Vulcan Hart Charcoal Grill MGCB18 User Manual

INSTALLATION &  
OPERATION MANUAL  
MGCB SERIES MEDIUM DUTY  
GAS CHARBROILERS  
MODEL  
MGCB18  
MGCB24  
MGCB29  
MGCB34  
ML-103821  
ML-103822  
ML-103823  
ML-103825  
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791  
FORM 31008 (11-96) (Formerly 990503)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Installation Codes and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Gas Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Testing the Gas Supply System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Before First Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Lighting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Turning the Charbroiler On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Turning the Charbroiler Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Using the Charbroiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Grease Pan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Service and Parts Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
— 3 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation, Operation and Care of  
MODEL MGCB SERIES GAS CHARBROILERS  
PLEASE KEEP THIS MANUAL FOR FUTURE USE  
GENERAL  
Vulcan charbroilers are produced with quality workmanship and material. Proper installation, usage  
and maintenance of your charbroiler will result in many years of satisfactory performance.  
It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions  
provided.  
INSTALLATION  
Before installing, verify that the type of gas supply (natural or propane) agrees with the specifications  
on the rating plate located on the inside of the front panel. If the supply and equipment requirements  
do not agree, do not proceed with the installation. Contact your dealer or Vulcan-Hart Company  
immediately.  
UNPACKING  
This charbroiler was inspected before leaving the factory. The transportation company assumes full  
responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking, check  
for possible shipping damage. If the charbroiler is found to be damaged, save the packaging material  
and contact the carrier within 15 days of delivery.  
Remove the packing bag containing the adjustable legs. Carefully unpack the charbroiler and place  
it in a work-accessible area as near to its final installed position as possible. Lift the grates and radiants  
out of the carton.  
LOCATION  
The equipment area must be kept free and clear of combustible substances.  
The charbroiler must be installed only in fire resistant locations.  
— 4 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When installed, minimum clearance from combustible construction must be 6" at the sides and 6" at  
the rear; minimum clearance from non-combusible construction must be 4" at the sides and 4" at the  
rear.  
The installation location must allow adequate clearances for servicing and proper operation. A  
minimum front clearance of 32" is required.  
Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into  
the combustion chamber must be provided. Make sure there is an adequate supply of air in the room  
to replace air taken out by the ventilating system.  
Do not permit fans to blow directly at the charbroiler. Wherever possible, avoid open windows next to  
the charbroiler. Avoid wall-type fans which create air cross currents within the room.  
INSTALLATION CODES AND STANDARDS  
The charbroiler must be installed in accordance with:  
In the United States of America:  
1. State and local codes.  
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The American  
Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.  
In Canada:  
1. Local codes.  
2. CAN/CGA-B149.1 Installation for Natural Gas Burning Appliances and Equipment (latest edition).  
3. CAN/CGA-B149.2 Installation for Propane Burning Appliances and Equipment (latest edition),  
available from the Canadian Gas Association, 55 Scarsdale Road, Don Mills, Ontario, Canada  
M3B2R3.  
ASSEMBLY  
The broiler is shipped as a complete unit and does not require field assembly except the supporting  
legs, grates and radiants.  
Screw the legs on four corners of the charbroiler into the permanently fastened nuts. Hand tighten the  
legs and set the charbroiler in place.  
Place the radiants in their position (Fig. 1). Make sure that radiants nestle properly on front and rear  
supports. CAUTION: Do not drop radiants on supports.  
Place the top grid grates in place with the grid bars sloping toward the front (Fig. 2), or with grid bars  
horizontal (facing down). When grid grates are placed sloping toward the front, the grooves on top will  
guide excess fat drippings into the grease trough.  
— 5 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 1  
Fig. 2  
— 6 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LEVELING  
Place a carpenter's level on top of the charbroiler. Level the charbroiler front to back and side to side  
by turning the adjustment screw at the bottom of each leg.  
GAS CONNECTIONS  
Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.  
Location of the gas inlet is at the rear on the right side. Codes require that a gas shutoff valve must  
be installed in the gas line ahead of the charbroiler.  
Connect gas supply. Make sure the pipes are clean and free of obstructions.  
Charbroilers are equipped with fixed burner orifices for use with natural or propane gas and no  
adjustments are necessary.  
Natural gas pressure regulators are preset for an outlet pressure of 3.7" W.C. (Water Column); propane  
gas pressure regulators are preset for 10" W.C.  
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.  
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.  
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.  
TESTING THE GAS SUPPLY SYSTEM  
When gas supply pressure exceeds 1/2 psig (3.45 kPa), the charbroiler and its individual shutoff valve  
must be disconnected from the gas supply piping system.  
When gas supply pressure is 1/2 psig (3.45 kPa) or less, the charbroiler should be isolated from the gas  
supply system by closing its individual manual shutoff valve.  
VENTILATION  
It is recommended that the exhaust fumes be ventilated to the outside of the building through a  
ventilation system installed by qualified personnel.  
Information on the construction and installation of ventilating hoods may be obtained from the standard  
for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from the  
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
— 7 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,  
CLEANING OR SERVICING THE CHARBROILER.  
CONTROLS  
The Thermostats regulate gas flow to the burners to maintain set temperature.  
BEFORE FIRST USE  
Clean the protective metal oils from all surfaces of the charbroiler. Use a non-corrosive, grease  
dissolving commercial cleaner, following manufacturer's directions. Rinse thoroughly and wipe dry  
with a soft clean cloth. Clean all accessories. Rinse thoroughly and wipe dry.  
LIGHTING INSTRUCTIONS  
Lighting instructions are also inside the front panel. To access, remove thumb screws from the upper  
front panel. Lift the upper front panel until it clears the lower front panel.  
To install the upper front panel, place panel above the lower front panel and slip upper panel down so  
it engages lower front panel.  
Lighting the Pilot  
If the pilot goes out, an automatic shutoff valve turns off the gas supply to the burners. To relight the  
pilot, follow these procedures:  
1. Turn the thermostats to the OFF position.  
2. Turn the main shutoff valve to OFF.  
3. Wait 5 minutes to allow gas which may have accumulated in the burner compartment to escape.  
4. Turn the main shutoff valve ON.  
5. Depress and hold in on the red button (Fig. 3) on the automatic shutoff valve while lighting the pilot  
burner.  
6. When gas at the pilot has been running for about 45 seconds, release the red button. If the pilot  
does not remain lighted, repeat the above procedures, allowing more time before releasing the red  
reset button.  
All initial pilot lighting adjustments must be performed by a qualified installation or service person.  
— 8 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TURNING THE CHARBROILER ON  
All burners are lit from constantly burning pilots. Turn control knobs to HI to ignite the burners.  
TURNING THE CHARBROILER OFF  
Turn control knobs to OFF.  
Extended Shutdown  
Turn control knobs to OFF. Turn the manual shutoff valve to OFF. Shut off the pilot flame by removing  
the pilot adjustment cap and turning the adjusting screw on the pilot shutoff valve (Fig. 3).  
RED  
BUTTON  
PILOT  
ADJUSTMENT  
SCREW  
PL-52472  
PILOT SHUTOFF VALVE  
Fig. 3  
USING THE CHARBROILER  
To preheat, turn control knobs to HI about 25-30 minutes before cooking time. After this period of  
preheat, grid temperatures will be in the range of 600°F for best broiling results. Then adjust the control  
knobs to the LO position to maintain the grid temperature between 575°F and 625°F.  
Do not leave the burners on with knobs in the HI position for any extended period of time beyond the  
recommended preheat time or "burn-off" time (see CLEANING in this manual).  
To minimize gas usage, operate only those burners needed for the cooking load.  
GREASE PAN  
Grease in the grease pan will not get hot enough to be ignited by the burners; however, under some  
use conditions, flaming particles may drop into the grease drawer and cause it to ignite. Only if your  
use conditions warrant, add a 1/16" deep layer of water in the grease pan to prevent this from happening.  
— 9 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING  
At least once a day, remove the grease pan, empty and wash it out in the same way you would any  
cooking utensil.  
"Burn off" the grease build-up on the grate daily or as dictated by use. Always use insulated gloves  
when handling grates or radiants to prevent burns.  
CAUTION: Do not cover the top of the grid grates during a burn-off operation. Restricting the  
air flow by covering the grid grates may cause them to warp.  
The top grid grates and radiants are heavy. They may break if dropped or bumped.  
To "burn off" the grates:  
1. Place grates on broiler with grid bars horizontal, facing down.  
2. Turn control knobs to HI for approximately 45 minutes.  
3. Turn broiler OFF and allow it to cool for 20 minutes.  
4. Clean top and bottom surfaces of grate with a wire brush to remove animal fats and carbonized  
grease.  
5. Clean channels on grates with a scraper.  
6. Remove grates from broiler. Clean top surface of radiants with the wire brush. They may be  
cleaned in place.  
7. Once a week, after completing steps 1-6, remove the radiants. Using a brush, clean reflecting drip  
shield (see Fig. 1) of any dust or debris.  
Once a week, thoroughly clean the exposed surfaces of the broiler (sides, front and top grease trough)  
with a damp cloth, then polish with a soft dry cloth. A detergent may be used for cleaning. To remove  
discolorations, use a non-abrasive cleaner.  
Burner air shutter openings must be kept clean.  
Burner ports must be kept clean. To remove burners:  
1. Remove the top grates.  
2. Remove the radiants.  
3. Remove the burners.  
Brush burner ports with a wire brush or clean ports with a sharp pointed metal instrument to ensure  
open ports.  
Reverse above procedure for reassembly.  
10 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING,  
CLEANING OR SERVICING THE CHARBROILER.  
LUBRICATION  
All valves and thermostats must be checked and lubricated periodically by your local service agency.  
SERVICE AND PARTS INFORMATION  
To obtain service and parts information concerning this charbroiler, contact the Vulcan-Hart Service  
Agency in your area (refer to listing supplied with the charbroiler), or Vulcan-Hart Company Service  
Department at the address or phone number shown on the front cover of this manual.  
11 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FORM 31008 (11-96) (Formerly 990503)  
PRINTED IN U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Texas Instruments Stereo Amplifier SLOU025 User Manual
Triarch Fan 25402 User Manual
Tripp Lite Computer Accessories NB1008BK User Manual
Tripp Lite Switch B005 008 User Manual
Tripp Lite TV Cables N201 025 GY User Manual
Vermont Casting Indoor Fireplace VCEF26 User Manual
ViewSonic Projector PJD5123 User Manual
Viking Ventilation Hood F1570J User Manual
Volvo Automobile S70 User Manual
Weber Gas Grill LPG Gas Barbecue User Manual