Vulcan Hart Fryer 1GR35M ML 136407 User Manual

INSTALLATION &  
OPERATIONAL MANUAL  
GRM SERIES GAS FRYERS  
MODELS:  
1GR35M  
1GR45M  
1GR65M  
1GR85M  
ML-136407  
ML-136408  
ML-136409  
ML-136410  
ML-136785  
ML-136786  
ML-136787  
ML-136417  
ML-136418  
ML-136419  
ML-136420  
ML-136421  
ML-136422  
ML-136423  
1GR45MF  
1GR65MF  
1GR85MF  
2GR45MF  
2GR65MF  
2GR85MF  
3GR45MF  
3GR65MF  
3GR85MF  
4GR45MF  
1GR45M Shown  
For additional information on Vulcan-Hart or to locate an authorized parts  
and service provider in your area, visit our website at www.vulcanequipment.com  
VULCAN-HART  
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC  
WWW.VULCANEQUIPMENT.COM  
3600 NORTH POINT BLVD.  
BALTIMORE, MD 21222  
F-31233 REV. K (February 2011)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
TABLE OF CONTENTS  
IMPORTANT FOR YOUR SAFETY……………………………………….  
INTRODUCTION……………………………………………………………  
GENERAL……………………………………………………………  
2
4
4
ORDERING PARTS………………………………………………… 4  
FRYER CAPACITIES………………………………………………. 4  
UNPACKING………………………………………………………… 4  
INSTALLATION…………………………………………………………….  
Clearances…………………………………………………....5  
Location ………………..……………………………….….  
CODES AND STANDARDS……………………………………….. 6  
ASSEMBLY …………..……………………………………………  
5
6
6
FLUE CONNECTION………………………………………………. 7  
GAS CONNECTION…………………………………………………. 7  
Quick-Disconnect for Units on Casters…………………… 7  
GAS PRESSURE......................................................................... 8  
TEST GAS SUPPLY………………………………………………… 8  
FRYERS WITH CASTERS………………………………………… 8  
LEVELING THE FRYER…………………………………………… 9  
OPERATION…………………………………………………………………  
9
OVER-TEMPERATURE SHUTDOWN……………………………. 9  
BEFORE FIRST USE………………………………………………... 10  
Cleaning……………………………………………………....10  
FILLING TANK WITH SHORTENING…………………………… 10  
LIGHTING THE PILOT  
TURNING ON THE FRYER …….  
TURNING OFF THE FRYER  
11  
12  
12  
EXTENDED SHUTDOWN………………………………………….. 12  
BASIC FRYING INSTRUCTIONS………………………………….. 12  
Fry Basket Guidelines……………………………………….12  
EXTENDED SHORTENING LIFE………………………………… 13  
DRAINING THE TANK……………………………………………. 13  
DAILY FILTERING-ALL MODELS……………………………….  
14  
CLEANING…………………………………………………………. 14  
Daily…………………………………………………………. 14  
BOIL OUT PROCEDURE………………………………………………....  
15  
KLEENSCREEN PLUS® INSTALLATION & OPERATION MANUAL.... 16  
GAS KLEENSCREEN PLUS® MODELS………………………….. 16  
FILTERING INSTRUCTIONS FOR KLEENSCREEN PLUS® FRYERS… 17  
GENERAL …………………………………………………………… 17  
ASSEMBLY…………………………………………………………….17  
OPERATION…………………………………………………………………… 20  
FILTERING PROCEDURE……………………………....  
20  
FILTERING TIP……………………………………………………. 21  
REMOVING EXCESS DEBRIS FROM THE FILTER………….. 21  
FLUSH AND DISCARD…………………………………………….. 22  
BOIL OUT PROCEDURE………………………………………  
THERMAL OVERLOAD PROTECTION RESET BUTTON…… 23  
MAINTENANCE………………………………………………………….. 23  
FLUE VENT INSPECTION……………………………………….. 23  
22  
Service in the US and Canada…………………………………...  
In Australia………………………………………………………….  
TROUBLESHOOTING……………………………………………………..  
23  
23  
23  
Troubleshooting Chart………………………………………………. 24  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-3-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
INTRODUCTION  
GENERAL  
Vulcan Fryers are produced with quality workmanship and material. Proper installation,  
usage and maintenance will result in years of satisfactory performance.  
Before installing the fryer, thoroughly read this manual and carefully follow all instruction.  
This manual is applicable to model listed on the cover page. Procedures in this manual  
will apply to all models unless specified. Pictures and illustrations can be of any model  
unless the picture or illustration needs to be model specific.  
ORDERING PARTS  
Customers may order parts directly from their local authorized service center. If not  
known, call Vulcan Customer Service at 800-814-7028.  
To speed up your order, provide the model number, serial number, gas type, part needed,  
item part number (if known) and quantity needed.  
FRYER CAPACITY  
MODEL -  
GMO  
# of Heat Tubes  
Each Fry Tank  
BTU / Hour  
Each Fry Tank  
Width Inch (cm)  
Total System  
Shortening lbs. (kg)  
Each Fry Tank  
1GR35M  
3
4
5
5
4
4
4
5
5
5
5
90,000  
120,000  
150,000  
150,000  
120,000  
120,000  
120,000  
150,000  
150,000  
150,000  
150,000  
15.5" (39)  
15.5" (39)  
21.0" (53)  
21.0" (53)  
31.0" (79)  
46.5" (118)  
62.0" (158)  
42.0" (107)  
63.0" (160)  
42.0" (107)  
63.0" (160)  
35-40 (16-18)  
45-50 (21-23)  
65-70 (29-32)  
85-90 (39-41)  
45-50 (21-23)  
45-50 (21-23)  
45-50 (21-23)  
65-70 (29-32)  
65-70 (29-32)  
85-90 (39-41)  
85-90 (39-41)  
1GR45M (F)  
1GR65M (F)  
1GR85M (F)  
2GR45MF  
3GR45MF  
4GR45MF  
2GR65MF  
3GR65MF  
2GR85MF  
3GR85MF  
UNPACKING  
This fryer was carefully inspected before leaving the factory. Upon acceptance of the  
shipment, the transportation company assumes full responsibility for safe delivery.  
Immediately after unpacking the fryer, check for possible shipping damage. If the fryer is  
damaged, save the packaging material and contact the carrier within 15 days of delivery.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-4-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Check that the following have been included:  
Crumb Rack  
Basket Hanger  
Twin Fry Baskets (2)  
Tank Brush  
Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer  
Batteries with the KleenScreen PLUS® Filtration System have casters installed  
from the factory.  
Drain Pipe Extension for freestanding fryers only.  
Cleanout Rod for freestanding fryers only.  
Crumb Scoop for freestanding fryers only.  
Manual and Warranty  
Fryer Batteries with the KleenScreen PLUS® Filtration System  
Filter Pan  
Suction Tube  
Screen Assembly  
Complimentary Pack of Micro-Filtration Envelopes  
6’ high temperature discard hose  
Do not use the door or its handle to lift the fryer.  
INSTALLATION  
Before installing the fryer, verify that the type of gas (natural or propane) agrees with the  
specifications on the fryer data plate, which is located on the inside of the door panel.  
Make sure the fryer is configured for the proper elevation.  
Record your fryer model, device, and serial numbers for future reference in the space  
provided below. This information can be found on the fryer data plate.  
Fryer Model No: ___________________________  
Device:___________________________________  
Serial No: ________________________________  
Clearances  
Minimum clearance from combustible construction:  
6” (15 cm) from the sides of the fryer  
6” (15 cm) from the back of the fryer  
The fryer may be installed on combustible floors  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Minimum clearance from noncombustible construction:  
0” from the sides of the fryer  
0” from the back of the fryer  
Between the fryer and any open-top flame units: 16” (41 cm)  
Allow space for servicing and operation.  
Location  
Install fryer in an area with sufficient air supply for gas combustion at fryer burners.  
Do not obstruct the flow of combustion and ventilation air.  
Provide adequate clearance for air openings into the combustion chamber.  
Do not permit fans to blow directly onto fryer.  
Avoid wall-type fans, which create cross-currents within a room. Avoid open  
windows next to sides or back.  
CODES AND STANDARDS  
The fryer must be installed in accordance with:  
In the United States:  
State and local codes, or in the absence of local codes, with:  
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may  
be obtained from The American Gas Association Accredited Standards  
Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the  
Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-  
7471.  
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition,  
available from the National Fire Protection Association, Batterymarch Park,  
Quincy, MA.  
In the commonwealth of Massachusetts all gas appliances vented through a  
ventilation hood or exhaust system with a damper or with a power means of  
exhaust shall comply with 248 CMR.  
In Canada:  
Local codes  
CAN/CSA-B149.1 Natural Gas and Propane Code Installation (latest edition),  
available from the Canadian Gas Association 350 Sparks Street, Ottawa,  
Ontario Canada K1R 7S8.  
CSA C22.1 Canadian Electric Code L4W 5N6.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-6-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
ASSEMBLY  
The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means  
of restraint may be the manner of installation, such as connection to a battery of  
appliances, installing the fryer in an alcove, or by separate means such as adequate ties.  
FLUE CONNECTION  
Make the flue connection as follows:  
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96  
(latest edition), available from the National Fire Protection Association,  
Batterymarch Park, Quincy, MA 02269.  
Locate the fryer under a hood with adequate connection to an exhaustduct. The  
hood must extend 6” (15 cm) beyond fryer on both sides.  
Clearance above the fryer should be adequate for combustion byproducts to be  
removed efficiently.  
An 18” (46 cm) minimum clearance should be maintained between the flue vent  
and the filters of the hood venting system.  
Never make flue connections directly to the fryer.  
Do not obstruct the flow of the gases from the appliance. Proper air balance should  
be maintained in the room.  
Ensure that your ventilation system does not cause a down draft at the fryer’s flue  
opening. Down draft will not allow the fryer to exhaust properly and will cause  
overheating which may cause permanent damage. Damage caused by down draft  
will not be covered under equipment warranty. Never allow anything to obstruct the  
flue or ventilation exiting from the fryer flue. Do not put anything on top of flue area.  
GAS CONNECTION  
All gas supply connections and any pipe joint compound must be  
resistant to the action of propane gases.  
The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff  
valve be installed in the gas line ahead of the fryer.  
The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single  
units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose,  
¾” (19 mm) iron pipe for single units and 1-1/4” (31.75 cm) iron pipe for batteries.  
Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A  
battery requires one or two connections of appropriate size for the gas requirement.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Prior to lighting, check all joints in the gas supply line for leaks.  
Use soap and water solution. Do not use an open flame.  
After piping has been checked for leaks, fully purge gas pipes to remove air.  
GAS PRESSURES (ALL MODELS):  
The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and  
10” W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an  
additional pressure regulator must be installed.  
TESTING THE GAS SUPPLY PIPING SYSTEM:  
When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve  
must be disconnected from the gas supply piping system.  
When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas  
supply piping system by closing its individual shutoff valve.  
Fryers with Casters:  
Separate instructions for installing casters are included with the casters:  
The installation shall be made with a connector that complies with the  
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CAN/CGA-  
6.16, and a quick-disconnect device that complies with the Standard for Quick-  
Disconnect Devices for Use with Gas Fuel, ANSI z21.41 CSA 6.9 or Quick-  
Disconnect Devices for Use with Gas Fuel,  
When installing a quick disconnect you must also install a means for  
limiting the movement of the fryer. This device will prevent the gas line or quick  
disconnect from being strained. The restraining device should be attached to  
the cutout on the back panel. See illustration for location.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-8-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
The fryer must be installed with a connector (not supplied by Vulcan) complying  
with the above codes.  
The fryer must be installed with restraining means to guard against transmission of  
strain to the connector. See illustration.  
The fryer must be installed with the casters provided.  
If the restraint is ever to be disconnected, first turn the gas supply off.  
LEVELING THE FRYER  
Check the level of the fryer by placing a level on top of the fryer after gas connections  
have been made.  
Ensure that the fryer is level front-to-back and side-to-side in the final installed position.  
Lock the wheels after unit is level.  
OPERATION  
Hot oil and parts can cause burns. Use care when operating,  
cleaning and servicing the fryer.  
Spilling hot frying compound can cause severe burns. Do not move  
fryer without draining all frying compound from the tank.  
OVER-TEMPERATURE SHUTDOWN  
If the shortening becomes overheated, a high-temperature shutoff device will turn the gas  
valve off and extinguish the pilot.  
If the fryer shuts down due to overheating, DO NOT relight the pilot until the shortening  
temperature is below 300 F (149 C).  
If an overheating situation persists, contact your local Vulcan-Hart authorized service  
office.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-9-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
BEFORE FIRST USE  
Cleaning  
New units are wiped down at the factory to remove any visible signs of dirt, oil, grease,  
etc. remaining from the manufacturing process.  
Before any food preparation, thoroughly wash the protective oil from all surface parts and  
the tank interior with hot soapy water to remove any film residue and dust or debris.  
Do not use chlorine or sulfate/sulfide cleaners.  
Wash any accessories shipped with unit.  
Rinse fryer and accessories thoroughly and drain the fryer.  
Wipe tank completely dry with a soft, clean cloth.  
FILLING TANK WITH SHORTENING  
Solid shortening should NOT be used with GRM fryers. Melting solid  
shortening will damage the tank and void your warranty.  
Close the drain valve.  
Fill the fryer tank with liquid shortening.  
Shortening level should be between the min and max lines in the fryer tank.  
Shortening will expand when heated. Do not ill the fryer tank past the  
MAX line.  
Add fresh shortening as needed to maintain oil level.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-10-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
LIGHTING THE PILOT  
A
B
A Thermostat Knob  
B Gas Control Handle  
1. Open the door.  
2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located  
behind the door.  
3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas  
to vent.  
4. Push and turn gas control valve knob to the “L” in PILOT (see figure below, view B).  
5. While still holding the knob in, light the pilot with a lit flame. Continue to depress  
the knob until pilot remains lit when knob is released. If the pilot does not remain lit,  
repeat step 3 through 5.  
6. Depress and turn gas control knob to ON (See figure below, view C).  
7. If gas supply is interrupted, repeat steps 2 through 6.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-11-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
TURNING ON THE FRYER  
Set the temperature knob to desired temperature.  
After the set temperature has been reached, the thermostat shuts off the gas flow  
to burners.  
The pilot remains lit. The burners will cycle on and off, maintaining the set  
temperature.  
TURNING OFF THE FRYER  
1. Turn the thermostat OFF.  
2. To keep the pilot lit, turn the gas valve to “L” in Pilot.  
3. To shut off all gas to the system, including the pilot, turn the gas valve knob to  
the OFF position.  
EXTENDED SHUTDOWN  
1. Turn the thermostat knob to OFF.  
2. Push in the pilot knob and turn to OFF.  
3. Thoroughly drain the fryer. Refer to DRAINING THE FRYER.  
4. Clean the fryer according to CLEANING.  
5. Turn off the main gas shutoff valve.  
BASIC FRYING INSTRUCTION  
Set the desired temperature and allow shortening to heat up to that temperature.  
Fry items that are the same size to ensure equal doneness.  
Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot  
shortening.  
Add fresh shortening as needed.  
Fry Basket Guidelines  
Do not overfill baskets. (See table for recommended basket capacities below)  
Carefully lower basket into oil.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-12-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
When frying doughnuts and fritters, turn product only once during frying.  
When cooking French fries or onion rings, shake the basket several times.  
Batter-covered foods should be dropped carefully, one by one, into shortening or  
basket. If you use the basket, first dip the basket into the shortening to  
reduce batter-build up on basket surfaces.  
When frying is completed, remove basket or product. Hang basket on rear  
hanger.  
Fry Basket Capacity:  
1GR35M: Recommended pounds per basket are 1.5 lbs. (0.7 kg).  
1GR45M: Recommended pounds per basket are 2.5 lbs. (1.1 kg).  
1GR65M: Recommended pounds per basket are 3.0 lbs. (1.4 kg).  
1GR85M: Recommended pounds per basket are 3.5 lbs. (1.6 kg).  
EXTENDING SHORTENING LIFE  
Shortening life can be extended by the following guidelines:  
Do not salt foods over the fryer.  
Use good-quality shortening.  
Filter shortening daily (at a minimum).  
Replace shortening if it becomes poorly flavored.  
Keep equipment and surrounding clean.  
Set thermostat correctly.  
Remove excess moisture and particles from food products before placing on fryer.  
DRAINING THE OIL  
Hot oil and hot parts can cause burns. Use care when operating,  
cleaning, and servicing the fryer.  
1. Turn the thermostat knob to the OFF position. .  
2. Insert the drain extension into the drain valve. Tighten only hand tight.  
3. Direct the drain extension into the mobile filtering device that you want to use.  
4. A cold fryer will not drain properly. Always filter shortening between 250°F  
and 350°F. The shortening in the cold zone area will remain hard if the heat is only on for  
a few minutes. If necessary, use the clean-out rod to carefully move the hard shortening  
to an area above the cold zone where it will melt.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-13-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
5. Slowly open the drain valve to allow oil to flow from the fry tank to the filter pan. Then open  
the drain valve all the way.  
6. When fry tank is empty use the tank brush to remove any additional debris.  
7. Close the drain valve.  
8. Fill tank with new shortening. Fill to a minimum of the MIN level but no higher than halfway  
between MIN and MAX. Oil will expand as it is heated.  
9. After the fry tank is filled with new oil, turn the thermostat knob to the desired set  
temperature. The burners will come on and will heat the oil.  
CLEANING  
Hot oil and hot parts can cause burns. Use care when operating,  
cleaning, and servicing the fryer.  
Daily  
Clean your fryer regularly with the tank brush along with a damp cloth, and polish with a  
soft dry cloth. If regular cleaning is neglected, grease will be burned on and discolorations  
may form.  
Fingerprints are sometimes a problem on highly polished surfaces of stainless steel. They  
can be minimized by applying a cleaner that will leave a thin oily or waxy film.  
Clean all exterior surfaces of your fryer at least once daily.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-14-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Use a damp cloth with warm water and a mild soap or detergent.  
Do not use chlorine or sulfate/sulfide cleaners.  
Rinse thoroughly, and then polish with a soft dry cloth.  
Keep the fryer exterior clean and free of accumulated grease to prevent stubborn  
stains from forming. If regular cleaning is neglected, grease will be burned on and  
discolorations may form.  
Remove discolorations by washing with any detergent or soap and water.  
Use a self-soaping, non-metallic scouring pad for particularly stubborn  
discolorations.  
Always rub with the grain of the stainless steel.  
Do not use a metallic scoring pad or harsh cleaners.  
BOIL OUT PROCEDURE  
Weekly or as required:  
1. Drain the tank as described under DRAINING THE TANK.  
2. Once the shortening has been drained, flush out scraps and sediment using the  
provided tank brush.  
3. Close the drain valve and fill tank water. Use recommended Vulcan’s Boil-Out solid  
degreaser low foaming cleaner tablets part number 956812-1 which can be ordered  
from your local dealer. Follow the instructions on the side of the package.  
Do not use chlorine or sulfate/sulfide cleaners.  
4. Solution level must be between the MIN and MAX levels on the fryer tank.  
5. Set thermostat to the temperature recommended for the solution being used. Allow  
solution to simmer for about 15 to 20 minutes.  
6. Drain the cleaning solution from the tank.  
7. Close the drain valve and refill the tank with water. Add 1 cup (1/4 L) of vinegar to  
neutralize alkaline left by the cleaner. Solution level must be between the MIN and  
MAX level on the fryer tank.  
8. Bring the solution to a simmer only, turn the thermostat off. Allow to stand for a few  
minutes.  
9. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear,  
hot water. All traces of cleaner must be removed. Dry the tank thoroughly.  
10.Close the drain valve and add shortening. Follow the FILLING TANK WITH  
SHORTENING procedure in this manual. The fryer is now ready for use.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-15-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
KleenScreen PLUS® Filtration System  
Installation and Operational Manual  
For GRMF Models  
2GR45MF Shown  
GAS KleenScreen PLUS® Models:  
1GR45MF  
1GR65MF  
1GR85MF  
2GR45MF  
2GR65MF  
2GR85MF  
3GR45MF  
3GR65MF  
3GR85MF  
4GR45MF  
ML-136785  
ML-136786  
ML-136787  
ML-136417  
ML-136418  
ML-136419  
ML-136420  
ML-136421  
ML-136422  
ML-136423  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-16-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Filtering Instructions for KleenScreen PLUS® Fryers  
General  
The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective  
tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should both  
tanks be drained at the same time.  
Assembly  
After unpacking, wash the filter pan, crumb basket and filter screen assembly. Make sure  
you remove the insert located inside the filter screen. Use dishwashing detergent and warm  
water, (parts are dishwasher safe). Rinse the filter pan, crumb basket and filter screen  
components completely and wipe all parts dry with a clean cloth.  
Pull out the filter drawer all the way leaving the filter pan opening exposed.  
Place the filter tank into the filter drawer making sure that the pins on the bottom of the filter  
pan line up with the holes in the filter drawer. Position the filter screen assembly into the  
suction tube clip in the filter pan positioning the filter screen assembly flat on the bottom of  
the filter pan. Place the primary crumb basket onto the left handle of the filter pan.  
Carefully line up the suction tube nozzle so that it mates with the oil receptacle block  
mounted on the frame of the fryer battery. Close the drawer. See Figures 1, 2 3 and 4.  
Suction Tube  
Filter Screen  
Filter Insert  
Knurled Bottom  
Fitting  
Fig. 1  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-17-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Fully assembled filter screen assembly:  
Fig. 2  
Secure Tube with  
Suction Tube Clip  
Filter Screen Lays  
Flat On Bottom of  
Filter Pan  
Fig. 3  
Micro-Filtration Fabric Envelope Assembly:  
Same Suction Tube  
Fabric Envelope Insert  
(Different from Screen Assembly)  
Fabric Envelope  
Same Clip  
Same Knurled Knob  
Fig. 4  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-18-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE  
FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER  
ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).  
Step 1  
Discard all oil from the filter vessel, (see pages 23 or 24). When the  
filter pan is empty, use a spatula and scrape off all debris left on the  
filter envelope and in the filter pan.  
Step 2  
Unscrew “S” Tube from filter by turning the Bottom Knurled fitting  
counter- clockwise.  
Step 3  
Remove SST Closure Clip by lifting off one side.  
Step 4  
Remove SST Filter Screen Insert and wash insert with hot water and  
dry thoroughly. The Filter Screen Insert is dishwasher safe. Place the  
insert into a new KleenScreen PLUS® Filter envelope.  
DO NOT WASH FABRIC ENVELOPE  
Step 5  
Place Filter Screen Insert into the fabric envelope making sure that the  
holes line up. Fold over the other end of the envelope and place SST  
Closure Clip on – hinge over and firmly press clip all the way down to  
secure and seal filter assembly. Making sure that the folded end is face  
down; screw “S” Tube Assembly onto the Filter Assembly. Tighten the  
Bottom Knurled fitting. When tightened, the “S” Tube assembly should  
be perpendicular to the long side of the filter assembly.  
Step 6  
Reposition the filter tube into the provided clip. Align filter tube so that  
the end of the “S” Tube engages the Oil Receptacle fitting each time the  
drawer is opened and closed.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-19-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Operation  
Hot oil and parts can cause burns. Use care when operating,  
cleaning and servicing the fryer.  
Spilling hot frying compound can cause severe burns. Do not move  
fryer without draining all frying compound from the tank.  
Never run water or boil out solution through filter and motor / pump. Doing so  
will void your fryer warranty.  
Solid shortening should NOT be used with GRM fryers. Melting solid  
shortening will damage the tank and void your warranty.  
FILTERING PROCEDURE WHEN USING LIQUID SHORTENING:  
Oil Temperature should be 300-350° F. Use the provided crumb scoop to remove and suspend  
crumbs on the bottom of the tank before proceeding to Step 1.  
1. Turn the Fryer temperature knob to the OFF position.  
Do NOT heat the fryer during the filtering procedure. Permanent damage to your  
fry tank may occur and warranty may be voided.  
2. Vulcan recommends adding an oil treatment media to the oil prior to filtering.  
3. Turn the Filter Power switch to the ON position. Make sure that the filter drawer is closed  
completely and that the suction tube and receptacle block are in the correct position. Fig. 5  
Fig. 5  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-20-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
4. Drain the oil out of the fry tank by turning the red handle drain valve. The filter pan will begin  
to fill with oil. When the oil level fills half of the filter pan, pull the red handled filter lever  
towards you. The motor / pump will begin and oil will flow back into the fry tank. The oil will  
flow into the back of the tank towards the front and down the drain back into the filter pan.  
Use the provided filter brush to help wash down the residue from the bottom and sides of the  
fry tank and allow it to flow down into the filter pan.  
5. Close the red handle drain valve turning off the flow of oil into the filter pan. The fry tank will  
begin to fill. It is normal to see air bubbles in the tank towards the end of filtering. The motor  
/ pump sound will change when the filter pan is empty of oil. Push in the red filter handle  
lever and turn the power switch OFF.  
6. The oil level is correct when it is between the Min / Max lines on the fry tank.  
7. Turn the Thermostat knob to the desired temperature. Burners should turn on and the oil  
should begin to heat.  
8. Repeat this procedure for the remaining tank(s) in the battery.  
9. When finished filtering, clean all of the filter components as in step 1 under Assembly  
section.  
FILTERING TIP:  
Open the filtering drawer approximately 1” to allow any oil in the return line to run back into the filter  
pan. This will take about 30 seconds to complete. Then open the drawer completely to clean filter  
components.  
REMOVING EXCESS DEBRIS FROM THE FILTER:  
1. Pull the filter drawer out and remove the crumb basket and empty any debris into the trash.  
2. Remove the filter screen assembly. Scrape debris from the filter screen. Then remove the  
insert by unlatching the latch. Clean all parts thoroughly as mentioned in the Assembly  
section on page 17.  
3. Scrape debris from the bottom of the filter pan and discard in the trash. Clean all parts  
thoroughly as mentioned in the Assembly section on page 17. Clean all parts thoroughly as  
mentioned in the Assembly section on page 17.  
4. Reassemble all filter components after being dried thoroughly as in the Assembly section on  
page 17.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-21-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
FLUSH AND DISCARD:  
1. Follow filtering instructions 1-3, however do not put oil treatment media into the fryer. Drain  
the fryer oil into the filter pan.  
2. Attach the quick disconnect hose to the discard male quick disconnect fitting.  
3. Place other end of the discard hose into a container that is large enough to retain the  
discarded shortening.  
4. To start the discard operation, turn Power Switch ON.  
5. Pull the Yellow Discard Handle Lever Rod towards you and the Motor/Pump will begin to  
operate. NOTE: Oil will come out immediately out of the nozzle end of the hose.  
6. Once the oil has been discarded completely and the filter pan is empty, push the Discard  
Lever back in. The Motor/Pump will stop and turn the Power Switch OFF.  
7. Disconnect the discard hose. Be careful to let the hose drain before putting away. Close the  
drain valve and fill the fry tank with new oil.  
BOIL OUT PROCEDURE:  
Use the Boil Out By-Pass™ drain extension allowing the boil  
out solution to exit the fry tank without using the filtering  
system. Do NOT allow water to run through the motor / pump.  
Drain the boil out solution into a bucket or place a high  
temperature rated water hose on the end of the drain extension  
allowing the other end to flow into a floor drain. In Fig. 6 the  
arrow is pointing to the drain extension. It is threaded into the  
top coupling of the oil drain tube. Drain extension needs to be  
only hand tightened.  
Fig. 6  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-22-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
THERMAL OVERLOAD PROTECTION BUTTON:  
The motor/pump supplied with the filtering system  
has a thermal overload protection circuit that senses  
when excess heat occurs due to filtering for long  
periods of time or under heavy load prior to  
discarding debris buildup. If the thermal overload  
protection is tripped, wait 5 minutes and then reset  
the motor by pushing in the red button. The arrow in  
Figure 7 shows the location of the reset button;  
located on the front off the motor / pump facing  
towards you.  
Fig. 7  
MAINTENANCE  
Hot oil and hot parts can cause burns. Use care when operating,  
cleaning, and servicing the fryer.  
Spilling hot fryer compound can cause severe burns. Do not  
move fryer without draining all frying compound from the tank.  
FLUE VENT INSPECTION  
When the fryer is cool, inspect annually. Check the flue and clear any obstructions.  
Service in the US and Canada  
Contact your local Vulcan-Hart Service office or address on the front of this manual.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-23-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GRM SERIES GAS FRYERS  
Troubleshooting Chart:  
Problem:  
No Heat:  
Probable Cause:  
Thermostat dial not turned on.  
Pilot not lit.  
Gas supply not turned on.  
Wire connections loose (call service)  
Wires connections need cleaning (call service)  
Thermopile (call service)  
Insufficient or too much heat:  
Thermostat dial not set to desired temperature.  
High limit tripped (call service)  
Temperature probe (call service)  
Tank will not drain:  
Shortening too cold.  
Drain pipe clogged with debris.  
Motor / pump will not pump oil:  
Suction tube not seated correctly in receptacle block.  
Filter screen is clogged and needs cleaning.  
Shortening is too thick / cold. Heat oil up to min. 300º F.  
Discard valve lever not fully engaged either for filtering or  
discarding.  
VULCAN-HART  
F-31233 Rev. K (February 2011)  
-24-  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Telex Network Card BP 1002 User Manual
Timex Watch W273 EU1 355 095013 User Manual
Toastmaster Clock Radio A710 User Manual
Tricity Bendix Oven BS 621 2 User Manual
Tripp Lite Switch U223 004 IND User Manual
Tyan Computer Network Card Tyan S1598 User Manual
VTech Cordless Telephone i 5836 User Manual
VTech Cordless Telephone VT 1962 User Manual
Vulcan Hart Hot Beverage Maker VDL100 User Manual
Vulcan Hart Nail Gun E30TB User Manual