Western Telematic Network Card SRM 100 User Manual

WTI P a r t No .: 1 3 0 5 1  
Re v . D  
S R M -1 0 0  
Secure Rack Modem  
Fir m w a r e Ve r s io n 1 .1 3 a n d Hig h e r  
U s e r ' s Gu i d e  
5 St e r lin g  
(9 4 9 ) 5 8 6 -9 9 5 0  
Fa x : (9 4 9 ) 5 8 3 -9 5 1 4  
Ir v in e  
Ca lif o r n ia 9 2 6 1 8 -2 5 1 7  
To ll Fr e e : 1 -8 0 0 -8 5 4 -7 2 2 6  
h t t p :/ / w w w .w t i.c o m  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Table of Contents  
7. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1  
7.1. SRM Operating Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1  
7.2. Password Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1  
7.2.1. The SystemPassword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2  
7.2.2. The Console Port Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2  
7.2.3. User Pass words . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2  
7.2.4. Dial Back Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3  
7.2.5. Pass word on Dial Back. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3  
7.3. Suppressing the Confirmation Prompt . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4  
7.4. Dialing Out from the Modem Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4  
7.5. Viewing the Audit Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5  
7.6. The Utilities Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7  
7.6.1. Zero All Activity Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7  
7.6.2. De lete Audit Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7  
7.6.3. De lete En tire Pass word Di rec tory . . . . . . . . . . . . . . . . . . . . . . . . 7-7  
7.6.4. DefaultParameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8  
7.6.5. Send Test Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8  
7.6.6. Upload Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8  
7.6.7. Download Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9  
7.6.8. Pass-Through Mode (Console-Modem) . . . . . . . . . . . . . . . . . . . . . 7-9  
8. Saving and Restoring Parameters and Password Directory . . . . . . . . . . . . . . . . 8-1  
Appendices:  
A. Interface Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1  
A.1. Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1  
A.2. Modem Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1  
B. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-2  
C. Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-3  
Lis t o f Fig u r e s  
2.1. Front Panel (Not to Scale) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1  
2.2. Back Panel (DC Version Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2  
3.1. The SRM-100 Help Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3  
4.1. Terminal Block Assembly and Grounding Screw (DC Units Only). . . . . . . . . . . . . 4-2  
5.1. The SRM-100 Help Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2  
5.2. The General Parameters Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3  
5.3. The Modem Parameters Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6  
6.1. The Edit Password Directory Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1  
6.2. The Edit/Delete Name/Password Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
6.3. The Password Directory (Sample Data Shown) . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
7.1. The Audit Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5  
7.2. The Utilities Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7  
A.1. Console Port Interface (DTE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1  
A.2. Modem Port Interface (DCE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 . In t r o d u c t io n  
The SRM-100 Secure Rack Modem is designed for applications that require secure, dial-up  
access to console ports on rack mounted equipment. WTI's Secure Rack Modem can recognize  
up to 100 passwords, track activity for each password and create a log record of successful  
and/or unsuccessful access attempts.  
P a s s w o r d P r o t e c t e d Ac c e s s  
Up to 100 User Passwords can be stored in the SRM's non-volatile memory. Each User  
Password can be assigned a user name for easy reference, and an optional Dial Back number  
which instructs the unit to call the user at a predefined number before allowing access. A  
separate System Password restricts access to the SRM command mode, this allows the system  
administrator to contact the unit via modem in order to change parameters or check access  
activity. Access to the SRM Command Mode via the Console Port can also be password  
protected.  
Ac c e s s Ac t iv it y Lo g s  
The SRM-100 provides two convenient ways to track access activity; the Audit Log and the  
Password Directory. The Audit Log lists the 100 most recent connection attempts, including  
the time, date, password entered, port used, call duration, and reason for disconnect. The  
Password Directory displays user names, passwords and dial back numbers, and counts use of  
each individual password. The Audit Log and Password Directory can only be viewed by the  
System Administrator; callers who log on with a User Password are not allowed to view these  
screens.  
Th r e e Dif f e r e n t Op e r a t in g Mo d e s  
The SRM-100 provides three distinct operating modes; the User Mode, the Command Mode,  
and the Unsecured Mode.  
User Mode: Provides password protected access to the secure device connected to the  
SRM's serial modem port.  
Command Mode: Provides password protected access to the SRM Command Menus,  
which are used to define passwords and select configuration parameters.  
Unsecured Mode: When this mode is activated, the SRM will function similar to an  
unsecured modem; callers are allowed to access the secure device without entering a  
password.  
1 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Introduction  
Fe a t u r e s  
Password Protected Command Mode  
Recognizes Up to 100 User-Defined Passwords  
Tracks Access Attempts and Password Activity  
Requires Only One 19 Inch Rack Unit.  
Filtered, Surge Protected Power Supply.  
AC and -48 Volts DC Powered Versions.  
Ty p o g r a p h ic Co n v e n t io n s  
Throughout this manual, typefaces and characters have been used to denote the following:  
COURIER FONT Indicates characters typed on the keyboard. For example, /H or /G.  
[Bold Font]  
Text set in bold face and enclosed in square brackets, indicates a specific  
key. For example, [Enter] or [Esc].  
1 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 . Un it De s c r ip t io n  
2 .1 . Fr o n t P a n e l  
Figure 2.1: Front Panel (Not to Scale)  
ON Indicator: Lights when power is applied to the unit.  
À
Á
RDY: Flashes to indicate that the unit is ready to receive calls or enter the Command  
Mode.  
PASS: Lights when a caller has entered a valid password and has been allowed to access  
the connected device.  
Â
DCD: Lights when DCD is high at the Modem Port.  
RXD: Lights when RXD is high at the serial Modem Port.  
TXD: Lights when TXD is high at the serial Modem Port.  
RTS: Lights when RTS is high at the serial Modem Port.  
CTS: Lights when CTS is high at the serial Modem Port.  
DTR: Lights when DTR is high at the serial Modem Port.  
No te s :  
Ã
Ä
Å
Æ
Ç
È
• Normally, the DTR signal must be high in order for the modem to communicate  
with the secure device. If the DTR signal is low, the SRM-100 will prompt callers  
to enter a password, but will disconnect when a valid User Password is entered.  
• When the Ignore DTR option (See Section 5.3) is enabled, the SRM-100 will  
ignore the DTR signal at the serial Modem Port. This allows the serial Modem  
Port to be connected to a device that does supply a DTR line.  
2 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Table of Contents  
Figure 2.2: Back Panel (DC Version Shown)  
2 .2 . Ba c k P a n e l  
Power Input: (DC Unit Shown) The DC version includes a dual-bus terminal block for  
-48 VDC operation and a ground screw. The AC version includes an IEC-32 inlet for  
connection to a three wire (grounded) power cord (supplied with unit).  
À
Power Switch  
Á
Â
Voltage Selector Switch: (AC Units Only) For selecting 115 VAC or 230 VAC  
operation .  
Default Button: Resets unit to default parameters and erases the Password Directory as  
described in Section 4.4.  
Ã
No te : The default procedure will clear all menu-selected parameters, and erase the  
Password Directory.  
SetUp Switches: Eight DIP switches, which select the default Modem Baud Rate,  
Flow Control, Parity, Rings to Answer, Compression, Speaker (On/Off) and Security  
Mode. For more information on the SetUp Switches, refer to Section 4.3.  
Ä
Å
Console Port: For connection to your PC, terminal, or other device. Allows access to  
Command Mode. DB9, RS232, DTE configuration. Note that the command mode can  
also be accessed via modem as explained in Section 5.1.2.. Appendix A.1 describes the  
Console Port interface.  
Modem Port: For connection to the secure device. The SRM-100 will protect dial-up  
access to this device by requiring a password and/or calling the user back at a predefined  
number. Appendix A.2 describes the Modem Port interface.  
Æ
Ç
Telco Line: For connection to your telecommunications (telephone) line. The RJ11 Jack  
labeled "Wall" or "Line" is used for connection to your telco line. The Jack labeled  
"Phone" is not used.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 . Ge t t in g St a r t e d  
This section provides a brief introduction to the procedures that are used to communicate with  
the SRM unit and access the configuration menus. For more detailed instructions regarding  
installation and configuration, please refer to Sections 4 through 6.  
3 .1 . Ap p ly in g P o w e r t o t h e Un it  
Connect an appropriate power source to the SRM unit. Note that the SRM is available in both  
AC and DC powered versions.  
AC Units: Set the Voltage Selector Switch (located on the SRM back panel) to the  
appropriate voltage. Connect the supplied power cable to the receptacle on the SRM back  
panel, then connect the plug to a suitable AC outlet.  
DC Units: Remove the protective cover from the DC terminal block, switch off the DC  
power source, and attach the wires from the -48 VDC power source to the screw terminals.  
Connect your ground line to the grounding screw, then replace the protective cover and  
switch the DC power source back on.  
CAUTIONS :  
This device should only be operated with the type of power source indicated  
on the instrument nameplate. If you are not sure of the type of power service  
available, please contact your local power company.  
Reliable earthing (grounding) of this unit must be maintained. Particular  
attention should be given to supply connections when connecting to power  
strips, rather than direct connections to the branch circuit.  
After connecting the unit to the power source, press the Power Switch to the On position. The  
ON indicator should light, and after a brief pause, the RDY indicator should begin to flash.  
3 .2 . Co n n e c t in g a P C t o t h e Co n s o le P o r t  
For this overview, a PC will be connected to the SRM Console Port. This will allow you to  
access the Command Mode and display the menus which are used to select configuration  
parameters, check connection activity, and define and display user passwords.  
No te : Although this overview demonstrates the procedure for communicating with  
the unit via the Console Port, the Command Mode can also be accessed via modem  
as described in Section 5.1.2.  
To connect your PC to the SRM Console Port, proceed as follows:  
1. Attach a standard null modem cable to a COM Port on your PC. Make certain to connect  
to the COM port that is used by your communications program (e.g. ProComm).  
2. Connect the other end of the cable to the Console Port, located on the SRM back panel.  
For a description of the Console Port interface, please refer to Appendix A.  
3 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Getting Started  
3 .3 . Co m m u n ic a t in g w it h t h e SRM-1 0 0  
In order to communicate with the SRM unit for the first time, you must set your  
communications program (e.g. ProComm) to match the default Console Port parameters. Note  
that after you have accessed command mode, you can then use the General Parameters Menu to  
select other Console Port parameters as described in Section 5, and then reset your  
communications program accordingly.  
Start your communications program (e.g. ProComm), and set it to match the following default  
Console Port parameters:  
9600 bps  
8 Data Bits, 1 Stop Bit  
No Parity  
No te : This overview assumes that first time set-up of the SRM unit will be  
performed via a local terminal connected to the SRM Console Port. If necessary,  
first time set-up can also be performed via modem; in this case, access the SRM  
Command Mode as described in Section 5.1.2.  
After setting the communications program to match the default Console Port parameters,  
proceed as follows:  
1. Press [Enter] to activate the SRM Command Mode.  
a) If the Console Port Password has previously been defined, the SRM will display a  
password prompt. Key in the Console Port Password, or System Password  
(Default = SUPER) and press [Enter].  
b) If the Console Port Password has not been defined, you will be granted immediate  
access to the SRM command mode.  
2. After a brief pause, the unit should display the Help Screen shown in Figure 3.1, followed  
by the "SRM>" command prompt.  
3. If the Command Prompt and Help Screen are not displayed, check to make certain that the  
correct communications parameters have been selected, cable connectors are firmly  
seated, and that the cable has been connected to the COM Port that is used by your  
communications program.  
When the "SRM>" command prompt is displayed, you can invoke the commands listed in the  
Help Menu to display the various configuration menus and status screens.  
3 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Getting Started  
Secure Rack Modem  
Version: 1.13  
Site: (undefined)  
COMMANDS  
/H Display Help Screen  
/G View/Set General Parameters  
/M View/Set Modem Parameters  
/E Edit Password Directory  
/D View Password Directory  
/C View Audit Log  
/U Utilities  
/X Exit/Disconnect  
Modem Type:  
Reset String:  
Init String:  
MT2834ZPX  
ATZ  
AT&C1&D2E0Q1V1M1S0=1&E1&E15S13=0  
Hang-Up String: (undefined)  
MODEM PORT SETTINGS  
Baud Rate:  
Flow Control:  
Local Echo:  
9600  
RTS/CTS  
Off  
Result Codes: Verbose  
Speaker: On  
Error Control: On  
Rings to Answer: 1  
Compression:  
Ignore DTR:  
On  
Off  
Quiet Mode:  
On  
Figure 3.1: The SRM-100 Help Screen  
For the purpose of this overview, it is only recommended to review the information on each  
menu in order to familiarize yourself with the unit; it is not necessary to actually enter  
parameters at the configuration menus at this time.  
1. View/Set General Parameters: From the command prompt, type /Gand press [Enter].  
The General Parameters Menu will be displayed. This menu is used to set Console Port  
communication parameters, define the System Password, Console Port Password, and  
select other general parameters as described in Section 5.2. Press [Esc] to return to the  
Main Menu.  
2. View/Set Modem Parameters: Type /M and press [Enter] to display the Modem  
Parameters menu. This menu is used to select communication parameters for the SRM's  
internal modem as described in Section 5.3. Press [Esc] to return to the  
Main Menu.  
3. Utilities Menu: Type /Uand press [Enter] to display the Utilities Menu. This menu is  
used to access SRM-100 command features, such as the Pass-Through Mode (see  
Section 7.6.8), the Download Parameters Function (see Section 8.1), and others. Press  
[Esc] to return to the Main Menu. For more information on the Utilities Menu, please  
refer to Section 7.6.  
4. Other Menus: At this point, commands such as "View Password Directory" and "View  
Audit Log" will not display much information. This is due to the fact that the Password  
Directory has not been defined yet, and the Audit Log has not had the opportunity to  
record connection activity. If you wish to display these menus, key in the appropriate  
command and then press [Enter]. To exit a menu, press [Esc] to return to the  
Main Menu.  
3 -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Getting Started  
5. Exit/Disconnect: When you have finished exploring the various SRM command menus,  
return to the "SRM>" Command Prompt, and then type /Xand press [Enter] to exit from  
command mode.  
This completes the introductory overview of the SRM-100. In order to demonstrate the SRM's  
security functions, you must completely install the unit, and define the Password Directory as  
explained later in this User's Guide. Please proceed to Sections 4 through 6 for complete  
installation and configuration instructions.  
3 -4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 . Ha r d w a r e In s t a lla t io n  
4 .1 . Ra c k Mo u n t in g In s t a lla t io n  
When installing the SRM-100 is an instrument rack, the following factors must be accounted  
for:  
1. Enclosed Racks: Enclosed racks must provide adequate ventilation. Make certain that  
the rack is not overly crowded, and note that each unit in the rack generates its own heat.  
An enclosed rack should have louvered sides and a fan to circulate cooling air. The  
maximum temperature for the equipment in this environment is 45°C.  
When mounting the unit in an enclosed rack with a ventilation fan at the top of the rack,  
note that excessive heat generated by devices at the bottom of the rack can be drawn  
upward and into the ventilation slots on units located at the top. Make certain to provide  
adequate ventilation for equipment installed at the bottom of the rack.  
2. Open Racks: Make certain that the rack frame does not block the ventilation slots on the  
instrument cover. If the device is installed on sliders, check the unit when seated all the  
way into the rack to make certain that ventilation slots are not blocked.  
4 .2 . Co n n e c t in g P o w e r t o t h e SRM-1 0 0  
The SRM-100 is available in both AC and DC powered versions.  
CAUTIONS :  
This device should only be operated with the type of power source indicated  
on the instrument nameplate. If you are not sure of the type of power service  
available, please contact your local power company.  
Reliable earthing (grounding) of this unit must be maintained. Particular  
attention should be given to supply connections when connecting to power  
strips, rather than direct connections to the branch circuit.  
4 . 2 . 1 . AC P o w e r e d Un it s  
Set the Voltage Selector Switch (located on the SRM back panel) to the appropriate voltage.  
Plug the supplied power cable into the receptacle on the SRM-100 back panel, and then connect  
the power cable to an appropriate, grounded (earthed) AC outlet.  
4 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Hardware Installation  
Figure 4.1: Terminal Block Assembly and Grounding Screw (DC Units Only)  
4 . 2 . 2 . DC P o w e r e d Un it s  
When connecting the SRM to a -48 VDC power source, first remove the protective cover from  
the DC terminal block. Switch off the DC power source, then attach the wires from the power  
source to the screw terminals, and connect your ground line to the labeled ground screw. Next,  
replace the protective cover, and switch the DC power source back on. Note that the DC  
terminal block features a dual bus configuration to allow connection to a back-up power  
supply.  
4 .3 . Se t Up Sw it c h e s  
The SetUp Switches select default settings for Modem Port baud rate, flow control, parity,  
rings to answer, ARQ/Compression, the modem speaker, and the SRM-100 Security Mode.  
No te : Operating values for these parameters can also be selected via the SRM’s  
configuration menus. However, if the unit is reset to default parameters, these  
settings will return to the default values selected by the SetUp switches.  
4 . 3 . 1 . De f a u lt Mo d e m Ba u d Ra t e (Sw 1 , Sw 2 )  
SetUp Switches one and two select the default baud rate for the SRM’s internal modem and the  
serial Modem Port. The Modem Baud Rate can also be selected via the Modem Parameters  
Menu (/M). If the unit is reinitialized, the baud rate will return to the setting specified by  
SetUp Switches one and two.  
No te : Automatic baud rate sensing is disabled. This allows the SRM to function  
with devices that do not automatically negotiate the baud rate.  
Default Modem Baud Rate  
9600 bps *  
S w1  
Down  
Down  
Up  
S w2  
Down  
Up  
38.4K bps  
19.2K bps  
Down  
Up  
2400 bps  
Up  
* = Factory Setting  
4 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Hardware Installation  
4 . 3 . 2 . De f a u lt Flo w Co n t r o l Fo r m a t (Sw 3 )  
SetUp Switch three selects the default flow control (handshaking) format for the serial Modem  
Port. The Modem Port flow control format can also be selected via the Modem Parameters  
Menu. If the unit is reinitialized, the flow control format will return to the setting specified by  
SetUp Switch three.  
De fa u lt Flo w Co n tro l Fo rm a t  
None *  
S w3  
Down  
Up  
RTS/CTS (Hardware)  
* = Factory Setting  
4 . 3 . 3 . De f a u lt Bit s a n d P a r it y (Sw 4 )  
SetUp Switch four selects the default bits and parity setting for both the internal modem and  
the serial Modem Port. The bits and parity can also be selected via the Modem Parameters  
Menu (/M). If the unit is reinitialized, bits and parity will return to the setting specified by  
SetUp Switch four.  
De fa ult Bits a nd Pa rity  
S w4  
Down  
Up  
8 Bits, No Parity, 1 Stop Bit *  
7 Bits, Even Parity, 1 Stop Bit  
* = Factory Setting  
4 . 3 . 4 . De f a u lt Rin g s t o An s w e r (Sw 5 )  
SetUp Switch five selects the default “Rings to Answer” setting. The Rings to Answer setting  
can also be defined via the Modem Parameters menu (/M). If the SRM-100 is reinitialized, the  
Rings to Answer feature will return to the setting selected by SetUp Switch five.  
De fa ult Rings to Ans we r  
S w5  
Down  
Up  
One *  
Eight  
* = Factory Setting  
4 -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Hardware Installation  
4 . 3 . 5 . De f a u lt ARQ/ Co m p r e s s io n St a t u s (Sw 6 )  
SetUp Switch six selects the default enabled/disabled status for the ARQ/Compression feature.  
The ARQ mode and compression feature can also be enabled or disabled via the Modem  
Parameters menu (/M). If the SRM-100 is reset to default parameters, these features will return  
to the default settings selected by SetUp Switch six.  
Default ARQ / Compres s ion Status  
S w6  
Down  
Up  
Enable *  
Disa ble  
* = Factory Setting  
4 . 3 . 6 . De f a u lt Mo d e m Sp e a k e r St a t u s (Sw 7 )  
SetUp Switch seven selects the default enabled/disabled status for the modem speaker. The  
Modem Parameters menu (/M) can also be used to enable/disable the speaker. If the SRM is  
reinitialized, this feature will return to the setting selected by SetUp Switch seven.  
De fa ult Mode m S pe a ke r S ta tus  
S w7  
Down  
Up  
On *  
Off  
* = Factory Setting  
4 . 3 . 7 . De f a u lt Se c u r it y Mo d e St a t u s (Sw 8 )  
SetUp Switch eight selects the default enabled/disabled status for the Security Mode. The  
Security Mode can also be disabled via the General Parameters Menu (/G). If the unit is  
reinitialized, the Security Mode will return to the default status selected by SetUp Switch  
eight.  
No te : If Modem Security is disabled (off), all password and security features will  
be suppressed, and you will not be able to access the SRM command mode via  
modem (although Console Port access to command mode is still allowed). When  
the Security Mode is disabled, the SRM will function like a normal non-secure,  
modem  
Security Mode  
S w8  
Down  
Up  
On *  
Off  
* = Factory Setting  
4 -4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Hardware Installation  
4 .4 . In it ia liz e Un it t o De f a u lt Se t t in g s  
If SetUp Switch settings are changed, new parameters will not take effect until the SRM-100 is  
initialized.  
CAUTION: After initialization, menu selected parameters will return to the  
settings specified by the SetUp Switches and the Password Directory will also  
be erased.  
No te : To reset the SRM to default parameters without clearing the Password  
Directory, use the "Default Parameters" option in the Utilities menu as described in  
Section 7.6.4.  
1. Set the SRM-100 Power Switch to the OFF position.  
2. Press and hold the Default Button (located on the back panel). Place the SRM-100 Power  
Switch in the ON position.  
3. Wait for one second (or until the front panel LEDs flash three times), and then release the  
Default Button.  
4 .5 . Ca b le Co n n e c t io n  
Connect cables and telco line as described in the sections that follow. Please refer to  
Appendix A for a description of Port interfaces.  
4 . 5 . 1 . Mo d e m P o r t  
The serial Modem Port is used for connection to your secure device. Use a straight wired  
modem cable to connect the secure device to the SRM-100 serial Modem Port. For a  
description of the Modem Port interface, please refer to Appendix A.  
4 . 5 . 2 . Co n s o le P o r t  
The SRM Command Mode allows the system administrator to define passwords, select  
configuration parameters, and review the connection activity log. There are two different ways  
to access the Command Mode: via a dial-up connection, or via a local PC connected to the  
SRM's Console Port.  
If your SRM will be controlled and configured via the Console Port, use an appropriate cable  
to connect the Console Port to the COM port on your PC or terminal. Appendix A describes  
the Console Port interface. Note that if your installation will be controlled and configured via  
modem, it is not necessary to connect a PC to the Console Port.  
No te : If the SRM will be installed in an area that is accessible by unauthorized  
personnel, it is recommended to define the Console Port Password as described in  
Section 5.2. This will protect access to the SRM Command Mode via the Console  
Port.  
4 -5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Hardware Installation  
4 . 5 . 3 . Te lc o Lin e  
Use a standard RJ11 phone cable to connect your phone line outlet to the Telco Line port on the  
SRM back panel. If the SRM's Telco Line port includes two RJ11 connectors, connect your  
phone line to the connector labeled "Wall" or "Line".  
4 -6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 . Se t -Up a n d Co n f ig u r a t io n  
This section describes the procedure for configuring the SRM unit to fit the needs of your  
installation. Note that the default SRM parameters are intended to fit the requirements of most  
applications. Before configuring the unit, please review the default settings to determine if any  
parameters must be changed. In many cases, the factory defaults will work just fine.  
5 .1 . Co m m a n d Mo d e Ac c e s s  
There are two ways to access the SRM Command Mode; via the Console Port and via Modem.  
Note that while the Command Mode is active, inbound callers will receive a busy signal.  
5 . 1 . 1 . Ac c e s s Via t h e Co n s o le P o r t  
When a Local PC or terminal is connected to the SRM Console Port, system administrators can  
access the Command Mode as follows:  
1. Start your communications program (e.g. ProComm) and then press [Enter].  
2. If the Console Port Password has been defined, a password prompt will be displayed.  
Key in either the Console Port Password, or the System Password (Default = SUPER),  
and then press [Enter]. Note that if the Console Port Password has not been defined, the  
Password prompt will not be displayed. The SRM Help Screen (see Figure 5.1) will be  
displayed.  
If the SRM-100 does not respond, check the following:  
Console Port Communication Parameters: The SRM Console Port and your  
communications program or terminal must be set to use the same communication  
parameters. The factory set default Console Port parameters are 9600 bps, No Parity, 8  
Data Bits,  
One Stop Bit.  
Correct Port: Make certain that your communications program or terminal is set to use  
the Com port that is connected to the SRM Console Port.  
5 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
Secure Rack Modem  
Version: 1.13  
Site: (undefined)  
COMMANDS  
/H Display Help Screen  
/G View/Set General Parameters  
/M View/Set Modem Parameters  
/E Edit Password Directory  
/D View Password Directory  
/C View Audit Log  
/U Utilities  
/X Exit/Disconnect  
Modem Type:  
Reset String:  
Init String:  
MT2834ZPX  
ATZ  
AT&C1&D2E0Q1V1M1S0=1&E1&E15S13=0  
Hang-Up String: (undefined)  
MODEM PORT SETTINGS  
Baud Rate:  
Flow Control:  
Local Echo:  
9600  
RTS/CTS  
Off  
Result Codes: Verbose  
Speaker: On  
Error Control: On  
Rings to Answer: 1  
Compression:  
Ignore DTR:  
On  
Off  
Quiet Mode:  
On  
Figure 5.1: The SRM-100 Help Screen  
5 . 1 . 2 . Ac c e s s v ia Mo d e m  
To access the SRM Command Mode via modem, dial the number for the phone line connected  
to the SRM unit. When the Password Prompt is displayed, key in your System Password  
(Default = SUPER) and press [Enter]. The SRM will display the Help Screen as shown in  
Figure 5.1. Note that the password is case sensitive.  
If the System Dial Back number has been defined (see Sections 5.2 and 7.2.4), the SRM will  
dial the defined number before allowing access to the Command Mode. In this case, when the  
valid System Password is entered, the SRM will disconnect, and call the System Dial Back  
number before allowing access to Command Mode.  
If the “Password on Dial Back” feature (see Sections 5.2 and 7.2.5) is enabled, the SRM will  
redisplay the password prompt to the answering party. If the System Password is entered by  
the answering party, the SRM will allow access the Command Mode.  
If the SRM does not respond, check the following:  
Modem Communication Parameters: The SRM's internal modem and your remote  
communications program must be set to use the same communication parameters. Default  
modem communication parameters are selected using SetUp Switches one through eight  
(Factory Setting = 9600 bps, No Parity, 8 Data Bits, One Stop Bit).  
5 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
GENERAL PARAMETERS:  
1. System Password:  
2. Console Port Password:  
3. System Dial Back #:  
4. Site ID:  
SUPER  
(undefined)  
(undefined)  
(undefined)  
5. Real-Time-Clock  
Thu 03/08/2001 14:14:04  
6. Console Port Communication:  
7. Command Echo:  
9600,N,8,1  
On  
8. No Activity Timeout:  
9. Password Attempts:  
10. Password on Dial Back:  
11. Security Mode:  
5 Min.  
3
Off  
On  
12. Audit Log Options:  
13. Dial Back Attempts:  
14. Dial Back Delay  
All  
1
30 Sec.  
Enter Selection,  
Press <ESC> to abort ...  
Figure 5.2: The General Parameters Menu  
5 .2 . Th e Ge n e r a l P a r a m e t e r s Me n u  
To access the General Parameters menu (Figure 5.2), activate the command mode, then type /G  
[Enter]. To change parameters, key in the number for the desired item, press [Enter], then  
follow the instructions in the submenu.  
1. System Password: This password protects access to the Command Mode. When a  
caller connects to the SRM, a password prompt is sent. If the System Password is  
entered at this prompt, the caller will be granted access to the Command Mode.  
Note that the System Password is case sensitive.  
(Up to 16 characters, Default = SUPER).  
No te s :  
• If the System Password is deleted or cleared, remote access (via modem) to the  
SRM Command Mode will be disabled.  
• The same password can be defined for both the System Password and the Console  
Password.  
• The System Password cannot be the same as a defined User Password. If you  
attempt to define a System Password that is the same as an existing User  
Password, an error message will be sent.  
5 -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
2. Console Port Password: When the Console Port Password is defined, the SRM will  
display a prompt before allowing access to the SRM Command Mode via the Console  
Port. (Up to 16 characters, Default = undefined).  
No te s :  
• If the Console Port Password is not defined, users are allowed to access the SRM  
command mode via the Console Port without a password.  
• The same Password can be defined for both the Console Port Password and the  
System Password.  
• The Console Port Password cannot be the same as a defined User Password. An  
error message will be sent if you attempt to define a Console Port Password that is  
the same as an existing User Password.  
3. System Dial Back #: When defined, the SRM will dial this number before allowing  
command mode access via modem. If an inbound caller enters the valid System  
Password, the SRM will disconnect and then call the System Dial Back number. When  
the Dial Back number answers, the Command Mode will start. (Up to 32 characters,  
Default = undefined).  
No te : While a Dialback operation is in progress, the SRM will not accept  
incoming calls or recognize commands entered via the Console Port.  
4. Site ID: Defines a text string which is used to identify the SRM unit's installation site.  
(Up to 32 characters, Default = undefined).  
5. Real Time Clock: Sets the SRM's internal real time clock and calendar. The SRM uses  
the Real Time Clock to determine times and dates when logging connection activity.  
Enter the correct time using 24 hour (military) format.  
6. Console Port Communication: Defines the Baud Rate, Parity Bits, Data Bits, and Stop  
Bits for the Console Port. (Default = 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit).  
No te : If Console Port parameters are changed, new settings will take effect  
immediately, and may effect your ability to communicate with the SRM. Make  
certain to note newly selected parameters, and set your communications program to  
match.  
7. Command Echo: Enables/disables the command echo. When enabled, characters sent to  
the SRM will be echoed back and shown on the display monitor. (Default = On).  
8. No Activity Timeout: Selects the timeout value for all ports. If no data or command  
activity is detected during this period, the SRM will disconnect or exit from command  
mode. (Default = 5 Min.).  
5 -4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
9. Password Attempts: The number of password attempts that will be accepted when a  
user attempts to access the SRM via modem. If this number is exceeded, the SRM will  
terminate the modem connection. (Default = 3).  
No te : If the number of password attempts is set to zero, the User Password  
requirement is disabled. In this case, if the unit is contacted via modem, the  
password prompt will still be displayed, but callers will be allowed to access the  
secure device by pressing [Enter] in response to the prompt. Note however, that  
the SRM will continue to log access attempts, and the System Password will  
continue to protect access to the Command Mode.  
10. Password on Dial Back: This item adds an additional layer of security to the Dial Back  
feature; when a Dial Back is performed, the SRM will prompt the answering party to  
enter a password before allowing access. When this feature is enabled, it will be applied  
to both User Password Dial Backs and System Password Dial Backs. Note that the  
answering party must enter the same password that was entered to initiate the Dial Back.  
(Default = Off).  
11. Security Mode: This item can be used to disable the SRM-100’s security features.  
When the Security Mode is Off, the SRM will function like a normal, unsecured modem.  
Callers will be granted access to the secure device without entering a password. (Default  
Determined by SetUp Switch 8, Factory Setting = On).  
No te s :  
• When the Security Mode is disabled, the SRM will not prompt callers to enter a  
Password before allowing access to the secure device.  
• If the Security Mode is disabled (off), you will not be able to access the SRM  
command mode via modem, and the command mode will only be accessible via  
the Console Port using the System Password or Console Port Password.  
12. Audit Log Options: This item determines which type of calls will be recorded in the  
SRM’s Audit Log. The SRM can log all connection attempts, only successful attempts, or  
only unsuccessful attempts. This log will list the user name, password entered, duration  
of the call, and exit status. Section 7.5 describes the Audit Log screen.  
(Default = All).  
13. Dial Back Attempts: This item determines how many times the SRM will attempt to  
contact the Dial Back Number if the initial call is not successful. (Default = 1).  
14. Dial Back Delay: Determines how much time will elapse between each Dial Back  
Attempt. (Default = 30 Seconds).  
When you have finished selecting parameters from the General Parameters menu, press [Esc] to  
return to the main Help Screen. Menu selected parameters will be stored in the SRM’s non-  
volatile memory.  
5 -5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
MODEM PARAMETERS  
1. Baud Rate:  
9600  
2. Bits/Parity:  
3. Stop Bits:  
8-None  
1
4. Flow Control:  
5. Local Echo:  
6. Rings to Answer:  
7. Quiet Mode:  
None  
Off  
1
On  
8. Result Codes:  
9. Speaker:  
Verbose  
On  
10. Error Control:  
11. Compression:  
12. Reset String:  
13. Custom Init String:  
14. Hang-Up String:  
15. Ignore DTR:  
On  
On  
ATZ  
(undefined)  
(undefined)  
On  
Enter Selection,  
Press <Esc> to abort ...  
Figure 5.3: The Modem Parameters Menu  
5 .3 . Th e Mo d e m P a r a m e t e r s Me n u  
The Modem Parameters Menu selects communication parameters for both the SRM’s internal  
modem and the SRM's serial Modem Port. To display the Modem Parameters Menu, access the  
Command Mode as described in Section 5.1, then type /Mand press [Enter].  
To change the setting for any item in this menu, key in the number for the desired item, press  
[Enter] and then follow the instructions in the submenu. The Modem Parameters Menu  
includes the following items:  
1. Baud Rate: The operating baud rate for the SRM's modem and serial Modem Port. If  
the unit is reinitialized, the baud rate will return to the default value selected by SetUp  
Switches One and Two. (Default Determined by SetUp Switches 1 & 2;  
Factory Setting = 9600).  
No te : Automatic baud rate sensing is disabled. This allows the SRM to function  
with devices that do not automatically negotiate the baud rate.  
2. Bits / Parity: The operating Data Bits and Parity Bits for the SRM's modem and serial  
Modem Port. If the unit is initialized to default settings, the Bits and Parity will return to  
the default setting currently selected by SetUp Switch 4. (Default is Determined by  
SetUp Switch 4; Factory Setting = 8-None).  
3. Stop Bits: The setting for the SRM-100's modem. (Default = 1).  
4. Flow Control: This item selects the operating flow control format for the SRM’s internal  
modem. Note that if the SRM is initialized to defaults, the modem will return to the  
default flow control format selected by SetUp Switch 3. (Default Determined by SetUp  
Switch 3; Factory Setting = None).  
5 -6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
5. Local Echo: Enables / disables the local echo for the SRM’s internal modem.  
(Default = Off).  
6. Rings to Answer: Determines how many rings will elapse before the SRM’s internal  
modem answers an incoming call. Note that if the SRM is reinitialized, the modem will  
return to the setting selected by SetUp Switch 5. (Default Determined by SetUp Switch  
5; Factory Setting = 1).  
7. Quiet Mode: Enables / disables the Quiet Mode. When enabled, the SRM’s internal  
modem will not send result codes in response to AT commands. (Default = On).  
8. Result Codes: Determines whether the SRM will respond to AT commands with Terse  
(numeric / abbreviated) or Verbose (English text) messages. For a listing of possible AT  
Result Codes, please refer to the on-line SRM User's Guide in the User's Guide Archive  
enabled, the SRM will not send responses to AT commands, regardless of which Result  
Code setting is selected. (Default = Verbose).  
9. Speaker: Enables/disables the modem speaker. (Default Determined by SetUp Switch 7;  
Factory Setting = On).  
10. Error Control: Enables / Disables the error control function. (Default Determined by  
SetUp Switch 6; Factory Setting = On).  
11. Compression: Enables / Disables the data compression function. (Default = On).  
12. Reset String: If necessary, this item can be used to redefine the Modem Reset String.  
(Up to 16 characters, Default = ATZ).  
13. Custom Initialization String: This item is used to “customize” the SRM’s modem  
initialization string. During configuration, the unit will build an initialization string  
based on items selected from the Modem Parameters Menu. This string will consist of  
four components; (1) The default string header (AT&C1&D2), (2) the responses to items 1  
through 11 in the Modem Parameters Menu, (3) an S-Register command, and (4) any  
special AT commands entered via item 13. For a listing of available AT commands,  
please visit the User's Guide Archive at the WTI web site  
14. Hang-Up String: This item is used to define tasks that are performed after the SRM  
hangs up at the end of a communication session. Typically, the Hang-Up string would be  
used to clear memory, or reset the modem to a set of user-defined parameters. To define  
the Hang-Up String, simply key in the appropriate AT commands for the desired  
operation(s). For a listing of available AT commands, please visit the User's Guide  
Archive at the WTI web site (http://www.wti.com/guides/guidarch.htm). (Up to 16  
characters, Default = undefined).  
5 -7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Set-Up and Configuration  
15. Ignore DTR: When this item is enabled, the SRM-100 will ignore the DTR hardware  
input line at the serial Modem Port. This allows the serial modem port to be connected to  
a device that does have a DTR line. (Default = On)  
When you have finished selecting modem configuration parameters, press [Esc] to return to the  
main Help Screen. User-selected parameters will be saved in the SRM’s non-volatile memory.  
No te : In order for the SRM's security related features to function properly, you  
must define at least one User Password as described in Section 6.  
5 .4 . Sa v e P a r a m e t e r s  
After the unit has been completely configured, it is recommended to save configuration  
parameters to an ASCII file as described in Section 8. This allows quick recovery in the event  
that the unit is reset to default parameters, or configuration is accidentally deleted or altered.  
5 -8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 . Th e P a s s w o r d Dir e c t o r y  
When the SRM-100 is properly configured, each inbound caller will be prompted to enter a  
password before being allowed to access the secure device. The Password Directory is  
basically a listing of all valid user passwords, user names, and their associated Dial Back  
numbers.  
The SRM-100 will accept up to 100 User Passwords, one System Password, and one Console  
Port Password. User passwords allow access to the secure device connected to the SRM-100  
serial Modem Port, the System Password allows access to the SRM Command Mode via  
Modem or Console Port, and the Console Port Password allows access to the Command Mode  
via the Console Port only. As discussed in Section 5.2, the System Password and Console Port  
Password are defined via the General Parameters Menu. The procedure for defining User  
Passwords is described in this chapter.  
To add passwords to the directory or edit existing User Passwords, make certain the command  
mode is active, then type /Eand press [Enter]. The SRM-100 will display the Edit Password  
Directory Menu shown in Figure 6.1. This menu offers three options; Add Name/Password,  
Edit/Delete from List, and Edit/Delete from Search.  
After defining the Password Directory, you may wish to review its contents. Section 6.4  
describes the procedure for displaying the Password Directory and explains the directory  
screen.  
No te s :  
• User Passwords do not allow access to the SRM Command Mode.  
• In order protect access to the secure device, the Security Mode must be enabled  
(see Section 5.2) and at least one User Password must be defined.  
EDIT PASSWORD DIRECTORY  
1. Add Name/Password  
2. Edit/Delete from List  
3. Edit/Delete from Search  
Enter Selection,  
Press <Esc> to abort ...  
Figure 6.1: The Edit Password Directory Menu  
6 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
The Password Directory  
6 .1 . Ad d Na m e / P a s s w o r d  
To add new User Passwords to the directory, go to the Edit Password Directory Menu (/E), type  
1 (Add Name / Password) and press [Enter]. The SRM will display a submenu that contains  
the following items:  
1. Name: Assigns a Name to each User Password. Note that the SRM will not prompt  
callers to enter the User Name in order to log in. This name is used only to associate  
each password with a specific client or employee. (Up to 16 characters).  
No te s :  
• The SRM will not accept duplicate user names.  
• The unit will display an error message if you attempt to define a user name that is  
already in use.  
2. Password: Assigns a Password for each user. When a caller attempts to log on, a valid  
User Password must be entered in order to access the secure device.  
(Case sensitive, Up to 16 characters.).  
No te s :  
• The SRM will not accept duplicate User Passwords.  
• User Passwords cannot be the same as the existing System Password or Console  
Port Password.  
• An error message will be sent if you attempt to define a User Password that is the  
same as an existing User Password, System Password, or Console Port Password.  
3. Dial Back Number: Assigns a Dial Back Number to each User Password. If the Dial  
Back Number is not defined, a caller who accesses the SRM with this User Password will  
be granted immediate access to the secure device. If the Dial Back Number is defined,  
when a caller enters this User Password, the SRM will disconnect, call the Dial Back  
Number, and then allow the answering party to access the secure device. (Up to 32  
chars.)  
No te s :  
• The SRM can be configured to perform a Dial Back for some User Passwords,  
while providing immediate access to other User Passwords.  
• While a Dial Back operation is in progress, the SRM is not able to accept  
incoming calls, and will not recognize commands entered via the Console Port.  
• If the initial call is not successful, the SRM will repeat the Dial Back procedure as  
specified by item 12 (Dial Back Attempts) and item 13 (Dial Back Delay) in the  
General Parameters Menu (see Section 5.2).  
4. Save Entry: This item stores the Password, Name, and Dial Back Number in the  
Password Directory. If you are satisfied with the data entered at prompts 1 through 3,  
type 4and press [Enter] to save this information in non-volatile memory.  
After each password is saved, the SRM-100 will redisplay the Add Name/Password menu. To  
continue to add names and passwords, repeat steps one through four above. If you have  
finished adding passwords, press [Esc] to return to the Edit Password Directory Menu.  
6 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
The Password Directory  
EDIT/DELETE NAME/PASSWORD:  
1. Name:  
A. User  
2. Password:  
3. Dial Back #:  
4. Save Entry  
5. Delete Entry  
secret  
15555551212  
Type "<" <Enter> previous entry, ">" <Enter> next entry,  
<number><Enter> to select item,  
<ESC> to abort ...  
Figure 6.2: The Edit/Delete Name/Password Menu  
6 .2 . Ed it / De le t e f r o m Lis t  
Options 2 and 3 in the Edit Password Directory Menu are used to edit and/or delete passwords  
from the Password Directory. The difference between these two options is the manner in which  
the desired password is selected. When Option 2 is used, the desired password is selected from  
a list of all passwords. When Option 3 is used, the password is selected by searching for a  
specific password or user name.  
To use Option 2 to edit or delete User Passwords, proceed as follows:  
1. Go to the Edit Password Directory Menu (/E). Type 2(Edit / Delete from List) and press  
[Enter].  
2. The SRM will display the first line of the Password Directory.  
a) To select a password, press >or <until the desired password appears at the bottom of  
the list. The password at the bottom of the displayed list is the currently selected  
password.  
b) To display the next 15 lines of the directory, press [Enter].  
3. When the desired password appears at the bottom of the list, press E. The Menu shown in  
Figure 6.2 will be displayed. Note that the password that appears at the bottom of the  
displayed list is the selected password.  
4. Edit Password: To edit the selected password, type the number for the field that you  
wish to change and follow the instructions in the submenu.  
a) For example, to change the Dial Back Number for the selected password, type 3,  
press [Enter], and then key in the new number as described in the submenu.  
b) When you have finished editing the password, return to the Edit/Delete  
Name/Password Menu; type 4and press [Enter] to save the edited password to the  
Password Directory.  
c) To edit another password type >and press [Enter] for the next password, or type <  
and press [Enter] for the previous password.  
d) To exit from the Edit/Delete Name/Password Menu, press [Esc], the SRM will display  
the new listing for the edited password. To return to the main help screen, press  
[Esc], or type /Hand press [Enter] .  
6 -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
The Password Directory  
5. Delete Password: To delete the selected password, type 5and press [Enter] .  
a) The SRM-100 will ask for confirmation, and then delete the selected password from  
the directory. Note that passwords cannot be “undeleted”. After you confirm that the  
selected password should be deleted, the SRM will display the next password in the  
list.  
b) To continue to delete or edit passwords, use the > and < keys to scroll through the list  
until the desired password is selected (appears at bottom of list). Then press Eto edit  
or delete the next password.  
c) To exit from the Edit / Delete Name / Password Menu, press [Esc], or type /Hand  
press [Enter] to return to the main Help Screen.  
6 .3 . Ed it / De le t e f r o m Se a r c h  
When Option 3 is used to edit or delete passwords, the password is selected by searching for  
the specific password or user name. To search for the specific password to be edited or  
deleted, proceed as follows:  
1. From the Edit Password Directory Menu (/E). Type 3(Edit / Delete from Search) and  
press [Enter] .  
2. The SRM-100 will display a menu which offers the option to search by name or search by  
password.  
a) To search by name, type 1 and press [Enter]. To search by user password, type 2 and  
press [Enter].  
b) If the desired name or password is found, the SRM-100 will display the Edit/Delete  
Name/Password Menu as shown in Figure 6.2.  
3. Edit Password: To edit the selected name / password, type the number for the field that  
you wish to change and follow the instructions in the submenu.  
a) For example, to change the Dial Back Number for the selected password, type 3,  
press [Enter], and then key in the new number as described in the submenu.  
b) When you have finished editing the password, return to the Edit / Delete Name /  
Password Menu; type 4and press [Enter] to save the edited password.  
c) To edit another password type >and press [Enter] for the next password, or type <  
and press [Enter] for the previous password.  
d) To exit from the Edit / Delete Name / Password Menu, press [Esc], the SRM will  
display the listing for the edited password. To return to the main help screen, press  
[Esc], or type /Hand press [Enter] .  
6 -4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
The Password Directory  
4. Delete Password: To delete the selected password, type 5and press [Enter] .  
a) The SRM-100 will ask for confirmation, and then delete the selected password from  
the directory. Note that passwords cannot be "undeleted". After you confirm that the  
selected password should be deleted, the SRM will display the next password in the  
list.  
b) To continue to delete or edit passwords, use the > and < keys to scroll through the  
list until the desired password is selected (appears at bottom of list). Then press Eto  
edit or delete the next password.  
c) To exit from the Edit / Delete Name / Password Menu, press [Esc], or type /Hand  
press [Enter] to return to the main Help Screen.  
6 .4 . Vie w in g t h e P a s s w o r d Dir e c t o r y  
After you have added several names and passwords, you may wish to view the Password  
Directory in order to verify that data has been correctly entered. To display a screen which  
lists all currently defined User Names and User Passwords, type /Dand press [Enter]. The  
SRM will display the screen shown in Figure 6.3.  
No te : This command will not display the System Password. To display the System  
Password, you must access the General Parameters menu (/G).  
The Password Directory display includes the following items:  
1. Name: The user defined name for this password. Note that callers will not be prompted  
to enter their User Name; only the password. The "Name" is generally used to identify  
the user or client associated with each password.  
No te : In the Password Directory, lines are sorted alphabetically by name.  
Uppercase letters are listed before lower case letters, and letters are listed before  
symbols.  
Name  
Password  
Dial Back #  
Activity  
------------------------------------------------------------------------------  
A. Lincoln  
B. Ross  
B. Ruth  
C. Coolidge  
D. Crocket  
D. Madison  
F. Roosevelt  
G. Washington  
N. Armstrong  
P. Revere  
stovepipehat  
flag  
homerun  
silentcal  
coonskincap  
cake  
dime  
cherrytree  
moon  
19495551234  
(undefined)  
(undefined)  
(undefined)  
15155551111  
(undefined)  
17145554321  
(undefined)  
(undefined)  
(undefined)  
12135559876  
12145553741  
12  
11  
15  
14  
0
5
9
31  
3
23  
15  
8
horse  
nickel  
roughride  
T. Jefferson  
T. Roosevelt  
1234567890123456 1234567890123456 12345678901234567890123456789012  
0
Reached End of Directory.  
Press <Enter> to continue ...  
Figure 6.3: The Password Directory (Sample Data Shown)  
6 -5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
The Password Directory  
2. Password: The User Password that is currently defined for this name. Note that the  
password is case sensitive.  
3. Dial Back Number: The Dial Back Number currently defined for this name. Note that if  
the Dial Back Number has not been defined, this field will read "undefined".  
4. Activity: The number of times this password has been used since the last time the  
activity counter was reset. The procedure for resetting the activity counter is discussed in  
Section 6.5.  
6 .5 . Ze r o Ac t iv it y Co u n t e r s  
In order to track password activity, the Password Directory screen lists the number of access  
attempts for each user password/name. From time to time, you may wish to re-zero these  
counters to obtain a more accurate picture of password activity. To Zero the Activity Counters,  
proceed as follows:  
1. Access the SRM-100 Command Mode as described in Section 5.1.  
2. When the "SRM>" command prompt appears, type /Uand press [Enter]. The Utilities  
Menu will appear as shown in Figure 7.2.  
3. From the Utilities menu, type 1, then press [Enter] and follow the instructions in the  
submenu.  
6 .6 . Sa v e P a r a m e t e r s  
After the Password Directory has been defined, it is recommended to save SRM configuration  
parameters and the Password Directory to an ASCII file as described in Section 8. This allows  
quick recovery in the event that the unit is reset to default parameters, or configuration is  
accidentally deleted or altered.  
6 -6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 . Op e r a t io n  
7 .1 . SRM Op e r a t in g Mo d e s  
The SRM-100 provides three separate operating modes; the User Mode, the Command Mode,  
and the Unsecured Mode.  
7 . 1 . 1 . Us e r Mo d e  
The User Mode is activated when a caller enters a User Password at the login prompt. The  
User Mode only allows the caller to access the secure device which is connected to the serial  
modem port. The User Mode does not allow access to configuration menus or the Password  
Directory.  
7 . 1 . 2 . Co m m a n d Mo d e  
The Command Mode is activated when a caller enters the System Password at the login prompt,  
or when a local user enters the SRM Command Mode via the Console Port. The Command  
Mode allows access to all SRM-100 configuration menus, and is used to define passwords and  
select operating parameters as described in Sections 5 and 6 of this User's Guide.  
7 . 1 . 3 . Un s e c u r e d Mo d e  
When the Unsecured Mode is active, the SRM will function like a normal, unsecured modem.  
Callers will be allowed to access the secure device without entering a password. The  
Unsecured Mode is activated by placing SetUp Switch 8 in the Up position (see Section 4.3.7),  
or by accessing the General Parameters Menu (see Section 5.2) and disabling the Security  
Mode. Note that when the Unsecured mode is active, you will not be able to access the  
Command Mode via modem; you will only be able to access the SRM Command Mode via the  
console port.  
In order to return to password-protected operation, you must either access the Command Mode  
via the Console Port, and then use the General Parameters Menu to enable the Security Mode,  
or enable the Security Mode by placing SetUp Switch 8 in the Down position, and then  
reinitialize the SRM unit as described in Section 4.4.  
7 .2 . P a s s w o r d Fu n c t io n s  
The SRM-100 features three different types of passwords; the System Password, the Console  
Port Password, and the User Passwords. The System Password allows system administrators to  
invoke configuration commands and review connection activity. The Console Port Password  
allows access to the SRM Command Mode via the Console Port. The User Passwords allow  
callers to access the secure device that is connected to the SRM's serial Modem Port .  
7 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
7 . 2 . 1 . Th e Sy s t e m P a s s w o r d  
The System Password restricts user access to the SRM Command Mode via modem and via the  
Console Port. The Command Mode allows system administrators to invoke commands to select  
configuration parameters, edit the password directory, and review connection activity.  
The SRM allows definition of one System Password, which is defined via the General  
Parameters Menu (/G). The default System Password is "SUPER". Note that the System  
Password is case sensitive.  
When the SRM is accessed via the Console Port, a password prompt will be displayed (if the  
Console Port Password has been defined). If the System Password or Console Port Password is  
entered at this prompt, you will be allowed to access the SRM Command Mode. Likewise,  
when the SRM answers an incoming call, the password prompt is also displayed. However, in  
this case, if the System Password is entered, the caller is still granted access to the Command  
Mode; but if a User Password is entered, the caller will be allowed to access the secure device.  
No te s :  
• If the System Password is cleared or deleted at the General Parameters menu,  
remote users will not be able to access the SRM Command Mode via modem.  
• When defining the System Password, it is recommended that you record the  
password for future reference.  
• If you lose your System Password, the only way to access the Command Mode is  
to access the Command Mode via the Console Port (as described in  
Section 5.1.1.), or reinitialize the unit to default parameters as described in  
Section 4.4.  
7 . 2 . 2 . Th e Co n s o le P o r t P a s s w o r d  
The Console Port Password restricts access to the SRM-100 Command Mode via the Console  
Port only. The SRM allows definition of one Console Port Password, which is defined via the  
General Parameters Menu (/G). The default Console Port Password is undefined.  
No te s :  
• If the Console Port Password is not defined, local users will be able to access the  
SRM Command Mode via the Console port without entering a password.  
• The Console Port Password cannot be used to access the SRM Command Mode  
via Modem.  
• The Console Port Password can be identical to the System Password.  
7 . 2 . 3 . Us e r P a s s w o r d s  
User Passwords allow callers to access the secure device connected to the SRM's serial Modem  
Port. User Passwords do not grant access to the Command Mode. The SRM-100 allows  
definition of up to one hundred User Passwords, which are defined via the Edit Password  
Directory Menu (/E) as described in Section 6. Note that User Passwords are case sensitive.  
7 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
7 . 2 . 4 . Dia l Ba c k Nu m b e r s  
Both the System Password and the User Passwords allow definition of a Dial Back Number.  
When a Dial Back Number has been defined for a given password, callers who enter that  
password will not be granted immediate access. Instead, when a valid password is entered, the  
SRM will disconnect, call the defined Dial Back Number for the password, and then grant  
access to the answering party.  
When a Dial Back for a System Password is performed, the SRM-100 will allow access to the  
Command Mode. When a Dial Back for a User Password is performed, the SRM will allow  
access to the secure device. The System Dial Back Number is defined via the General  
Parameters Menu (/G), and the User Dial Back Numbers are defined via the Edit Password  
Directory Menu (/E).  
Note that when User Dial Back Numbers are defined, the SRM can be configured to perform a  
Dial Back for some User Passwords, while granting immediate access to other User Passwords.  
If the Dial Back Number is not defined for a given password, then a Dial Back will not be  
performed when that password is entered at the log in prompt.  
No te s :  
• Additional callers will receive a busy signal while the Dial Back operation is in  
progress.  
• If the initial call is not successful, the SRM will repeat the Dial Back procedure as  
specified by item 12 (Dial Back Attempts) and item 13 (Dial Back Delay) in the  
General Parameters Menu (see Section 5.2).  
7 . 2 . 5 . P a s s w o r d o n Dia l Ba c k  
The Password on Dial Back option provides an additional level of security when Dial Back  
numbers are used; when a Dial Back is performed, the SRM will prompt the answering party to  
enter a password before allowing access. When this feature is enabled at the System  
Parameters Menu, it will be applied to both System Passwords and User Passwords.  
Each time the SRM is accessed via modem, a password prompt is displayed, and the caller will  
then key in a User Password or System Password. If the password is recognized as valid, the  
SRM will check to see if a Dial Back Number has been assigned to that password.  
If a Dial Back Number has been assigned, the SRM will hang-up, and call the Dial Back  
Number. If "Password on Dial Back" has been enabled, the answering party will again be  
prompted to enter a password. If the System Password is entered, the answering party will be  
allowed to access Command Mode. If a User Password is entered, the answering party will be  
allowed to access the secure device.  
Note that the password entered at the Dial Back prompt must be the same password that was  
entered at the dial in prompt.  
7 -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
7 .3 . Su p p r e s s in g t h e Co n f ir m a t io n P r o m p t  
The SRM will display a confirmation prompt before executing commands such as /X  
(exit/disconnect), or performing tasks such as clearing the Audit Log. Normally, this provides  
one last chance to cancel a command before it is executed. In some cases, you may wish to  
execute a command without being prompted for confirmation. To suppress the prompt, include  
the ",Y" argument in the command line.  
Examples:  
Exit/Disconnect: To exit from Command Mode without displaying the confirmation  
prompt, type /X,Yand press [Enter].  
Delete Audit Log: The Utilities menu includes a function (item 2) which allows you to  
clear all logged connection attempts. If you type 2 and press [Enter], the SRM will  
display a prompt before proceeding. If you type 2,Yand press [Enter], the SRM will  
clear the Audit Log without displaying the prompt.  
7 .4 . Dia lin g Ou t f r o m t h e Mo d e m P o r t  
In addition to limiting access by incoming callers, the SRM-100 can also be used to place  
outgoing calls. The device connected to the SRM's serial Modem Port can access the SRM in  
the same manner as one would access an external modem.  
No te : The SRM does not automatically sense the baud rate. When communicating  
with the unit via the Modem port, make certain your baud rate is set to match the  
SRM.  
1. Set Parameters: Use the SRM's Modem Parameters menu to configure the modem as  
desired (See Section 5.3). The device connected to the serial Modem Port must be set to  
communicate at the same baud rate as the SRM's serial Modem Port.  
2. Execute Dial Command: Invoke an AT command to dial the desired number. For  
example, to dial 555-1234 using tone dialing, the following command line would be sent  
to the SRM via the serial Modem Port: ATDT5551234 [Enter].  
3. Disconnecting: To disconnect and end the modem communication session, type +++,  
and then type ATH0. The modem will disconnect and hang-up.  
For additional AT commands, please refer to the on-line SRM-100 User's Guide at  
7 -4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
Date Time Duration Port Name  
Password Entry Exit Status  
------------------------------------------------------------------------------  
08/11 09:53 00:00:00 M(out)  
No Answer  
08/11 09:49 00:00:00 M(in) T. Jefferson  
08/11 09:42 00:01:05 C  
08/11 09:39 00:00:41 M(in) G. Washington  
08/11 09:37 00:01:35 M(out)  
08/11 09:37 00:00:00 M(in) A. Lincoln  
08/11 09:33 00:02:15 C  
08/11 09:27 00:03:45 M(in) P. Revere  
08/11 09:22 00:00:00 M(in)  
08/11 09:17 00:03:05 M(in) F. Roosevelt  
08/11 09:07 00:05:18 M(in) B. Ross  
08/11 09:05 00:01:30 M(out)  
08/11 09:05 00:00:00 M(in) A. Jackson  
08/11 08:52 00:03:27 M(in) G. Washington  
08/11 08:43 00:05:48 C  
nickel  
Dialing Back  
Exit Command  
Connection Lost  
DTR Drop  
Dialing Back  
Exit Command  
No Activity  
Invalid Password  
DTR Drop  
Connection Lost  
Connection Lost  
Dialing Back  
No Activity  
cherrytree  
stovepipehat  
horse  
secret  
dime  
flag  
twenty  
cherrytree  
No Activity  
08/11 08:40 00:00:00 M(in)  
08/11 08:39 00:00:00 M(in)  
08/11 08:36 00:02:31 M(in) C. Coolidge  
guest  
test  
silentcal  
Invalid Password  
Invalid Password  
DTR Drop  
Press: <Enter> Next 20 entries, <ESC> to abort ...  
Figure 7.1: The Audit Log  
7 .5 . Vie w in g t h e Au d it Lo g  
The Audit Log provides a means to track password use and access attempts. Item 11 in the  
General Parameters menu (/G) determines which type of access attempts will be recorded. The  
Audit Log can be configured to record all connection attempts, only successful attempts, or  
only unsuccessful attempts.  
Note that the Audit Log can only be viewed via the SRM command mode. To display the Audit  
Log, access the command mode as described in Section 5.1, then type /Cand press [Enter].  
Events are listed in reverse chronological order, with the most recent attempts appearing at the  
top of the list.  
The Audit Log will list only the most recent 100 connection attempts. After 100 events are  
recorded, the log will wrap-around; and older events will be deleted as each new event is  
added. If you wish to clear the audit log and delete all entries, access the SRM's Command  
Mode, then type /Uand press [Enter], the Utilities Menu will appear. From the Utilities  
Menu, type 2 (Delete Audit Log), press [Enter] and follow the instructions in the submenu.  
Note that deleted log entries cannot be recovered.  
To view access activity for each individual password, type /Dand press [Enter] to display the  
Password Directory as described in Section 6.4.  
7 -5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
As shown in Figure 7.1, the Audit Log screen includes the date, time, call duration, port used,  
user name, password entered, and exit status. Note the following:  
1. Port Used: Lists the port used for each connection attempt:  
M(out): An outbound call placed by the modem. This usually indicates that the SRM  
has performed a dialback in response to a user password entered at login.  
M(in): An inbound call received by the modem.  
C (Console Port): The Command Mode was accessed via the Console Port.  
S (Serial Port): The device connected to the serial modem port has accessed the  
modem using the pass-through function.  
2. Name: The User Name for the password entered at login. If an invalid password is  
entered, this column will be blank.  
3. Password Entry: The last password entered during this connection attempt. Note that  
although the SRM will allow 1, 3, 5, 9, or an infinite number of password attempts, the  
Audit Log will list the last password entered at the login prompt; earlier password  
attempts will not be listed.  
4. Exit Status: The reason for disconnection:  
Exit Command: The caller entered the /X command to exit from the SRM Command  
Mode.  
Invalid Password: The caller did not enter a valid password within the allowed  
number of password attempts.  
Dialing Back: The SRM ended the connection in order to perform a dialback  
operation. For more information on the dialback function, please refer to Section 7.2.4.  
No Answer: The SRM has performed a Dial Back operation, and the Dialback Number  
did not answer.  
Connection Lost: The party on the other end of the phone line has either hung-up or  
unplugged the phone line.  
DTR Drop: The connection was terminated because the SRM dropped the DTR signal,  
did not receive a DTR signal, or detected a bad line.  
No Activity: The connection has timed out because of a lack of data activity. For more  
information on the timeout feature, please refer to Section 5.2.  
7 -6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
UTILITIES  
1. Zero All Activity Counters  
2. Delete Audit Log  
3. Delete Entire Password Directory  
4. Default Parameters  
5. Send Test Message (ESC to Stop)  
6. Upload Parameters  
7. Download Parameters  
8. Pass-Through (Console - Modem)  
Enter Selection,  
Press <Esc> to Abort ...  
Figure 7.2: The Utilities Menu  
7 .6 . Th e Ut ilit ie s Me n u  
The Utilities Menu allows access to a series of command functions that are related to general  
operation and maintenance of the SRM unit. To display the Utilities menu, access the SRM  
Command Mode as described in Section 5.1, then type /Uand press [Enter]. The menu shown  
in Figure 7.2 will appear. The various functions of the Utilities menu are discussed in the  
sections that follow.  
7 . 6 . 1 . Ze r o All Ac t iv it y Co u n t e r s  
This command is used to reset the counters that track connection activity for each password.  
To zero all activity counters, access the Utilities Menu, then type 1, press [Enter], and follow  
the instructions in the submenu.  
To view the password activity counters, access the SRM Command Mode as described in  
Section 5.1, type /D and press [Enter] to display the Password Directory. For more  
information, please refer to Sections 6.4 and 6.5.  
7 . 6 . 2 . De le t e Au d it Lo g  
This command is used to clear all records from the Audit Log. To erase all Audit Log entries,  
access the Utilities menu, type 2and then  
press [Enter] .  
No te : Once the Audit Log has been cleared, the deleted connection activity records  
cannot be recovered.  
7 . 6 . 3 . De le t e En t ir e P a s s w o r d Dir e c t o r y  
This function is used to completely clear the entire password directory. To clear all entries  
from the SRM Password Directory, first access the Utilities Menu as described above. When  
the Utilities Menu appears, type 3, press [Enter], and follow the instructions in the submenu.  
No te : When this function is performed, the entire SRM password directory will be  
cleared. The Password Directory cannot be restored unless parameters have been  
previously saved to an ASCII file as described in Section 8.  
7 -7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
7 . 6 . 4 . De f a u lt P a r a m e t e r s  
This option allows the system administrator to reset the unit to default parameters without  
deleting the Password Directory. To clear all menu selected parameters except the Password  
Directory, and return the SRM-100 to its default configuration, first access the Utilities Menu  
as described in Section 7.6. When the Utilities menu appears, type 4, press [Enter], and  
follow the instructions in the submenu.  
No te s :  
• When the SRM-100 is reset to default parameters, all menu-selected parameters  
will be cleared. Menu selected parameters cannot be recovered unless they have  
been saved to an ASCII text file as described in Section 8.  
• When the "Default Parameters" function is performed via modem, the SRM will  
not immediately reset modem parameters. The unit will reset all other parameters,  
wait for the caller to disconnect, and then reset modem parameters.  
7 . 6 . 5 . Se n d Te s t Me s s a g e  
This option allows the system administrator to send a test message via the Console Port or  
telecommunications line. If the SRM Command Mode has been accessed via the Console Port,  
the Test Message will be sent out the Console Port; if the Command Mode has been accessed  
via modem, the Test Message will be sent via the telecommunications line.  
This Test Message is used to test communication with a remote device that has accessed the  
SRM Command Mode via modem, or to test communication with the local device connected to  
the Console Port. To send the Test Message, proceed as follows:  
1. Access the SRM Command Mode as described in Section 5.1.  
2. When the "SRM>" command prompt appears, type /Uand press [Enter]. The Utilities  
Menu will appear as shown in Figure 7.2.  
3. From the Utilities Menu, type 5and press [Enter].  
a) If you have accessed the SRM Command Mode via the Console Port, the Test  
Message will then be sent out the Console Port.  
b) If you have accessed the SRM Command Mode via modem, the Test Message will  
then be sent out the telecommunications line.  
4. To terminate the Test Message, press the [Esc] key.  
7 . 6 . 6 . Up lo a d P a r a m e t e r s  
This function is used to restore SRM parameters that have been saved to an ASCII text file  
using the Utilities Menu's "Download Parameters" function. To restore saved SRM parameters,  
please refer to the instructions in Section 8.2.  
7 -8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Operation  
7 . 6 . 7 . Do w n lo a d P a r a m e t e r s  
This function is used to save user-selected SRM parameters to an ASCII text file on your PC or  
control device. To save SRM parameters, please refer to the instructions in Section 8.1.  
7 . 6 . 8 . P a s s -Th r o u g h Mo d e (Co n s o le -Mo d e m )  
The Pass-Through Mode allows communication between the device connected to the Console  
Port and the SRM’s modem.  
When the Pass-Through Mode is active, the Console Port can access the modem in order to  
place outbound calls, or to invoke modem AT commands. For a listing of available AT  
Note that when the Command Mode is accessed via modem, the Pass-Through Mode can also  
allow a remote user to access a control device connected to the Console Port.  
To activate the Pass-Through Mode, proceed as follows:  
1. Access the Command Mode as described in Section 5.1.  
2. When the "SRM>" command prompt appears, type /Uand press [Enter]. The Utilities  
Menu will appear as shown in Figure 7.2.  
3. From the Utilities menu, type 8, then press [Enter] and follow the instructions in the  
submenu.  
4. To exit from Pass-Through Mode and return to the Command Mode, type /Xand press  
[Enter].  
7 -9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 . Sa v in g a n d Re s t o r in g P a r a m e t e r s a n d  
P a s s w o r d Dir e c t o r y  
After the SRM-100 has been properly configured and the Password Directory has been defined,  
configuration parameters and the Password Directory can be saved as an ASCII text file. Later,  
if the configuration is accidentally altered, the file can be uploaded to automatically  
reconfigure the unit without the need to manually assign each parameter and password.  
Saved parameters and passwords can also be uploaded to other  
SRM-100 units. This allows rapid set-up when several units will be configured with the same  
parameters and password directory.  
The “Save Parameters” procedure can be performed from any communications program (e.g.  
ProComm, Hyperterminal, etc.), that allows downloading of ASCII files.  
8 .1 . Se n d in g P a r a m e t e r s t o a File  
1. Start your communications program and access the SRM Command Mode as described in  
Section 5.1.  
2. When the command prompt appears, type /Uand press [Enter].  
a) The Utilities Menu will appear. From the Utilities Menu, type 7 and press [Enter].  
The SRM will prompt you to configure your communications program to receive an  
ASCII download.  
b) Set your communications program to receive an ASCII format download, and specify  
a name for a file that will receive the saved parameters (e.g. SRM.PAR).  
c) Make certain to disable your communication program's Line Wrap function. This will  
prevent command lines from being broken in two during transmission.  
3. When the communications program is ready to receive the file, return to the SRM  
Command Mode and press [Enter] to proceed with the download.  
4. The SRM will send a series of ASCII command lines which specify the currently selected  
SRM parameters. Menu selected parameters and the currently defined Password  
Directory will be saved on your hard drive in the file specified in Step 2 above.  
8 -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Saving and Restoring Parameters and Password Directory  
8 .2 . Re s t o r in g Sa v e d P a r a m e t e r s  
Once menu selected parameters and the Password Directory have been saved, the parameters  
file can be uploaded to the SRM to quickly configure the unit without the need to manually  
enter each parameter and password. To restore saved parameters, proceed as follows:  
No te : When the "Upload Parameters" function is performed via modem, the SRM  
will not immediately reset modem parameters. The unit will reset all other  
parameters, wait for the caller to disconnect, and then reset modem parameters.  
1. Start your communications program and access the SRM Command Mode via the Console  
Port, or via modem using the System Password.  
2. When the command prompt appears, type /Uand press [Enter].  
a) The Utilities Menu will appear. From the Utilities Menu, type 6 and press [Enter].  
The SRM will display a message which indicates that the unit is ready to receive the  
parameters file.  
b) Set your communications program to upload an ASCII text file using the file name  
specified in Section 8.1. When the communications program is ready, begin the  
upload procedure.  
3. The saved parameters file will be sent to the SRM-100, and the saved parameters and  
Password Directory will be restored. When the upload is complete, make certain to  
terminate your communication program’s upload mode.  
8 -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A. In t e r f a c e De s c r ip t io n s  
A.1 . Co n s o le P o r t  
Figure A.1: Console Port Interface (DTE)  
A.2 . Mo d e m P o r t  
Figure A.2: Modem Port Interface (DCE)  
Ap x -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Appendices  
B. Sp e c if ic a t io n s  
Compatibility:  
ITU V.42bis, V.42, Enhanced V.34, AT&T V.32terbo, ITU V.32bis,  
V.32, V.22bis, V.22, Bell 212A and 103/113, ITU V.17, Group 3 T.4,  
T.30 and EIA TR-29 Class 2.  
Command Set:  
"AT" Commands  
Error Correction:  
V.42 (LAP-M or MNP 3 & 4) Error Correction.  
Data Compression:  
V.42bis, (4:1 throughput) or MNP 5 (2:1 throughput) Data Compression.  
Modem Port:  
Interface:  
Rates:  
EIA RS232C,/ITU V.24 Equivalent  
300 - 33,600 baud  
Command Buffer:  
Flow Control:  
Ringer Equivalence:  
60 Characters  
None, RTS/CTS, XON/XOFF, Both  
0.3B DOC LN/MDC IC:3  
Console Port:  
Interface:  
RS-232C, DB-9P  
Site ID:  
32 Characters Max.  
System Password:  
Console Port Password:  
16 Characters, Case Sensitive  
16 Characters, Case Sensitive  
User Password Directory:  
Passwords Allowed:  
Password Field:  
100 Max.  
16 Characters, Case Sensitive  
Dialback Field:  
32 Digits  
Power:  
AC Model:  
DC Model:  
115/230 VAC, 50/60 Hz, 10 Watts  
Dual -48 VDC Inputs, 0.1 Amp  
Physical/Environmental:  
Size:  
1.75" x 19" x 6.0" (H x W x D)  
5 Lbs. Shipping Weight  
Weight:  
Temperature:  
Humidity:  
Operating - 0°C to 45°C  
10 - 90% Non-condensing  
Ordering Information:  
SRM-100AC  
115/230 VAC Powered Modem  
-48 VDC Powered Modem  
23" Rack Adapter Kit  
SRM-100DC  
SRM-23R  
Ap x -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Appendices  
C. Cu s t o m e r Se r v ic e  
Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday. When  
calling, please be prepared to give the name and make of the unit, its serial number and a  
description of its symptoms. If the unit should need to be returned for factory repair it must be  
accompanied by a Return Authorization number from Customer Service.  
WTI Customer Service  
5 Sterling  
Irvine, California 92618  
Local Phone: (949) 586-9950  
Toll Free: 1-888-280-7227  
Fax: (949) 457-8138  
Tr a d e m a r k a n d Co p y r ig h t In f o r m a t io n  
WTI and Western Telematic are trademarks of Western Telematic, Inc. All other product names  
mentioned in this publication are trademarks or registered trademarks of their respective  
companies.  
Information and descriptions contained herein are the property of Western Telematic, Inc.  
Such information and descriptions may not be copied disseminated or distributed without the  
express written consent of Western Telematic, Inc.  
© Copyright Western Telematic, Inc. 2001  
April 2001  
Part Number: 13051 Revision: D  
Ap x -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
In d e x  
A
D
AC Power . . . . . . . . . . . . . . . . . . . . . . . . . 4-1  
Activity Counters . . . . . . . . . . . . . . . . . . 6-6, 7-7  
Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6  
Add Name / Password . . . . . . . . . . . . . . . . . . 6-2  
ARQ/Compression . . . . . . . . . . . . . . . . . . . . 4-4  
AT Commands . . . . . . . . . . . . . . . . . . . . . . 7-9  
Audit Log . . . . . . . . . . . . . . . . . . . . . . 5-5, 7-7  
Viewing . . . . . . . . . . . . . . . . . . . . . . . . . 7-5  
Data Bits  
Console Port . . . . . . . . . . . . . . . . . . . . . . 5-4  
Modem . . . . . . . . . . . . . . . . . . . . . . . . . 5-6  
Serial Modem Port. . . . . . . . . . . . . . . . . . . 5-6  
Data Carrier Detect. . . . . . . . . . . . . . . . . . . . 2-1  
Data Compression . . . . . . . . . . . . . . . . . . . . 5-7  
Data Terminal Ready. . . . . . . . . . . . . . . . . . . 2-1  
DC Power . . . . . . . . . . . . . . . . . . . . . . . . . 4-2  
DCD Indicator . . . . . . . . . . . . . . . . . . . . . . 2-1  
Default ARQ/Compression . . . . . . . . . . . . . . . 4-4  
Default Baud Rate  
B
Back Panel Components . . . . . . . . . . . . . . . . . 2-2  
Baud Rate  
Internal Modem . . . . . . . . . . . . . . . . . . . . 4-2  
Modem Port . . . . . . . . . . . . . . . . . . . . . . 4-2  
Default Bits and Parity  
Modem . . . . . . . . . . . . . . . . . . . . . . . . . 5-6  
Serial Modem Port. . . . . . . . . . . . . . . . . . . 5-6  
Baud Rate Sensing . . . . . . . . . . . . . . . . . . . . 7-4  
Bits / Parity  
Modem . . . . . . . . . . . . . . . . . . . . . . . . . 5-6  
Serial Modem Port. . . . . . . . . . . . . . . . . . . 5-6  
Internal Modem . . . . . . . . . . . . . . . . . . . . 4-3  
Serial Modem Port. . . . . . . . . . . . . . . . . . . 4-3  
Default Button. . . . . . . . . . . . . . . . . . . . 2-2, 4-5  
Default Flow Control Format . . . . . . . . . . . . . . 4-3  
Default Parameters . . . . . . . . . . . . . 4-2 to 4-4, 7-8  
Default Rings to Answer . . . . . . . . . . . . . . . . 4-3  
Default Security Mode . . . . . . . . . . . . . . . . . . 4-4  
Delete Audit Log . . . . . . . . . . . . . . . . . . . . . 7-7  
Delete Password Directory . . . . . . . . . . . . . . . 7-7  
Deleting Passwords. . . . . . . . . . . . . . . . 6-3 to 6-5  
Dial Back Attempts . . . . . . . . . . . . . . . . . . . 5-5  
Dial Back Delay . . . . . . . . . . . . . . . . . . . . . 5-5  
Dial Back Numbers. . . . . . . . . . . . . . . . . . . . 7-3  
Password . . . . . . . . . . . . . . . . . . . . . . . . 7-3  
System. . . . . . . . . . . . . . . . . . . . . . . . . . 5-2  
User . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
Dialing Back . . . . . . . . . . . . . . . . . . . . . . . 7-6  
Dialing Out . . . . . . . . . . . . . . . . . . . . . . . . 7-4  
Disconnect. . . . . . . . . . . . . . . . . . . . . . . . . 7-4  
Download Parameters . . . . . . . . . . . . . . . . . . 8-1  
DTR Drop . . . . . . . . . . . . . . . . . . . . . . . . . 7-6  
DTR Indicator. . . . . . . . . . . . . . . . . . . . . . . 2-1  
DTR Signal . . . . . . . . . . . . . . . . . . . . . . . . 5-8  
C
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5  
Clear to Send . . . . . . . . . . . . . . . . . . . . . . . 2-1  
Clock and Calendar. . . . . . . . . . . . . . . . . 5-4, 7-6  
Command Echo . . . . . . . . . . . . . . . . . . . . . . 5-4  
Command Mode . . . . . . . . . . . . . . . . . . . . . 7-1  
Command Mode Access . . . . . . . . . . . . . . . . . 5-1  
Console Port . . . . . . . . . . . . . . . . . . . . . . 5-1  
Modem . . . . . . . . . . . . . . . . . . . . . . . . . 5-2  
Command Port . . . . . . . . . . . . . . . . . . . . . . 2-2  
Compression . . . . . . . . . . . . . . . . . . . . . . . 5-7  
Configuration . . . . . . . . . . . . . . . . . . . 5-1 to 5-8  
Confirmation Prompt  
Suppressing. . . . . . . . . . . . . . . . . . . . . . . 7-4  
Connection Attempts. . . . . . . . . . . . . . . 7-5 to 7-6  
Connection Attempts Capture Mode . . . . . . . . . . 5-5  
Connection Lost . . . . . . . . . . . . . . . . . . . . . 7-6  
Connectors . . . . . . . . . . . . . . . . . . . . . . . . 2-2  
Console Port . . . . . . . . . . . 2-2, 4-5, 5-1, 5-4, Apx-1  
Communication Parameters . . . . . . . . . . . . . 5-4  
Console Port Password . . . . . . . . . . . . . . . 5-4, 7-2  
Counters  
E
Earthing . . . . . . . . . . . . . . . . . . . . . . . 3-1, 4-1  
Edit / Delete from List . . . . . . . . . . . . . . 6-3 to 6-4  
Edit / Delete from Search . . . . . . . . . . . . 6-4 to 6-5  
Editing Passwords . . . . . . . . . . . . . . . . 6-3 to 6-5  
Equipment Racks. . . . . . . . . . . . . . . . . . . . . 4-1  
Error Control . . . . . . . . . . . . . . . . . . . . . . . 5-7  
Exit Command . . . . . . . . . . . . . . . . . . . . . . 7-6  
Exit Status Messages . . . . . . . . . . . . . . . . . . . 7-6  
Zero . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6  
CTS Indicator . . . . . . . . . . . . . . . . . . . . . . . 2-1  
Custom Initialization String. . . . . . . . . . . . . . . 5-7  
Customer Service . . . . . . . . . . . . . . . . . . . Apx-3  
In d e x -1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Index  
F
P
Flow Control Format . . . . . . . . . . . . . . . . 4-3, 5-6  
Parameters  
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . 2-1  
Restoring . . . . . . . . . . . . . . . . . . . . . . . . 8-2  
Saving . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1  
G
Parity  
General Parameters Menu . . . . . . . . . . . . 5-3 to 5-5  
Grounding . . . . . . . . . . . . . . . . . . . . . . 3-1, 4-1  
Console Port . . . . . . . . . . . . . . . . . . . . . . 5-4  
Modem . . . . . . . . . . . . . . . . . . . . . . . . . 5-6  
Serial Modem Port. . . . . . . . . . . . . . . . . . . 4-3  
PASS Indicator . . . . . . . . . . . . . . . . . . . . . . 2-1  
Pass-Through Mode . . . . . . . . . . . . . . . . . . . 7-9  
Password Activity Counters. . . . . . . . . . . . . . . 7-7  
Password Attempts . . . . . . . . . . . . . . . . 5-5 to 7-6  
Password Directory . . . . . . . . . . . . . 6-1 to 6-6, 7-8  
Viewing . . . . . . . . . . . . . . . . . . . . . . . . . 6-5  
Password Entry . . . . . . . . . . . . . . . . . . . . . . 7-6  
Password on Dial Back . . . . . . . . . . . . 5-2, 5-5, 7-3  
Passwords . . . . . . . . . . . . . . . . . . . . . . 6-2, 7-1  
Adding . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
Console Port . . . . . . . . . . . . . . . . . . . . . . 5-4  
Deleting. . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
Duplicate . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
Editing . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
Saving . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
System. . . . . . . . . . . . . . . . . . . . . . . . . . 5-3  
User . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2  
Phone Line . . . . . . . . . . . . . . . . . . . . . . . . 4-6  
Pin-Out . . . . . . . . . . . . . . . . . . . . . . . . . Apx-1  
Port Used . . . . . . . . . . . . . . . . . . . . . . . . . 7-6  
Power Connection. . . . . . . . . . . . . . . . . . 3-1, 4-1  
Power Input . . . . . . . . . . . . . . . . . . . . . . . . 2-2  
Power Switch . . . . . . . . . . . . . . . . . . . . . . . 2-2  
H
Handshake Format . . . . . . . . . . . . . . . . . 4-3, 5-6  
Hang-Up String . . . . . . . . . . . . . . . . . . . . . . 5-7  
Hardware Installation . . . . . . . . . . . . . . 4-1 to 4-6  
I
Ignore DTR . . . . . . . . . . . . . . . . . . . . . 2-1, 5-8  
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . 2-1  
Initialization . . . . . . . . . . . . . . . . . . . . . . . 4-5  
Initialization String . . . . . . . . . . . . . . . . . . . 5-7  
Interface Description . . . . . . . . . . . . . . . . . Apx-1  
Invalid Password . . . . . . . . . . . . . . . . . . . . . 7-6  
L
LED Indicators . . . . . . . . . . . . . . . . . . . . . . 2-1  
Local Echo . . . . . . . . . . . . . . . . . . . . . . . . 5-7  
M
Modem Baud Rate . . . . . . . . . . . . . . . . . . . . 4-2  
Modem Hang-Up String . . . . . . . . . . . . . . . . . 5-7  
Modem Initialization String. . . . . . . . . . . . . . . 5-7  
Modem Line. . . . . . . . . . . . . . . . . . . . . . . . 4-6  
Modem Parameters Menu . . . . . . . . . . . . 5-6 to 5-8  
Modem Port. . . . . . . . . . . . . . . . . 2-2, 4-5, Apx-1  
Modem Reset String . . . . . . . . . . . . . . . . . . . 5-7  
Modem Speaker . . . . . . . . . . . . . . . . . . . 4-4, 5-7  
Q
Quick Start . . . . . . . . . . . . . . . . . . . . 3-1 to 3-4  
Quiet Mode . . . . . . . . . . . . . . . . . . . . . . . . 5-7  
N
Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
No Activity . . . . . . . . . . . . . . . . . . . . . . . . 7-6  
No Activity Timeout . . . . . . . . . . . . . . . . . . . 5-4  
No Answer . . . . . . . . . . . . . . . . . . . . . . . . 7-6  
R
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . 4-1  
RDY Indicator . . . . . . . . . . . . . . . . . . . . . . 2-1  
Real Time Clock . . . . . . . . . . . . . . . . . . 5-4, 7-6  
Request to Send. . . . . . . . . . . . . . . . . . . . . . 2-1  
Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5  
Reset String . . . . . . . . . . . . . . . . . . . . . . . . 5-7  
Reset to Defaults . . . . . . . . . . . . . . . . . . . . . 7-8  
Restoring Parameters . . . . . . . . . . . . . . . . . . 8-2  
Result Codes . . . . . . . . . . . . . . . . . . . . . . . 5-7  
Rings to Answer. . . . . . . . . . . . . . . . . . . 4-3, 5-7  
RTS Indicator . . . . . . . . . . . . . . . . . . . . . . . 2-1  
RXD Indicator . . . . . . . . . . . . . . . . . . . . . . 2-1  
O
ON Indicator . . . . . . . . . . . . . . . . . . . . . . . 2-1  
Operating Modes . . . . . . . . . . . . . . . . . . . . . 7-1  
In d e x -2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SRM-100 - Secure Rack Modem, User's Guide  
Index  
S
U
Save Password . . . . . . . . . . . . . . . . . . . . . . 6-2  
Saving Parameters . . . . . . . . . . . . . . . . . . . . 8-1  
Secure Device. . . . . . . . . . . . . . . . . . . . . . . 4-5  
Security Mode . . . . . . . . . . . . . . . . . . . . 5-5, 7-1  
Default . . . . . . . . . . . . . . . . . . . . . . . . . 4-4  
Send Test Message . . . . . . . . . . . . . . . . . . . . 7-8  
Serial Modem Port . . . . . . . . . . . . . . . . . 2-2, 4-5  
Setting Clock . . . . . . . . . . . . . . . . . . . . . . . 5-4  
SetUp Switches . . . . . . . . . . . . . . . 2-2, 4-2 to 4-5  
Site ID Message . . . . . . . . . . . . . . . . . . . . . 5-4  
Speaker . . . . . . . . . . . . . . . . . . . . . . . . 4-4, 5-7  
Specifications . . . . . . . . . . . . . . . . . . . . . Apx-2  
Stop Bits  
Unit Overview . . . . . . . . . . . . . . . . . . 3-1 to 3-4  
Unsecured Mode . . . . . . . . . . . . . . . . . . . . . 7-1  
Upload Parameters . . . . . . . . . . . . . . . . . . . . 8-2  
User Dial Back Numbers . . . . . . . . . . . . . . . . 6-2  
User Mode . . . . . . . . . . . . . . . . . . . . . . . . . 7-1  
User Name. . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
User Passwords . . . . . . . . . . . . . . . 6-2, 7-1 to 7-2  
Adding . . . . . . . . . . . . . . . . . . . . . . . . . 6-2  
Deleting. . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
Editing . . . . . . . . . . . . . . . . . . . . . . . . . 6-3  
Utilities Menu . . . . . . . . . . . . . . . . 6-6, 7-7 to 7-9  
V
Verbose Response . . . . . . . . . . . . . . . . . . . . 5-7  
Viewing Audit Log . . . . . . . . . . . . . . . . 7-5 to 7-6  
Voltage Selector Switch . . . . . . . . . . . . . . . . . 2-2  
Modem . . . . . . . . . . . . . . . . . . . . . . . . . 5-6  
Serial Modem Port. . . . . . . . . . . . . . . . . . . 5-6  
Suppressing Confirmation Prompt . . . . . . . . . . . 7-4  
Sure? Prompt . . . . . . . . . . . . . . . . . . . . . . . 7-4  
System Dial Back Number . . . . . . . . . . . . . 5-2, 5-4  
System Password . . . . . . . . . . . . . . 5-3, 7-1 to 7-2  
Default . . . . . . . . . . . . . . . . . . . . . . . . . 7-2  
W
Wrap Around . . . . . . . . . . . . . . . . . . . . . . . 7-5  
Z
Zero Activity Counters . . . . . . . . . . . . . . . 6-6, 7-7  
T
Technical Support . . . . . . . . . . . . . . . . . . . Apx-3  
Telco Line . . . . . . . . . . . . . . . . . . . . . . 2-2, 4-6  
Terminal Block . . . . . . . . . . . . . . . . . . . . . . 4-2  
Terse Response . . . . . . . . . . . . . . . . . . . . . . 5-7  
Test Message . . . . . . . . . . . . . . . . . . . . . . . 7-8  
Time / Date Stamp . . . . . . . . . . . . . . . . 7-5 to 7-6  
Timeout  
Console Port . . . . . . . . . . . . . . . . . . . . . . 5-4  
Tone Dialing . . . . . . . . . . . . . . . . . . . . . . . 7-4  
TXD Indicator . . . . . . . . . . . . . . . . . . . . . . 2-1  
In d e x -3  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Whirlpool Clothes Dryer 8562594 User Manual
Whirlpool Dehumidifier DH25G0 User Manual
White Rodgers Burner 668 430 User Manual
White Rodgers Thermostat 100E+56 User Manual
Yamaha DJ Equipment FX500 User Manual
Yamaha Musical Instrument Concert Marimba User Manual
Yamaha Speaker System BBT110S User Manual
Zanussi Pasta Maker 178145 User Manual
Zanussi Washer FR 1250 S User Manual
Zenoah Chainsaw G4200EZ User Manual