Vulcan Hart Fryer VGF 18 User Manual

INSTALLATION&  
OPERATIONMANUAL  
VGF-18 HEAVY DUTY  
GAS FRYERS  
MODEL  
VGF-18  
ML-136401  
MODEL VGF-18  
For additional information on Vulcan-Hart or to locate an authorized parts  
VULCAN-HART  
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC  
P.O. BOX 696, LOUISVILLE, KY 40201-0696  
TEL. (502) 778-2791  
WWW.VULCANHART.COM  
FORM 35638 (05-05)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION, OPERATION AND CARE OF  
MODELS VGF-18 HEAVY DUTY GAS FRYERS  
PLEASE KEEP THIS MANUAL FOR FUTURE USE  
GENERAL  
Your Vulcan-Hart Gas Fryer is produced with quality workmanship and material. Proper installation,  
usage and maintenance will result in many years of satisfactory performance.  
It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions  
provided.  
OPTIONAL FIELD INSTALLABLE ACCESSORIES  
Tank Brush  
Tank Cover  
(4) Casters  
Grease Strip  
4' (1.21 m) Quick Disconnect Hose  
(2) Twin Fry Baskets  
Single Basket  
INSTALLATION  
Before installing the fryer, verify that the type of gas (natural or propane) agrees with the  
specifications on the fryer data plate which is located on the inside of the door. Also be sure the  
fryer is built for the installation elevation.  
The fryer must be restrained with adequate ties to prevent tipping when installed in order to avoid  
the splashing of hot liquid.  
UNPACKING  
This fryer was carefully inspected before leaving the factory. The transportation company assumes  
full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking  
the fryer, check for possible shipping damage. If the fryer is found to be damaged, save the  
packaging material and contact the carrier within 15 days of delivery.  
Do not use the door or its handle to lift or move the fryer.  
ITEMS PACKAGED WITH FRYER  
Crumb Screen  
Drain Pipe  
(4) Legs  
Basket Hanger  
(2) Twin Fry Baskets  
Manual  
Warranty and Service Pack  
— 3 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LOCATION  
CAUTION: The equipment area must be kept free and clear of combustible substances.  
Installation clearances:  
COMBUSTIBLE  
CONSTRUCTION  
6" (152)  
NONCOMBUSTIBLE  
CONSTRUCTION  
Back:  
Right Side:  
Left Side:  
0"  
0"  
0"  
6" (152)  
6" (152)  
The installation location must allow adequate clearances for servicing and proper operation. A  
minimum front clearance of 35" (889 mm) is required.  
There must be at least 16" (406.4 mm) clearance between the fryer and any open top flame units.  
Adequate clearances for servicing and proper operation must be allowed.  
Install the fryer in an area with sufficient air supply for combustion of the gas at the fryer burners.  
Provide adequate clearance for air openings into the combustion chamber. Do not obstruct the flow  
of combustion and ventilation air.  
Do not permit fans to blow directly at the fryer. Wherever possible, avoid open windows next to the  
sides or back of the fryer. Avoid wall-type fans which create air cross currents within the room.  
INSTALLATION CODES AND STANDARDS  
Your Vulcan Fryer must be installed in accordance with:  
In the United States of America:  
1. State and local codes.  
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The  
American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.  
3. ANSI-NFPA Standard #96, Vapor Removal from Cooking Equipment, (latest edition), available  
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
In Canada:  
1. Local codes.  
2. CSA B149.1 Natural Gas and Propane Installation Code.  
3. CSA C22.1 Canadian Electrical Code.  
The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100,  
Mississauga, Ontario, Canada L4W 5N6.  
ASSEMBLY  
Legs  
Position fryer in an open space near the final installation area. Tilt fryer back, being careful to avoid  
scratching the finish. Thread front legs clockwise into mounting plates provided on the bottom of  
the fryer until seated. Tilt to front and thread back legs similarly. Carefully raise fryer to its normal  
position and place it in the installing location.  
— 4 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fryers Mounted on Optional Casters  
Fryers mounted on casters must use a flexible  
connector (NOT SUPPLIED BY VULCAN) that  
complies with the Standard for Connectors of  
Movable Gas Appliances, ANSI-Z21.69 • CSA6.16  
and a quick-disconnect device that complies with  
the Standard for Quick-Disconnect Devices for Use  
With Gas Fuel, ANSI-Z21 • CSA 6.9.  
In addition, adequate means must be provided to  
limit the movement of the appliance without  
depending on the connector and the quick-  
disconnect device or its associated piping to limit  
the appliance movement. Attach the restraining  
device to the rear of the fryer as shown in Fig. 1.  
Fig. 1  
If it is necessary to disconnect the restraint, turn off the gas supply before disconnection. Reconnect  
the restraint before turning the gas supply on and returning the fryer to its installation position.  
Instructions for installing casters to the fryer are included with the casters.  
LEVELING THE FRYER  
Stand Alone Installations  
Once gas connections have been made, place a spirit level on top of the fryer. Adjust the legs to  
ensure that the fryer is level front-to-back and side-to-side in the final installed position.  
Battery Installations  
When the fryer is part of a battery lineup, line the fryer up front-to-back and side-to-side with  
adjacent battery equipment. Equipment front tops and manifold pipes must be aligned with adjacent  
equipment. Once the fryer is in its exact location in the battery lineup, place a spirit level on top of  
the fryer. Adjust the legs to ensure that the fryer is level front-to-back and side-to-side in the final  
installed position.  
— 5 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAS CONNECTIONS  
CAUTION: All gas supply connections and any pipe joint compound used must be  
resistant to the action of propane gases.  
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR  
LEAKS. USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.  
Rear Gas Connection for Stand Alone Installations  
The gas inlet is located at the lower left rear.  
Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.  
The gas supply line must be at least the equivalent of 1/2" (12.7 mm) iron pipe. If using the optional  
quick-disconnect flex hose, 3/4" (19 mm) iron pipe must be used unless 3/4" (19 mm) to 1/2" (12.7 mm)  
reducing fittings are used. Make sure the pipes are clean and free of obstructions, dirt, and piping  
compound.  
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove  
air.  
Front Gas Connection for Battery Installations  
Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer and battery of  
equipment.  
The gas manifold of a battery lineup of which the fryer is a part, must be installed using a regulator  
design-certified by a nationally recognized testing lab to the applicable ANSI standard (regulators  
available from Vulcan-Hart). The pressure regulator must have a maximum regulation capacity to  
handle the total connected load and must have an adjustment range for manifold pressure marked  
on the equipment rating plate(s). If the manifold pressure of the connected equipment is not the  
same, a separate regulator must be supplied for all devices operating under different manifold  
pressure ratings.  
CONNECTION OF MANIFOLDS IN BATTERY  
1. If the fryer requires alignment to match the battery lineup, loosen 2 bolts on each U bracket  
securing the 11/4" (31.8 mm) manifold pipe to the fryer.  
2. Shift the 11/4" (31.8 mm) manifold pipe left or right, in or out, until alignment with the equipment  
battery manifold pipe is achieved. While holding the fryer manifold in place, tighten the holding  
screws on the U bracket back in place.  
3. Apply pipe sealer resistant to the action of propane gases around the threaded edge(s) of the  
fryers 11/4" (31.8 mm) manifold pipe.  
4. Engage the union nut on the fryer manifold pipe with the male fitting on the batteried unit  
adjacent to the fryer. Draw up the union hand tight. Continue connecting the manifolds, following  
these steps 1 - 4, until all units in the battery lineup are installed.  
5. Using channel locks, tighten all connection points along the manifold of the entire equipment  
battery.  
6. Install manifold end cap if applicable.  
7. Check all connection points along the manifold for gas leaks.  
— 6 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TESTING THE GAS SUPPLY SYSTEM  
When test pressures exceed 1/2 psig (3.45 kPa), the fryer and its individual shutoff valve must be  
disconnected from the gas supply piping system.  
When test pressures are 1/2 psig (3.45 kPa) or less, the fryer must be isolated from the gas supply  
system by closing its individual manual shutoff valve.  
FLUE CONNECTIONS  
DO NOT obstruct the flow of flue gases from the flue located at the rear of the fryer. It is  
recommended that the flue gases be ventilated to the outside of the building through a ventilation  
system installed by qualified personnel.  
Adequate ventilation must be provided and must comply with NFPA Standard #96 (latest edition),  
and with local codes.  
Never make flue connections directly to the fryer.  
The fryer must be located under a hood which has an adequate connection to an exhaust duct. The  
hood must extend 6" (152.4 mm) beyond fryer sides.  
Clearance above fryer should be adequate for products of combustion to be removed efficiently. An  
18" (457 mm) minimum clearance should be maintained between the flue vent and the filters of the  
hood venting system.  
Information on the construction and installation of ventilating hoods may be obtained from the  
standard for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available  
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
Adequate air should be provided in the kitchen to replace air taken out by the ventilating system.  
This will prevent fryer function from being affected by a reduced atmospheric pressure.  
— 7 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING,  
CLEANING AND SERVICING THE FRYER.  
WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER  
WITHOUT DRAINING ALL OIL FROM THE TANK.  
Tank warranty may be voided by improper operation. Turn gas valve off when draining or filling.  
FILL FRY TANK WITH LIQUID SHORTENING  
CAUTION: Before turning the burners on, the fry tank  
must be filled with liquid shortening. If this is not  
done, the tank walls can be damaged. Warpage can  
cause leaks.  
Use only liquid shortening. Fill fry tank to the "oil level" line on  
the back wall (Fig. 2).  
DO NOT melt solid shortening in the fry tank. The fry tank  
will be damaged and the shortening will be scorched.  
Do not overfill tank.  
Keep shortening between the MIN and MAX lines in fry tank.  
Add fresh shortening as needed.  
Fig. 2  
OVER TEMPERATURE DEVICE  
If the shortening becomes overheated, a high temperature shutoff device will turn the gas valve off  
and extinguish the pilot. DO NOT relight the pilot until the shortening temperature is below 300°F  
(149°C). If this situation persists, contact your local Vulcan-Hart authorized service office.  
LIGHTING THE PILOT  
1. Turn thermostat OFF. Thermostat is located behind the  
door (Fig. 3).  
2. Turn gas control valve knob to OFF/PILOT (Fig. 4). Wait  
5 minutes for unburned gas to vent.  
3. Push gas control knob in (Fig. 4).  
4. While still holding knob in, light the pilot with a lit taper.  
Continue to depress knob for 30 seconds, then release the  
knob. Pilot should remain lit when knob is released.  
If pilot does not remain lit, repeat Steps 2, 3, and 4.  
5. Turn gas control knob to ON (Fig. 5).  
Fig. 3  
6. If gas supply is interrupted, repeat Steps 1-5.  
— 8 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TURNING THE FRYER ON  
To turn the fryer on, set the thermostat knob to the desired  
temperature. After the set temperature has been reached, the  
gas control shuts off gas flow to the burners. The pilot remains  
lit. The burners will cycle on and off, maintaining the set  
temperature.  
TURNING THE FRYER OFF  
Fig. 4  
1. Turn the thermostat OFF.  
2. Turn the gas control valve knob to PILOT. In this position  
the pilot will remain lit.  
3. To shut off all gas to the system, including the pilot, turn the  
gas control valve knob to OFF.  
EXTENDED SHUTDOWN  
1. Turn the manual gas shutoff valve OFF.  
2. Turn the thermostat knob OFF.  
Fig. 5  
3. Turn the gas control valve knob to OFF.  
FRYING FOODS  
Heat shortening to set temperature.  
Pieces of product to be fried should be about the same size to ensure the same doneness.  
Drain or wipe dry raw or wet foods to minimize spatter when lowering into the hot oil.  
Do not overfill baskets.  
Carefully lower baskets into oil.  
When frying doughnuts and fritters, turn product only once during frying.  
When cooking French fries or onion rings, shake basket several times in a way that does not  
spatter the shortening.  
Batter-covered foods should be dropped carefully, one by one, into shortening or basket. If you  
use the basket, first dip basket into the shortening to reduce batter build-up on basket surfaces.  
When frying is completed, remove baskets or product. Hang baskets on rear basket hangers.  
Remove food and season it. Do not salt food over the shortening because salt could cause a  
chemical change in the oil.  
— 9 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHORTENING LIFE  
Shortening life may be extended by following these guidelines:  
Do not salt foods over the fryer.  
Use good quality shortening.  
Filter shortening at least daily.  
Replace shortening if it becomes poorly flavored.  
Keep equipment and surroundings clean.  
Set thermostats correctly.  
Remove excess moisture and particles from food products before placing in fryer.  
Add approximately 15% new oil daily. Keep level of shortening between the MIN and MAX level  
on the fryer tank back wall. Add fresh shortening as needed.  
DAILY FILTERING  
Turn gas valve OFF when draining or filling.  
The shortening should always be filtered while liquefied. A cold fryer will not drain properly because  
the shortening under the cold zone tube area will remain hard, even if the heat is on for a few  
minutes. If necessary, the clean-out rod may be used to carefully stir up hard fat to an area above  
the cold zone where it will melt. After the cold zone is liquefied, turn the fryer thermostat and gas  
valve OFF.  
Shortening life will be extended by filtering at least once a day or more often if conditions warrant.  
A commercial power filter (available from other manufacturers) may be used. Follow the  
manufacturer's operating instructions for draining, straining, and replacing shortening in the fry  
tank.  
Another way to filter is to drain the shortening from the drain pipe through a filter bag, or cover the  
receiving container with cheesecloth or other filtering material.  
Filtering Procedure  
1. Turn the fryer OFF.  
2. Slowly remove the baskets, especially if shortening is hot, to prevent splashing.  
3. Open the fryer door and attach the drain pipe to the drain valve.  
4. Select a container of sufficient capacity and place it below the drain pipe.  
5. If you are using a filter bag, tie it securely to the drain pipe. If other filter medium is used, place  
it in the container.  
6. Open the drain valve carefully so the oil stream is directed through the filter.  
7. With a small amount of warm shortening, flush out scraps and sediment in the fry tank. Drain  
the tank thoroughly and wipe clean.  
8. If it is necessary to clean the tank more thoroughly follow the procedure shown in CLEANING  
— WEEKLY OR AS REQUIRED.  
9. Close the drain valve.  
10. Pour the strained shortening back into the vat.  
11. Add shortening to the "oil level" line.  
— 10 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING  
Daily  
Clean your fryer regularly. Keeping the fryer clean and free of accumulated grease will prevent  
stubborn stains from forming. Wash all exterior surfaces at least once daily. Use a cloth with warm  
water and a mild soap or detergent. Follow with a clear rinse, then dry.  
If regular cleaning is neglected, grease will be burned on and discolorations may form. These may  
be removed by washing with any detergent or soap and water. A self-soaping scouring pad may  
be used for particularly stubborn discolorations.  
Always rub with the "GRAIN" in a horizontal direction. Do not use stainless steel wool pads on  
stainless steel finishes. Pieces of the steel wool will adhere to the stainless steel surface and cause  
rusting.  
Weekly or as Required  
1. Once the shortening has been drained, flush out scraps and sediment with a small amount of  
warm shortening. Allow the tank to drain thoroughly.  
2. Close the drain valve and fill the tank with a non-corrosive, grease-dissolving commercial  
cleaner, following the manufacturer's instructions.  
3. Set the thermostat at a temperature recommended by the manufacturer of the commercial  
cleaner and boil the solution for 15 to 20 minutes. Monitor boiling to prevent overflow.  
4. Drain the cleaning solution from the tank.  
5. Close the drain valve and refill the tank with water. Add 1 cup (237 ml) of vinegar to neutralize  
alkaline left by the cleaner. Bring the solution to a boil and allow it to stand for a few minutes.  
6. Drain the tank and rinse thoroughly with clear, hot water. All traces of cleaner must be removed.  
Dry the tank thoroughly.  
7. Close the drain valve.  
8. Add shortening between the MIN and MAX level lines.  
Cleaning Stainless Steel  
Stainless steel may be cleaned with ordinary soap or detergent and water. To prevent water spots  
and streaks, rinse equipment thoroughly with warm water and wipe dry with a soft clean cloth. The  
addition of a rinsing agent will also help prevent spotting.  
Fingerprints  
Fingerprints are sometimes a problem on highly polished surfaces of stainless steel. They can be  
minimized by applying a cleaner that will leave a thin, oily or waxy film. Wipe cleaner on and remove  
excess with a soft dry cloth.  
— 11 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING,  
CLEANING AND SERVICING THE FRYER.  
WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER  
WITHOUT DRAINING ALL OIL FROM THE TANK.  
FLUE  
Annually check the flue when it is cool to be sure it is free of obstructions.  
SERVICE AND PARTS INFORMATION  
To obtain service and parts information, contact the Vulcan-Hart Service Agency in your area (refer to  
When calling for service, the following information must be available: Model number, serial number,  
manufacture date (MD), gas type and voltage.  
FORM 35638 (05-05)  
PRINTED IN U.S.A.  
— 12 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson Universal Remote RU254 User Manual
Thermador Microwave Oven MET27E User Manual
Thule Network Hardware TK12 User Manual
TP Link Network Router TD W8970 TD W8970B User Manual
Tripp Lite Network Cables P781 016 User Manual
Troy Bilt Tiller 682J E686N E682L User Manual
TROY Group Printer TROY IRD 3005 User Manual
U Line Ice Maker Refrigerator Ice Maker Combos User Manual
Vizio Blu ray Player VBR100 User Manual
Wachsmuth Krogmann Electric Heater C 3196 User Manual