Inspire Electric Fireplace
Model: ICVCEFP01
Trim Models: ICVCTK01 Black Trim Kit,
ICVCTK02 Pewter Trim Kit
INSTALLER / CONSUMER SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE
INSTALLING AND USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS MANUAL IS NOT
FOLLOWED EXACTLY, AN ELECTRICAL SHOCK
OR FIRE MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Service must be performed by a qualified service
agency.
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE
C
US
10009472 12/06 Rev. 2
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Installation Instructions
General
1. Read all instructions before using this appliance.
2. This appliance is hot when in use. To avoid burns, do not
let bare skin touch hot surfaces. If provided, use handles
when moving this appliance. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes and
curtains away at least 3’ (914 mm) from the front of this
appliance.
13. This appliance, when installed must be electrically
grounded in accordance with local codes, with the current
CSA C22.1 Canadian Electrical codes or for US installa-
tions, follow local codes and the National Electric Code,
ANSI/NFPA No. 70.
14. Do not insert or allow foreign objects to enter any venti-
lation or exhaust opening as this may cause an electric
shock, fire or damage the appliance.
3. CAUTION: Extreme caution is necessary when any
heater is used by or near children or invalids and
whenever the heater is left operating unattended.
15. To prevent possible fire, do not block air intakes or ex-
haust in any manner. Do not use on soft surfaces, like a
bed, where openings may become blocked.
4. If possible, always unplug this appliance when not in use.
5. Do not operate any heater with a damaged cord or plug
or after the appliance malfunctions, has been dropped or
damaged in any manner.
16. This appliance has hot and arcing or sparking parts inside.
Do not use it in areas where gasoline, paint or flammable
liquids are used or stored. This appliance should not be
used as a drying rack for clothing, nor should Christmas
stockings or decorations be hung on or near it.
6. Any repairs to this appliance should be carried out by a
qualified service person.
17. Use this appliance only as described in this manual. Any
other use not recommended by the manufacturer may
cause fire, electric shock or injury to persons.
7. Under no circumstances should this appliance be modi-
fied. Parts having to be removed for servicing must be
replaced prior to operating this fireplace again.
18. Avoid the use of an extension cord because of the risk of
overheating the cord and the risk of fire. Extension cords
are for temporary use only. If an extension cord must be
used, it must be UL/CSA certified, rated at 15A (1875W),
125 V maximum with 14 AWG minimum and constructed
of two current carrying conductors with ground. A heavy
duty extension cord with the shortest length possible for
this connection is recommended and must not be longer
than 50 ft. (15.2 m). Do not coil or cover the extension
cord.
8. Do not use outdoors.
9. This heater is not intended for use in bathrooms, laun-
dry areas and similar indoor locations. Never locate this
appliance where it may fall into a bathtub or other water
container.
10. Do not run cord under carpeting. Do not cover cord with
throw rugs, runners or the like. Arrange cord away from
traffic areas and where it will not be tripped over.
11. To disconnect this appliance, turn controls to the off posi-
tion, then remove plug from outlet.
12. Connect to properly grounded outlets only.
Locating Your Fireplace
When choosing a location for your new fireplace, en-
sure the general instructions are followed. Also, for best
effect, install the fireplace out of direct sunlight.
Clearance to Combustibles
Sides (including trim assembly) ........... 0” (0 mm)
Bottom........................................... 9⁷⁄₈” (250 mm)
Top ....................................................3’ (914 mm)
Unit: EFHI4S0
SAVE THESE
INSTRUCTIONS
10009472
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Fireplace Dimensions
36”
(914 mm)
Minimum Shelf Height
(To Heater Main Body)
24����”
(615 mm )
23���"
(594 mm)
5�����”
(145 mm)
35�����” (910 mm)
9���”
(250 mm)
Minimum
From Floor
[Heater Main Body Width 32���” (832 mm)]
Do not use this fireplace if any part of it
has been under water. Immediately call a
qualified service technician to inspect the
fireplace and replace any part of the elec-
trical system which has been under water.
Electrical Specifications
Voltage
120V ac, 60 Hz
Total Amps
Total Watts
Heater Rating
Illumination
7.9 Amps
1050W
2 x 500W
2 x 20W Low Energy Bulb
Grounding Instructions
This heater is for use on 120 volts. The cord has a plug
as shown at A in Figure 1. An adapter as shown at C
is available for connecting three-blade grounding-type
plugs to two-slot receptacles. The green grounding lug
extending from the adapter must be connected to a per-
manent ground such as a properly grounded outlet box.
The adapter should not be used if a three-slot grounded
receptacle is available.
Electrical Connection
A 15 amp, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on the
same circuit may cause the circuit breaker to trip or the
fuse to blow when the heater is in operation. The unit
comes standard with a 6 ft. (1.8 m) long three wire cord,
exiting the left side of the fireplace. Plan the installa-
tion to avoid the use of an extension cord. Extension
cords are for temporary use only. If an extension cord
must be used, it must be UL/CSA certified, rated at 15A
(1875W), 125V maximum with 14 AWG minimum and
constructed of two current carrying conductors with
ground. A heavy duty extension cord with the shortest
length possible for the connection is recommended and
must not be longer than 50 ft. (15.2 m). Do not coil or
cover the extension cord.
A
Cover of
Grounded
Outlet Box
Grounding Pin
B
C
Electrical outlet wiring must comply with
local building codes and other applicable
regulations to reduce the risk of fire, elec-
trical shock and injury to persons.
Metal Screw
Adapter
Grounding Means
FP1636
Fig. 1 Grounding methods.
10009472
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Direct (Hard) Wiring Electric Fireplace
WARNING: This procedure must be conducted by a
qualified electrician, in accordance with National and
local codes. In the U.S.A., the installation must conform
to the National Electrical Code, ANSI/NFPA No. 70. In
Canada, the installation must conform to the current
CSA C22.1 Canadian Electrical Code.
is connected to the main power switch and is termi-
nated with a straight terminal connector. The neutral
wire is connected at the circuit board’s screw clamp
terminal block. The green ground wire is attached
to the ground stud. Use a 5/16” (8 mm) socket or
wrench to remove the brass nut, brass lock washer
and brass cup washer and set aside. Remove and
discard the cut power cord ground wire.
WARNING: Make sure the power to the unit is off, and
the power cord is unplugged from the wall outlet before
proceeding with this conversion. Failure to do so may
result in property damage, personal injury or loss of life.
Warning: Make sure the power to the power cable
has been turned off at the breaker/fuse panel before
proceeding.
This instruction is intended as a guide for replacing
the power cord supplied with the electric fireplace with
direct (hard) wiring.
8. Using a slotted screwdriver, remove the 7/8” (22
mm) diameter knockout above the old power cord
strain relief.
NOTE: When direct wiring this appliance, it must be
connected to a 15 Amp dedicated circuit breaker or
fuse in the electrical panel of the dwelling. The cable
between the circuit/fuse panel and the fireplace must
meet all local and national codes, and in no case shall
the wires be less than 14 gauge.
9. Route the power cable from the breaker/fuse panel
through the 7/8” (22 mm) diameter hole. Secure the
cable to the compartment using an approved clamp.
The wires should extend approximately 6” (152 mm)
into the compartment.
1. Make sure the power to the unit has been turned
off, the master ON/OFF switch located under the
appliance on the left hand side is turned off, the
power cord is unplugged from the wall outlet and
the appliance has cooled down.
10.Connect the ground wire from the power cable by
wrapping it around the ground stud of the unit and
securing it firmly with the brass cup washer, brass
lock washer and brass nut.
11.Using wire strippers, strip approximately 5/8” (15
mm) from the ends of the hot and neutral wires.
Using an approved wire nut, connect the hot lead
(black) of the power cable to the power cord wire
that ends at the main power switch. Similarly, using
another wire nut, connect the neutral wire (white),
of the power cable to the power cord ending at the
screw clamp terminal block of the circuit board. It
is recommended that the wire nuts be taped to the
wires, using electrical tape, as an extra safety mea-
sure.
2. Follow Steps 1 through 4 in “Light Bulb
Replacement” section, Page 9.
3. Remove two (2) screws per side for the brackets
and the fireplace screen to be removed and set
aside.
4. Remove one (1) screw per side of the bulb housing
assembly to remove and set aside.
5. Remove two (2) screws per side for the left side
cover. This allows the cover to be opened for
access to where the power cord enters the strain
relief and the compartment.
12.For extra safety measure, visually check and fix the
wire routing appropriately. Refer to the wiring dia-
gram on the unit or in the instruction manual if any
wires have been dislodged.
6. Using wire cutters, gently cut the power cord inside
the compartment, flush to the strain relief. Also,
repeat for the power cord outside the compartment.
13.Turn the power to the unit on at the breaker/fuse
panel. Place the appliance into operation and check
to make sure all of the systems are working prop-
erly
7. Back inside the compartment, gently separate the
three (3) wires of the power cord into separate wires
by gently pulling them apart. DO NOT use a knife,
as this may expose bare conductors. The hot wire
10009472
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Fireplace Assembly
Unpack the Appliance
4. Measure half the width [16³⁄₈” (416 mm)] of the
heater main body and mark a vertical line to cross
the horizontal line. If the heater main body is to be
centered on the wall area, mark a vertical center line
to cross that horizontal line. Where the horizontal
and vertical marks cross is the location of the upper
center mounting hanger hole.
The Inspire Electric Heater is supplied in two (2) car-
tons. All instructions should be read before beginning
installation.
Carton 1 contents
1, Electric heater main body
1, Remote control handset with battery
1, Mounting hanger
1, Mounting hardware kit [#12 x 1/2” long screws (6),
wall anchors (6), #8 x 1/4” short screws (4)]
1, Installation instructions
5. Use an appropriate level and mark and measure the
locations for the remaining holes of the mounting
hanger. Use the mounting hanger as a template.
6. Use the long screws provided to mount the hanger
in place. A #3 Phillips screwdriver is recommended.
Depending on the wall type, proper anchors have to
be used. For your convenience, expansion anchors
are provided. Be sure to check the anchors for suit-
ability for the wall type.
1, Pebble pack
2, Insert panels
Carton 2 contents
1, Trim assembly w/ six (6) magnets
7. Mount the heater main body to the hanger.
Appliance Mounting
Heater Assembly
The heater must be mounted to a suitable wall using
the mounting hanger provided. Consider the minimum
clearance dimensions referenced on Page 3 and 4 for
the mounting location. The following steps are for one
method that can be used at your own risk. A helper is
recommended.
Before assembling the trim to the heater main body,
arrange the pebbles onto the plastic front form (ember
lava rock), to give the best decorative effect. Refer to
front cover for example. If necessary, the side brackets
for the plastic front form may need to be removed to fit
and reinstall.
1. Become familiar with the mounting hanger and how
it fits to the rear of the electric heater main body.
(Fig. 2)
Trim Assembly
Place the trim insert panels on either side of the trim
and secure to the trim using the screws provided. (Two
(2) screws on either side)
Mounting Hanger
1. Remove the protective plastic bag and place the trim
on it to prevent any damage to the front while work-
ing.
2. Peel off the protective plastic coating (if available) on
the insert panel.
3. Place the insert panel on either side as shown in
Figure 3. Secure each panel using two (2) short
screws. The screws fit into slots in the trim. A me-
dium #2 Phillips screwdriver is recommended.
4. Double the six (6) magnets and place on the trim in
three locations as shown in Figure 4.
Wiring Diagram
FP1731
Fig. 2 Rear view of Inspire with mounting hanger in place.
2. Locate the heater main body on the wall and mark
(erasable) either the bottom or top edge and one
side for the heater location. If the heater is to be
centered on the wall area, the side mark is not nec-
essary. Set the heater main body down.
3. Mark a horizontal line 21¹⁄₈” (536 mm) from the lower
line or 2¹⁄₄” (58 mm) from the upper line.
10009472
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Insert Panel
Magnets
FP1638
Fig. 3 Place insert panels on either side of trim.
FP1637
Magnets
5. Hang the trim to the heater main body’s upper trim
support at a slight angle and between the trim insert
panels. Slowly, swing the trim down until the mag-
nets catch to the heater main body.
Fig. 4 Trim magnet location.
10009472
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Operating Instructions
Heater Operation
The heater is operated by the remote control handset.
A master ON/OFF switch is located under the appliance
on the left hand side. This is used to turn the appliance
completely off.
Fire On/Flame
Effect Only
Fire Off
All further operations are controlled by using the remote
control handset. (Fig. 5)
1. Ensure the appliance is plugged in and switched on.
Low Heat
On/Off
High Heat
On/Off
2. To turn the fire on, press the fire on/flame effect but-
ton.
3. For low heat, ensure the flame effect is on and press
the low heat button once. To turn the low heat off,
press the low heat button a second time. The fire will
now be running with flame effect only.
FP1639
Fig. 5 Remote control handset.
4. For high heat, ensure the flame effect and low heat
settings have been switched on. Press the high
heat button. The high heat button will only work if
the flame effect and low heat have already been
switched on. To turn high heat off, press the high
heat button a second time. The fire will now be run-
ning with low heat.
Switch
Marking Operation
Master ON/OFF
O I
On/Off. Depress to I,
this supplies power to the
appliance and places it in
a standby mode.
5. To place the fire in a standby mode at any time,
press the fire off button.
Frequency Setting Information
Example of Frequency Setting
Dial Set
Switch Set
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
ON/ON/ON/ON
ON
ON/ON/ON/OFF
ON/ON/OFF/ON
ON/ON/OFF/OFF
ON/OFF/ON/ON
ON/OFF/ON/OFF
ON/OFF/OFF/ON
ON/OFF/OFF/OFF
OFF/ON/ON/ON
OFF/ON/ON/OFF
OFF/ON/OFF/ON
OFF/ON/OFF/OFF
OFF/OFF/ON/ON
OFF/OFF/ON/OFF
OFF/OFF/OFF/ON
OFF/OFF/OFF/OFF
1
2
3
4
Switch Set = ON ON OFF ON
Dial Set = C
NOTE: The frequency setting of the RF transmitter label
affixed on the lower left front of the unit must match the
dial setting on the rear of the remote control handset.
10009472
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
Maintenance
WARNING
Before carrying out any maintenance, ensure the
appliance is disconnected from the main power
supply. If in doubt, seek the assistance of a quali-
fied technician.
It is advisable to use genuine CFM Corporation replace-
ment parts available from your authorized dealer.
Removable Panel
Light Bulb Replacement
1. Disconnect the appliance from the main power sup-
ply.
2. Remove the decorative trim assembly.
3. Remove the pebbles and ember bed.
4. Remove the removable panel by unscrewing the four
(4) screws. (Fig. 6)
5. Remove the colored filter from the bulb and unscrew
the bulb from its housing. (Fig. 7)
Remove Screws
FP1640
6. Install the new 20W light bulb.
7. Reassemble in reverse order.
Fig. 6 Removable panel.
Care and Cleaning
Always disconnect the appliance from the main power
supply and allow to cool before any cleaning operation
begins.
Metal painted parts may be cleaned using a clean,
damp cloth. Never use any abrasive cleaners and
chemical agents as these may damage the paint finish.
Light Bulb
Light Bulb
FP1643
Color Film
Fig. 7 Remove color film and remove light bulbs.
10009472
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
1
3
5
4
6
7
8
9
10
CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time,
without notice.
Inspire Replacement Parts
Ref. Description
Part Number
B-98830
1. 20W Energy Saving Bulb*
2. Pebble Pack (not shown)
3. Colored Filter
B-81770
B-99670
4. Ember Lava Rock
5. Circuit Board
B-93420
B-99610
6. Transmitter
7. Fan Heater
8. Flame Blower
B-100990
1097-99660
B-99580
9. Power Cord
B-99590
10. Landscape Electric Screen
B-91130
*Alternate: 20W Energy Saving Bulb - Sylvania CF20EL/830/MED/1
10009472
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Inspire Electric Fireplace
1 YEAR WARRANTY
For Vermont Castings Electric Fireplace
BASIC WARRANTY:
CFM Corporation (hereinafter referred to collectively as
the “Company”) warrants that your new electric fireplace
is free from manufacturing and material defects for a
period of one year from date of installation, subject to the
following conditions and limitations.
7. All other warranties - expressed or implied - with respect
to the product, its components and accessories, or any ob-
ligations/liabilities on the part of the Company are hereby
expressly excluded.
8. The Company neither assumes, nor authorizes any third
party to assume, on its behalf, any other liabilities with
respect to the sale of this Vermont Castings product.
1. This electric fireplace must be installed and operated at all
times in accordance with the Installation and Operating in-
structions furnished with the product. Any alteration, willful
abuse, accident, or misuse of the product shall nullify this
warranty.
9. The warranties as outlined within this document do not ap-
ply to non-CFM Corporation accessories used in conjunc-
tion with the installation of this product.
2. This warranty is non-transferrable, and is made to the
original owner, provided that the purchase was made
through an authorized supplier of the Company.
This warranty is void if:
a) The fireplace has been operated in atmospheres
contaminated by chlorine, fluorine or other damaging
chemicals.
3. This warranty is limited to the repair or replacement of
part(s) found to be defective in material or workmanship,
provided that such part(s) have been subjected to normal
conditions of use and service, after said defect is con-
firmed by the Company’s inspection.
b) The fireplace is subjected to prolonged periods of
dampness or condensation.
c) Any alteration, willful abuse, accident, or misuse of the
product.
4. This warranty does not cover the lightbulb(s) included
IF WARRANTY SERVICE IS NEEDED . . .
with the fireplace.
1) Contact your supplier. Make sure you have your warranty,
your sales receipt, and the model/serial number of your
CFM Corporation product.
5. The Company may, at its discretion, fully discharge all
obligations with respect to this warranty by refunding the
wholesale price of the defective part(s).
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOUR-
6. Any installation, labor, construction, transportation, or
other related costs/expenses arising from defective part(s),
repair, replacement, or otherwise of same, will not be
covered by this warranty, nor shall the Company assume
responsibility for same. Further, the Company will not be
responsible for any incidental, indirect, or consequential
damages, except as provided by law.
SELF.
10009472
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CFM Corporation
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3
Download from Www.Somanuals.com. All Manuals Search And Download.
|