Vizio Computer Accessories CCU 11B User Manual

INTERCOM SYSTEM  
TOA EXES-1000 INTERCOM SYSTEM  
Central Control Unit  
CCU-11B  
INSTALLATION HAND BOOK  
TOA ELECTRIC CO., LTD.  
KOBE, JAPAN  
133-21-012-7A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. INTRODUCTION  
This manual forms part of the Installation Manual for  
TOA INTERCOM SYSTEM EXES-1000.  
For (1) Connections of Equipment, etc., refer to Manual  
of Installation Hand Book of EXES-1000 (EX-110)  
Exchange.  
You may add to the CCU-11B to your TOA INTERCOM  
SYSTEM EXES-1000, according to your specific needs,  
to obtain various other functions.  
This "Installation Hand Book of CCU-11B" deals prin-  
cipally with (2) selection of functions and setting up of  
respective equipment.  
Correct operation of these additional functions are not  
available by only connection of the additional equip-  
ments/devices.  
There are certain minimum installation requirements to  
be met even though you may not need many additional  
functions or additional equipment, it is still necessary to  
read "4. Initial CCU-11B Set Up (Page 4.)". When you may  
use only some of the additional functions or equipments,  
it is not necessary to read instructions on unrequired  
functions. Make sure, however, that careful study of the  
necessary parts of this booklet should be done before  
proceeding further.  
Provision of such additional functions requires the  
followings:  
(1) Connection of the additional equipment, as required,  
(2) Selection of functions which satisfy your needs and  
setting up these functions in the respective equipment.  
EXES-1000 Installation Hand Book  
EXES-1000 (EX-110)  
Installation Handbook of Exchange.  
or  
EXES-1000 (CCU-11B)  
Installation Handbook  
(133-21-012-7A)  
EXES-1000 Installation Handbook  
2. FUNCTIONS WHICH REQUIRE ADDITIONAL UNITS  
Functions of CCU-11B which require either the addition of specific units or processing in existing units are as men-  
tioned below.  
Additional Equip-  
ment Required  
Unit Model No.  
Remarks  
Function  
Optional amplifier (10W max.) may be  
required depending on application.  
Talk-Backfrom  
paging speaker  
TKU-11  
Talk-Back Unit  
— 2 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. PRECAUTIONS FOR INSTALLATION OF CCU-11B.  
Please read following instructions carefully to ensure  
proper operation of the CCU-11B.  
6. Even if you do not need programming functions, be  
sure to carry out initial programming and registration  
at station No. 11 when you install the new unit.  
Otherwise, some other functions may not work  
properly.  
1. Be careful about damage by static electricity as the  
CCU-11B incorporates CMOS IC's. Do not touch com-  
ponents and connectors.  
7. The Ni-Cd battery GB50-3FA1 is capable of saving im-  
portant memory registration data even at times of  
power failure and we suggest you replace it at least  
every 4 years.  
2. Turn off the AC power switch when you take out or  
insert the CCU-11B unit or any other unit.  
3. Always insert the CCU-11B unit into the "CCU" slot.  
Otherwise, there is a danger that the unit will be  
damaged.  
8. When shipping the CCU-11B unit independently, place  
the mini-jumper for battery back-up in "OFF"  
position. Then cover CCU back with cardboard, wrap  
connector section in aluminium foil and put it in a con-  
ductive bag.  
4. Make sure mini-jumper for battery back-up is always  
placed in "ON" position each time it is used.  
5. Incorrect setting of function select switches may lead  
to incorrect performance.  
PROGRAM SWITCH for No. 11 Programming  
Set this in "ON" position only at time of initial pro-  
gramming of the exchange and registration of functions.  
In this case, station No. 11 is "programming station" but  
becomes a normal station when switch is placed in "OFF"  
position.  
SW-B (1 ~ 6)/SW1 These switches  
SW-A (1 ~ 6)/SW2 select functions.  
Remote Control  
Replay Output  
(RY1 and RY2)  
Mini-Jumper for Battery Back-up.  
Ni-Cd Battery  
GB50-3FA1 (3.6V 50mAH)  
— 3 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INITIAL CCU-11B SET UP  
4
Make sure that you have turned off the AC power switch.  
Remove the CCU card from the card rack of exchange.  
Set mini-jumper on the CCU card to "BATT. ON" position.  
Set function selection DIP switches (SW-A & SW-B) on the CCU card for  
required functions.  
Insert the CCU card into the card rack of exchange, and make necessary  
connection correctly.  
Turn on the AC power switch of exchange.  
Turn on PROGRAM switch on the CCU card.  
No  
First installation?  
Yes  
No  
Is all programming data required to be cleared?  
Yes  
Initialset  
Dial operation from station #11  
Confirmation tone  
Touch ten times  
Yes  
Is Continuously Called Station necessary?  
No  
To Continuous Calling Tone  
Yes  
Is Secretary Transfer necessary?  
No  
To Secretary Transfer  
Yes  
Is Master/Sub-station necessary?  
Is Executive Priority necessary?  
To Master/Sub-station  
Yes  
To Executive Priority  
Dial operation from station #11.  
Key.  
Touch  
Turn off PROGRAM switch on the CCU card of exchange.  
Station #11 returns to an ordinary station.  
— 4 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
DIP SWITCH FOR FUNCTION SELECTION ON CCU-11B  
The DIP switches on the CCU-11B allow selection of the following functions;  
A. All Call Paging and Response  
B. Call Holding/Call Transfer  
E. PTT Control  
F. Priority and Executive Priority  
G. Remote Control  
C. Calling Tone Duration  
D. Time Interval Adjustment before All Call Paging  
H. Continuous Calling Tone  
Switches  
Functions  
DIP-SW "ON "Position  
DIP-SW "OFF "Position  
Battery "ON"  
Position  
Battery "OFF"  
Position  
1: BATT. OFF  
2: BATT. ON  
Mini-Jumper for Battery  
OFF  
OFF  
Remote Control (Door)  
Make/Break Relay Output  
Activate  
One shot Relay Output  
(4sec.)  
SW-A (SW2)  
Continues Calling Tone  
Not Activate  
OFF  
OFF  
Priority & Executive Priority  
Press to Talk Control  
Activate  
Activate  
Not Activate  
Not Activate  
Time Interval Adjustment  
before All Call Paging Pre-  
announce Tone  
1 ~ 2 sec.  
None  
SW-B (SW1)  
Calling Tone Duration  
CallTransfer  
Short (0.7 sec)  
Activate  
Long (1.3sec)  
Not Activate  
Not Activate  
All Call Paging & Response  
Activate  
OFF  
ON  
Station No. 11 is  
"Programming station'  
Station No. 11 is a  
normal station  
PROG  
sw  
Programming Switch  
— 5 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. STATION NO. 11 PROGRAMMING FOR EACH FUNCTION  
Use station #11 for programming of "Continuous Calling Tone", "Secretary Transfer", "Master/Sub-Relationship" and/or  
"Executive Priority" functions.  
Remarks:  
1. In the event of failure to touch keys for correct dialing, privacy tone will be sound.  
Re-start from the beginning.  
2. When All Call Paging is used, the registration to the station #10 can not be done.  
The following shows how to register the functions:  
1. Continuous Calling Tone  
No  
New registration ?  
Yes  
Ascertain holding tone.  
Continuously called station number  
No  
All registration finished ?  
Yes  
No  
Release ?  
Yes  
Ascertain holding tone.  
Station number to be released  
No  
Release finished ?  
Yes  
Return  
— 6 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Secretary Transfer  
New registration ?  
Ascertain holding tone  
Station Number  
of executive  
Station Number  
of secretary  
All registration finished ?  
Release ?  
Ascertain holding tone  
Station Number  
of executive  
Station Number  
of executive  
Release finished ?  
Return  
3. Master/Sub-Relationship  
New registration ?  
Ascertain holding tone  
Master station Number  
Sub-station Number  
All registration finished ?  
Release ?  
Ascertain holding tone  
Sub-station Number  
Sub-station Number  
Release finished ?  
Return  
4. Executive Priority  
New registration ?  
Ascertain holding tone  
Number of station where Executive Priority is  
registered.  
All registration finished ?  
Release ?  
Ascertain holding tone  
Number of station where registration of Executive  
Priority is release.  
Release finished ?  
Return  
— 7 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. REMOTE CONTROL RELAYS (RY1 & RY2) ON CCU-11B  
Remark: Relay Control Capacity: 30VDC, 2A  
Relays (RY1 & RY2) on CCU-11B are available for following functions.  
Relay  
No.  
DIP Switch Position  
Functions and Operations  
A
B
C
Door Remote Control (One-shot-Make Relay Output)  
Every master station can be used as a remote control device for door open-  
SW-A-3 "OFF"  
ing. Touch dial  
gives approximately 4 seconds make-contact for  
the door opening.  
RY1  
Door Remote Control (Make-Break Relay Output)  
Every master station can be used as a remote control device for door  
SW-A-3 "ON"  
opening. Touch dial  
gives continuous make-contact for door  
gives break-contact for door closing.  
opening. Then touch dial  
Power ON/OFF Remote Control  
When the system is used in conjunction with PA amplifier for the external  
All-Call paging, the power switch of the PA amplifier can be turned on/off  
SW-B-2 "OFF"  
with the relay built in the system. Touch dial  
together with the All-Call function until the function is canceled by dialing  
gives break-contact of the relay.)  
gives the make-contact  
(Remark: Touch dial  
RY2  
D
Press To Talk Control  
Touch dialing the specific station #17.  
One way conversation is activated while the Press-To-Talk bar is continu-  
ously depressed, same as the Press-To-Talk (selected simplex) function, and  
the relay is activated with continuous make-contact.  
SW-B-2 "ON"  
One way conversation is reversed when the Press-To-Talk bar is released, and  
the relay is activated with break-contact.  
— 8 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-2. Connections  
A. Connect 4-pin connector from TBM-11 (Terminal module) to P2 connection socket on the CCU-11B.  
B. RM1 terminals on TBM-11 are for the door remote control relay contacts and RM2 terminals on TBM-11  
are for the power ON/OFF remote control or press to talk remote control relay contacts.  
(Please refer to the following diagram.)  
DOOR  
YEL  
RM1  
RM2  
AC  
AC  
ORG  
RED  
BRN  
In the case of power ON/OFF remote control.  
— 9 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. PROGRAMMING LIST FOR FUNCTIONS  
Use these tables to keep a record of those functions assigned to each station.  
Function Table for Stations  
Functions  
Name  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
— 10 —  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOAELECTRIC CO.,LTD.  
KOBE, JAPAN  
Printed in Japan  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Thule Automobile Accessories 94691946 User Manual
Timex Clock Radio t736 User Manual
Toastmaster Fondue Maker RHFD2 User Manual
Toshiba DVD Player SD390EKB User Manual
Toshiba Personal Computer P300 SE3 User Manual
Trane Refrigerator CCAF User Manual
Tripp Lite Network Cables N201 007 YW User Manual
Universal Remote Control Universal Remote MRF 300 RFX150 User Manual
ViewSonic Computer Monitor VS13239 User Manual
VTech Cordless Telephone CS6328 2 User Manual