W1690
Deluxe Ceiling Mounted Air Cleaner. See
Figures 2 and 3. This will help with the
installation process.
9
4
7
8
Figure 3. Remote control and mounting
Item
Qty.
hardware.
1. W1690 Deluxe Ceiling Mounted Air Cleaner
2. Primary Filter (5-Micron, Pleated-Type)
3. Secondary Filter (1-Micron, Bag-Type)
4. Hand-Held Remote Control Unit
5. AAA Battery
1
1
1
1
2
4
8
8
4
4
6. Flange Bracket
7. Hex Bolt (M6-1.0 X 8)
8. Flat Washer (6 mm)
9. Eye Bolt (M6-1.0 x 20)
10. Rubber Foot
-8-
Download from Www.Somanuals.com. All Manuals Search And Download.
Shop Preparation
•
Working Clearances: Consider your current
and future shop needs with respect to the
machinery and the dust collection system
used. Make sure that the inlet and the outlet
have at least 12" of clearance between
obstructions as not to restrict the air flow.
The suction must be farther than 3 feet from
vents as the filter, if to close to vents, may
draw and filter air that is not from your work
area. You may have to create or modify other
shop ducting to achieve the correct working
clearances and airflow.
DO NOT operate this air
cleaner unit at a location
where flammable fuels,
solvents, or other volatile
chemicals may exist. Since
these products have a low
flash point, the fan motor
can ignite the fumes and
cause an explosion and
severe personal injury!
•
Outlets: Make sure the electrical circuits have
the capacity to handle the amperage
requirements of the new air cleaner unit.
Refer to Page 7 for more information.
Electrical outlets should be located near the
unit so power or extension cords are clear of
high-traffic areas.
DO NOT allow untrained
people in your shop! Make
sure shop entrances are
locked and machines are
correctly turned off with
lock-out devices when
not in use.
Otherwise,
injury or death can occur.
Dust System
When used in conjunction with a dust collector
system, the Model W1690 Deluxe Ceiling
Mounted Air Cleaner efficiently removes most
fine wood particles in the air that many dust
collectors cannot.
•
•
Machine Mobility: This air cleaner unit has a
balanced fan and uses digital components.
Move this air cleaner unit with care, and do
not drop or handle it roughly.
Operating Location: Operating this air
cleaner unit in the incorrect environment can
cause an explosion or respiratory damage to
you and others. This air cleaner unit is only
designed to help remove very fine wood
particles from the air. It is not a dust
collector, so take all necessary safety
precautions. The operating location must be
free of volatile fumes from fuels, paints,
pesticides, chemicals, smoke, and other
gasses; including an environment free of
silica, metal, asbestos, hazardous bacterium,
and other particles.
USE the correct dust
collection system in your
shop. This air cleaner unit is
not a dust collection system
and CANNOT be modified as
such. Ignoring this warning
can result in short and long-
term respiratory illness.
For additional information on the correct dust
collection system, additions, or modifications;
contact your Woodstock International dealer for
a copy of the Dust Collection Basics handbook
and available accessories.
Locate the air cleaner unit where the signal
path for the remote control is unobstructed
and is used within 75 feet of the control
panel. Often, the optimum location for this
air cleaner unit is at an overhead central shop
location and not at the corners.
-9-
Download from Www.Somanuals.com. All Manuals Search And Download.
Beginning
You can install the air cleaner unit three ways.
See Figures 4 and 5.
Hanging Mount
Eye Bolt
•
Table-Top Mount, use the rubber feet
and/or the flush mount flange brackets for
a table-top application. Refer to Page 10.
Flush Mount
Flange Bracket
•
•
Hanging Mount, use the eye bolts for a high
ceiling application. Refer to Page 11.
Table-Top
Mount
Rubber
Foot
Flush Mount, use the flange brackets for a wall
or low ceiling application. Refer to Page 12.
Figure 4. Air cleaner unit mounting options.
Keep the air cleaner unit
unplugged during all
installation procedures.
Ignoring this warning may
result in serious personal
injury to you or others!
Table-Top
Hanging Mount
Mount
Eye Bolt
Rubber
Foot
Table-Top Mount
You can use the air cleaner unit as a portable air
filtration system by installing the rubber feet
and placing the unit on a workbench or a table.
Flush Mount
Flange Bracket
Figure 5. Air cleaner unit mounting hardware.
Get lifting assistance
before installation. At 55
pounds, the Model W1690
air cleaner is a heavy load.
Rubber
Foot
To set up the air cleaner for table-top
operation, do these steps:
Flush Mount
Flange Bracket
Mounting Holes
1. With the help of an assistant, carefully invert
the air cleaner unit.
2. Expose the sticky backing on the foot, and
affix the rubber foot to the bottom of the air
cleaner unit. See Figure 6.
3. Repeat Step 2 for remaining feet.
Figure 6. Rubber feet correctly installed
(Underside View).
For permanent table-top mounting, refer to
the Flush Mount procedure on Page 12, and
install the air cleaner unit to the tabletop
with the flush mount flange brackets.
-10-
Download from Www.Somanuals.com. All Manuals Search And Download.
Hanging Mount
To make the unit operate at the optimum height
of 7 feet from the floor, you can install the air
filter unit in your shop by hanging it by chain,
cable, or steel strapping.
Plug Screw
Get lifting assistance
before installation. At 55
pounds, the Model W1690
air cleaner is a heavy load.
Figure 7. Plug screw.
ONLY hang the air cleaner to load bearing
ceiling supports or joists that can hold at least
100 lbs. DO NOT mount the unit to sheet rock,
pressboard, paneling, or honeycomb ceiling
panels with expansion-type fasteners like the
ones shown in Figure 10. The fasteners can tear
out and the air cleaner can fall. Ignoring this
warning can result in severe injury or death.
To install the air cleaner for hanging mount
operation, do these steps:
1. Install four chain, cable, or steel strapping
lines to your ceiling from capable ceiling
studs or supports. When the lines hang down
freely they should be 151⁄4" from left-to-right
and 241⁄2" from front-to-rear.
Figure 8. Eye bolt correctly seated.
2. Remove the plug screw. Retain the screws
because if you remove the eye bolts for the
flush mounting configuration, you must
reinstall these screws to seal the air cleaner
unit. See Figure 7.
3. Thread the eye bolt completely into the air
filter unit until the jam-nut shoulder contacts
the air filter unit. See Figure 8.
4. Tighten the eye bolt until it is snug against
the air filter unit.
5. Repeat Steps 2 through 5 on the three
remaining eye bolts.
6. Raise and secure the air cleaner eye bolts to
the four hanging lines.
-11-
Download from Www.Somanuals.com. All Manuals Search And Download.
Flush Mount
You can install the air filter unit in a confined
shop by mounting it flush to a ceiling, wall, or
table using the flange mounts.
ONLY mount the air cleaner unit to load bearing
supports, wall studs, or table that can hold at
least 100 lbs. DO NOT mount the unit to sheet
rock walls, pressboard, paneling, or honeycomb
wall panels with expansion-type fasteners like
the ones shown in Figure 10. The fasteners can
tear out and the air cleaner can fall. Ignoring this
warning can result in severe injury or death.
Figure 9. Typical unacceptable fasteners.
Get lifting assistance
before installation. At 55
pounds, the Model W1690
air cleaner is a heavy load.
Lip
Mounting
holes
To install the air cleaner for flush mount
operation, do these steps:
1. Locate the applicable load bearing studs or
supports in the wall or ceiling, and mark the
air cleaner unit bolt pattern on the wall or
ceiling (171⁄4" from left-to-right and 31" from
front-to-rear).
Figure 10. Flange bracket mounting holes and lip.
1
2. Drill the bolt pattern to accept at least ⁄4
"
1
Flange bracket
shank lag bolts for studs, or use ⁄4" nuts,
bolts, and washers for mounting to supports.
mounted under lip
3. Position the flange bracket under the air
cleaner unit lip at the mounting hole location.
See Figure 10. For permanent table top
mounting, use the lower-lip holes.
4. Install the flat washers and the hex bolts to
secure the flange brackets to the unit. See
Figure 11.
5. Repeat Steps 3 and 4 for the other three
Figure 11. Flange correctly installed under lip.
flange brackets.
6. With the help of an assistant, position the air
cleaner on the wall or ceiling, and screw or
bolt the unit in place.
-12-
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Overview
Control Panel
When the Model W1690 Deluxe Ceiling Mounted
Air Cleaner is turned on, the fan motor starts on
HI and then switches to the speed of your
selection. Air is drawn through the primary
filter, through the secondary filter, then the
cleaned air is distributed into your shop.
The control panel enables you to manually turn the
air cleaner ON and OFF, and set the fan speed.
The panel has a remote control unit signal
receiver, a 5-ampere fuse for circuit protection,
and a series of LED lights that indicate your speed
and auto shut-off selections. See Figure 12.
NOTICE
ALWAYS take a few moments to listen and
observe for unusual noise and vibration after
starting the air cleaner.
To operate the air cleaner unit, use the listed
controls:
•
OFF: Allows you to manually turn the air
cleaner OFF.
•
ON / SPEED: Allows you to turn the unit ON
with the first push of the button, and for
every additional push, the fan speed is
cycled from LO, MID, and HI. Speed
selection is indicated by a red LED light.
Figure 12. Control Panel.
Remote Control
The remote control unit enables you to remotely
turn the air cleaner ON and OFF, set the fan
speed, and set the auto shut-off time. The remote
control unit uses two AAA alkaline batteries as a
power source. The remote control unit must be
within 75 feet and have an unobstructed infrared
signal path to the control panel in order to control
the air filter. See Figure 13.
To operate the remote control unit, use the
listed controls:
•
OFF: Allows you to remotely shut the air
cleaner off.
•
ON / SPEED: Allows you to remotely turn the
unit ON with the first push of the button,
and for every additional push, the fan speed
is cycled from LO, MID, and HI.
•
TIME: Allows you to set the auto shut-off
time from no auto shut-off, to auto shut-off
in 1 hour, 2 hours, and 4 hours.
Figure 13. Remote Control.
-13-
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Use this troubleshooting chart to solve any common problems with your Model W1690 Air Cleaner.
SYMPTOM
POSSIBLE REASON
HOW TO REMEDY
The air
cleaner
does not
operate at
all.
The power supply circuit breaker is tripped.
Correct the cause for high current draw and
close the circuit breaker.
No power to the control panel.
Wiring is at fault.
Replace the blown fuse in the control panel.
Repair, replace wires, plugs and cables as
applicable; and make sure all electrical plugs
and connections are secure.
The control panel circuit board is at fault.
The motor is at fault.
Replace the circuit board.
Replace the motor.
The remote The remote control has no power.
Install or replace the batteries.
control does
not operate The signal path is obstructed.
the air
cleaner but
Make sure the signal path is clear to the
infrared remote control sensor on the control
panel.
the control
panel
operates
fine.
The remote control is at fault.
Replace the hand-held remote control unit.
Replace the control panel circuit board.
The control panel circuit board is at fault.
The filters are wet or clogged.
The air
Replace the primary filter and clean the
secondary filter.
cleaner CFM
output is
reduced.
The airflow path is obstructed.
Remove obstructions or add ducting.
Replace the control panel circuit board.
Replace the motor.
The control panel circuit board is at fault.
The motor is at fault.
The mounting is loose.
The air
filter unit is
noisy or
Tighten the flange brackets and reinstall the
air cleaner unit.
vibrates.
The unit is not level.
Level the air cleaner unit.
The fan or motor is loose.
Unplug the unit, remove the filters, and
tighten all loose fasteners.
-14-
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
Filters
The amount of use has a direct bearing on when
you must change the primary air filter and service
the secondary air filter. Contact your SHOP
FOX® dealer for other possible filter types
available.
Filter Retainer Latch
Keep the air cleaner unit
unplugged during all
maintenance procedures.
Ignoring this warning may
result in serious personal
injury to you or others!
Figure 14. 5-Micron primary filter.
Always wear a dust mask
and safety glasses when
servicing and changing
filters. Sawdust may
cause allergic reactions
or respiratory problems.
To change and service the filters, do these steps:
1. Unplug the air cleaner unit.
2. Move the filter retainer latch upward, remove
the primary filter and discard it. See Figure 14.
Figure 15. 1-Micron secondary filter.
NOTICE
DO NOT use compressed air to blow out the
secondary filter. If you do, you will damage
the filter and reduce filtering quality.
3. Remove the secondary filter and shake out the
wood dust until clean and/or wash out with warm
water and let dry. See Figure 15.
4. Vacuum out the inside of the air cleaner housing.
See Figure 16.
5. Reinstall the secondary filter when it is dry and
Figure 16. Air cleaner housing.
install a new primary filter.
6. Move the filter retainer latch downward to
lock all the filters in place.
-15-
Download from Www.Somanuals.com. All Manuals Search And Download.
CLOSURE
The following pages contain parts diagrams/lists
We recommend you keep this manual for
complete information regarding Woodstock
International, Inc.’s warranty and return policy.
Should a problem arise, we recommend that you
keep your proof of purchase with your manual.
If you need additional technical information
relating to this machine, or if you need general
assistance or replacement parts, please contact
the Service Department at 1-360-734-3482 or
e-mail: [email protected].
and a warranty card for your SHOP FOX® Model
W1690.
If you need parts or help in assembling your
machine, or if you need more operational
information, we encourage you to call our
Service Department. Our trained service
technicians will be glad to help you.
If you have comments dealing specifically with
this manual, please write to us using the address
in the General Information. The specifications,
drawings, and photographs illustrated in this
manual represent the Model W1690 as supplied
when the manual was prepared. However, due
to Woodstock International, Inc.’s policy of
continuous improvement, changes may be made
at any time with no obligation on the part of
Woodstock International, Inc. Whenever
possible, though, we send manual updates to all
owners of a particular tool or machine that have
registered their purchase with our warranty
card. Should you receive one, add the new
information to this manual and keep it for
reference.
Additional information sources are necessary to
realize the full potential of this machine. Trade
journals, woodworking magazines, and your
local library are good places to start.
The Model W1690 is specifically designed for air
filtering operation. DO NOT MODIFY AND/OR
USE THIS MACHINE FOR ANY OTHER PURPOSE.
MODIFICATIONS OR IMPROPER USE OF THIS
TOOL WILL VOID THE WARRANTY. If you are
confused about any aspect of this machine, DO
NOT use it until all your questions have been
answered.
We have included some important safety
measures that are essential to the operation of
the machine. While most safety measures are
generally universal, we remind you that each
workshop is different and safety rules should be
considered as they apply to your specific
situation.
Operating this equipment has the potential
for flying debris to cause eye injury. Always
wear safety glasses or goggles when
operating equipment. Everyday glasses or
reading glasses only have impact resistant
lenses, they are not safety glasses. Be
certain the safety glasses you wear meet
the appropriate standards of the American
National Standards Institute (ANSI).
-16-
Download from Www.Somanuals.com. All Manuals Search And Download.
-17-
Download from Www.Somanuals.com. All Manuals Search And Download.
REF
PART #
DESCRIPTION
REF
PART #
DESCRIPTION
33 X1690033
34 X1690034
35 X1690035
36 X1690036
37 X1690037
38 XPLN02M
39 X1690039
40 X1690040
41 X1690041
42 XPW03M
43 XPB29M
45 X1690045
46 XPW03M
47 XPB04M
48 X1690048
49 XPK48M
50 XPB06M
51 X1690051
52 X1690052
53 X1690053
54 X1690054
55 XPLW03M
56 XPS11M
CLIP SET
1
2
3
4
5
6
7
8
9
X1690001
X1690002
X1690003
X1690004
X1690005
X1690006
X1690007
X1690008
X1690009
REMOTE CONTROL
LABEL (CONTROLS)
CAPACITOR
INSULATOR
CAPACITOR CLAMP
MOTOR
HEX LOCKING NUT M5-0.8
FLANGE
SPACER
REMOTE CONTROL COVER
AAA ALKALINE BATTERY
FUSE HOLDER
1
⁄8"
1
FUSE 5-AMP (250VAC)
POWER CORD 3-WIRE 18-GA
STRAIN RELIEF
CONTROL PANEL
PHLP HD SCR M4-0.7 X 10
LABEL (CONTROLS)
PC BOARD
PHLP HD SCR M3-0.45 X 6.5
SPACER (SPECIAL)
PHLP HD SCR (SPECIAL)
SLEEVE
FLAT WASHER 6MM
HEX BOLT M6-1.0 X 30
FLANGE BRACKET
FLAT WASHER 6MM
HEX BOLT M6-1.0 X 10
FAN
KEY 4 X 4 X 20MM
HEX BOLT M8-1.25 X12
FLANGE DISK 6.5 X 44MM
CAP SCREW M6-1.0 X 20 (LH)
FAN HOUSING
TAPPING SCREW
LOCK WASHER 6MM
PHLP HD SCR M6-1.0 X 16
FLAT WASHER 6MM
LABEL (DUST MASK)
LABEL (EXPLODE)
LABEL (SHOP FOX)
LABEL (HANDS AWAY)
HOUSING
10 XPS38M
11 X1690011
12 X1690012
13 XPS53M
14 X1690014
15 X1690015
16 XPTLW04M EXT TOOTH WSHR 4MM
17 XPN30M
18 XPW05M
19 XPLW02M
20 XPS54M
21 X1690021
22 X1690022
23 X1690023
24 X1690024
25 X1690025
26 X1690026
27 X1690027
28 X1690028
29 X1690029
30 X1690030
HEX NUT M4-0.75
FLAT WASHER 4MM
LOCK WASHER 4MM
PHLP HD SCR M4-0.75 X 6
PC WIRING HARNESS
BOLT (SPECIAL) M3-0.45 X 6.5
EYE BOLT M6-1.0 X 20
RUBBER BUSHING
LARGE LABEL (ELECTRICAL)
RIVET NUT M6 X 8
SMALL LABEL (ELECTRICAL)
RUBBER FOOT
HANDLE
57 XPW03M
58 X1690058
59 X1690059
60 X1690060
61 X1690061
62 X1690062
63 X1690063
LABEL (UNPLUG POWER)
LABEL (MACHINE DATA)
MOUNT AND BOLT BAG
PRIMARY FILTER 5-MICRON
FOAM SEAL 1⁄4" X 1" X 70"
SECONDARY FILTER 1-MICRON
64 X1690064
65 X1690065
31 X1690031
32 X1690032
-18-
Download from Www.Somanuals.com. All Manuals Search And Download.
FOLD ALONG DOTTED LINE
Place
Stamp
Here
WOODSTOCK INTERNATIONAL, INC.
P.O. BOX 2309
BELLINGHAM, WA 98227-2309
FOLD ALONG DOTTED LINE
TAPE ALONG EDGES--PLEASE DO NOT STAPLE
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY CARD
Name __________________________________________________________________________________________
Street __________________________________________________________________________________________
City ____________________________________________________________________State________Zip_________
Phone Number_______________________E-Mail_________________________________FAX___________________
MODEL # _____________ Serial #_____________ Purchase Date _____________ Time in Use _______________
The following information is given on a voluntary basis and is strictly confidential.
1.
2.
Where did you purchase your SHOP FOX® machine?
10.
What stationary woodworking tools do you own? Check all that apply.
_________________________________________________________
___Air Compressor
___Band Saw
___Panel Saw
___Planer
How did you first learn about us?
___Drill Press
___Power Feeder
___Radial Arm Saw
___Shaper
___Spindle Sander
___Table Saw
___Drum Sander
___Dust Collector
___Horizontal Boring Machine
___Jointer
___Advertisement
___Friend
___Mail order Catalog
___World Wide Web Site
___Local Store
___Lathe
___Mortiser
___Vacuum Veneer Press
___Wide Belt Sander
___Other__________________________________________________
Which of the following magazines do you subscribe to.
___Other__________________________________________________
3.
11.
12.
13.
Which benchtop tools do you own? Check all that apply.
___American Woodworker
___Cabinetmaker
___Today’s Homeowner
___Wood
___1" x 42" Belt Sander
___5" - 8" Drill Press
___8" Table Saw
___8" - 10" Bandsaw
___Disc/Belt Sander
___Mini Jointer
___6" - 8" Grinder
___Mini Lathe
___10" - 12" Thickness Planer
___Scroll Saw
___Spindle/Belt Sander
___Family Handyman
___Fine Homebuilding
___Fine Woodworking
___Home Handyman
___Wooden Boat
___Woodshop News
___Woodsmith
___Woodwork
___Journal of Light Construction
___Old House Journal
___Popular Mechanics
___Popular Science
___Woodworker
___Woodworker’s Journal
___Workbench
___Other__________________________________________________
___American How-To
Which portable/hand held power tools do you own? Check all that apply.
___Popular Woodworking
___Other__________________________________________________
Which of the following woodworking/remodeling shows do you watch?
___Belt Sander
___Biscuit Joiner
___Circular Saw
___Detail Sander
___Drill/Driver
___Miter Saw
___Orbital Sander
___Palm Sander
___Portable Planer
___Saber Saw
___Reciprocating Saw
___Router
4.
5.
6.
___Backyard America
___Home Time
___The New Yankee Workshop
___This Old House
___The American Woodworker
___Woodwright’s Shop
___Other__________________________________________________
___Other__________________________________________________
What is your annual household income?
What machines/supplies would you like to see?
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
___$20,000-$29,999
___$30,000-$39,999
___$40,000-$49,999
___$50,000-$59,999
___$60,000-$69,999
___$70,000-$79,999
___$80,000-$89,999
___$90,000 +
14.
15.
16.
What new accessories would you like Woodstock International to carry?
_________________________________________________________
_________________________________________________________
What is your age group?
Do you think your purchase represents good value?
___20-29
___30-39
___40-49
___50-59
___60-69
___70 +
___Yes
Would you recommend SHOP FOX® products to a friend?
___Yes ___No
___No
7.
8.
9.
How long have you been a woodworker?
___0 - 2 Years
___2 - 8 Years
___8 - 20 Years
___20+ Years
17.
Comments:________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
How would you rank your woodworking skills?
___Simple
___Advanced
___Master Craftsman
___Intermediate
How many SHOP FOX® machines do you own? _____________
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|