INSTALLATION INSTRUCTIONS  
30" (76.0 CM) FREESTANDING ELECTRIC RANGES  
Table of Contents  
RANGE SAFETY .............................................................................1  
INSTALLATION INSTRUCTIONS ..................................................4  
Unpack Range..............................................................................4  
Install Anti-Tip Bracket.................................................................5  
Electrical Connection ...................................................................6  
Verify Anti-Tip Bracket Location ................................................11  
Level Range................................................................................11  
Complete Installation..................................................................11  
Moving the Range ......................................................................12  
INSTALLATION REQUIREMENTS................................................2  
Tools and Parts ............................................................................2  
Location Requirements................................................................2  
Electrical Requirements ...............................................................3  
RANGE SAFETY  
Your safety and the safety of others are very important.  
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  
messages.  
This is the safety alert symbol.  
This symbol alerts you to potential hazards that can kill or hurt you and others.  
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”  
These words mean:  
You can be killed or seriously injured if you don't immediately  
follow instructions.  
DANGER  
You can be killed or seriously injured if you don't  
instructions.  
follow  
WARNING  
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can  
happen if the instructions are not followed.  
WARNING  
Tip Over Hazard  
A child or adult can tip the range and be killed.  
Connect anti-tip bracket to rear range foot.  
Reconnect the anti-tip bracket, if the range is moved.  
Failure to follow these instructions can result in death or serious burns to children and adults.  
IMPORTANT:  
Save for local electrical inspector's use.  
W10258095A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Connection  
Cabinet Dimensions  
To properly install your range, you must determine the type of  
electrical connection you will be using and follow the instructions  
provided for it here.  
Cabinet opening dimensions shown are for 25" (64.0 cm)  
countertop depth, 24" (61.0 cm) base cabinet depth and  
36" (91.4 cm) countertop height.  
Range must be connected to the proper electrical voltage  
and frequency as specified on the model/serial number rating  
plate. The model/serial number rating plate is located behind  
the control panel or on the oven frame behind the storage  
drawer or warming drawer panel. Refer to the figures in the  
“Product Dimensions” section of the “Location  
IMPORTANT: If installing a range hood or microwave hood  
combination above the range, follow the range hood or  
microwave hood combination installation instructions for  
dimensional clearances above the cooktop surface.  
Requirements” section.  
This range is manufactured with the neutral terminal  
connected to the cabinet. Use a 3-wire, UL listed, 40- or  
50-amp power supply cord (pigtail) (see following Range  
Rating chart). If local codes do not permit ground through the  
neutral, use a 4-wire power supply cord rated at 250 volts,  
40 or 50 amps and investigated for use with ranges.  
A
C
B
D
Range Rating*  
Specified Rating of  
Power Supply Cord Kit  
and Circuit Protection  
F
G
H
G
F
J
120/240 Volts  
120/208 Volts  
Amps  
K
I
8.8 - 16.5 KW  
16.6 - 22.5 KW  
7.8 - 12.5 KW  
12.6 - 18.5 KW  
40 or 50**  
50  
L
E
*The NEC calculated load is less than the total connected load  
listed on the model/serial rating plate.  
**If connecting to a 50-amp circuit, use a 50-amp rated cord with  
kit. For 50-amp rated cord kits, use kits that specify use with a  
nominal 1³⁄₈" (34.9 mm) diameter connection opening.  
A circuit breaker is recommended.  
A. 13" (33.0 cm) upper cabinet  
depth  
B. 30" (76.2 cm) min. opening width  
C. For minimum clearance to the  
top of the cooktop,  
see NOTE*  
D. 30¹⁄₈" (76.5 cm) min. opening  
width  
E. Junction box in shaded area  
F. 3⁵⁄₁₆" (8.4 cm)  
G. 7" (14.6 cm)  
H. 9¹⁄₂" (24.1 cm)  
I. 7" (14.6 cm)  
J. 22" (55.9 cm)  
K. 3" (7.6 cm)  
The range can be connected directly to the circuit breaker  
box (or fused disconnect) through flexible or nonmetallic  
sheathed, copper or aluminum cable. See “Electrical  
Connection.”  
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that  
the range can be moved if servicing is ever necessary.  
L. Cabinet door or hinge should  
not extend into the cutout.  
A UL listed conduit connector must be provided at each end  
of the power supply cable (at the range and at the junction  
box).  
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal  
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant  
millboard covered with not less than No. 28 MSG sheet steel,  
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or  
0.020" (0.5 mm) copper.  
Wire sizes and connections must conform with the rating of  
the range.  
The wiring diagram is located on the back of the range in a  
clear plastic bag.  
30" (76.2 cm) minimum clearance between the top of the cooking  
platform and the bottom of an uncovered wood or metal cabinet.  
If connecting to a 4-wire system:  
This range is manufactured with the ground connected to the  
neutral by a link. The ground must be revised so the green  
ground wire of the 4-wire power supply cord is connected to the  
cabinet. See “Electrical Connection.”  
Electrical Requirements  
If codes permit and a separate ground wire is used, it is  
recommended that a qualified electrical installer determine that  
the ground path and wire gauge are in accordance with local  
codes.  
Grounding through the neutral conductor is prohibited for new  
branch-circuit installations (1996 NEC); mobile homes; and  
recreational vehicles, or an area where local codes prohibit  
grounding through the neutral conductor.  
Do not use an extension cord.  
Be sure that the electrical connection and wire size are adequate  
and in conformance with the National Electrical Code, ANSI/  
NFPA 70-latest edition and all local codes and ordinances.  
When a 4-wire receptacle of NEMA Type 14-50R is used, a  
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power  
supply cord (pigtail) must be used. This cord contains 4 copper  
conductors with ring terminals or open-end spade terminals with  
upturned ends, terminating in a NEMA Type 14-50P plug on the  
supply end.  
A copy of the above code standards can be obtained from:  
National Fire Protection Association  
One Batterymarch Park  
Quincy, MA 02269.  
WARNING: Improper connection of the equipment-grounding  
conductor can result in a risk of electric shock. Check with a  
qualified electrician or service technician if you are in doubt as to  
whether the appliance is properly grounded. Do not modify the  
power supply cord plug. If it will not fit the outlet, have a proper  
outlet installed by a qualified electrician.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
The fourth (grounding) conductor must be identified by a green or  
green/yellow cover and the neutral conductor by a white cover.  
Cord should be Type SRD or SRDT with a UL listed strain relief  
and be at least 4 ft (1.22 m) long.  
If connecting to a 3-wire system:  
Local codes may permit the use of a UL listed, 3-wire, 250-volt,  
40- or 50-amp range power supply cord (pigtail). This cord  
contains 3 copper conductors with ring terminals or open-end  
spade terminals with upturned ends, terminating in a NEMA Type  
10-50P plug on the supply end. Connectors on the appliance end  
must be provided at the point the power supply cord enters the  
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.  
4-wire receptacle (14-50R)  
The minimum conductor sized for the copper 4-wire power  
cord are:  
40-amp circuit  
3-wire receptacle (10-50R)  
2 No.-8 conductors  
1 No.-10 white neutral  
1 No.-8 green grounding  
INSTALLATION INSTRUCTIONS  
Unpack Range  
4. On Ranges Equipped with Storage Drawers:  
Remove the storage drawer. If a range height adjustment is  
necessary, use a ¼" drive ratchet to lower the rear leveling  
legs one-half turn. Use a wrench or pliers to lower front  
leveling legs.  
WARNING  
Excessive Weight Hazard  
Use two or more people to move and install range.  
Failure to do so can result in back or other injury.  
A
D
C
1. Remove shipping materials, tape and film from range.  
2. Remove oven racks and parts package from inside oven.  
3. Do not remove the shipping base at this time.  
B
A. ¼" drive ratchet  
B. Rear leveling leg  
C. Wrench or pliers  
D. Front leveling leg  
A
On Ranges Equipped with Warming Drawers:  
If a range height adjustment is necessary, use wrench or pliers  
to lower the front and rear leveling legs.  
A. Shipping base  
A
B
C
A. Rear leveling leg  
B. Front leveling leg  
C. Wrench or pliers  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install Anti-Tip Bracket  
Floor Mounting  
WARNING  
A
B
Tip Over Hazard  
A child or adult can tip the range and be killed.  
Connect anti-tip bracket to rear range foot.  
Reconnect the anti-tip bracket, if the range is moved.  
Failure to follow these instructions can result in death  
or serious burns to children and adults.  
A. #12 x 1⁵⁄₈" screws  
B. Anti-tip bracket  
1. Remove the anti-tip bracket that is taped in the storage  
Wall Mounting  
drawer.  
2. Determine which mounting method to use: floor or wall.  
If you have a stone or masonry floor you can use the wall  
mounting method.  
3. Determine and mark the edge of the range in the cutout  
space. The mounting bracket can be installed on either the  
left side or right side of the cutout. Position mounting bracket  
in cutout so that right (or left) edge of the bracket is  
A
B
⁹⁄₁₆" (14.5 mm) from the marked edge of the range, as shown.  
A
B
A. #12 x 1⁵⁄₈" screws  
B. Anti-tip bracket  
5. Using the Phillips screwdriver, mount anti-tip bracket to the  
wall or floor with the two #12 x 1⁵⁄₈" screws provided.  
C
A. Anti-tip bracket  
B. Mark edge of range.  
C. ⁹⁄₁₆" (14.5 mm)  
4. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket  
holes of the determined mounting method. See the following  
illustrations.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Connection  
Power Supply Cord  
Direct Wire  
WARNING  
WARNING  
Electrical Shock Hazard  
Disconnect power before servicing.  
Use a new 40 amp power supply cord.  
Plug into a grounded outlet.  
Electrical Shock Hazard  
Disconnect power before servicing.  
Use 8 gauge copper or 6 gauge aluminum wire.  
Electrically ground range.  
Failure to follow these instructions can result in death,  
fire, or electrical shock.  
Failure to follow these instructions can result in death,  
fire, or electrical shock.  
1. Disconnect power.  
4. Add strain relief.  
2. Use Phillips screwdriver to remove the terminal block cover  
Style 1: Power supply cord strain relief  
screw located on the back of the range.  
Assemble a UL listed strain relief in the opening.  
A
B
A. UL listed strain relief - large opening  
B. Small opening  
Feed the power supply cord through the strain relief on  
the cord/conduit plate on bottom of range. Allow enough  
slack to easily attach the wiring to the terminal block.  
3. Remove plastic tag holding three #10-32 hex nuts from the  
middle post of the terminal block.  
Tighten strain relief screw against the power supply cord.  
Style 2: Direct wire strain relief  
Use Phillips screwdriver to remove screws and rotate/  
conduit plate 180º.  
B
A
A. Large opening  
B. Small opening  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Position cord/conduit plate as shown in the following  
illustration.  
Electrical Connection Options  
If your home has:  
And you will be Go to Section:  
connecting to:  
4-wire receptacle  
(NEMA type 14-50R)  
A UL listed,  
250-volt  
4-wire connection:  
Power supply cord  
B
minimum,  
40-amp, range  
power supply  
cord  
A
A. Small opening  
B. Large opening  
Replace cord/conduit plate and insert screws.  
4-wire direct  
A fused  
4-wire connection:  
Direct wire  
disconnect or  
circuit breaker  
box  
5"  
(12.7 cm)  
3-wire receptacle  
(NEMA type 10-50R)  
A UL listed,  
250-volt  
3-wire connection:  
Power supply cord  
minimum,  
40-amp, range  
power supply  
cord  
3-wire direct  
A fused  
3-wire connection:  
Direct wire  
B
A
1"  
disconnect or  
circuit breaker  
box  
(2.5 cm)  
A. Small opening  
B. Large opening  
3"  
(7.6 cm)  
Assemble a UL listed conduit connector in the opening.  
4-wire connection: Power Supply Cord  
Use this method for:  
New branch-circuit installations (1996 NEC)  
Mobile homes  
Recreational vehicles  
In an area where local codes prohibit grounding through the  
neutral  
A
C
1. Part of metal ground strap must be cut out and removed.  
B
A. Removable retaining nut - small opening  
B. Conduit connector  
C. Large opening  
A
B
C
Feed the flexible conduit through the strain relief, allowing  
enough slack to easily attach wiring to the terminal block.  
Tighten strain relief screw against the flexible conduit.  
A. Metal ground strap  
B. Discard  
C. Ground-link screw  
2. Use Phillips screwdriver to remove the ground-link screw  
from the back of the range. Save the ground-link screw and  
the end of the ground link under the screw.  
5. Replace back panel and screws on rear of range.  
6. Complete installation following instructions for your type of  
electrical connection:  
4-wire (recommended)  
3-wire (if 4-wire is not available)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Feed the power supply cord through the strain relief on the  
cord/conduit plate on bottom of range. Allow enough slack to  
easily attach the wiring to the terminal block.  
3-wire connection: Power Supply Cord  
Use this method only if local codes permit connecting chassis  
ground conductor to neutral wire of power supply cord.  
A
1. Feed the power supply cord through the strain relief on the  
cord/conduit plate on bottom of range. Allow enough slack to  
easily attach the wiring to the terminal block.  
B
A
B
C
E
D
C
A. Terminal block  
B. Ground-link screw  
C. Cord/conduit plate  
E
D
D. Power supply cord wires - large opening  
E. Small opening  
A. Terminal block  
B. Ground-link screw  
C. Cord/conduit plate  
D. Power supply cord wires - large opening  
E. Small opening  
4. Use Phillips screwdriver to connect the green ground wire  
from the power supply cord to the range with the ground-link  
screw. The ground wire must be attached first.  
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the  
center terminal block post with one of the #10-32 hex nuts.  
2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the  
center terminal block post with one of the #10-32 hex nuts.  
A
F
A
E
B
E
C
D
B
D
C
A. #10-32 hex nut  
B. Ground-link screw  
C. Line 1 (black)  
D. Green ground wire  
E. Neutral (center) wire  
F. Line 2 (red)  
A. #10-32 hex nut  
B. Line 1 (black)  
C. Ground-link screw  
D. Neutral (white) wire  
E. Line 2 (red)  
6. Connect line 1 (black) and line 2 (red) wires to the outer  
3. Connect line 1 (black) and line 2 (red) wires to the outer  
terminal block posts with #10-32 hex nuts.  
terminal block posts with #10-32 hex nuts.  
7. Securely tighten hex nuts.  
4. Securely tighten hex nuts.  
NOTE: For power supply cord replacement, only use a power  
cord rated at 250 volts minimum, 40 amps or 50 amps that is  
marked for use with nominal 1³⁄₈" (3.5 cm) diameter  
connection opening, with ring terminals and marked for use  
with ranges.  
NOTE: For power supply cord replacement, only use a power  
cord rated at 250 volts minimum, 40 amps or 50 amps that is  
marked for use with nominal 1³⁄₈" (3.5 cm) diameter  
connection opening, with ring terminals and marked for use  
with ranges.  
8. Replace terminal block access cover.  
5. Replace terminal block access cover.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Pull the conduit through the strain relief on cord/conduit plate  
on bottom of range. Allow enough slack to easily attach  
wiring to the terminal block.  
Direct Wire Installation: Copper or Aluminum Wire  
This range may be connected directly to the fuse disconnect or  
circuit breaker box. Depending on your electrical supply, make  
the required 3-wire or 4-wire connection.  
A
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip  
the insulation back 1" (2.5 cm) from the end of each wire.  
B
1"  
(2.5 cm)  
C
3"  
(7.6 cm)  
G
D
F
E
2. Allow enough slack in the wire to easily attach the wiring  
terminal block.  
A. Terminal block  
E. Neutral (white) wire  
F. Line 1 (black) wire  
G. Bare (green) ground wire  
3. Complete electrical connection according to your type of  
B. Ground-link screw  
C. Cord/conduit plate  
D. Line 2 (red) wire  
electrical supply (4-wire or 3-wire connection).  
4-wire Connection: Direct Wire  
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2  
(red) wires. Loosen (do not remove) the set screw on the front  
of the terminal lug and insert exposed wire end through  
bottom of terminal lugs. Securely tighten set screw to torque  
as shown in the following Bare Wire Torque Specifications  
chart.  
Use this method for:  
New branch-circuit installations (1996 NEC)  
Mobile homes  
Recreational vehicles  
In an area where local codes prohibit grounding through the  
neutral  
A
1. Part of metal ground strap must be cut out and removed.  
B
A
B
C
C
D
E
A. Metal ground strap  
B. Discard  
C. Ground-link screw  
A. Terminal lug  
B. Set screw  
C. Line 1 (black) wire  
D. Neutral (white) wire  
E. Line 2 (red) wire  
2. Use Phillips screwdriver to remove the ground-link screw  
from the back of the range. Save the ground-link screw and  
the end of the ground link under the screw.  
Bare Wire Torque Specifications  
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)  
Wire Awg  
Torque  
8 gauge copper  
25 lbs-in. (2.8 N-m)  
35 lbs-in. (4.0 N-m)  
6 gauge aluminum  
5. Use Phillips screwdriver to connect the bare (green) ground  
wire to the range with the ground-link screw. The ground wire  
must be attached first and must not contact any other  
terminal.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the  
2. Attach terminal lugs to line 1 (black), bare (green) ground, and  
line 2 (red) wires. Loosen (do not remove) the set screw on the  
front of the terminal lug and insert exposed wire end through  
bottom of terminal lugs. Securely tighten set screw to torque  
as shown in the following Bare Wire Torque Specifications  
chart.  
center terminal block post with one of the #10-32 hex nuts.  
G
A
A
B
B
F
D
E
C
C
D
E
A. #10-32 hex nut  
B. Line 1 (black)  
E. Neutral (white) wire  
F. Line 2 (red)  
C. Bare (green) ground wire  
D. Ground-link screw  
G. Terminal lug  
A. Terminal lug  
B. Set screw  
C. Line 1 (black) wire  
D. Bare (green) ground wire  
E. Line 2 (red) wire  
7. Connect line 1 (black) and line 2 (red) wires to the outer  
terminal block posts with #10-32 hex nuts.  
8. Securely tighten hex nuts.  
9. Replace terminal block access cover.  
Bare Wire Torque Specifications  
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)  
3-wire connection: Direct Wire  
Wire Awg  
Torque  
Use this method only if local codes permit connecting ground  
conductor to neutral supply wire.  
8 gauge copper  
25 lbs-in. (2.8 N-m)  
35 lbs-in. (4.0 N-m)  
1. Pull the conduit through the strain relief on cord/conduit plate  
on bottom of range. Allow enough slack to easily attach the  
wiring to the terminal block.  
6 gauge aluminum  
3. Use ³⁄₈" nut driver to connect the bare (green) ground wire to  
the center terminal block post with one of the #10-32 hex  
nuts.  
A
B
F
E
A
C
B
D
F
E
A. Terminal block  
B. Ground-link screw  
C. Cord/conduit plate  
D. Line 2 (red) wire  
E. Bare (green) ground wire  
F. Line 1 (black) wire  
D
C
A. #10-32 hex nut  
B. Line 1 (black)  
D. Bare (green) ground wire  
E. Line 2 (red)  
C. Ground-link screw  
F. Terminal lug  
4. Connect line 1 (black) and line 2 (red) wires to the outer  
terminal block posts with #10-32 hex nuts.  
5. Securely tighten hex nuts.  
6. Replace terminal block access cover.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Verify Anti-Tip Bracket Location  
Complete Installation  
1. On models with a storage drawer, pull drawer open to first  
stop position. Lift front of drawer to clear white wheels in  
drawer guides. Remove drawer and set it aside on a covered  
surface.  
1. Check that all parts are now installed. If there is an extra part,  
go back through the steps to see which step was skipped.  
2. Check that you have all of your tools.  
3. Dispose of/recycle all packaging materials.  
4. Check that the range is level. See “Level Range.”  
5. Use a mild solution of liquid household cleaner and warm  
water to remove waxy residue caused by shipping material.  
Dry thoroughly with a soft cloth. For more information, read  
the “Range Care” section of the Use and Care Guide.  
On models with a warming drawer, the rear leg cannot be  
seen by removing the warming drawer. It will be necessary to  
view the rear foot from outside the range.  
6. Read “Range Use” in the range Use and Care Guide.  
7. Plug power cord into appropriate outlet. Slide range into its  
final location. Check that the flexible conduit or power supply  
cord are not bent.  
8. Replace storage drawer (warming drawer on some models).  
9. Turn power on. Turn on surface burners and oven. See the  
Use and Care Guide for specific instruction on range  
operation.  
2. To check that the anti-tip bracket is installed, use a flashlight  
and look underneath the bottom of the range.  
Look for the anti-tip bracket securely attached to floor.  
If range does not operate, check the following:  
Slide range back so rear range foot is under anti-tip  
bracket.  
Household fuse is intact and tight; or circuit breaker has not  
tripped.  
Range is plugged into an outlet.  
Electrical supply is connected.  
See “Troubleshooting” in the Use and Care Guide.  
When the range has been on for 5 minutes, check for heat. If  
range is cold, turn off the range and contact a qualified  
technician.  
If you need Assistance or Service:  
Please reference the “Assistance or Service” section of the Use  
and Care Guide or contact the dealer from whom you purchased  
your range.  
Level Range  
1. Place rack in oven.  
2. Place level on rack and check levelness of range, first side to  
side; then front to back.  
3. If range is not level, pull range forward until rear leveling leg is  
removed from the anti-tip bracket.  
On Ranges Equipped with Storage Drawers:  
Use a ¼" drive ratchet, wrench or pliers to adjust leveling legs  
up or down until the range is level. Push range back into  
position. Check that rear leveling leg is engaged in anti-tip  
bracket.  
On Ranges Equipped with Warming Drawers:  
Use a wrench or pliers to adjust leveling legs up or down until  
the range is level. Push range back into position. Check that  
rear leveling leg is engaged in anti-tip bracket.  
NOTE: Range must be level for satisfactory baking  
performance.  
4. Replace the storage drawer (or warming drawer on some  
models).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Moving the Range  
For direct-wired ranges:  
WARNING  
WARNING  
Electrical Shock Hazard  
Tip Over Hazard  
Disconnect power before servicing.  
A child or adult can tip the range and be killed.  
Connect anti-tip bracket to rear range foot.  
Reconnect the anti-tip bracket, if the range is moved.  
Replace all parts and panels before operating.  
Failure to do so can result in death or electrical shock.  
Failure to follow these instructions can result in death  
or serious burns to children and adults.  
1. Disconnect power.  
2. Slide range forward.  
3. Complete cleaning or maintenance.  
When moving range, slide range onto cardboard or hardboard to  
avoid damaging the floor covering.  
4. To check that anti-tip bracket is installed, use a flashlight and  
look underneath the bottom of the range:  
If removing the range is necessary for cleaning or maintenance:  
Look for the anti-tip bracket securely attached to floor or  
wall.  
For power supply cord-connected ranges:  
1. Slide range forward.  
Slide range back so rear range foot is under anti-tip  
bracket.  
2. Unplug the power supply cord.  
3. Complete cleaning or maintenance.  
4. Plug in power supply cord.  
5. To check that anti-tip bracket is installed, use a flashlight and  
look underneath the bottom of the range:  
Look for the anti-tip bracket securely attached to floor or  
wall.  
Slide range back so rear range foot is under anti-tip  
bracket.  
5. Check that range is level.  
6. Reconnect power.  
6. Check that range is level.  
W10258095A  
© 2009. Whirlpool Corporation.  
All rights reserved.  
4/09  
Printed in U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

West Bend Microwave Oven AG028PLV User Manual
West Bend Slow Cooker WBSCRD6QT User Manual
Whirlpool Clothes Dryer 240 volt User Manual
White Outdoor Lawn Mower Z 165 User Manual
Woodstock Recording Equipment d3012 3016 User Manual
Zanussi Clothes Dryer TD526 User Manual
Zanussi Refrigerator ZBB6286 User Manual
Zanussi Washer ZWF 1020W User Manual
Zenoah Brush Cutter BC2311LE, BC2611LE, BC2611WE, BC3501LE, BC3501WE, BC4501WE User Manual
Z Microsystems Network Card Z MPU User Manual