F92-1011  
Regulated L.P. to Natural Gas  
Conversion Kit for 36G/36J Two-Stage  
INSTALLATION INSTRUCTIONS  
Installer: Save these instructions for future use!  
FAILURETOREADANDFOLLOWALLINSTRUCTIONSCAREFULLYBEFORE  
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL  
INJURY AND/OR PROPERTY DAMAGE.  
WARNING  
TO CONVERT FROM L.P. TO NATURAL GAS  
!
This conversion kit shall be installed by a qualified  
service agency in accordance with the manufacturer’s  
instructionsandallapplicablecodesandrequirements  
oftheauthorityhavingjurisdiction.Iftheinformationin  
1. Remove both regulator cover screws.  
2. Remove both regulator adjustment screws (beneath the  
cover screws).  
these instructions is not followed exactly, a fire, explo-  
sion, or production of carbon monoxide may result,  
causing property damage, personal injury, or loss of  
life. The qualified service agency performing the work  
assumes the responsibility for the proper conversion  
of this appliance with this kit.  
3. Remove both regulator springs from regulator sleeves. (L.P.  
configuration may be two L.P. springs, color-coded white, or  
one L.P., color-coded white, and one Natural, color-coded  
silver/plain).  
4. Insert the Natural Gas regulator springs (provided in the  
conversion kit and color-coded silver/plain) into the regulator  
sleeves.  
5. Replace the High regulator adjustment screw and adjust  
approximately 14 turns from top of sleeve.  
APPLICATION  
This conversion kit allows the 36G Series and 36J Series Two-  
Stage gas valves to be used on Natural gas applications. This  
conversion kit is for use on all 36G/36J Two-Stage, fast and  
slow open models.  
6. Replace the Low regulator adjustment screw and adjust  
approximately 10 turns from top of sleeve.  
7. Adjust both outlet pressures to the appliance manufacturer's  
requirements.  
8. Replace both regulator cover screws.  
High  
Low  
9. Remove the L.P. WARNING label, if  
present, fromthegasvalve. Alsoattachthe  
small round NAT GAS labels to the top of  
the regulator cover screws.  
!
WARNING  
VALVE CONVERTED FOR USE ON L.P.  
GAS. IMPROPER OPERATION COULD  
RESULT IN DEATH OR SERIOUS  
INJURY.  
Regulator  
Cover Screw  
!
MISE EN GARDE  
SOUPAPE CONVERTIE POUR USAGE  
SUR GAZ DE PÉTROLE LIQUÉFIÉ.  
UN FONCTIONNEMENT INAPPROPRIÉ  
PEUT PROVOQUER LA MORT OU DES  
BLESSURES GRAVES.  
Plastic Regulator  
Adjustment Screw  
WARNING Label  
Regulator Spring  
Natural Gas Regulator  
Springs (silver/plain)  
NAT.  
GAS  
NAT.  
GAS  
Natural Gas Labels  
Figure 2. Contents of kit  
Figure 1. 36G/36J 2-Stage models  
PARTNO.37-6586B  
Replaces 37-6586A  
1005  
White-Rodgers is a division  
of Emerson Electric Co.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weil McLain Boiler LGB 4 User Manual
Weslo Treadmill R 72 User Manual
Whirlpool Washer WTW6200SW0 User Manual
White Outdoor Lawn Mower ZT 1850, ZT 2150, ZT 2250 User Manual
Wolf Cooktop ICBCT15E User Manual
Woodstock Sander W1751 User Manual
Yamaha Electronic Keyboard H01 User Manual
Zanussi Oven ZDC 888 User Manual
Zenoah Brush Cutter BK3501FL User Manual
Zephyr Ventilation Hood CPA E42ASX User Manual