Wibur Curtis Company Ice Tea Maker PTTD 3 User Manual

FIND OUT MORE  
ON THE WEB.  
WILBURCURTIS.COM  
WILBUR CURTIS COMPANY, INC.  
Iced Tea Brewer Instructions  
Important Safeguards/Conventions  
MODELS INCLUDED  
• TCTD-35  
• TCTD-35S  
• PTTD-3  
• TCO-308  
• TCO-417  
This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be  
performed by an authorized Wilbur Curtis service center.  
Do NOT immerse the unit in water or any other liquid  
To reduce the risk of fire or electric shock, do NOT open top or front panel. No user serviceable parts inside.  
Repair should be done only by authorized service personnel.  
Keep hands and other items away from hot parts of unit during operation.  
Never clean with scouring powders, bleach or harsh implements.  
• TCO-421  
Conventions  
WARNING HOT LIQUID,  
Scalding may occur.  
Avoid splashing.  
WARNINGS – To help avoid personal injury  
Important Notes/Cautions – from the factory  
Sanitation Requirements  
CAUTION: Please use  
this setup procedure  
Curtis ADS System is Factory Pre-Set and Ready to Go… Right from the Carton.  
Following are the Factory Settings for your Iced Tea Brewing System:  
before attempting to use  
this brewer. Failure to follow the  
instructions can result in injury or  
• Brew Temperature = 204°F  
• Concentrate = 1 Gallon  
System Requirements  
• Dilution = 2 Gallon  
the voiding of the warranty.  
• Drip Mode = 30 Seconds  
• Water Source: 20 – 100PSI (Min Flow Rate of 1 GPM)  
• Electrical: See attached schematic for standard  
CAUTION: DO NOT  
connect this brewer to  
hot water. The inlet valve  
Equipment to be installed to comply with applicable federal, state, or local plumbing/electrical codes having jurisdiction.  
SETUP STEPS  
is not rated for hot water.  
1. Place unit at counter height. on a firm, level base, in such a way that it can be connected to water and power supply.  
2. Connect water line to inlet fitting on valve. Water pressure entering brewer is required to be stable and must provide  
minimum of 1 gallon per minute. Use water regulator for constant pressure. Required water pressures, 20 to 100 psi.  
2. Plug power cord into electrical outlet rated 20A.  
3. Turn on toggle switch, behind unit. Heating tank will start filling. When the water reaches probe,heating element  
turns on automatically.  
4. Heating tank will require 20 to 30 minutes to attain operating temperature. READY TO BREW indicator will light at  
this time.  
5. Insert brewcone. Place empty tea container under brew cone. With water at operating temperature, run brew cycle,  
without tea, for about 1 minute. This clears the water lines of air. Stop the brew cycle by switching off at ON/OFF  
button. Discard water in tea container.  
The National Sanitation Foundation requires the following water connection:  
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for  
cleaning underneath.  
2. In some areas an approved backflow prevention device may be required between the brewer and the water supply.  
WARNING TO AVOID  
SCALDING, Do not  
remove brewcone while  
brew light is flashing.  
BREWING  
INSTRUCTIONS  
1. Place filter in brew basket. 2. Slide brew cone into brew 3. Press the BREW button to  
Pour leaf tea into basket.  
rails. Place tea container  
under brew cone.  
brew tea.  
C
ISO 9001 REGISTERED  
WILBUR CURTIS COMPANY  
Montebello, CA 90640  
FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO  
WWW.WILBURCURTIS.COM  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Illustrated Parts List - TCTD-35/35S Curtis Iced Tea Brewer, Continued from page 2  
ITEM PART N  
                                                                                                                                                                                                                                                                                                                
º
                                                                                                                                                                                                                                                                                                                
DESCRIPTION  
17  
17A  
18  
19  
20  
21  
22  
23  
23A  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
WC- 102  
WC- 103  
WC-1438  
WC-5231  
WC-5851  
WC-43062  
SWITCH, TOGGLE SPST 25A 125/250 VAC RESISTIVE  
SWITCH, TOGGLE DPST 25A 125/250 VAC RESISTIVE  
SENSOR, HEATING TANK  
COMPOUND, SILICONE 5 OZ  
COVER, TANK W/NOTCHES  
GASKET, TANK LID  
WC-5502-01 PROBE ASSY, LL W/HEX FITTING, O-RING & NUT  
WC- 904  
WC- 906  
WC-4394  
WC- 522  
WC-43055  
WC-29009  
WC-6210  
WC-54096  
WC-3685  
WC-5310  
WC-7115  
WC-7119  
WC-38103  
WC-3724  
WC-37260  
WC-1805  
WC-1803  
WC-3707  
ELEMENT, HEATING 1.6 KW, 120V W/JAM NUTS  
ELEMENT, HEATING 2 KW 220V W/JAM NUTS  
SHOCK GUARD, HEATING ELMT  
THERMOSTAT, HI LIMIT HEAT CNTRL DPST 277V 40A  
GUARD, SHOCK RESET THERMOSTAT  
FITTING, TANK INLET/DRAIN  
SHIELD, BUBBLE  
TANK ASSY, COMPLETE TCTD-35/S PTTD  
INSULATION WRAP, PTTD/TCTD  
TUBE, 5/16" ID x 1/8” W SILICONE  
LID, TEA OVAL  
SHELL, W/A TCO421  
LABEL, FRONT  
KIT, E-Z VIEW REPLACEMENT  
KIT, FAUCET W/ADAPTER COMPL  
SEAT CUP, FAUCET S’  
FAUCET, SPB  
KIT, REPAIR SPB FAUCET  
Illustrated Parts List - PTTD Iced Tea Brewer  
ITEM PART Nº DESCRIPTION  
1
2
3
4
5
6
7
8
9
WC-3322  
WC-3358  
WC-39260  
WC- 750  
WC-2977-01  
WC-5450  
WC-5310  
WC-2906  
WC-2965  
C-2407  
BASKET, WIRE 6.423 DIA PTTD/TCTD, USED W/WC-3320  
BREW CONE ASSY, W/WC-3320, WC-3322 & WC-3647  
MEMBRANE CONTROL PANEL  
CONTROL BOARD 120V 60Hz PTTD/TCTD  
FITTING ASSY, SPRAYHEAD W/0-RING  
COVER, TOP BREWER  
TUBING, SILICONE 5/16" I.D.  
SPRAYHEAD, BLUE .178” DIA ORF  
SPOUT ASSY, BYPASS  
10  
COVER, CENTER WRAP  
11 WC-8556  
12 WC- 895  
13 WC-5448  
13A WC-85008  
14 WC-3500  
15 WC-6917  
16 WC- 102  
17 WC-5851  
18 WC-2959  
19 WC-29015  
20 WC-54096  
21 WC-5502-01  
22 WC- 904  
23 WC- 522  
24 WC-4394  
25 WC-43055  
26 WC-43058  
27 WC-5231  
28 WC-1438  
29 WC-7115  
30 WC-71183  
31 WC-38102  
32 WC-3724  
33 WC-37260  
34 WC-1805  
35 WC-1803  
36 WC-3707  
HEAT SINK ASSY  
VALVE, DUAL INLET 120V .5GPM COLD, .25GPM HOT 10W  
SUPPORT, DECK PTTD  
SUPPORT, DECK EXTENDED SS (SHOWN)  
LEG, 4” ADJUSTABLE  
LABEL, BOTTOM PTTD  
SWITCH, TOGGLE SPST 25A, 125/220VAC RESISTIVE  
COVER, TANK W/NOTCHES  
FITTING, SYPHON TUBE BRASS  
FITTING ASSY, OVERFLOW PLATED, TIN NICKEL  
TANK ASSY, COMPLETE  
PROBE ASSY, LL W/HEX FITTING, O-RING & NUT  
ELEMENT, HEATING 1.6 KW 120V W/JAM NUTS  
THERMOSTAT, HI LIMIT HEAT CONTROL DPST 277V 40A  
GUARD, SHOCK HTG ELEMENT  
GUARD, SHOCK RST TSTAT  
PLUG, PP RED DRAIN  
COMPOUND, SILICONE 5 OZ  
SENSOR, HEATING TANK  
LID, TEA OVAL  
SHELL W/A TCO-308  
LABEL, FRONT  
KIT, E-Z VIEW REPLACEMENT  
KIT, FAUCET W/ADAPTER COMPL  
SEAT CUP, FAUCET S’  
FAUCET, SPB  
KIT, REPAIR SPB FAUCET  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL  
SCHEMATIC  
WARRANTY We hereby certify that the products manufactured by the Wilbur Curtis Company, Inc., are, to thebest of our knowledge, free from all defects and faulty workmanship.  
The following warranties and conditions are applicable:  
90 Days for Labor and 1 Year Parts from Date of Purchase from Factory: This warranty covers all electrical parts, fittings and tubing.  
40 Months or 40, 000 Pounds of Coffee on a set of Grinding Burrs. (ADS Grinders)  
• 2 Years from Date of Purchase: This warranty covers electronic control boards and leaking or pitting of a stainless steel body of a Brewer or Urn.  
90 Days from Date of Purchase: On replacement parts that have been installed on out of warranty equipment  
All in-warranty service calls must have prior authorization from the manufacturer. For an RMA (Return Merchandise Authorization) number, call the Technical Service Department at 1-800-995-0417. The Wilbur Curtis  
Company will allow up to 100 miles, round trip, per in-warranty service call.  
CONDITIONS & EXCEPTIONS  
The warranty covers original equipment at time of purchase only. The Wilbur Curtis Company, Inc., assumes no responsibility for substitute replacement parts installed on Curtis equipment that have not been purchased  
from the Wilbur Curtis Company. Inc The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under these circumstances:  
1) Improper operation of equipment. The equipment must be used for its designed and intended purpose and function.  
2) Improper installation of equipment. This equipment must be installed by a professional, certified technician and must comply with all local electrical, mechanical and plumbing codes.  
3) Wilbur Curtis Company will not be responsible for the operation of equipment at other than the stated voltages on the serial plate.  
4) Abuse or neglect (including failure to periodically clean or remove lime accumulations). Manufacturer is not responsible for variation in equipment operation due to excessive lime or local water  
conditions.  
5) Replacement of items subject to normal use and wear. This shall include, but is not limited to, light bulbs, shear disks, “0” rings, gaskets, canister assemblies. whipper chambers and plates, mixing  
bowls, agitation assemblies and whipper propellers.  
6) Any faults resulting from inadequate water supply. This includes, but is not limited to, excessive or low water pressure, and inadequate or fluctuating water flow rate.  
7) All repairs and/or replacements are subject to our decision that the workmanship or parts were faulty and the defects showed up under normal use.  
8) All labor shall be performed during regular working hours. Overtime charges are the responsibility of the owner.  
9) Charges incurred by delays, waiting time, or operating restrictions that hinder the service technician’s ability to perform service is the responsibility of the owner of the equipment.  
This includes institutional and correctional facilities.  
10) All claims under this warranty must be submitted to the Wilbur Curtis Company Technical Service Department before return of the unit to the factory.  
11) All equipment returned to us must be repackaged properly in the original carton. No units will be accepted if they are damaged in transit due to improper packaging.  
12) Damaged in transit.  
13) The resetting of safety thermostats and circuit breakers, programming and temperature adjustments are the responsibility of the equipment owner.  
NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA). RMA NUMBER MUST BE MARKED ON THE CARTON OR SHIPPING LABEL.  
All in-warranty service calls must be performed by an authorized service center, where service is available. Call the factory for location near you.  
WILBUR CURTIS CO., INC.  
6913 Acco St., Montebello, CA 90640-5403 USA  
Phone: 800/421-6150  
Fax: 323-837-2410  
Technical Service Phone: 800/995-0417 (M-F 5:30A - 4:00P PST) E-Mail: [email protected]  
FOR THE LATEST SPECIFICATION INFORMATION GO TO WWW.WILBURCURTIS.COM  
4
Printed in U.S.A. 6/03 F-3131-S Rev A  
6/5/03 .10.8 . ecn 5894 Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym WESY77731 User Manual
Weider Home Gym XT20 User Manual
Weil McLain Burner 1050FFD W User Manual
Whistler Radar Detector XTR 555 User Manual
Williams Sound Stereo System R1 216 User Manual
Windsor Vacuum Cleaner LB2000 User Manual
Xantrex Technology Stud Sensor 975 0193 01 01 User Manual
Xerox Flat Panel Television VW37L User Manual
Xerox Network Router 2314 User Manual
Zanussi Cooktop ZCV550 User Manual