Wells Water Dispenser WM TR II User Manual

707  
OPERATION MANUAL  
WATER-MAX II™  
WM-TR II™  
HOT WATER  
DISPENSER  
Includes  
INSTALLATION  
USE & CARE  
IMPORTANT: DO NOT DISCARD THIS MANUAL  
This manual is considered to be part of the appliance and is to be given to the OWNER or  
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of  
this appliance. Additional manuals are available from your WELLS DEALER.  
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR  
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any  
questions  
concerning installation,  
PRINTED IN UNITED STATES OF AMERICA  
p/n 306692 Rev. A ECN-13060  
M707 060418 cps  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
HEAT (AMBER)  
REFILL (AMBER)  
POWER (GREEN)  
HEATER SWITCH  
DELIME  
QUICK-DISCONNECT  
see page 11  
FLOW  
NOZZLE  
3
5
2
1
SATELLITE  
POSITION  
SENSOR  
6
DELIME  
SOLUTION  
BOTTLE  
SATELLITE  
see page 3  
SATELLITE  
CONNECTOR  
7
10  
POWER  
INLET  
NAMEPLATE  
8
WELLS  
11  
DRAIN VALVE  
MOUNTING  
BRACKET  
WATER  
INLET  
FITTING  
13  
9
ADJUSTABLE  
LEG  
12  
DRAIN  
FITTING  
15  
HEATER  
DRAIN  
VALVE  
DRAIN HOSE  
W/ CLAMP  
14  
Fig. 1 Features & Operating Controls - Water Max II™ Hot Water Dispenser  
ITEM DESCRIPTION NOTES  
1
2
3
4
5
6
7
8
HEATER SWITCH  
POWER LIGHT  
REFILL LIGHT  
Controls power to water heater, satellite heater and satellite fill  
Indicates main power available  
Indicates satellite is being refilled from the main tank  
Indicates heater element is energized and water is heating  
Satellite fill device  
HEAT LIGHT  
FLOW NOZZLE  
SATELLITE SWITCH  
Senses if satellite is in position  
SATELLITE CONNECTOR Electrical connector for satellite heater and fill  
NAMEPLATE  
Lists manufacturer, model & serial number, voltage & wattage.  
Supports unit off of counter and allows unit to be leveled  
Non-skid foot resists movement of unit on counter  
9
ADJUSTABLE LEG  
10 POWER INLET  
Electrical power fitting connects here  
Inlet water connects here  
11 INLET FITTING  
12 DRAIN FITTING  
13 MOUNTING BRACKET  
Drain assembly connects here  
Stabilizes drain valve, provides place to store drain hose  
14 HEATER DRAIN VALVE Allows main water heater tank to be drained for service  
15 DRAIN HOSE w/CLAMP Control and direct drain stream  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES & OPERATING CONTROLS (continued)  
SATELLITE ASSEMBLY  
WATER LEVEL  
SENSOR  
S3  
COVER HOLDER  
CLIPS  
S2  
COVER  
S1  
WELLS  
HANDLE  
S6  
S8  
FAUCET  
S5  
GUARD  
NAMEPLATE  
DISPENSE  
S4  
FAUCET  
SATELLITE  
CONNECTOR  
S7  
BACK VIEW  
FRONT VIEW  
Fig. 2 Features & Operating Controls - Water Max II™ 5 Gallon Satellite  
ITEM DESCRIPTION  
NOTES  
S1 COVER  
Forms fill funnel, allows access to tank for service  
S2 COVER HOLDING CLIPS Retains cover in place  
S3 WATER LEVEL SENSOR Maintains water level in tank  
S4 DISPENSE FAUCET  
S5 FAUCET GUARD  
S6 HANDLE  
Dispense hot water here  
Helps to protect faucet from damage  
Used to install/remove satellite on heater unit  
S7 SATELLITE CONNECTOR Electrical connector for satellite heater and fill  
S8 NAMEPLATE Lists manufacturer, model & serial number, voltage & wattage.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
(FRONT)  
MOUNTING  
BRACKET  
L
L
DRAIN  
ASSEMBLY  
ELECTRIC  
SERVICE  
INLET  
WATER INLET  
FITTING  
DRAIN  
FITTING  
L
L
(REAR)  
BOTTOM VIEW  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (continued)  
CAUTION:  
PLUMBING LINE CONNECTION  
RISK OF DAMAGE  
If power has been run to the dispenser, verify that the circuit breaker is  
turned OFF, and that the POWER SWITCH is in the OFF [O] position.  
DO NOT connect or energize  
this appliance until all Installation  
Instructions are read and followed.  
Damage to the dispenser will  
occur if these instructions are  
not followed.  
Water-Max II™ must be connected to a potable water supply. Connect  
to a cold water line only. Connecting to a hot water line will damage the  
inlet water valve.  
NOTICE:  
WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY  
CONNECTED TO A POTABLE WATER SUPPLY SHALL BE SIZED,  
INSTALLED AND MAINTAINED ACCORDING TO FEDERAL, STATE,  
AND LOCAL ORDINANCES.  
IMPORTANT: Water supply  
MUST be a minimum of 1/4”  
line, and MUST be capable of  
supplying 25 p.s.i. AT ALL  
TIMES during the operation of  
the dispenser.  
Minimum 1/4” copper or flex tubing supply line (3/8” minimum if run  
from main supply exceeds 12 feet) with 1/4” female flare fitting.  
Minimum 25 psi / maximum 75 psi water pressure at full flow.  
The installation of a SHUTOFF VALVE (must be provided by plumbing  
installer) on the incoming water line is required. A 1/4 turn ball valve is  
recommended to minimize restricting the water flow during operation.  
Installation of a PRESSURE REGULATOR and WATER HAMMER  
ARRESTOR (to be provided by plumbing installer) on the incoming  
water line is recommended.  
Clean the incoming waterline: Run water through the line into a sink or  
bucket to flush any foreign particles or debris from the waterline.  
Assemble incoming water line to the inlet fitting. Turn on water supply  
valve and check for leaks.  
If a pressure regulator is installed, adjust pressure to 40 p.s.i.  
Fig. 3 1/4 Turn Ball Valve  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (continued)  
ELECTRICAL INSTALLATION  
CAUTION:  
SHOCK HAZARD  
NOTICE:  
A DEDICATED CIRCUIT OF AT LEAST 40 AMPS IS REQUIRED.  
Removal of any exterior panel  
will result in exposed electrical  
circuits. Electrical connection  
must be performed by a  
qualified technician only.  
Use care whenever working  
around exposed electrical  
circuits.  
WIRING AND CONNECTIONS MUST BE INSTALLED AND  
MAINTAINED IN COMPLIANCE WITH  
FEDERAL, STATE, AND LOCAL ORDINANCES.  
The dispenser is factory configured for either 208 volts or 240 volts.  
The voltage configuration is NOT field convertible.  
DO NOT connect unit to electric power until water supply is connected  
and turned on.  
IMPORTANT:  
Contact a licensed electrician  
co connect electric power to  
the dispenser.  
Be sure HEATER SWITCH is OFF (O) before connecting unit to electric  
power.  
IMPORTANT:  
Damage due to being  
connected to the wrong  
voltage or phase is NOT  
covered by warranty.  
IMPORTANT:  
Supply voltage must  
correspond to the nameplate  
voltage of the unit. Connection  
to the wrong voltage can result  
in equipment damage or  
reduced performance.  
Such damage is not covered  
by warranty.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (continued)  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
Water-Max II™ is used to dispense hot water for food preparation. The  
SATELLITE TANK stores five gallons of hot water for immediate use.  
WARNING:  
BURN HAZARD  
INSTALLING OR REMOVING SATELLITE TANK  
Water-Max™ is designed to  
operate with a matching 5 gal.  
satellite water tank only.  
Do not hold anything other  
than the matching satellite  
under the dispensing nozzle.  
Splashing hot water will cause  
serious burns.  
Drain all water from SATELLITE before attempting to remove from unit.  
Press the HEATER SWITCH to OFF ( O )  
Be sure the COVER is properly installed on the SATELLITE  
Install or remove SATELLITE on Water-Max II™ shelf by lifting up on  
satellite faucet guard.  
When installing the tank, make sure that the tank is properly positioned,  
that the connector is seated, and that the dispensing nozzle lowered  
into position in the satellite cover.  
Press the HEATER SWITCH to ON ( I ). Amber REFILL light will glow  
and hot water will begin filling the satellite after 15 - 20 seconds.  
Place an appropriate container under the faucet. Being careful not to  
overflow the container, pull the faucet handle to dispense hot water.  
GENERAL GUIDELINES  
NEVER hold or place  
anything, other than the proper  
satellite, under the dispense  
nozzle. Draw water only from  
the hot water faucet of the  
satellite water tank.  
DISPENSE  
NOZZLE  
OFF  
ON  
NEVER attempt to remove or  
carry a satellite while full of  
water.  
HOT WATER  
FAUCET  
NEVER attempt to operate  
Water-Max II™ without the  
cover properly installed on the  
satellite  
CAUTION:  
Hot Surface  
Fig. 5 Water-Max™ Operation  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
To Keep Water in Satellite Hot  
Leave the heater switch ON. The satellite has an internal heater to  
maintain the tank temperature, and will remain ready to dispense hot  
water.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING INSTRUCTIONS  
DAILY CLEANING  
CAUTION:  
PRECAUTIONS: Press HEATER SWITCH to OFF ( O ).  
Drain all water from SATELLITE.  
BURN HAZARD  
Remove satellite from Water-Max II™.  
Water in satellite is extremely  
hot. Use care when draining.  
FREQUENCY:  
TOOLS:  
Minimum - Daily, or as required  
Soft Cloth, Soft Bristle Brush  
CAUTION:  
HOT SURFACES  
TANK LID  
Exposed surfaces can be hot  
to the touch and may cause  
burns.  
CAUTION:  
EQUIPMENT  
DAMAGE  
HANDLE &  
BONNET  
TANK  
FAUCET  
DO NOT SUBMERGE  
SATELLITE IN WATER!  
FAUCET  
BODY  
IMPORTANT:  
DO NOT use bleach,  
abrasive cleansers or  
cleansers containing  
chlorides.  
SCREEN  
Wipe down the exterior of the Water-MaxII™ with a soft damp cloth.  
Use a soft bristle brush to remove any calcium or lime build-up on the  
end of the dispensing nozzle. Wipe dispensing nozzle clean with a soft  
damp cloth.  
Remove SATELLITE COVER.  
Wipe satellite FAUCET, and interior and exterior of tank with a soft  
damp cloth. DO NOT SUBMERGE SATELLITE IN WATER!  
Fill satellite with cool, clean water. Check operation of faucet.  
If the faucet leaks:  
Drain tank  
Disassemble faucet by unscrewing bonnet from faucet body.  
Clean or repair faucet as necessary.  
Reassemble bonnet on faucet body.  
Reinstall SATELLITE COVER.  
Drain any remaining water from satellite, re-install on Water-Max II™.  
Press HEATER SWITCH to ON ( I ) and test for proper operation.  
Procedure is complete.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING INSTRUCTIONS (continued)  
FIRST AID  
EYES: In case of contact,  
immediately flush with warm  
water for 15 minutes.  
Contact a physician if  
irritation persists.  
SKIN: Wash with soap and  
water.  
Contact a physician if  
irritation persists.  
INGESTION: If swallowed,  
drink plenty of water and  
contact a physician  
KAY CHEMICAL CO.  
EMERGENCY PHONE  
(800) 304-0824  
INGREDIENTS  
Organic acids. Non-toxic  
when used as directed.  
For description of features  
refer to page 2.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING INSTRUCTIONS (continued  
CAUTION  
Burn Hazard  
Water in Water-Max II™ is  
EXTREMELY HOT! Wear  
appropriate heat protective  
clothing when draining water  
from unit.  
IMPORTANT:  
Never drain internal tank with  
HEATER SWITCH ON.  
Tank heating element will be  
damaged if allowed to  
operate without water.  
For description of features  
refer to page 2.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING INSTRUCTIONS (continued)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYMPTOM  
POSSIBLE CAUSE  
SUGGESTED REMEDY  
Power light not lit  
Circuit breaker off or tripped  
Reset circuit breaker  
Satellite not properly positioned  
on shelf  
Set satellite in proper position  
Verify water supply is fully on  
Satellite does not fill  
Inlet solenoid strainer plugged -  
clean strainer  
Low water in main tank  
Internal damage - contact  
Authorized Wells Service Agency  
Contact Authorized Wells Service  
Agency  
Satellite suffers excessive fill time Improper internal adjustments  
Satellite not properly positioned  
on shelf  
Set satellite in proper position -  
verify connector securely seated  
Dispensed water not hot enough  
Water temp thermostat not set  
Contact Authorized Wells Service  
Agency  
Dispense thermostat set too low  
Tripped circuit breaker  
Main tank does not heat  
Contact Authorized Wells Service  
Agency  
Internal damage  
There are no user serviceable components in the appliance. In all cases of damage or component  
malfunction, contact your Authorized Wells Service Agency for repairs.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRINTED IN UNITED STATES OF AMERICA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Whirlpool Washer Dryer W10376238C User Manual
Williams Sound DJ Equipment PPA R35N User Manual
Williams Sound Electronic Keyboard Sonata 88 User Manual
Wilton Lathe 63300 User Manual
Winegard Satellite TV System SK 7002 User Manual
Xerox All in One Printer 4260 XF User Manual
X Micro Tech Headphones BT400GII User Manual
Xpelair Air Conditioner IDH1 8 User Manual
Zanussi Washer Dryer ZWF 1434W User Manual
Zenith Speaker System XBS344 User Manual