				To open the lamp   
					The Lens Ring is unscrewed from the Body to gain access to internal parts and the   
					Dry Cell cassette.   
					To fit primary cells   
					Withdraw battery cassette from body and load with four cells, negative cell end positioned   
					to spring, positive cell end positioned to cup washer. Flattened cells must be removed   
					immediately to avoid over discharge and cell leakage.   
					To operate and replace the switch   
					The slide switch operates as indicated on the approval label. It consists of a magnet, a plastic   
					housing and a cap. To replace, prise off cap and remove housing. Fit the new switch housing   
					and magnet to the lamp body and ‘snap’ the cap in place.   
					To replace bulb   
					The bulb is retained by the screwed centre contact at the back of the reflector.   
					4.8 volts, 0.5 amps, Krypton. Part No. H-26K.   
					To replace glass disc or reflector   
					The above parts are secured in the lens ring by the reflector retaining ring. All parts should   
					be cleaned and the rubber washer centralised before reassembly. A key is available for   
					this assembly.   
					To replace the reed switch   
					Both contacts are removed to replace the reed switch, ensure central relocation.   
					The Wolf Safety Lamp Co. Ltd. has a policy of continuous product improvement.   
					Changes in design details may be made without prior notice.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Spare Parts List for   
					‘Wolflite’ Safety Handlamp H-4DC   
					H-4DC   
					Description   
					H-104   
					H-03   
					H-09   
					'O' ring seal (black)   
					Magnet Switch complete   
					Reed Switch   
					H-11   
					H-12   
					Sleeve for Shorting Link   
					Link Contact   
					H-13   
					Battery Contact   
					H-14   
					H-15DC   
					H-17   
					Screw for Contacts   
					Body Complete   
					Lens Ring   
					H-18   
					Washer for Disc   
					H-19   
					H-21A   
					H-22   
					H-24   
					H-25   
					Glass Disc toughened   
					Reflector   
					Reflector Retaining Ring   
					Reflector Distance Piece   
					Bulb Socket   
					H-26K   
					H-29   
					H-31K   
					H-34   
					H-35SB   
					H-42DC   
					H-48   
					Bulb 4.8V 0.5A (2.4W) Krypton   
					Centre Contact complete   
					Lens Ring complete   
					Key for Reflector Retaining Ring   
					Lanyard (clip on type)   
					Primary Cell Cassette complete   
					Shorting Link   
					H-58   
					T-20   
					Handlamp Wall Holder   
					Zinc Chloride Cell (R20)   
					WOLF SAFETY LAMP COMPANY   
					Saxon Road Works, Sheffield S8 0YA, England   
					Tel: +44 114 255 1051 Fax: +44 114 255 7988   
					E-mail: info@wolf-safety.co.uk   
					
					MMD/U/8.04/5K   