INTRODUCTION
1
Download from Www.Somanuals.com. All Manuals Search And Download.
4
HEAT (AMBER)
REFILL (AMBER)
POWER (GREEN)
HEATER SWITCH
DELIME
QUICK-DISCONNECT
see page 11
FLOW
NOZZLE
3
5
2
1
SATELLITE
POSITION
SENSOR
6
DELIME
SOLUTION
BOTTLE
SATELLITE
see page 3
SATELLITE
CONNECTOR
7
10
POWER
INLET
NAMEPLATE
8
WELLS
11
DRAIN VALVE
MOUNTING
BRACKET
WATER
INLET
FITTING
13
9
ADJUSTABLE
LEG
12
DRAIN
FITTING
15
HEATER
DRAIN
VALVE
DRAIN HOSE
W/ CLAMP
14
Fig. 1 Features & Operating Controls - Water Max II™ Hot Water Dispenser
ITEM DESCRIPTION NOTES
1
2
3
4
5
6
7
8
HEATER SWITCH
POWER LIGHT
REFILL LIGHT
Controls power to water heater, satellite heater and satellite fill
Indicates main power available
Indicates satellite is being refilled from the main tank
Indicates heater element is energized and water is heating
Satellite fill device
HEAT LIGHT
FLOW NOZZLE
SATELLITE SWITCH
Senses if satellite is in position
SATELLITE CONNECTOR Electrical connector for satellite heater and fill
NAMEPLATE
Lists manufacturer, model & serial number, voltage & wattage.
Supports unit off of counter and allows unit to be leveled
Non-skid foot resists movement of unit on counter
9
ADJUSTABLE LEG
10 POWER INLET
Electrical power fitting connects here
Inlet water connects here
11 INLET FITTING
12 DRAIN FITTING
13 MOUNTING BRACKET
Drain assembly connects here
Stabilizes drain valve, provides place to store drain hose
14 HEATER DRAIN VALVE Allows main water heater tank to be drained for service
15 DRAIN HOSE w/CLAMP Control and direct drain stream
2
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES & OPERATING CONTROLS (continued)
SATELLITE ASSEMBLY
WATER LEVEL
SENSOR
S3
COVER HOLDER
CLIPS
S2
COVER
S1
WELLS
HANDLE
S6
S8
FAUCET
S5
GUARD
NAMEPLATE
DISPENSE
S4
FAUCET
SATELLITE
CONNECTOR
S7
BACK VIEW
FRONT VIEW
Fig. 2 Features & Operating Controls - Water Max II™ 5 Gallon Satellite
ITEM DESCRIPTION
NOTES
S1 COVER
Forms fill funnel, allows access to tank for service
S2 COVER HOLDING CLIPS Retains cover in place
S3 WATER LEVEL SENSOR Maintains water level in tank
S4 DISPENSE FAUCET
S5 FAUCET GUARD
S6 HANDLE
Dispense hot water here
Helps to protect faucet from damage
Used to install/remove satellite on heater unit
S7 SATELLITE CONNECTOR Electrical connector for satellite heater and fill
S8 NAMEPLATE Lists manufacturer, model & serial number, voltage & wattage.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
(FRONT)
MOUNTING
BRACKET
L
L
DRAIN
ASSEMBLY
ELECTRIC
SERVICE
INLET
WATER INLET
FITTING
DRAIN
FITTING
L
L
(REAR)
BOTTOM VIEW
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION (continued)
CAUTION:
PLUMBING LINE CONNECTION
RISK OF DAMAGE
If power has been run to the dispenser, verify that the circuit breaker is
turned OFF, and that the POWER SWITCH is in the OFF [O] position.
DO NOT connect or energize
this appliance until all Installation
Instructions are read and followed.
Damage to the dispenser will
occur if these instructions are
not followed.
Water-Max II™ must be connected to a potable water supply. Connect
to a cold water line only. Connecting to a hot water line will damage the
inlet water valve.
NOTICE:
WATER PIPE CONNECTIONS AND FIXTURES DIRECTLY
CONNECTED TO A POTABLE WATER SUPPLY SHALL BE SIZED,
INSTALLED AND MAINTAINED ACCORDING TO FEDERAL, STATE,
AND LOCAL ORDINANCES.
IMPORTANT: Water supply
MUST be a minimum of 1/4”
line, and MUST be capable of
supplying 25 p.s.i. AT ALL
TIMES during the operation of
the dispenser.
Minimum 1/4” copper or flex tubing supply line (3/8” minimum if run
from main supply exceeds 12 feet) with 1/4” female flare fitting.
Minimum 25 psi / maximum 75 psi water pressure at full flow.
The installation of a SHUTOFF VALVE (must be provided by plumbing
installer) on the incoming water line is required. A 1/4 turn ball valve is
recommended to minimize restricting the water flow during operation.
Installation of a PRESSURE REGULATOR and WATER HAMMER
ARRESTOR (to be provided by plumbing installer) on the incoming
water line is recommended.
Clean the incoming waterline: Run water through the line into a sink or
bucket to flush any foreign particles or debris from the waterline.
Assemble incoming water line to the inlet fitting. Turn on water supply
valve and check for leaks.
If a pressure regulator is installed, adjust pressure to 40 p.s.i.
Fig. 3 1/4 Turn Ball Valve
6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION (continued)
ELECTRICAL INSTALLATION
CAUTION:
SHOCK HAZARD
NOTICE:
A DEDICATED CIRCUIT OF AT LEAST 40 AMPS IS REQUIRED.
Removal of any exterior panel
will result in exposed electrical
circuits. Electrical connection
must be performed by a
qualified technician only.
Use care whenever working
around exposed electrical
circuits.
WIRING AND CONNECTIONS MUST BE INSTALLED AND
MAINTAINED IN COMPLIANCE WITH
FEDERAL, STATE, AND LOCAL ORDINANCES.
The dispenser is factory configured for either 208 volts or 240 volts.
The voltage configuration is NOT field convertible.
DO NOT connect unit to electric power until water supply is connected
and turned on.
IMPORTANT:
Contact a licensed electrician
co connect electric power to
the dispenser.
Be sure HEATER SWITCH is OFF (O) before connecting unit to electric
power.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT:
Supply voltage must
correspond to the nameplate
voltage of the unit. Connection
to the wrong voltage can result
in equipment damage or
reduced performance.
Such damage is not covered
by warranty.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION (continued)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Water-Max II™ is used to dispense hot water for food preparation. The
SATELLITE TANK stores five gallons of hot water for immediate use.
WARNING:
BURN HAZARD
INSTALLING OR REMOVING SATELLITE TANK
Water-Max™ is designed to
operate with a matching 5 gal.
satellite water tank only.
Do not hold anything other
than the matching satellite
under the dispensing nozzle.
Splashing hot water will cause
serious burns.
Drain all water from SATELLITE before attempting to remove from unit.
Press the HEATER SWITCH to OFF ( O )
Be sure the COVER is properly installed on the SATELLITE
Install or remove SATELLITE on Water-Max II™ shelf by lifting up on
satellite faucet guard.
When installing the tank, make sure that the tank is properly positioned,
that the connector is seated, and that the dispensing nozzle lowered
into position in the satellite cover.
Press the HEATER SWITCH to ON ( I ). Amber REFILL light will glow
and hot water will begin filling the satellite after 15 - 20 seconds.
Place an appropriate container under the faucet. Being careful not to
overflow the container, pull the faucet handle to dispense hot water.
GENERAL GUIDELINES
NEVER hold or place
anything, other than the proper
satellite, under the dispense
nozzle. Draw water only from
the hot water faucet of the
satellite water tank.
DISPENSE
NOZZLE
OFF
ON
NEVER attempt to remove or
carry a satellite while full of
water.
HOT WATER
FAUCET
NEVER attempt to operate
Water-Max II™ without the
cover properly installed on the
satellite
CAUTION:
Hot Surface
Fig. 5 Water-Max™ Operation
Exposed surfaces can be hot
to the touch and may cause
burns.
To Keep Water in Satellite Hot
Leave the heater switch ON. The satellite has an internal heater to
maintain the tank temperature, and will remain ready to dispense hot
water.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS
DAILY CLEANING
CAUTION:
PRECAUTIONS: Press HEATER SWITCH to OFF ( O ).
Drain all water from SATELLITE.
BURN HAZARD
Remove satellite from Water-Max II™.
Water in satellite is extremely
hot. Use care when draining.
FREQUENCY:
TOOLS:
Minimum - Daily, or as required
Soft Cloth, Soft Bristle Brush
CAUTION:
HOT SURFACES
TANK LID
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
EQUIPMENT
DAMAGE
HANDLE &
BONNET
TANK
FAUCET
DO NOT SUBMERGE
SATELLITE IN WATER!
FAUCET
BODY
IMPORTANT:
DO NOT use bleach,
abrasive cleansers or
cleansers containing
chlorides.
SCREEN
Wipe down the exterior of the Water-MaxII™ with a soft damp cloth.
Use a soft bristle brush to remove any calcium or lime build-up on the
end of the dispensing nozzle. Wipe dispensing nozzle clean with a soft
damp cloth.
Remove SATELLITE COVER.
Wipe satellite FAUCET, and interior and exterior of tank with a soft
damp cloth. DO NOT SUBMERGE SATELLITE IN WATER!
Fill satellite with cool, clean water. Check operation of faucet.
If the faucet leaks:
Drain tank
Disassemble faucet by unscrewing bonnet from faucet body.
Clean or repair faucet as necessary.
Reassemble bonnet on faucet body.
Reinstall SATELLITE COVER.
Drain any remaining water from satellite, re-install on Water-Max II™.
Press HEATER SWITCH to ON ( I ) and test for proper operation.
Procedure is complete.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS (continued)
FIRST AID
EYES: In case of contact,
immediately flush with warm
water for 15 minutes.
Contact a physician if
irritation persists.
SKIN: Wash with soap and
water.
Contact a physician if
irritation persists.
INGESTION: If swallowed,
drink plenty of water and
contact a physician
KAY CHEMICAL CO.
EMERGENCY PHONE
(800) 304-0824
INGREDIENTS
Organic acids. Non-toxic
when used as directed.
For description of features
refer to page 2.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS (continued
CAUTION
Burn Hazard
Water in Water-Max II™ is
EXTREMELY HOT! Wear
appropriate heat protective
clothing when draining water
from unit.
IMPORTANT:
Never drain internal tank with
HEATER SWITCH ON.
Tank heating element will be
damaged if allowed to
operate without water.
For description of features
refer to page 2.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS (continued)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Power light not lit
Circuit breaker off or tripped
Reset circuit breaker
Satellite not properly positioned
on shelf
Set satellite in proper position
Verify water supply is fully on
Satellite does not fill
Inlet solenoid strainer plugged -
clean strainer
Low water in main tank
Internal damage - contact
Authorized Wells Service Agency
Contact Authorized Wells Service
Agency
Satellite suffers excessive fill time Improper internal adjustments
Satellite not properly positioned
on shelf
Set satellite in proper position -
verify connector securely seated
Dispensed water not hot enough
Water temp thermostat not set
Contact Authorized Wells Service
Agency
Dispense thermostat set too low
Tripped circuit breaker
Main tank does not heat
Contact Authorized Wells Service
Agency
Internal damage
There are no user serviceable components in the appliance. In all cases of damage or component