Verilux Indoor Furnishings CWST1 User Manual

CWST1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
Thank you for purchasing the Verilux® ClearWave® Deluxe Phototherapy  
Skincare System. Please read the following safety information before  
using.  
IMPORTANT:  
• Verilux® does not make any  
medical claims. This product is  
not intended to treat or prevent  
any illness.  
• It is recommended that you  
consult a medical professional  
before using the ClearWave®.  
• Before plugging in the  
ClearWave®, check to make  
sure the voltage corresponds  
with the main voltage of your  
location (120 volts).  
• Do not use the ClearWave®  
outside or in wet locations such  
as bathrooms. It is rated for  
indoor, dry use only.  
• The light bulbs may become  
loose during transit. To reinstall  
the light bulbs, see the bulb  
replacement instructions.  
• The Verilux® ClearWave® is an  
electrical device.  
DO NOT USE NEAR WATER  
It is advisable that you contact  
a doctor if:  
You are hypersensitive to  
light and/or experience eye  
discomfort.  
You are currently taking certain  
light sensitive drugs such as  
Tetracycline.  
• There is no improvement after  
using the ClearWave® Deluxe  
for 12 weeks, or if you feel  
uncomfortable.  
• Children should be supervised  
around the ClearWave®.  
• Not for use with light dimmers,  
timers, or motion detectors.  
• This product may cause  
interference with radios,  
You have a history of eye  
disease.  
cordless telephones, or devices  
that use a wireless remote  
control, such as televisions. If  
interference occurs, move the  
product away from the device,  
plug the product or device into  
a different outlet, or move the  
product out of the line of sight of  
the remote control receiver. This  
product complies with part 18  
of FCC.  
• Do not treat the genitalia.  
• Do not use if you are pregnant.  
• If your skin responds negatively,  
discontinue use and consult a  
dermatologist.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
THIS PRODUCT MUST BE GROUNDED.  
This product is equipped with a cord having an equipment–grounding  
conductor and a grounding plug. The plug must be plugged into  
anappropriate outlet that is properly installed and grounded in  
accordance with all local codes and ordinances.  
DANGER  
Improper connection of the equipment–grounding conductor can  
result in a risk of electric shock. Check with a qualified electrician or  
serviceman if you are in doubt as to whether the product is properly  
grounded. Do not modify the plug provided with the product – if it  
will not fit the outlet, have a proper outlet installed by a qualified  
electrician. This product is for use in a nominal 120 volt circuit, and has  
a grounding plug that looks like the plug illustrated in sketch (Fig. A). A  
temporary adapter that looks like the adapter illustrated in Fig. B may  
be used to connect this plug to a 2-pole receptacle as shown in Fig. B,  
if a properly grounded outlet is not available. The temporary adapter  
should be used only until a properly grounded outlet (Fig. A) can be  
installed by a qualified electrician. The green colored rigid ear, or lug  
extending from the adapter must be connected to a permanent ground  
such as a properly grounded outlet box cover. Whenever the adapter is  
used, it must be held in place by a metal screw.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS FOR USE  
To use the ClearWave® Deluxe Phototherapy Skincare System:  
1. Plug into properly grounded  
5. Turn your face occasionally to  
outlet.  
ensure overall exposure.  
2. Turn the unit on using the on/off 6. Based on research, a 15 minute  
switch. Allow a few minutes at  
the start of each session for  
bulbs to achieve full illumination.  
session daily for 8–12 weeks  
should produce the desired  
results.  
3. Gently wash the affected parts  
of the skin with a neutral PH  
soap and dry the skin.  
7. While using ClearWave®,  
you may talk on the phone,  
meditate, or listen to music.  
4. Place the goggles (supplied)  
over your eyes, position yourself  
within 6 inches of the front of  
the ClearWave® (Figure 1).  
8. When finished with the  
session, turn ClearWave® off,  
remove goggles, and unplug  
ClearWave® from the wall.  
Figure 1  
Note: ClearWave® does not contain harmful UV and WILL NOT cause  
sunburn or skin cancer with repeated use.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS FOR USE  
Hanging the ClearWave®  
Place the screw included into the wall  
leaving approximately 3mm between the  
screw head and the wall. Be sure to use  
an the included anchor if mounting into  
sheet rock or other soft material. Insert  
the screw head into the hole located in  
the upper part of unit. (Figure 2).  
Figure 2  
Standing the ClearWave®  
on a Table Top  
Unfold the stand on back of lamp  
(Figure 3) and place the ClearWave®  
on a stable, flat surface.  
Figure 3  
Transporting the Unit  
The ClearWave® is very light and easy to carry.  
There is a convenient handle located on the  
back (Figure 4).  
Figure 4  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
BULB REPLACEMENT INSTRUCTIONS  
Step 1: Opening the  
Lens Cover  
Place the ClearWave® on its  
back on a large flat surface.  
Press down gently on the  
center of the lens cover. (See  
Figure 5). This releases the  
locking tabs located under  
the grey handles. Open the  
lens cover by grasping the  
grey handles with your hands.  
Remove the lens and gently  
place it next to the unit with  
the logo face up.  
Step 2: Opening the  
Bulb Clips  
Locate the clear plastic clips  
across each fluorescent tube  
(Figure 6). Put a finger under  
the clear plastic clip on the  
outer side and pull up (See  
Figure 7). The clip should pop  
open. Repeat on other side.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
BULB REPLACEMENT INSTRUCTIONS  
Step 3: Removing Bulbs  
Gently lift the fluorescent tube up  
and out of the clip holder. Grasp  
the tube by the white plastic base  
with the Verilux® logo and remove  
the tube from the socket by pulling  
the tube towards the black cushion  
pads. (See Figure 8). Repeat  
removal of the second bulb.  
Step 4: Installing New Bulbs  
Ensure the ClearWave® is on its  
back on a large flat surface. Hold  
the fluorescent tubes by the white  
plastic base, not the glass. Ensure  
the Verilux® logo is facing up. Line  
up the pins on the base of the  
fluorescent tube with the holes  
in the socket. Gently push the  
bulb into the socket until it snaps  
securely in place. Repeat on other  
side.  
Bulb Disposal: All fluorescents contain some amount of mercury.  
Some states have special requirements regarding their disposal.  
1-866-300-5606 for more information.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
BULB REPLACEMENT INSTRUCTIONS  
Step 5: Closing the Bulb Clips  
Ensure the plastic bulb clips are  
centered on the white protective  
bands. Gently push on the upper  
portion of the fluorescent tube  
until it slides snuggly into the  
clear plastic clip. Close the clip  
over the tube. The clip will click  
when fastened. Repeat on other  
side. (Figure 9).  
Step 6: Replacing the Lens  
Cover  
Align the lens cover over the  
open face of the unit with the  
ClearWave® logo at the bottom of  
the lamp. Place your thumbs one  
inch beyond the grey handles  
towards the center of the unit  
while your other fingers grasp  
under the lip of the grey handles  
(see Figure 10). Pull outward  
with your fingers while pushing  
down on the lens with your  
thumbs. Release your fingers to  
snap the lens into place.  
Plug your ClearWave® into an  
electrical socket and turn it on to  
ensure the bulbs were properly  
installed into their sockets. If the  
bulbs do not illuminate, ensure  
the bulbs are fully seated into the  
sockets.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE & CLEANING  
Your ClearWave® Deluxe Phototherapy Skincare System is made from  
high quality materials that will last for many years with minimum care.  
You may want to periodically clean the inside of the lens and outside  
parts, using a mild non-abrasive cleaner and soft cloth. When cleaning,  
make sure you have turned off and unplugged the unit, and allowed  
sufficient time for the unit to cool.  
DO NOT USE SOLVENTS OR CLEANERS CONTAINING  
ABRASIVES, OR AMMONIA BASED CLEANERS  
Cleaning the lens is important for maintaining optimum light output.  
Periodically remove the lens (refer to lens removal instructions) and  
clean with soft damp cloth. All liquid should be properly wiped away  
and dried prior to restoring power.  
TROUBLESHOOTING  
Light flickers.  
Only one bulb illuminates.  
If only one bulb illuminates, it  
is most likely a bad bulb.Try  
swapping bulbs and turn on again.  
If the same bulb fails to illuminate  
in the swapped position, the bulb  
needs to be replaced.  
If bulb flickers when turned on,  
the bulb is not seated fully into the  
socket. If this occurs, repeat the  
bulb installation process applying  
additional force to ensure that the  
bulb is inserted fully into the socket.  
Does not illuminate.  
Make sure that the bulbs are  
secured into the sockets.  
Sometimes in shipping they  
will come loose. Try a different  
grounded outlet. In many cases,  
this will correct the problem.  
Bulb blackening at the ends.  
This is a common phenomenon  
with most fluorescent tubes as they  
age. The black areas don’t affect  
operation except to slightly reduce  
the amount of light available since  
the phosphor in that area is dead.  
Bulb replacement is recommended.  
IMPORTANT – Grounded outlets  
must be used for proper function  
of the unit. If both bulbs do not  
illuminate when you apply power,  
this may indicate an internal  
problem. Please call Verilux®  
Customer Service at  
NOTICE – When returning a unit,  
be aware that damage during  
shipping is the responsibility of  
the purchaser and will void any  
warranty claim.We recommend  
that you purchase insurance when  
shipping this unit or any parts. Be  
sure to return product in original  
packaging.  
1-888-544-4865.  
See Warranty section.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

TMC Telephone ET4300 User Manual
Toshiba Projector TDP S21 User Manual
Tricity Bendix Kitchen Entertainment Center EG 205 User Manual
Tripp Lite Surge Protector ISOBAR825ULTRA User Manual
Tripp Lite TV Cables N001 050 BK User Manual
USRobotics Network Card Instant802 APSDK User Manual
Vivitar Copier 5HH70770 User Manual
Vizio Stereo Equalizer E 131 User Manual
Wasp Bar Code Barcode Reader WLR8900 User Manual
Weed Eater Blower 530086692 User Manual