Item #2207
™
Elite 5000W
User’s Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
Introduction
General Instructions:
Thank you for purchasing this Wagan Pure Sine Wave DC to AC Power
Inverter. It delivers a true sine wave AC identical to that of commercial power.
Use this inverter to power AC appliances in your vehicle, at a campsite, or
at home as an emergency source of AC power. Pure Sine Wave AC means
that your sensitive electronics such as audio/video systems, computers, and
communications equipment will operate properly. This inverter is powered from
12 volts DC and it will continuously deliver 5,000 watts AC power at 120
Volts, 60 Hz.
• Keep the inverter away from any direct heat source or combustible
materials.
• Keep well ventilated–this device generates heat.
• Keep the inverter away from combustible gases.
• Do not continuously operate any equipment over 5,000 watts.
• This inverter is designed to operate from a 12 volt DC power source
only.
For your convenience, this inverter is supplied with a wireless remote control
and a set of cables. The installer must install a fuse and fuse holder for battery
protection. See Configuring Battery Bank section.
• Do not attempt to connect the inverter to any other power source,
including any AC power source.
• Incorrect battery polarity will damage the inverter and void the warranty.
• Keep this inverter in a dry environment.
This Wagan 5,000 watt Pure Sine Wave Inverter is an indispensable addition
to your compliment of mobile power equipment. With minimal care and
proper treatment it will provide years of reliable service.
• Do not open the inverter; there are no user serviceable parts inside.
Read and understand this manual before installing and operating this inverter.
Keep this manual for future use.
SAFETY WARNING!
The inverTer ouTpuT can be leThal. improper use of This inverTer may
resulT in properTy damage, personal injury, or loss of life.
About This Inverter.
This power inverter converts 12 volts, direct current (12V DC) to 120
volts alternating household current (120V AC). It easily powers TV/VCR
combinations, small microwave ovens, and refrigerators. It also operates at
high efficiency (up to 90%) that results in long running time and extended
battery life compared to other inverters with this level of power output.
Product Features
Front Panel
The Front Panel view shows the inverters ON/OFF Switch, Indicators, AC
Outlets, and Ground Terminal.
This inverter has the highest surge capability in its class. Superior surge
capability of 10,000 watts allows the inverter to start most difficult motorized
appliances. Advanced microprocessor-controlled circuits run cooler and are
more reliable than competing units.
• ON/OFF Switch
This switch controls AC output of the inverter.
• Operating LED (Green)
When this green LED is lit, the inverter is operating normally.
• The FAULT indicator turns RED as the inverter shuts down because of:
Excessive Temperature, Overload, Under Voltage, or Over voltage.
Immediately turn off all AC appliances if the FAULT LED is lit. Allow the
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
1
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
inverter to cool before continuing. Make sure that the ventilation vents
are not blocked.
• Ground Terminal
The Ground Terminal is located on the Front Panel. This terminal is for
attaching a 6 gauge insulated safety ground wire. This safety wire
protects personnel if there is an unlikely failure in either the cabling or
enclosure insulation. Do not directly connect this ground to any Negative
DC inverter terminal. This safety wire is to be connected to the vehicle
frame or earth ground or negative battery terminal as described in the
installation procedure.
If an inverter “shutdown” was preceded by a buzzing sound, there may
excessive load, in combination with a low voltage or cable problem.
Observe the Digital Display for low battery voltage. Normal operating
range is 10.5V to 15V DC.
• Digital Display
• Audible Alarm (internal to the inverter)
The Digital Display Shows the DC Voltage input that the inverter senses
at its terminals. Low battery, excessive load for the cables can cause
a low voltage reading and inverter shutdown. Low battery is also
indicated when the Audible Alarm sounds. An alternative display shows
the “Percent of Load that the inverter can handle”. If the inverter has
excessive load “OVL” will be displayed.
When the audible Alarm makes a buzzing sound, the inverter senses a
low battery condition. The user should reduce the AC load, charge the
battery, and check the DC cables for excessive losses.
• AC Outlets
Each of the four outlets is rated at 15 Amps 120V AC maximum (1800
Watts). Use High Output Terminals for appliance loads greater than 15
Amps or for distributed wiring.
• High Wattage Output Terminals
There are three insulated terminals on the front panel of the inverter.
These terminals are for connecting 120 Volt AC devices that require
more than 15 amps to operate or for connection to distribution wiring
with multiple branches and AC outlets. Any AC output wiring that is di-
rectly connected must comply with US National Electric Code (NEC) wir-
ing gauge recommendations. Facing the Front Panel, the terminals are:
Ground Terminal
Left
Middle
Right
Ground
Neutral
Hot (or Live)
Four 120V AC Outlets
Operating LED (Green)
Fault indicator (Red)
High Wattage Output Terminals
Digital Display
Neutral and Ground are bonded (connected) inside the inverter to
comply with the NEC requirement that any AC source must have a
Neutral to Ground connection.
ON/OFF Switch
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
Rear Panel
Remote On/OFF Switch
• Negative Terminal (black): Negative DC Input
This inverter is supplied with a 100-foot range battery-powered wireless remote
ON/OFF feature. To enable the Remote Switch, the front panel On/Off Switch
must be in the On position.
• Positive Terminal (red): Positive DC Input
• Cooling Fans: High-speed and temperature controlled
To turn On the inverter, momentarily press ON. To turn the inverter Off,
momentarily press “Lock”. If the wireless remote fails to control operation of
the inverter, you may be out of range for the radio signal—move closer to
the inverter. If the Remote Switch has a depleted battery, open the unit by
unscrewing the three small screws on the back side of the remote control and
replace the 12 volt model 23A alkaline battery with a new one.
Retractable
Antenna
Cooling Fans
Negative Terminal (black)
Positive Terminal (red)
ON switch
OFF switch
Sliding Cap
Retracted Antenna
Extended Antenna
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
Load Considerations
Determining Maximum Appliance Wattage
When an appliance with a motor starts, it requires a momentary surge of
power. This surge of power is the “starting load” or “peak load”. Once
started, the appliance requires less power to continue to operate. This is
known as the “continuous load”. It is important to know the starting loads and
the continuous loads of the appliances that are to be powered by the inverter.
Microwave oven specifications list cooking power (watts) and appliance
power. Appliance power is the AC load the inverter has to supply. Do not
exceed the 5,000 watt maximum AC load or the inverter will shut down.
Most other electrical tools, appliances, and audio/video equipment have
labels that list the unit’s power requirements in watts. If the tool or device is
rated in amps, multiply the amps by 120 (120V AC) to determine the watts. For
example, a power tool rated at 4 amps will draw 480 watts.
Appliance power is rated in watts. This information is usually stamped or
printed on most appliances and equipment. In some cases, a tool will be rated
in amperes. To convert from amps to watts, multiply:
Remember to consider the startup surge that motorized appliances will cause.
Do not exceed the 10,000 watt surge rating of this inverter this can cause
immediate overload shut down.
Amps x 120 (AC voltage) = Watts
This formula yields an approximation of the continuous wattage load of that
appliance.
At 5,000 watts continuous output, this inverter requires a DC power supply
(battery bank) that can continuously supply 417 amps at 12V DC for the
duration of the run time.
The startup load of an appliance is a major factor of whether this inverter can
power it.
Startup load is momentary. With many appliances, it is approximately twice
the continuous load, but some appliance startup loads can be as high as eight
times the continuous load.
Configuring the Battery Bank
To determine the minimum battery ampere-hour rating that you will need to
operate appliances from the inverter and any DC appliances powered by the
battery bank, follow these steps:
To determine if an appliance or tool will operate with this inverter, run a test.
This inverter will automatically shut down in the event of an output overload,
so there is no danger of damaging either the inverter or the equipment. When
lit, a red LED indicator signals a fault.
1. List the maximum continuous wattage that the inverter has to supply.
2. Estimate the number of hours the appliances will be in use between
battery recharges. This will vary depending on appliances. For example,
a typical home-use coffee maker draws 500 watts during its brew
time of 5 minutes. It maintains the temperature of the pot, requiring
100 watts. Typical use of a microwave oven is only for a few minutes.
Some longer operating time appliances are lamps, TVs, computers and
refrigerator/freezers.
Planning the Inverter System
Any large wattage inverter system requires planning before installation. There
are several steps to the planning process so the user must determine the
following:
• Maximum inverter wattage required.
Determine the total watt-hours of energy needed. This is done by multiplying
average power consumption in watts by hours of run time. For example: 500
watts for 10 hours = 5000 watt hours. To get an estimate of the maximum
current (in amps) that a battery bank must be capable of delivering to the
inverter, divide the load watts by ten. For example a 500 watt appliance load
will need 50 amps at 12 volts DC. Using the 500 watts (or 50 amps) for 10
• Operating time (run time) needed between battery recharges.
• Battery bank capacity in amp-hours.
• Charger requirement to charge batteries within a practical time.
• Distance between battery bank and inverter.
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
hours example as above, then 50 amps is needed for 10 hours. This provides
us with the basic amp-hours (AH) of battery that is required. Ten hours at 50
amps equals 500 amp-hours (AH). There are additional factors that determine
actual run time. These include:
Configuring the battery bank
Batteries that are used indoors or inside a vehicle or vessel, should be deep-
cycle, sealed lead acid batteries.
NOTE: It is important that for any inverter installation to battery protection
fuses. Battery fuses are added to the positive (+) battery cable as close as
possible to the battery bank’s positive terminal. The fuse amperage rating
must be sized to allow simultaneous operation of all the AC appliances
to be powered, plus 20 percent safety factor. Fuses are very important to
protect equipment, batteries and personnel. The fuses protect against battery
explosion if the cables that connect to the inverter accidentally short.
• AC appliance load and time in use (basic AH).
• Cable gauge and length (cable losses).
• Charge level of the batteries (between use, chargers have to be able to
fully charge the batteries).
• Temperature of the batteries (colder batteries provide fewer amps).
• Age and condition of the batteries (older batteries lose AH capacity).
• Compliance with turning off unnecessary AC loads.
Battery Bank Diagram
• Use of DC appliances and compliance with turning off unnecessary DC
loads.
This Battery Bank diagram shows the use of 6 Volt Golf Cart batteries wired to
deliver 12 Volts to the inverter. These batteries are flooded (venting) and vent
to outside air.
Derating the Battery Bank
Most lead-acid batteries have a rating expressed in amp-hours (AH). The most
common rating of AH is “at the 20 hour rate”.
Fuse(s)
6V
220AH
6V
220AH
6V
220AH
NOTE: Despite several internet explanations, there is no relationship between
cold cranking amps (CCA) and ampere-hours (AH).
Elite 5000W
For example, if a 20 AH battery is discharged at a 1 amp rate, is will take 20
hours to discharge that battery. The terms “charged” and “discharged” relate
to actual battery voltage. This means that the output voltage of a nominal
12 volt battery starts at 13.4 volts (fully charged) then drops to 10.5 volts
(discharged). If the load on the battery causes the battery to discharge faster
than the 20 hour rate, the capacity (AH) of the battery is measurably reduced
(derated). In heavy battery discharge applications, double the estimated Amp
Hour rating and configure batteries to support this capacity. If the batteries
are frequently charged by an alternator, the Amp Hour rating of the batteries
required may be reduced.
6V
6V
6V
220AH
220AH
220AH
Ground
WARNING—Exploding Batteries!!
exploding baTTeries can spray molTen lead, hoT sulfuric acid, and
oTher meTal and plasTic fragmenTs. baTTeries ThaT are charging or
under high discharge raTes produce explosive hydrogen gas inTo The
surrounding area. be safe–fuse The baTTery bank and make sure The
baTTeries are properly venTilaTed.
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
9
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
DC Cable Gauge
Connecting the Inverter
Minimize cable losses by using the thickest wire available and the shortest
practical length.
Loose connections will result in a severe voltage drop that can cause damage
to connectors, conductors, and insulation and can cause sparking. Reverse
polarity connection will blow the fuses in the inverter and can permanently
damage to the inverter. Damage caused by reverse polarity will void the
warranty.
Measure Round Trip (RT) cable distances in feet. Round Trip cable distance is
battery to inverter and back to battery. If the application is in a vehicle with
engine operating, use the supplied cables for round trip distances up to 5 feet.
Installation Procedure
Use a recommended ANL fuse and Fuse holder. Fuse at 600 Amps. ANL are
quick acting and sealed so they do not spark when they blow. Place fuse no
more than one foot from the Positive (+) terminal of the battery.
1. Mount the inverter in a secure location. If the inverter is to be mounted
on a wall, mount it horizontally. Make sure that the front and rear of the
inverter has free air flow.
The cables that are supplied with the inverter can be used for full wattage
applications that have the batteries under constant or frequent charge (mobile
applications). The supplied cable has an electrically equivalent 600 Amp ANL
fuse attached.
2. Make sure the cables are the proper gauge and have the fuse holder as
close to the battery bank’s Positive (+) terminal as possible.
3. Install the fuse in the Positive (+) cable.
If the inverter and the battery are positioned within two to three feet of
each other, a minimum of “00” gauge wire should be used to make DC
connections.
4. Make sure the ON/OFF switch located on the front panel of the inverter
is in the OFF (0) position.
5. Locate the ground lug terminal on the inverter. Connect an insulated 10
gauge copper wire to the terminal. The other end of the ground wire
is connected to a “proper” grounding point. Use the shortest practical
length of wire. Connect this wire to the chassis of your vehicle or to the
grounding system in your boat. In a city, the ground wire can connect
to a metal cold water pipe that goes underground. In remote locations,
the ground wire can be connected to an “earth ground”. This can be an
attachment to a foot long copper clad metal rod driven into the ground.
In the unlikely event of a short circuit, operating the inverter without
proper grounding can result in electrical shock. Do not directly connect
this ground wire to the Negative (−) DC Terminal of the inverter. As an
alternative grounding connection, use the Negative (−) terminal of the
battery.
Notes:
• Include distances between the fuse block terminals in measuring total
cable length.
• Total Round Trip (RT) means total Pos and Neg cable lengths to battery.
Cable Lengths and Gauges for full 5000 Watt Output
Total RT Length in Feet,
Inches and Centimeters.
AWG (American Wire
Gauge) and Thousand
Circular Millimeters (Kcml)
Diameter of copper
conductor
2 Ft (24 in) (61 cm)
4 Ft (48 in) (122 cm)
6 Ft (48 in) (182 cm)
10 Ft (48 in) (304 cm)
12 Ft (48 in) (365 cm)
00
0.375 in (1 cm)
0.52 in (1.3 cm)
0.68 in (1.7 cm)
0.81 in (2.1 cm)
0.96 in (2.4 cm)
0000
NOTE: Crimp-on ring terminals are required on all cable ends. The cable
ends need to be stripped of insulation for 1 inch before crimping on ring
terminals. Select a crimp terminal size to fit the gauge cable and inverter
and battery terminal connectors. After crimping make sure that the cable
connectors are secure on the cables so there are no loose connections.
359 Kcml
500 Kcml
700 Kmcl
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
6. Connect the Negative (−) cable end to the inverter terminal and battery
Negative Terminal. Make sure you have good, secure connections.
17. Observe the LED indicators and the Digital Display for Normal
operation.
7. Recheck and make sure the DC cable fuse is installed in the fuse holder.
Note: If an extension cord is used from the inverter to the appliance, limit the
extension cord length to 100 feet or less. Make sure that the cord is safety
approved and AWG 14 or greater to carry the appliance load. Remember that
extension cords are for temporary use.
CAUTION: Making an initial connection between the positive cable end
and the inverter’s positive terminal may cause a spark. This is a normal
and is a result of capacitors in the inverter starting to charge. Because
of the possibility of sparking, it is extremely important that both the
inverter and the battery bank be positioned away from any source of
flammable fumes or gases. Failure to heed this warning can result in fire
or explosion. Do not make the positive terminal connection immediately
after the batteries have been charging. Allow time for the battery gasses
to vent to outside air.
Charging the Battery Bank
It is not the purpose of this inverter user’s guide to provide detailed information
regarding battery charging systems. However, the user should try to augment
any stationary inverter charging system with either wind power or solar
power. These can continue to operate during power outages and they also
reduce recharge time. For mobile or marine charging systems, a higher rated
alternator may be necessary to charge a battery bank.
8. Attach the positive cable to the Positive (+) DC connector on the battery
and then the inverter. Make sure the connections are tight and secure.
9. Turn ON the inverter from the Front Panel On/OFF Switch
Regular Loss of Commercial Power
If the inverter system is used during commercial power outages that occur
daily, configure the charger system to replace energy during the time that
commercial power is available.
10. Make certain that the green Operating LED is lit and the FAULT LED
indicator is not lit.
11. Turn OFF (0) the inverter. The Fault LED may briefly “flash”. This is
normal. The audible alarm may also sound a short “chirp”. This is
also normal.
Replacement of battery energy always requires more than was taken from
the battery (typically 30 percent more). Follow battery manufacturer’s
recommendations for maximum charging current.
12. When you have confirmed that the appliance to be operated is turned
off, plug the appliance into one of the two AC outlets on the front panel
of the inverter.
Warning:
13. Turn the inverter on.
There is danger of explosion. do noT connecT or disconnecT
charger cables direcTly afTer baTTery discharge or recharge–make
sure ThaT The baTTery bank area is Well venTed before aTTaching or
removing cables.
14. Check operation of the Remote Switch – Press “Lock” to turn Off
the inverter.
15. Press the Unlock button to turn On the inverter.
16. Turn the appliance on. The appliance should begin working.
If the flooded lead acid batteries are used, be sure that periodic checks of
battery electrolyte levels are accomplished. Follow battery manufacturer’s
instructions in keeping the electrolytes at the proper level. Be sure to use pure
distilled water when replacing evaporated electrolyte liquid.
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
13
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
User’s Manual—Read before using this equipment
Operating Issues
Troubleshooting
(Television and Audio Equipment Suggestions.)
PROBLEM: Low or No Output Voltage – Fault LED Lit
Although all inverters are shielded and filtered to minimize signal interference,
some interference with your television picture may be unavoidable, especially
with weak signals. However, here are some suggestions that may improve
reception.
Reason
Solution
Poor contact with battery or inverter
terminals.
Clean terminals thoroughly. Reinstall
and tighten.
• Make sure that the television antenna produces a clear signal under
normal operating conditions (i.e. at home plugged into a standard
110/120V AC wall outlet). Also ensure that the antenna cable is properly
shielded and of good quality.
PROBLEM: Inverter is Shut Down – Fault LED Lit
Reason
Solution
Battery voltage below 10 Volts
Charge or replace battery.
• Sometimes vehicle alternators produce some electrical noise. There are
filters available to mount on the alternator to reduce noise.
Inverter is too hot (thermal shut down • Allow inverter to cool.
mode).
• Check for adequate ventilation.
• Change the positions of the inverter, antenna cables and television
power cord.
• Reduce the load on the inverter to
rated continuous power output.
• Isolate the television, its power cord and antenna cables from the 12
volt power source by running an extension cord from the inverter to the
television set.
Unit may be defective.
See warranty and call customer
service.
PROBLEM: Inverter Shut Down – Fault LED Lit – OVL Display
Reason Solution
Equipment being operated draws too Use a higher capacity inverter or do
much power. not use this equipment.
PROBLEM: Continuous Buzzing Sound – Display Shows Low Voltage
Reason
Solution
Input voltage below 10.5 Volts
Poor or weak battery condition.
Poor or loose cable connection
Keep input voltage above 10.5 Volts
Recharge or replace battery.
Inspect terminals and tighten all con-
nections.
Inadequate power being delivered
to the inverter or excessive voltage
drop.
• Use heavier gauge DC cable.
• Keep cable length as short as pos-
sible.
©2012 Wagan Corporation
All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
www.wagan.com
15
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Elite™ 5000W—Pure Sine Inverter by Wagan Tech
WAGAN Corp. Limited Warranty
The WAGAN Corp warranty is limited to products sold only in the United States.
Disposal/Recycling of Inverter
Electronic products are known to contain materials that are toxic if improperly
disposed. Contact local authorities for disposal and recycling information.
All Wagan Tech products must be registered within (30) days of purchase to
activate its warranty. To register your product, please visit http://tinyurl.com/
waganwarranty. Be sure to keep the original receipt as it will be required when
returning a product under the warranty.
Warranty Duration: This product is warranted to the original purchaser for a
period of two (2) years from the original purchase date, to be free of defects
in material and workmanship. WAGAN Corporation disclaims any liability for
consequential damages. In no event will WAGAN Corporation be responsible
for any amount of damages beyond the amount paid for the product at retail.
Specifications*
• Output Waveform: True Sine Waveform
• Input: 11V–15V DC
• Output: 120V AC
Warranty Performance: During the above two (2) year warranty period, a
product with a defect will be replaced with a comparable model when the
product is returned to WAGAN Corporation with an original store receipt. The
replacement product will be in warranty for the balance of the original two (2)
year warranty period.
• TrueRated™ Power: 5,000 watts
• Peak Surge: 10,000 watts
Approximately 90
• Maximum Efficiency:
• Frequency: 60 Hz
%
To return a defective item, please contact WAGAN Corporation at (800) 231-
5806 to obtain a Returned Merchandise Authorization number (RMA#), and
return instructions. Each item returned will require a separate RMA#. After you
have received the RMA# and the return instructions from WAGAN Corporation,
please follow the instructions and send the item with PREPAID SHIPPING, along
with all of the required documentation, a complete explanation of the problem,
your name, address and daytime phone number. WAGAN Corporation will, at
its option, replace or repair the defective part.
• Remote Switch range: 100 Ft
• Remote Switch Battery type: 12V
<
• Total Harmonic Distortion (THD): 5%
<
• No load current draw: 3.0A
• Switch OFF: <0.2mA DC
• Battery low alarm: 10.7V 0.3V DC
A Returned Merchandise Authorization number (RMA#) is REQUIRED when
sending in any defective item. WAGAN Corporation is not responsible for any
item(s) returned without an official Returned Merchandise Authorization number.
The item(s) must be returned with prepaid shipping. WAGAN Corporation is not
responsible for any shipping charges incurred in returning the item(s) back to
the company for repair or replacement. This warranty is void if the product has
been damaged by accident, in shipment, unreasonable use, misuse, neglect,
improper service, commercial use, repairs by unauthorized personnel or other
causes not arising out of defects in materials or workmanship. This warranty
does not extend to any units which have been used in violation of written
instructions furnished.
• Battery low shutdown: 10.2V 0.3V DC
0.5V
• Over voltage shutdown: 15.5V
• Cooling fan controlled by temperature
• AC output sockets: Four 120V AC outlets
• Power switch DC input ON/OFF control
• Digital status display
• Dimensions: 25.0 x 9.0 x 5.5 inches (63.5 x 22.9 x 14.0 cm)
• Net Weight: 33.7 lbs (15.3 kg)
Warranty Disclaimers: This warranty is in lieu of all warranties expressed or
implied and no representative or person is authorized to assume any other
liability in connection with the sale of our products. There shall be no claims
for defects or failure of performance or product failure under any theory of
tort, contract or commercial law including, but not limited to negligence, gross
negligence, strict liability, breach of warranty and breach of contract.
*All specifications are typical at nominal line, half load, and 77ºF (25ºC) unless otherwise
noted Specifications are subject to change without notice.
©2008 WAGAN Corp. REV2012
www.wagan.com
17
Download from Www.Somanuals.com. All Manuals Search And Download.
|