P R O W A L L C H I M N E Y V E N T I L AT I O N H O O D S
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
INSTALLATION R E Q U I R E M E N T S
IMPORTANT NOTE: This installation must be
completed by a qualified installer or Wolf
WARNING – TO REDUCE THE
authorized service center technician.
RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Installer: Please read the entire Installation
Instructions prior to installation. Save these
instructions for the local inspector’s refer-
ence, then leave them with the homeowner.
R AT I N G P L AT E
I N F O R M AT I O N
Homeowner: Please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
Model Number
A) Installation work and electrical
wiring must be done by qualified
person(s) in accordance with all
applicable codes and standards,
including fire-rated construction.
Any questions or problems about the installa-
tion should be directed to your Wolf dealer or
Wolf Appliance, Inc. at 800-332-9513. You can
also visit our website at wolfappliance.com.
Serial Number
B) When cutting or drilling into wall
or ceiling, do not damage electrical
wiring and other hidden utilities.
IMPORTANT NOTE: This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings are listed on the product
rating plate.
C) Ducted fans must always be
vented to the outdoors.
The hood motor has a thermal overload
which will automatically shut off the
motor if it becomes overheated. The
motor will restart when it has cooled
down. If the motor continues to shut off
and restart, have the hood serviced.
Record the model and serial numbers before
installing the hood. Both numbers are listed on
the rating plate, located on the back wall of the
hood shell. Refer to the illustration below.
Rating plate located
inside back wall
Rating plate location
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
L I S T O F MATERIALS
INSTALLATION C O N S I D E R AT I O N S
The following is a list of materials shipped
with the Wolf Pro wall chimney hood.
Wolf Pro wall chimney ventilation hoods are
recommended for use with all Wolf cooking
appliances.
Stainless steel wall chimney hood
Proper installation is the responsibility
of the installer. Product failure due to
improper installation is not covered
under the Wolf Warranty. Refer to the
Wolf Pro Ventilation Hoods Use & Care
Information for warranty details, or visit
the Contact/Help section of our website,
wolfappliance.com.
Wall Chimney Hood
Transition with backdraft damper—
attached inside hood (needs to be removed)
Decorative stainless steel rail and installa-
tion components—(R) model hoods only
Two control knobs
Wall Chimney Hood
(R) Rail Option
Filters and grease cups (installed in hood)
Wood mounting strip
Make sure you have the tools and materials
necessary for proper installation.
Installation package
Warranty service must be performed by a
Wolf authorized service center. Wolf is not
responsible for service required to correct a
faulty installation.
Installation Instructions
Use & Care Information and product
registration card
IMPORTANT NOTE: Wolf Pro ventilation
hoods are shipped without the blower
assembly. Wolf internal, in-line and remote
blower assemblies are available, refer to page
17. Use only a Wolf blower with the Pro wall
chimney hood.
Wolf logo nameplate
IMPORTANT NOTE: Wolf recommends that
the Pro wall chimney hood be installed 30"
(762) to 36" (914) above the countertop.
Rail option (R) wall chimney hoods come with
a classic stainless steel decorative rail and
stand-offs. Optional platinum or brass rails are
available to match Wolf dual fuel range bezels.
Contact your Wolf dealer for details.
If you are installing an optional duct cover with
the Pro wall chimney hood, refer to instruc-
tions on page 10 before installing the hood.
When performing installation, servicing
or cleaning the unit, it is recommended
to wear safety glasses and gloves.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
ELECTRICAL R E Q U I R E M E N T S
OVERALL D I M E N S I O N S
Wolf Pro wall chimney ventilation hoods
require a separate, grounded 110/120 V AC,
60 Hz power supply. The service should have
its own 15 amp circuit breaker. Locate the
electrical supply through the top of the hood
as shown in the Installation Specifications
illustration below. Refer to Install Wiring on
pages 12–13.
P RO WA L L C H I M N E Y H O O D S
Overall Widths
36" (914), 42" (1067),
48" (1219), and 54" (1372)
Overall Height
18" (457)
Overall Depth (excluding rail)
Shipping Weight (shell only)
24" (610)
67–126 lbs
(30–57 kg)
You must follow all National Electrical Code
regulations. In addition, be aware of local
codes and ordinances when installing your
service.
Unit dimensions may vary to 1/8" (3).
1
TOP WIDTH
13 /2"
(343)
SUBTRACT 18" (457) FROM OVERALL WIDTH
3
/4" (19)
18" (457)
OVERALL
HEIGHT
DIAMETER
OF RAIL
4" (102)
OVERALL WIDTH
24" (610)
OVERALL DEPTH
2"
(51)
Pro wall chimney hood shown with (R) rail option.
INSTALLATION S P E C I F I C AT I O N S
LOCATION OF
6"
E
ELECTRICAL (152)
5"
(127)
18" (457)
HEIGHT
OF HOOD
WIDTH OF HOOD
30" TO 36"
(762–914)
30" TO 36"
(762–914)
24" (610)
DEPTH OF HOOD
TO COUNTERTOP
TO COUNTERTOP
NOTE: Pro wall chimney hoods have a vertical discharge.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
INSTALLATION S P E C I F I C AT I O N S
The illustration and chart below provides
dimensions specific to each Pro wall chimney
hood model. These dimensions are critical for
proper installation.
To reduce the risk of fire and electric
shock, install this ventilation hood only
with a blower manufactured by Wolf.
Blower model numbers are listed on
page 17.
Pro Wall Chimney Hoods
Model
(A)
(B)
(C)
(D)
PWC362418(R)
PWC422418(R)
PWC482418(R)
PWC542418(R)
36" (914)
42" (1067)
48" (1219)
54" (1372)
18" (457)
24" (610)
30" (762)
36" (914)
7" (178)
7" (178)
7" (178)
7" (178)
9" (228)
12" (304)
18" (457)
24" (610)
Letters correspond to those in the illustrations.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
I N S TA L L DUCTWORK
To reduce the risk of fire, use only metal
ductwork.
DUCTWORK INSTALLATION
THROUGH ROOF
ROOF CAP OR REMOTE BLOWER
10" (254) ROUND DUCT
IMPORTANT NOTE: Wolf recommends that
the Pro wall chimney hood be installed
30" (762) to 36" (914) above the countertop.
TRANSITION
14"W x 93/4"D TO 10" ROUND
7"H (INCLUDING FLANGES)
IMPORTANT NOTE: All Pro wall chimney
hoods must exhaust to the outdoors. Always
use metal ducting. Do not use flex ducting.
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE
Decide where the ductwork will run between
the hood and the outside. A straight, short
duct run will allow the hood to perform more
efficiently. Limit the number of elbows and
transitions to as few as possible. Long duct
runs, elbows and transitions will reduce the
performance of the hood. Wolf recommends
the maximum linear duct run be no greater
than 50' (15 m). Pro wall chimney hoods have
a vertical discharge.
3
18" (457)
HEIGHT
OF HOOD
16 /4" (425)
WALL HOOD
TOP OF WOOD
MOUNTING STRIP
24" (610)
DEPTH OF HOOD
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
IMPORTANT NOTE: There is a possibility of
noise issues, if there is a short duct run
coupled with a remote blower.
Always install a roof or wall cap if you are not
installing a remote blower. Connect 10" (254)
round metal ductwork to the cap and work
back towards the hood. Use duct sealing tape
on joints between ductwork sections.
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
Wolf Pro wall chimney hoods come standard
with a backdraft damper included in the transi-
tion assembly. Local codes may require the
use of an additional backdraft damper. Contact
your local HVAC professional for specific
requirements. In cold weather installations, a
backdraft damper is necessary to minimize the
backflow of cold air into the room.
NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS.
Ducting for wall chimney hoods
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
WALL F R A M I N G
IMPORTANT NOTE: There must be a
minimum 10" (254) opening in the ceiling to
accommodate the ductwork necessary for
proper ventilation.
Framing must be tied together and to
ceiling joists to provide enough structural
strength to support the weight of the hood
and internal blower, if applicable.
Layout the dimensions of the back of the
wall chimney hood on the wall (shaded
area of illustration below). The back of the
hood dimensions will vary with the size of
the hood. For dimensions of your model,
refer to the illustration and chart on
page 12.
Due to the weight of the hood, ensure
that the wood strip is attached to all
available wall studs and blockings.
Use minimum 2" x 4" lumber to build the
framing. Proper structural support is
required to accommodate the weight of the
hood.
Mark the center location of the hood. Install
2" x 4" blockings between wall studs. Refer
to the illustration below.
Measure and mark a level line on the wall
above the cooking surface for the wood
mounting strip.
Use four #10 x 2" (51) flat head screws to
secure the mounting strip to the wall studs
and blockings.
Existing
Wall Studs
Wood Mounting
Strip
Back of Wall Hood
Outline
16¾"
2 x 4 Blocking
(425)
16"
(406)
14"
(356)
2" (51)
Framing for wall chimney hoods
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
HOOD P R E PA R AT I O N
Follow these steps to prepare the wall chimney
hood for installation:
IMPORTANT NOTE: If internal blower Model
CTBLOWER-60INT or CTBLOWER-90INT will be
used with the 36" (914) or 42" (1067) wide
hood, do not reinstall the transition yet.
Remove the filters by pressing up at the
angle the filters are placed in, then rotate
the bottom of the filter down. Gloves
should be worn to provide proper grip.
If you are installing a remote blower, punch
out the knockout hole located on the top of
the hood. Install a wire clamp (included
with the hood) for remote blower cable.
Refer to the remote blower information on
page 16 and follow installation instructions
provided with the blower assembly.
Slide the grease cups out from the bottom
edges of the back of the hood.
Using a Phillips screwdriver, remove the
screws retaining the internal frame (shaded
area of the illustration below) to the hood.
Be careful not to remove the two other
screws (refer to the illustration below).
Do not discard the screws. They will be
reinstalled after installation of the hood is
complete.
Install one wire clamp (included with the
hood) in the hole on top of the hood for the
power cable.
Do not run wiring for the remote blower
through the ductwork.
Remove the internal frame from the hood
and set aside.
The hood assembly is shipped with the
transition attached. The transition is
shipped upside down in the top of the hood
and must be removed and reinstalled in the
proper position.
Separate the transition from the hood
assembly by removing the four shipping
screws. Invert and reattach the transition to
the hood with the shipping screws.
Do not
remove
Do not
remove
Internal frame screws location
Spring
Filter
Grease
Cup
SIDE VIEW
Remove filters
Remove internal frame
Dimensions in parentheses are in
millimeters unless otherwise specified.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
DUCT COVER I N S TA L L AT I O N
Duct covers 6" (152), 12" (305), 18" (457) and
24" (610) high in widths to match all wall
chimney hoods are available through your
Wolf dealer. To obtain local dealer information,
visit the Locator section of our website,
wolfappliance.com.
Installing a duct cover assembly will
impact all aspects of the hood installa-
tion including hood location, ducting,
electrical placement and the mounting
surface.
AC C E S S O R I E S
Optional acces-
sories are available
through your
IMPORTANT NOTE: If internal blower Model
CTBLOWER-60INT or CTBLOWER-90INT will be
used with the 36" (914) or 42" (1067) wide
hood, do not install the duct cover yet. The
internal blower must be installed before
installing the duct cover.
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
wolfappliance.com.
IMPORTANT NOTE: If an optional duct cover
is to be used with the Pro wall chimney hood,
follow these instructions before installing the
hood:
Attach the duct cover from the inside of the
hood through the filter opening using the
screws provided with the duct cover.
Leave the screws partially loose until all
screws are installed. Check the alignment of
the duct cover with the hood and tighten
the four corner screws to secure the duct
cover. Tighten all remaining screws.
Optional
Duct
Cover
Mounting
Screws
Duct cover installation
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
HOOD I N S TA L L AT I O N
IMPORTANT NOTE: If an optional duct cover
is to be used with the Pro wall chimney hood,
it must be installed before installing the hood—
except for the 36" (914) and 42" (1067) wide
hoods with an internal blower. Refer to Duct
Cover Installation on page 10.
Using two #8 x 2" (51) screws provided—
four for 48" (1219) and 54" (1372) wide
hoods, secure the hood to the wood
mounting strip at the location shown in the
illustration below.
Using two #8 x 2" (51) screws and washers
provided, secure the top back of the hood
to the wall studs and/or blockings by the
upper slots. Then use three #8 x 2" (51)
screws and washers in the lower slots to
complete the installation of the hood to the
wall. Refer to the illustration below.
Due to the weight of the hood, be sure
to have adequate manpower for installa-
tion.
Connect the 10" (254) round ductwork to
the transition using sheet metal screws and
duct sealing tape.
The filters and internal frame must be removed
from the hood prior to installation. Refer to
Hood Preparation on page 9.
If you are installing an internal blower, do
not reinstall the internal frame and filters
until the blower installation is complete.
Refer to Internal Blowers on page 15 and
follow installation instructions provided
with the blower.
Rest the top back cavity of the hood on the
wood mounting strip.
Hold the hood until it is completely
secured to the wood mounting strip.
Make electrical connections. Refer to Install
Wiring on pages 12–13.
Holes to
reach wood
mounting strip
Back of wall hood
(inside view)
Upper slots
Lower slots
Hood installation
Dimensions in parentheses are in
millimeters unless otherwise specified.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
I N S TA L L WIRING
I N T E R N A L B L OW E R W I R I N G
Risk of electrical shock. This ventilation
hood must be properly grounded. This
unit should be installed by a qualified
electrician in accordance with all applica-
ble national and local electrical codes and
standards.
Remove the hood electrical box cover.
Run power cable to the installation location.
Insert the power cable into the electrical
box by running it through the wire clamp
previously installed. Tighten the wire clamp
to secure the cable. Refer to the illustration
below for the location of the electrical box.
I M P O RTA N T
N OT E
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
When making electrical connections, make
sure the electrical power is turned off at
the power source or circuit breaker before
proceeding.
Risk of electrical shock. Do not remove
the wire connector on the ORANGE wire
from the hood.
Using the supplied wire connectors, connect
wires as follows: BLACK wire from hood to
power supply BLACK wire, WHITE wire
from hood to power supply WHITE wire and
GREEN or BARE wire from power supply to
GREEN ground screw in the electrical box.
Before servicing or cleaning unit, switch
power off at service panel and lock the
service disconnecting means to prevent
power from being switched on acciden-
tally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag,
to the service panel.
Place all wiring connections inside the
electrical box and reinstall the cover. Make
sure that the wires are secure and that no
wires are pinched between the cover and
box.
Do not remove the control knob bezel to
access hood wiring; this will damage the
bezel assembly.
Location of Knockout for Wiring
Model
Hood Width
36" (914)
(A)
PWC362418(R)
PWC422418(R)
PWC482418(R)
PWC542418(R)
2" (51)
3" (76)
4" (102)
4" (102)
42" (1067)
48" (1219)
54" (1372)
Letter (A) corresponds to the illustration.
Location of wiring
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
I N S TA L L WIRING
I N - L I N E O R R E M OT E B L OW E R W I R I N G
Remove the hood electrical box cover.
Run power cable to the installation location.
Insert the power cable into the electrical
box by running it through the wire clamp
previously installed. Tighten the wire clamp
to secure the cable.
Place all wiring connections inside the
electrical box and reinstall the cover. Make
sure that the wires are secure and that no
wires are pinched between the cover and
box.
Run the blower cable to the installation
location. Insert the blower cable into the
electrical box by running it through the
other wire clamp previously installed.
Tighten the wire clamp to secure the cable.
Cut off the butt crimp connector from the
end of ORANGE wire in hood. Strip
ORANGE wire about 3/8" (10). Using an
appropriate wire connector (not included),
connect BLACK wire from blower to
ORANGE wire from hood. Using the
supplied wire connectors, connect other
wires as follows: BLACK wire from hood to
power supply BLACK wire, all WHITE wires
together and GREEN or BARE wires from
power supply and blower to GREEN ground
screws in the electrical box. Refer to the
wiring diagram below.
BLK
WHT
BLK
Power cable
120 V
WHT
WHT
WHT
WHT
BLK
WHT
HS
WHT
THERMOSTAT
3
In-line or Remote
blower cable
1
2
WHT
BLK
ORA
ORA
BLK
WHT
BRN
YEL
WHT
YEL
YEL
RED
BLK
BLK
BLU
BLK
BLK
BLK
WHT
YEL
L
H
BLK
SPEED
CONTROL
SPEED
LIGHT
SWITCH
CONTROL
BLK
COLOR CODE
BLK
BLACK
BLUE
BROWN
ORANGE
RED
WHT
YEL
RED
WHITE
YELLOW
BLU
BRN
ORA
M
M
Internal blower
Wiring diagram
Dimensions in parentheses are in
millimeters unless otherwise specified.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
FILTER I N S TA L L AT I O N
WOLF N A M E P L AT E
Follow these instructions to install filters and
grease cups for Wolf Pro wall chimney hoods:
The Wolf logo nameplate does not come
installed on the hood since there are various
locations that the nameplate can be attached.
Also, some customers prefer not to have a
nameplate on their hood.
Reinstall the internal frame. Refer to Hood
Preparation on page 9.
Remove all packaging material from the
filters and grease cups.
A template for positioning the Wolf logo
nameplate in a standard location is included
on page 19. Follow these steps to install the
nameplate:
Slide the grease cups along the bottom
edge of the hood so that the lip of the
grease cup overhangs slightly.
Decide on the location for the nameplate.
Install the filters. Orient each filter with
lines running vertically. Position the top
edge of the filter as shown in the illustra-
tion below. While pressing up against the
spring, rotate the bottom edge of the filter
into position next to the grease cup. Gloves
should be worn to provide proper grip
when installing filters.
Clean the mounting area with rubbing
alcohol.
If desired, cut out the template from page
19. Fold the template, locate placement on
hood and tape to the hood surface. Check
alignment and adjust if necessary.
Remove backing paper from the nameplate.
Position the nameplate in the template
cut-out and press into place.
Remove the template and any tape residue.
Spring
Filter
Grease
Cup
SIDE VIEW
Filter and grease cup installation
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
INTERNAL B L OW E R S
IMPORTANT NOTE: Refer to the specific
installation instructions provided with each
internal blower for additional mounting and
wiring instructions.
Reattach the transition to the hood with the
shipping screws. If you are installing a duct
cover with the hood, refer to instructions on
page 10.
AC C E S S O R I E S
C T B L OW E R - 6 0 I N T / C T B L OW E R - 9 0 I N T
I B L OW E R - 1 2 0 I N T
Remove filters and internal frame from the
hood. Refer to Hood Preparation on page 9.
Remove filters and internal frame from the
hood. Refer to Hood Preparation on page 9.
Optional acces-
sories are available
through your
Fasten the four hex nuts (included with the
blower) to the four blower studs leaving a
1/4" (6) gap.
Discard the hex nut (included with the
blower).
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
Lift the blower into position inside the hood.
Lift the blower into position inside the hood.
Engage the two tabs on the blower into the
two slots on top of the hood. Secure the
blower to the threaded studs with the two
hex nuts (included with the hood). Refer to
the illustration below.
Engage all the blower studs in the keyholes
on top of the hood. From the top of the
hood, secure the blower to the hood by
tightening completely the four hex nuts on
the threaded studs. Refer to the illustration
below.
wolfappliance.com.
Plug the blower power cords into recepta-
cles near the center of the hood shell. Use
the clips on the interior of the hood to keep
excess power cord away from moving parts.
Plug the blower power cord(s) into recepta-
cle(s) near the center of the hood shell. Use
the clips on the interior of the hood to keep
excess power cord away from moving parts.
Once installation of the blower is complete,
replace the internal frame and filters.
Once installation of the blower is complete,
replace the internal frame and filters.
IMPORTANT NOTE: Before turning the power
on to the ventilation hood, make sure the
blower is off.
IMPORTANT NOTE: Before turning the power
on to the ventilation hood, make sure the
blower is off.
Hex Head Nuts
Top of Hood
Top of Hood
Threaded
Studs
Top of Hood
Hex Head Nuts
Slot
Threaded
Studs
Power
Cords
Threaded
Studs
Tab
Power
Cord
Internal Blower
Internal Blower
Internal Blower
Power
Cords
Hex Head Nuts
CTBLOWER-60INT
CTBLOWER-90INT
IBLOWER-120INT
Dimensions in parentheses are in
millimeters unless otherwise specified.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
IN-LINE A N D REMOTE B L OW E R S
B L OW E R I N S TA L L AT I O N
Be sure that there is enough space for any
transitions that may be needed between the
blower and the connecting ductwork. For best
performance, locate transitions nearest the
blower.
IMPORTANT NOTE: Refer to the specific
installation instructions provided with each
blower for additional mounting instructions.
Locate the blower so that the length of the
duct run and number of elbows and transitions
are kept to a minimum. Wolf recommends the
maximum linear duct run be no greater than
50' (15 m).
Refer to the illustrations below and on the
following page for overall dimensions of Wolf
in-line and remote blowers. Also refer to the
specific installation instructions provided with
each remote blower to verify cut-out dimen-
sions.
If possible, remote blowers should be located
between wall studs or roof rafters. Avoid
pipes, wires or other ductwork that may be
running through the wall.
IMPORTANT NOTE: Before turning the power
on to the ventilation hood, make sure the
blower is off.
When making electrical connections,
make sure the electrical power is turned
off at the power source or circuit breaker
before proceeding.
18" (457)
21" (533)
10"
3
20 /4"
10"
(527)
(254)
(254)
1
1
29 /2"
1
28 /4"
29 /2"
(749)
(718)
(749)
10" (254)
Diameter
10" (254)
Diameter
10" (254)
Diameter
1
3
15 /2"
(394)
3
14 /4"
(375)
14 /4"
(375)
1
1
29 /2"
1
29 /2"
24 /2"
(749)
(749)
(622)
1
3
14"
10 /8"
10 /8"
(356)
(257)
(264)
3
4
/4"
3
(121)
24 /4"
(629)
1
7
1
7
22"
25"
/4"
/4"
(559)
(635)
(184)
(184)
Dimensions for BLOWER-90REM
Dimensions for BLOWER-120REM
Dimensions for BLOWER-150REM
16
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION I N S T R U C T I O N S
BLOWER A S S E M B L I E S
Wolf Pro wall chimney ventilation hoods are
shipped without the blower assembly. Wolf
internal, in-line and remote blower assemblies
are available as sales accessories through your
Wolf dealer.
I N T E R N A L B L OW E R S
CTBLOWER-60INT (801644) – 600 CFM
internal blower for wall chimney hoods;
36" (914) and 42" (1067) wide models.
AC C E S S O R I E S
CTBLOWER-90INT (801645) – 900 CFM
internal blower for wall chimney hoods;
36" (914) and 42" (1067) wide models.
IMPORTANT NOTE: Blower options vary with
the cooking surface. Use only a Wolf blower
with the Pro wall chimney hood.
Optional acces-
sories are available
through your
IBLOWER-120INT (804703) – 1200 CFM
internal blower for wall chimney hoods;
48" (1219) and 54" (1372) wide models.
Refer to the Wolf Design Guide for Pro
ventilation recommendations. You can also
visit our website at wolfappliance.com.
Wolf dealer. To
obtain local dealer
information, visit
the Locator section
of our website,
I N - L I N E B L OW E R
wolfappliance.com.
BLOWER-110IL (808332) – 1100 CFM in-
line blower for all wall chimney hoods.
R E M OT E B L OW E R S
BLOWER-90REM (801641) – 900 CFM
remote blower for all wall chimney hoods.
BLOWER-120REM (801642) – 1200 CFM
remote blower for all wall chimney hoods.
BLOWER-150REM (804701) – 1500 CFM
remote blower for all wall chimney hoods.
7
24 /8"
(632)
18"
12"
(457)
(305)
8"
(203)
22"
18"
(559)
(457)
Dimensions for BLOWER-110IL
Dimensions in parentheses are in
millimeters unless otherwise specified.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
WO L F PRO WALL CHIMNEY V E N T I L AT I O N H O O D S
TROUBLES H O OT I N G
I F YO U N E E D SERVICE
IMPORTANT NOTE: If the Pro wall chimney
ventilation hood does not operate properly,
follow these troubleshooting steps:
Maintain the quality built into your Pro
wall chimney ventilation hood by calling a
Wolf authorized service center.
Verify that power is being supplied to the
ventilation hood.
For the name and number of the Wolf
authorized service center nearest you,
check the Locator section of our website,
wolfappliance.com, or call Wolf Customer
C O N TAC T
I N F O R M AT I O N
Check electrical connections to ensure that
the installation has been completed
correctly.
Service at 800-332-9513
.
Wolf Customer
Service:
800-332-9513
When calling for service, you will need the
model and serial number of your ventilation
hood. This information is found on the
rating plate located on the back wall of the
hood shell. Refer to the illustration on
page 3.
Refer to the Troubleshooting Guide in the
Wolf Pro Ventilation Hoods Use & Care
Information.
Website:
wolfappliance.com
If the ventilation hood still does not work,
contact a Wolf authorized service center. Do
not attempt to repair the ventilation hood
yourself. Wolf is not responsible for service
required to correct a faulty installation.
The information and images are the copyright
property of Wolf Appliance, Inc., an affiliate of
Sub-Zero, Inc. Neither this book nor any
information or images contained herein may be
copied or used in whole or in part without the
express written permission of Wolf Appliance, Inc.,
an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
19
LEFT OUTER EDGE OF HOOD
Download from Www.Somanuals.com. All Manuals Search And Download.
WOLF APPLIANCE, INC.
P. O. BOX 44848
MADISON, WI 53744
800-332-9513
WOLFAPPLIANCE. COM
810482
6 / 2007
Download from Www.Somanuals.com. All Manuals Search And Download.
|