Wegener Communications Home Theater Server DTV742 User Manual

DTV742 Installation Quick Start Guide  
The Wegener Model DTV742 8VSB 4-Channel Multiplexor receives VHF/UHF broadcast HDTV signals and provides output ASI  
streams for connection to cable system QAM modulators. This guide provides information for setting up and operating the DTV742.  
Additional information may be found on the Wegener web site at www.wegener.com/  
In addition to this guide, your box should include:  
1. DTV742 8VSB 4-Channel Multiplexor  
2. Power cord  
3. UL safety sheet  
Front and Rear Panel View  
1
2
3
4
5
6
Connector/Pin-out Information  
Rear-Panel Connector Descriptions  
Connector  
Ref Designation  
Type  
Signal Name  
Description  
1
RF In 1, 2, 3, & 4  
Type F  
RF IN 1, RF IN 2, RF IN 3, & RF IN 4 From VHF/UHF Antenna  
ASI OUT 1, ASI OUT 2, ASI OUT 3,  
& ASI Out 2  
To Advanced Cable Channel  
Groomer, DTV700, or ASI Mux  
To LAN – for Web Interface  
Control  
2
ASI Out 1, 2, 3, & 4 BNC  
3
Ethernet  
RJ-45 jack  
Ethernet_In & Out  
4
5
6
Terminal  
Relays  
115/230 VAC  
DB-9 female  
DB-9 female  
IEC receptacle  
RxD (output) & TxD (input)  
Alarm, Warning, & Contact Closures To Alarm Monitoring  
AC Line In To AC Power Outlet  
To Local Terminal  
Status Relays Signals(Ref 4)  
LED Indicator Descriptions  
Pin # Function  
LED  
Description  
LED  
Description  
Close on Alarm or  
power failure  
9
ON – Tracking carrier  
OFF – No carrier  
ON – Tracking carrier  
OFF – No carrier  
RF 1  
RF 2  
4
8
3
6
1
7
2
5
Alarm COM  
Close on Warning  
Warning COM  
Open on Warning  
Not used  
Open on Alarm  
Not used  
Ground  
ON - Tracking carrier  
OFF – No carrier  
ON – See LCD / web  
ON – Tracking carrier  
OFF – No carrier  
RF 3  
RF 4  
ASI OUT  
LOCK  
ON – ASI output active  
OFF – No ASI output  
WARNING browser for details  
OFF – No Warnings  
ON – See LCD / web  
browser for details  
OFF – No alarms  
LAN  
BLINKS – parameter is being  
ACTIVITY changed via browser or SNMP  
ALARM  
Program and PSIP Processing  
The unit tunes and demodulates 8VSB ATSC broadcast signals which are converted to ASI output transport  
streams. Selected programs and PSIP data received are passed through to the output ASI ports. PSIP  
processing may be enabled or disabled.  
800057-02 Rev. A  
Page 1 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main-level Screens  
Second-level Screens  
Input Setup  
2nd-level RF Input  
RF Input X  
Input Setup...  
Where X is the RF port number.  
Press ENT to go to the third-level Input Setup Screens below and  
use the 5 or 6keys to select <ON> or <OFF>, adding or  
removing this program to/from the output stream. Press ENT  
again to confirm.  
Press the ENT key to bring up the second-level Program  
Input screen.  
Press the 4 key to go to Program Status.  
Press the 4 key to go to the next RF Input screen (1 through 4).  
Press the ESC key to return to the Input Setup screen.  
Press the 3 key to go to Clear Errored Seconds (if counter is  
non-zero) or Alarms/Warnings.  
3rd-level Tuner Enable  
Press the ESC key to go to the Home Screen.  
Tuner Enable:  
ON  
Press the ENT key to toggle between ON and OFF, enabling or  
disabling the tuner.  
Press the 4 key to go to the Channel Number Selection screen.  
Press the ESC key to return to the second-level RF Input screen.  
3rd-level Channel Number Selection  
Channel Number: XX  
Where XX is the current channel number.  
Press ENT to enter the edit mode and use the 5 or 6keys to  
change the channel number. Press ENT again to confirm your  
selection or ESC to cancel changes.  
Press the 4 key to go to the RF Standard screen.  
Press the 3 key to go to the Tuner Enable screen.  
Press the ESC key to return to the second-level RF Input screen.  
3rd-level RF Standard  
RF Standard:  
Broadcast  
Press ENT and use the 5 or 6keys to toggle the RF Standard  
between Broadcast and Cable. Press ENT again to confirm your  
selection or ESC to cancel changes.  
Press the 3 key to go to the Channel Selection screen.  
Press the ESC key to return to the second-level RF Input screen.  
800057-02 Rev. A  
Page 3 of 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
May 24, 2003  
Main-level Screens  
Second-level Screens  
2nd -level Program Status  
Program Status  
Input Number:X  
Program Status...  
where X is the input port number.  
Press the ENT key to view the second-level program status  
screens.  
Press the ENT key to go to the third-level program status screen.  
Press the 4 key to go to the next input (1 through 4).  
Press the 4 key to go to Panel Help Timeout.  
Press the 3 key to go to Input Setup.  
Press the ESC key to return to the main-level Program Status  
screen.  
Press the ESC key to go to the Home Screen.  
3rd-level Program Status  
ProgIn XXXXX AAAAAAA  
Out:Y  
BBBBBBB  
where XXXXX is the program number at input, AAAAAAA is the  
service descriptor for the program, Y is the ASI output port, and  
BBBBBBB is the available audio on the input for the program (AC-  
3, MPEG, or MPG/AC3).  
Press the ESC key to return to the 2nd-level Program Status screen.  
Front-panel Help Timeout  
Panel Help Timeout  
10  
Press ENT and then the 5 or 6keys to select the front-  
panel help message timeout. Values of 3, 5, 10, 30, or 60  
seconds, or No Timeout may be selected.  
Press the ENT key to confirm the selection or ESC to cancel  
changes.  
Press the 4 key to go to IP Setup.  
Press the 3 key to go to Program Status.  
Press the ESC key to go to the Home Screen.  
800057-02 Rev. A  
Page 4 of 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
May 24, 2003  
Main-level Screens  
Second-level Screens  
IP Setup  
IP Setup...  
IP Address Selection  
IP Address:  
0.0.0.0  
Press the ENT key to go to IP Address Selection.  
Press the 4 key to go to Reset Unit.  
Press the ENT key and then press the arrow keys to change the IP  
address. Press the ENT key to confirm the selection or ESC to  
cancel changes.  
Press the 3 key to go to Panel Help Timeout.  
Press the ESC key to go to the Home Screen.  
Press the 4 key to go to the Netmask Selection.  
Press the ESC key to go to IP Setup.  
Netmask Selection  
Netmask:  
255.255.0.0  
Press the ENT key and then press the arrow keys to change the  
Netmask. Press the ENT key to confirm the selection or ESC to  
cancel changes.  
Press the 4 key to go to Gateway Selection.  
Press the 3 key to go to IP Address Selection.  
Press the ESC key to go to IP Setup.  
Gateway Selection  
Gateway:  
0.0.0.0  
Press the ENT key and then press the arrow keys to change the  
Gateway. Press the ENT key to confirm the selection or ESC to  
cancel changes.  
Press the 3 key to go to Netmask Selection.  
Press the ESC key to go to IP Setup.  
Unit Reset  
Reset Unit...  
Press the ENT key to reset the unit and start the bootloader.  
Press the 3 key to go to IP Setup.  
Press the ESC key or 4 to go to the Home Screen.  
Web Browser User Interface  
In addition to the front panel, the user may control and monitor the unit using the rear-panel Ethernet connection. Before using the  
Ethernet connection, the appropriate IP address, netmask, and gateway must be selected via the front-panel interface. There are two  
basic methods of using the Ethernet connection – with a directly connected PC or with a LAN connection.  
Locally connected PC –  
Connect the DTV744 Ethernet connection to the Ethernet network connector on the PC using a crossover RJ-45 cable (8 pins).  
Set the DTV744 IP Setup as follows: IP Address: 172.016.100.020  
Gateway: 000.000.000.000  
Netmask: 255.255.000.000  
Set the PC IP address as follows:1  
IP Address: 172.016.100.001  
Subnet Mask: 255.255.000.000  
Connect to the DTV742 using the web browser instructions below.  
LAN Connection –  
Connect the DTV742 Ethernet connection to the LAN using a normal RJ-45 cable (8 pins). Set the DTV744 IP Address, Netmask,  
and Gateway as directed by your network administrator. Use any PC on the LAN to connect to the DTV744 using the web browser  
instructions below.  
1 To change the PC IP address, go to the Settings, Control Panel and double click on the Network icon. Select Configuration, TCP/IP protocol, and click on the  
Properties box. Click on Specify IP Address and set the IP Address and Subnet Mask as indicated. Click OK to restart the PC with the new values.  
800057-02 Rev. A  
Page 5 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Web Browser –  
Using the web browser of your choice, set the Address to http://nnn.nnn.nnn.nnn where nnn.nnn.nnn.nnn is the IP address of  
the unit to be controlled. Each unit on the network must have a unique address. You should see the pages below when connected  
to the unit. (Be sure that your screen resolution is set to at least 1024x768 so that all items are visible. Lower resolutions will  
prevent you from viewing all the available tabs.) You may select which page to view by clicking on the Control and Status, Stream  
Information, Unit Configuration, Config In, Config Out (1, 2, 3, or 4), or Q&A/Help tabs.  
The Control and Status tab (shown below) allows you to select the channel number for the RF input. The status section provides  
signal status.  
800057-02 Rev. A  
Page 6 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Stream Information tab below shows input and output status. No user inputs are located on this screen.  
The Unit Configuration tab below shows the current configuration in use and allows storage and loading of 10 separate  
configurations. A configuration is the set of all user settable items (inputs and outputs) in the unit.  
800057-02 Rev. A  
Page 7 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Config In tab below provides the interface for selecting the RF Input and Program numbers that will be used in all four of the  
DTV742’s multiplexors.  
800057-02 Rev. A  
Page 8 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Config Out tabs (Config Out 1 illustrated below) provide the interface for selecting programs for each of the ASI outputs. A  
separate tab is used for each output (1, 2, 3, and 4).  
800057-02 Rev. A  
Page 9 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Q&A/Help tab (shown below) provides answers to commonly asked questions about the DTV744.  
800057-02 Rev. A  
Page 10 of 11  
May 24, 2003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notices  
Environmental Operating Conditions & Physical Specifications  
Indoor  
Use  
Up to 2000 meters  
Altitude  
10 o C to 40 o  
C
Temperature Range  
80% for temperatures up to 31o C decreasing linearly to 50% relative  
Relative Humidity (max.)  
humidity as 40o C.  
10.6 pounds or 4.81 kilograms  
Weight  
3.5”x 19”x 10.5” or 88.9 mm x 482.6 mm x 266.7 mm  
90-132Vac & 175-264Vac, 43 Watt, 50/60 Hz  
Dimensions (H x W x D)  
Input Power Rating  
Elevated Operating Ambient  
If equipment is installed in a closed or multi-unit rack assembly, the operating ambient of the rack may be greater than the room ambient. Therefore, considerations  
should be given to the TMRA, or Temperature inside the Mounting Rack, and not just inside the room.  
Reduced Air Flow  
Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised.  
Mechanical Loading  
Mounting of equipment in a rack should be such that a hazardous condition is not achieved due to uneven loading. This unit is not very heavy, but total rack loading  
should be considered.  
Circuit Overloading  
Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over-current protection  
and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.  
Reliable Earthing  
Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the  
Branch (use of power strips).  
Desktop Installation  
To set up the DTV735 in a desktop environment, place it on a flat surface where it will not be subject to being hit or pushed, and will not have anything spilled or  
dropped on it. Also, the cables connected to the unit should be routed so they are not hit or pulled, which might cause damage to the connectors or to the unit itself.  
Additionally, there should be sufficient flow of cool air so the unit stays within its operating parameters.  
Rack Installation  
When installed in an equipment rack, it is best that the DTV735 be supported by angle brackets or cross supports. These should be screwed or bolted securely to the  
equipment rack, and be capable of supporting the unit and its connecting cables. Do NOT install the unit if you have doubts about the unit being safely supported. There  
are also 4 holes in the front brackets, which are designed to accept screws for further anchoring. It is also essential that these brackets be used so the unit cannot be  
moved forward and fall from the rack. It is always best to install the angle brackets or cross-members before setting the unit in place. Then, prior to installing cables,  
put anchored screws or bolts-and-nuts into place on the front brackets. Failure to do this can lead to pushing the unit out the front of the rack in later steps.  
Warranty  
The following warranty applies to all Wegener Communications products. All Wegener Communications products are warranted against defective materials and  
workmanship for a period of one year after shipment to customer. Wegener Communications' obligation under this warranty is limited to repairing or, at Wegener  
Communications' option, replacing parts, subassemblies, or entire assemblies. Wegener Communications shall not be liable for any special, indirect, or consequential  
damages. This warranty does not cover parts or equipment, which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs  
for warranty repairs shall be prepaid by the customer. There are no other warranties, express or implied, except as stated herein.  
Technical Support  
In the event the unit fails to perform as described, contact Wegener Communications Customer Service at (770) 814-4057, FAX (678) 624-0294, or E-mail  
Corporate Office  
Wegener  
Service Department  
Wegener  
11350 Technology Circle  
Duluth, GA 30097  
359 Curie Drive  
Alpharetta, GA 30005  
800057-02 Rev. A  
Page 11 of 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
May 24, 2003  

Well Traveled Living Fire Pit 60364 User Manual
Westinghouse Flat Panel Television P2650HR User Manual
Whirlpool Air Conditioner ACQ152XK0 User Manual
Whirlpool Washer WTW6600SB3 User Manual
Williams Sound Microphone BROM 022A User Manual
Wilton Saw 7020 7040 User Manual
Wolf Spreader FS 0 0 WS 12 M User Manual
Yamaha CD Player CDX 596 User Manual
Zanussi Dishwasher 531310 User Manual
Zanussi Refrigerator 110022 User Manual