INSTALLATION INSTRUCTIONS  
FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS  
Table of Contents  
RANGE SAFETY ......................................................................... 2  
INSTALLATION REQUIREMENTS............................................ 3  
Tools and Parts........................................................................ 3  
Location Requirements ........................................................... 3  
Electrical Requirements........................................................... 5  
INSTALLATION INSTRUCTIONS.............................................. 6  
Unpack Range......................................................................... 6  
Adjust Leveling Legs................................................................ 6  
Install Anti-Tip Bracket ............................................................ 7  
Electrical Connection............................................................... 8  
Verify Anti-Tip Bracket Location............................................ 13  
Level Range........................................................................... 14  
Complete Installation............................................................. 14  
Moving the Range.................................................................. 15  
IMPORTANT:  
Save for local electrical inspector's use.  
W10270322A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION REQUIREMENTS  
Tools and Parts  
Location Requirements  
Gather the required tools and parts before starting installation.  
Read and follow the instructions provided with any tools listed  
here.  
Tools needed  
IMPORTANT: Observe all governing codes and ordinances.  
It is the installer’s responsibility to comply with installation  
clearances specified on the model/serial number rating label.  
The model/serial number rating label is located on the bottom  
right front of the toe kick plate.  
Tape measure  
Level  
Wrench or pliers  
³⁄₈" nut driver  
The range should be located for convenient use in the kitchen.  
To eliminate the risk of burns or fire by reaching over heated  
surface units, cabinet storage space located above the  
surface units should be avoided. If cabinet storage is to be  
provided, the risk can be reduced by installing a range hood  
that projects horizontally a minimum of 5" (12.7 cm) beyond  
the bottom of the cabinets.  
Phillips screwdriver  
Flat-blade screwdriver  
Hand or electric drill  
¹⁄₈" (3.2 mm) drill bit  
Parts supplied  
Check that all parts are included.  
Cabinet opening dimensions that are shown must be used.  
Given dimensions are minimum clearances.  
3 - 10–32 hex nuts (attached to terminal block)  
3 - Terminal lugs  
The floor anti-tip bracket must be installed. To install the anti-  
tip bracket shipped with the range, see “Install Anti-Tip  
Bracket” section.  
Oven racks  
2 - #12 x 1⁵⁄₈" screws (for mounting anti-tip bracket)  
Grounded electrical supply is required. See “Electrical  
Requirements” section.  
Anti-tip bracket (taped inside upper oven with literature  
package)  
IMPORTANT: To avoid damage to your cabinets, check with your  
builder or cabinet supplier to make sure that the materials used  
will not discolor, delaminate or sustain other damage. This range  
has been designed in accordance with the requirements of UL  
and CSA International and complies with the maximum allowable  
wood cabinet temperatures of 194°F (90°C).  
Anti-tip bracket must be securely mounted to back wall or  
floor. Thickness of floor may require longer screws to anchor  
bracket to subfloor. Longer screws are available from your  
local hardware store.  
Parts needed  
If using a power supply cord:  
Mobile Home - Additional Installation Requirements  
A UL listed power supply cord kit marked for use with ranges.  
The cord should be rated at 250 volts minimum, 40 amps or  
50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm)  
diameter connection opening and must end in ring terminals  
or open-end spade terminals with upturned ends.  
The installation of this range must conform to the Manufactured  
Home Construction and Safety Standard, Title 24 CFR, Part 3280  
(formerly the Federal Standard for Mobile Home Construction and  
Safety, Title 24, HUD Part 280). When such standard is not  
applicable, the Standard for Manufactured Home Installations,  
ANSI A225.1/NFPA 501A or with local codes.  
A UL listed strain relief.  
Mobile home installations require:  
Check local codes. Check existing electrical supply. See  
“Electrical Requirements” section.  
It is recommended that all electrical connections be made by a  
licensed, qualified electrical installer.  
When this range is installed in a mobile home, it must be  
secured to the floor during transit. Any method of securing the  
range is adequate as long as it conforms to the standards  
listed above.  
Four-wire power supply cord or cable must be used in a  
mobile home installation. The appliance wiring will need to be  
revised. See “Electrical Connection” section.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Dimensions  
Cabinet Dimensions  
Cabinet opening dimensions shown are for 25" (64.0 cm)  
countertop depth, 24" (61.0 cm) base cabinet depth and  
36" (91.4 cm) countertop height.  
IMPORTANT: If installing a range hood or microwave hood  
combination above the range, follow the range hood or  
microwave hood combination installation instructions for  
dimensional clearances above the cooktop surface.  
A freestanding range may be installed next to combustible walls  
with zero clearance.  
A
A
B
C
C
D
E*  
G
D
F
B
A. 46⁷⁄₈" (119.9 cm)  
C. 35⁷⁄₈" (91.4 cm)  
D. 29⁷⁄₈" (75.9 cm)  
E. 26⁵⁄₁₆" - 27¼" (66.8 - 69.2 cm)*  
E
B. Model/serial number rating  
label (located on bottom right  
front of the toe kick plate)  
*Excludes handle. Dimension given is from wall to front of oven  
door and will vary based on electric outlet receptacle installation.  
H
A. 13" (33 cm) upper cabinet  
depth  
B. 30" (76.2 cm) min. opening  
width  
C. For minimum clearance to the  
top of the cooktop,  
see NOTE.  
D. 30" (76.2 cm) min. opening  
width  
F. 3-wire shaded area -  
7" (17.8 cm) min. from left side  
cabinet, 5¾" (14.6 cm) max.  
from floor, 6" (15.2 cm) max.  
width*  
G. 4-wire shaded area -  
10" (25.4 cm) min. from right  
side cabinet, 5¾" (14.6 cm)  
max. from floor, 6" (15.2 cm)  
max. width*  
E. Cabinet door or hinge should  
not extend into cutout.  
H. 1½" (3.8 cm) min. from floor if  
using a flush mount outlet.  
*Nothing located in shaded areas can extend more than 1½"  
(3.8 cm) from wall or range will not slide all the way back.  
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal  
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant  
millboard covered with not less than No. 28 MSG sheet steel,  
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or  
0.020" (0.5 mm) copper.  
30" (76.2 cm) minimum clearance between the top of the cooking  
platform and the bottom of an uncovered wood or metal cabinet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Requirements  
If codes permit and a separate ground wire is used, it is  
If connecting to a 4-wire system:  
recommended that a qualified electrical installer determine that  
the ground path and wire gauge are in accordance with local  
codes.  
This range is manufactured with the ground connected to the  
neutral by a link. The ground must be revised so the green ground  
wire of the 4-wire power supply cord is connected to the cabinet.  
See “Electrical Connection.”  
Do not use an extension cord.  
Grounding through the neutral conductor is prohibited for new  
branch-circuit installations (1996 NEC); mobile homes; and  
recreational vehicles, or an area where local codes prohibit  
grounding through the neutral conductor.  
When a 4-wire receptacle of NEMA Type 14-50R is used, a  
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power  
supply cord (pigtail) must be used. This cord contains 4 copper  
conductors with ring terminals or open-end spade terminals with  
upturned ends, terminating in a NEMA Type 14-50P plug on the  
supply end.  
Be sure that the electrical connection and wire size are adequate  
and in conformance with the National Electrical Code, ANSI/NFPA  
70-latest edition and all local codes and ordinances.  
A copy of the above code standards can be obtained from:  
National Fire Protection Association  
One Batterymarch Park  
Quincy, MA 02269.  
WARNING: Improper connection of the equipment-grounding  
conductor can result in a risk of electric shock. Check with a  
qualified electrician or service technician if you are in doubt as to  
whether the appliance is properly grounded. Do not modify the  
power supply cord plug. If it will not fit the outlet, have a proper  
outlet installed by a qualified electrician.  
The fourth (grounding) conductor must be identified by a green or  
green/yellow cover and the neutral conductor by a white cover.  
Cord should be Type SRD or SRDT with a UL listed strain relief  
and be at least 4 ft (1.22 m) long.  
Electrical Connection  
To properly install your range, you must determine the type of  
electrical connection you will be using and follow the instructions  
provided for it here.  
Range must be connected to the proper electrical voltage and  
frequency as specified on the model/serial number rating  
label. The model/serial number rating label is located on the  
bottom right front of the toe kick plate. Refer to the figures in  
the “Product Dimensions” section of the “Location  
Requirements” section.  
4-wire receptacle (14-50R)  
The minimum conductor sized for the copper 4-wire power  
cord are:  
40-amp circuit  
This range is manufactured with the neutral terminal  
connected to the cabinet. Use a 3-wire, UL listed, 40- or  
50-amp power supply cord (pigtail) (see following Range  
Rating chart). If local codes do not permit ground through the  
neutral, use a 4-wire power supply cord rated at 250 volts,  
40 or 50 amps and investigated for use with ranges.  
2 No.-8 conductors  
1 No.-10 white neutral  
1 No.-8 green grounding  
If connecting to a 3-wire system:  
Local codes may permit the use of a UL listed, 3-wire, 250-volt,  
40- or 50-amp range power supply cord (pigtail). This cord  
contains 3 copper conductors with ring terminals or open-end  
spade terminals with upturned ends, terminating in a NEMA Type  
10-50P plug on the supply end. Connectors on the appliance end  
must be provided at the point the power supply cord enters the  
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.  
Range Rating*  
Specified Rating of  
Power Supply Cord Kit  
and Circuit Protection  
120/240 Volts  
120/208 Volts  
Amps  
8.8 - 16.5 KW  
16.6 - 22.5 KW  
7.8 - 12.5 KW  
12.6 - 18.5 KW  
40 or 50**  
50  
*The NEC calculated load is less than the total connected load  
listed on the model/serial number rating label.  
**If connecting to a 50-amp circuit, use a 50-amp rated cord with  
kit. For 50-amp rated cord kits, use kits that specify use with a  
nominal 1³⁄₈" (34.9 mm) diameter connection opening.  
3-wire receptacle (10-50R)  
A circuit breaker is recommended.  
The range can be connected directly to the circuit breaker box  
(or fused disconnect) through flexible or nonmetallic sheathed,  
copper or aluminum cable. See “Electrical Connection.”  
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that  
the range can be moved if servicing is ever necessary.  
A UL listed conduit connector must be provided at each end  
of the power supply cable (at the range and at the junction  
box).  
Wire sizes and connections must conform with the rating of  
the range.  
The wiring diagram is located on the back of the range or  
inside the storage drawer in a clear plastic bag.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Unpack Range  
Adjust Leveling Legs  
1. If range height adjustment is necessary, use a wrench or pliers  
to loosen the 4 leveling legs.  
WARNING  
Excessive Weight Hazard  
This may be done with the range on its back or with the range  
supported on 2 legs after the range has been placed back to a  
standing position.  
Use two or more people to move and install range.  
Failure to do so can result in back or other injury.  
NOTE: To place range back up into a standing position, put a  
sheet of cardboard or hardboard in front of range. Using 2 or  
more people, stand range back up onto the cardboard or  
hardboard.  
1. Remove shipping materials, tape and film from the range.  
Keep cardboard bottom under range.  
2. Remove oven racks and parts package from inside oven.  
3. To place range on its back, take 4 cardboard corners from the  
carton. Stack one cardboard corner on top of another. Repeat  
with the other 2 corners. Place them lengthwise on the floor  
behind the range to support the range when it is laid on its  
back.  
WARNING  
4. Using 2 or more people, firmly grasp the range and gently lay  
it on its back on the cardboard corners.  
5. Pull cardboard bottom firmly to remove.  
6. Use an adjustable wrench to loosen the leveling legs.  
Tip Over Hazard  
A child or adult can tip the range and be killed.  
Connect anti-tip bracket to rear range foot.  
Reconnect the anti-tip bracket, if the range is moved.  
7. Place cardboard or hardboard in front of range. Using 2 or  
more people, stand range back up onto cardboard or  
hardboard.  
Failure to follow these instructions can result in death  
or serious burns to children and adults.  
2. Adjust the leveling legs to the correct height. Leveling legs can  
be loosened to add up to a maximum of 1" (2.5 cm). A  
minimum of ³⁄₁₆" (5.0 mm) is needed to engage the anti-tip  
bracket.  
NOTE: If height adjustment is made when range is standing,  
tilt the range back to adjust the front legs, then tilt forward to  
adjust the rear legs.  
3. When the range is at the correct height, check that there is  
adequate clearance under the range for the anti-tip bracket.  
Before sliding range into its final location, check that the anti-  
tip bracket will slide under the range and onto the rear leveling  
leg prior to anti-tip bracket installation.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install Anti-Tip Bracket  
1. Remove the anti-tip bracket that is taped inside the upper  
Floor Mounting  
oven with the package containing literature.  
A
B
2. Determine which mounting method to use: floor or wall.  
If you have a stone or masonry floor you can use the wall  
mounting method.  
3. Determine and mark edge of range in the cutout space. The  
mounting bracket can be installed on either the left side or  
right side of the cutout. Position mounting bracket in cutout so  
that right (or left) edge of the bracket is ¹⁵⁄₁₆" (2.4 cm) from the  
marked edge of the range, as shown.  
A
B
A. #12 x 1⁵⁄₈" screws  
B. Anti-tip bracket  
Wall Mounting  
C
A. Anti-tip bracket  
B. Mark edge of range.  
C. ¹⁵⁄₁₆" (2.4 cm)  
A
B
4. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket  
holes of the determined mounting method. See the following.  
A. #12 x 1⁵⁄₈" screws  
B. Anti-tip bracket  
5. Using the Phillips screwdriver, mount anti-tip bracket to the  
wall or floor with the two #12 x 1⁵⁄₈" screws provided.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Connection - U.S.A. Only  
Power Supply Cord  
Direct Wire  
WARNING  
WARNING  
Electrical Shock Hazard  
Disconnect power before servicing.  
Use 8 gauge copper or 6 gauge aluminum wire.  
Electrically ground range.  
Electrical Shock Hazard  
Disconnect power before servicing.  
Use a new 40 amp power supply cord.  
Plug into a grounded outlet.  
Failure to follow these instructions can result in death,  
fire, or electrical shock.  
Failure to follow these instructions can result in death,  
fire, or electrical shock.  
1. Disconnect power.  
Style 1: Power supply cord strain relief  
2. Use Phillips screwdriver to remove the terminal block cover  
screw located on the back of the range. Pull cover down and  
toward you to remove cover.  
Assemble a UL listed strain relief in the opening.  
A
A. UL listed strain relief  
3. Remove plastic tag holding three 10-32 hex nuts from the  
Feed the power supply cord through the strain relief in the  
cord/conduit plate on bottom of range. Allow enough  
slack to easily attach the wiring to the terminal block.  
middle post of the terminal block.  
Tighten strain relief screw against the power supply cord.  
4. Add strain relief.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Style 2: Direct wire strain relief  
Assemble a UL listed conduit connector in the opening.  
Use Phillips screwdriver to remove screws and slide  
cord/conduit plate down and out.  
A
B
Position cord/conduit plate as shown in the following  
illustration.  
A. Removable retaining nut  
B. Strain relief  
Feed the flexible conduit through the strain relief, allowing  
enough slack to easily attach wiring to the terminal block.  
Tighten strain relief screw against the flexible conduit.  
Replace cord/conduit plate and insert screws.  
5. Replace back panel and screws on rear of range.  
6. Complete installation following instructions for your type of  
electrical connection:  
4-wire (recommended)  
3-wire (if 4-wire is not available)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Connection Options  
3. Feed the power supply cord through the strain relief in the  
cord/conduit plate on bottom of range. Allow enough slack to  
easily attach the wiring to the terminal block.  
If your home has:  
And you will be  
connecting to:  
Go to Section:  
4-wire receptacle  
(NEMA type 14-50R)  
A UL listed,  
250-volt  
4-wire connection:  
Power supply cord  
A
minimum,  
40-amp, range  
power supply  
cord  
B
4-wire direct  
A fused  
4-wire connection:  
Direct wire  
disconnect or  
circuit breaker  
box  
5"  
(12.7 cm)  
3-wire receptacle  
(NEMA type 10-50R)  
A UL listed,  
250-volt  
3-wire connection:  
Power supply cord  
minimum,  
40-amp, range  
power supply  
cord  
C
D
3-wire direct  
A fused  
3-wire connection:  
Direct wire  
disconnect or  
circuit breaker  
box  
1"  
A. Terminal block  
(2.5 cm)  
B. Ground-link screw  
C. Cord/conduit plate  
D. Power supply cord wires  
3"  
(7.6 cm)  
4. Use Phillips screwdriver to connect the green ground wire  
from the power supply cord to the range with the ground-link  
screw. The ground wire must be attached first.  
4-wire connection: Power Supply Cord  
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the  
Use this method for:  
center terminal block post with one of the 10–32 hex nuts.  
New branch-circuit installations (1996 NEC)  
Mobile homes  
Recreational vehicles  
In an area where local codes prohibit grounding through the  
neutral  
A
F
1. Part of metal ground strap must be cut out and removed.  
B
E
C
A
B
C
D
A. 10–32 hex nut  
B. Ground-link screw  
C. Line 1 (black)  
D. Green ground wire  
E. Neutral (center) wire  
F. Line 2 (red)  
A. Metal ground strap  
B. Discard  
C. Ground-link screw  
6. Connect line 1 (black) and line 2 (red) wires to the outer  
terminal block posts with 10-32 hex nuts.  
2. Use Phillips screwdriver to remove the ground-link screw from  
the back of the range. Save the ground link screw and the end  
of the ground-link under the screw.  
7. Securely tighten hex nuts.  
NOTE: For power supply cord replacement, only use a power  
cord rated at 250 volts minimum, 40 amps or 50 amps that is  
marked for use with nominal 1³⁄₈" (3.5 cm) diameter  
connection opening, with ring terminals and marked for use  
with ranges.  
8. Replace terminal block access cover.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Securely tighten hex nuts.  
3-wire connection: Power Supply Cord  
NOTE: For power supply cord replacement, only use a power  
cord rated at 250 volts minimum, 40 amps or 50 amps that is  
marked for use with nominal 1³⁄₈" (3.5 cm) diameter  
connection opening, with ring terminals and marked for use  
with ranges.  
Use this method only if local codes permit connecting chassis  
ground conductor to neutral wire of power supply cord.  
1. Feed the power supply cord through the strain relief in the  
cord/conduit plate on bottom of range. Allow enough slack to  
easily attach the wiring to the terminal block.  
5. Replace terminal block access cover.  
Direct Wire Installation: Copper or Aluminum Wire  
This range may be connected directly to the fuse disconnect or  
circuit breaker box. Depending on your electrical supply, make the  
required 3-wire or 4-wire connection.  
A
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip  
the insulation back 1" (2.5 cm) from the end of each wire.  
1"  
(2.5 cm)  
B
3"  
(7.6 cm)  
2. Allow enough slack in the wire to easily attach the wiring  
terminal block.  
C
3. Complete electrical connection according to your type of  
D
electrical supply (4-wire or 3-wire connection).  
4-wire Connection: Direct Wire  
A. Terminal block  
Use this method for:  
B. Ground-link screw  
C. Cord/conduit plate  
D. Power supply cord wires  
New branch-circuit installations (1996 NEC)  
Mobile homes  
2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the  
Recreational vehicles  
center terminal block post with one of the 10–32 hex nuts.  
In an area where local codes prohibit grounding through the  
neutral  
1. Part of metal ground strap must be cut out and removed.  
A
E
A
B
C
D
B
A. Metal ground strap  
B. Discard  
C
C. Ground-link screw  
A. 10–32 hex nut  
B. Line 1 (black)  
C. Ground-link screw  
D. Neutral (white) wire  
E. Line 2 (red)  
2. Use Phillips screwdriver to remove the ground-link screw from  
the back of the range. Save the ground-link screw and the end  
of the ground link under the screw.  
3. Connect line 1 (black) and line 2 (red) wires to the outer  
terminal block posts with 10-32 hex nuts.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Pull the conduit through the strain relief on cord/conduit plate  
on bottom of range. Allow enough slack to easily attach wiring  
to the terminal block.  
Bare Wire Torque Specifications  
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)  
Wire Awg  
Torque  
8 gauge copper  
25 lbs-in. (2.8 N-m)  
35 lbs-in. (4.0 N-m)  
A
B
C
6 gauge aluminum  
5. Use Phillips screwdriver to connect the bare (green) ground  
wire to the range with the ground-link screw. The ground wire  
must be attached first and must not contact any other  
terminal.  
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the  
center terminal block post with one of the 10–32 hex nuts.  
G
A
G
D
B
F
E
F
A. Terminal block  
E. Neutral (white) wire  
F. Line 1 (black) wire  
G. Bare (green) ground wire  
B. Ground-link screw  
C. Cord/conduit plate  
D. Line 2 (red) wire  
D
E
C
4. Attach terminal lugs to line 1 (black), neutral (white), and line  
2 (red) wires. Loosen (do not remove) the setscrew on the front  
of the terminal lug and insert exposed wire end through  
bottom of terminal lugs. Securely tighten setscrew to  
A. 10–32 hex nut  
B. Line 1 (black)  
C. Bare (green) ground wire  
D. Ground-link screw  
E. Neutral (white) wire  
F. Line 2 (red)  
G. Terminal lug  
XX lbs-in. torque. See Bare Wire Torque Specifications chart.  
7. Connect line 1 (black) and line 2 (red) wires to the outer  
A
terminal block posts with 10-32 hex nuts.  
8. Securely tighten hex nuts.  
9. Replace terminal block access cover.  
B
C
D
E
A. Terminal lug  
B. Setscrew  
C. Line 1 (black) wire  
D. Neutral (white) wire  
E. Line 2 (red) wire  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bare Wire Torque Specifications  
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)  
3-wire connection: Direct Wire  
Wire Awg  
Torque  
Use this method only if local codes permit connecting ground  
conductor to neutral supply wire.  
1. Pull the conduit through the hole and conduit plate on bottom  
of range. Allow enough slack to easily attach the wiring to the  
terminal block.  
8 gauge copper  
25 lbs-in. (2.8 N-m)  
35 lbs-in. (4.0 N-m)  
6 gauge aluminum  
3. Use ³⁄₈" nut driver to connect the bare (green) ground wire to  
the center terminal block post with one of the 10–32 hex nuts.  
A
F
E
A
B
B
C
D
C
A. 10–32 hex nut  
B. Line 1 (black)  
C. Ground-link screw  
D. Bare (green) ground wire  
E. Line 2 (red)  
F. Terminal lug  
D
F
E
A. Terminal block  
B. Ground-link screw  
C. Cord/conduit plate  
D. Line 2 (red) wire  
E. Bare (green) ground wire  
F. Line 1 (black) wire  
4. Connect line 1 (black) and line 2 (red) wires to the outer  
terminal block posts with 10-32 hex nuts.  
5. Securely tighten hex nuts.  
6. Replace terminal block access cover.  
2. Attach terminal lugs to line 1 (black), bare (green) ground, and  
line 2 (red) wires. Loosen (do not remove) the setscrew on the  
front of the terminal lug and insert exposed wire end through  
bottom of terminal lugs. Securely tighten setscrew to XX lbs-  
in. torque. See Bare Wire Torque Specifications chart.  
Verify Anti-Tip Bracket Location  
1. Make sure the anti-tip bracket is installed.  
Look for the anti-tip bracket securely attached to floor or  
wall.  
A
2. If not direct wired, plug power cord into appropriate outlet.  
3. Slide range back so rear range foot is engaged with anti-tip  
bracket. Check that the flexible conduit or power supply cord  
is not bent.  
B
C
D
E
A. Terminal lug  
B. Setscrew  
C. Line 1 (black) wire  
D. Bare (green) ground wire  
E. Line 2 (red) wire  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Level Range  
Complete Installation  
1. Place oven rack in oven.  
1. Check that all parts are now installed. If there is an extra part,  
go back through the steps to see which step was skipped.  
2. Check that you have all of your tools.  
2. Place level on oven rack and check levelness of range, first  
side to side; then front to back.  
3. Dispose of/recycle all packaging materials.  
4. Check that the range is level. See “Level Range.”  
5. Use a mild solution of liquid household cleaner and warm  
water to remove waxy residue caused by shipping material.  
Dry thoroughly with a soft cloth. For more information, read  
the “Range Care” section of the Use and Care Guide.  
6. Read the range Use and Care Guide.  
7. Turn power on. Turn on surface burners and oven. See the  
Use and Care Guide for specific instruction on range  
operation.  
3. If range is not level, pull range forward until rear leveling leg is  
removed from the anti-tip bracket.  
4. Use wrench to adjust leveling legs up or down until range is  
If range does not operate, check the following:  
level. Push range back into position.  
Household fuse is intact and tight; or circuit breaker has not  
tripped.  
5. Check that rear leveling leg is engaged in anti-tip bracket.  
NOTE: Range must be level for satisfactory baking performance.  
Range is plugged into an outlet.  
Electrical supply is connected.  
See “Troubleshooting” in the Use and Care Guide.  
When the range has been on for 5 minutes, check for heat. If  
range is cold, turn off the range and contact a qualified  
technician.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Moving the Range  
For direct-wired ranges:  
WARNING  
WARNING  
Electrical Shock Hazard  
Tip Over Hazard  
Disconnect power before servicing.  
A child or adult can tip the range and be killed.  
Connect anti-tip bracket to rear range foot.  
Reconnect the anti-tip bracket, if the range is moved.  
Replace all parts and panels before operating.  
Failure to do so can result in death or electrical shock.  
Failure to follow these instructions can result in death  
or serious burns to children and adults.  
1. Disconnect power.  
2. Slide range forward.  
3. Complete cleaning or maintenance.  
When moving range, slide range onto cardboard or hardboard to  
avoid damaging the floor covering.  
4. To check that anti-tip bracket is installed, use a flashlight and  
look underneath the bottom of the range:  
If removing the range is necessary for cleaning or maintenance:  
Look for the anti-tip bracket securely attached to floor or  
wall.  
For power supply cord-connected ranges:  
1. Slide range forward.  
Slide range back so rear range foot is under anti-tip  
bracket.  
2. Unplug the power supply cord.  
3. Complete cleaning or maintenance.  
4. Plug in power supply cord.  
5. To check that anti-tip bracket is installed, use a flashlight and  
look underneath the bottom of the range:  
Look for the anti-tip bracket securely attached to floor or  
wall.  
Slide range back so rear range foot is under anti-tip  
bracket.  
5. Check that range is level.  
6. Reconnect power.  
6. Check that range is level.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
W10270322A  
© 2009. Whirlpool Corporation.  
All rights reserved.  
5/09  
Printed in U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym 831157913 User Manual
Well Traveled Living Patio Heater LIP 10A TGG LPG SP User Manual
Wenger Watch TerraGraph User Manual
Western Digital Computer Drive WD20NPVX User Manual
Westinghouse Intercom System WHDBI 5C User Manual
Whirlpool Cooktop WCC31430AB User Manual
Whistler Radar Detector 1788 User Manual
White Rodgers Fan 1D51 User Manual
Zanussi Range GCF5621 User Manual
Zenoah Brush Cutter BC2000 User Manual