Vent a Hood Ventilation Hood XR9 XRH9 User Manual

UNDER CABINET RANGE HOOD SPECIFICATIONS  
F/XR9/XRH9 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected  
models.  
9”  
9”  
2 ¼”  
2 ¼”  
F (Fluorescent Lights Only)  
Connection Diagram (30”- 48” Widths)  
XR9/XRH9  
Recommended  
Mounting Height*  
1 ¾”  
5 ¼”  
1 3⁄8”  
5 ½”  
5 ¼”  
Wall Side  
Wall Side  
Vent  
Holes  
Soffit  
Vent  
Hole  
1 ¾”  
Electrical  
Electrical  
8Outlet  
Cabinets  
6Outlet  
Centerline  
of Hood  
3 ¼”  
Centerline  
of Hood  
9”  
300 CFM B100 Single Blower  
(Top View)  
600 CFM B200 Dual Blower  
(Top View)  
24”-27”  
Connection Diagram (42” - Wider)  
10Round  
10Round  
7 516”  
7 516”  
1 ¾”  
5 ½”  
1 7⁄8”  
Wall Side  
36”  
Vent  
Holes  
17 ½”  
Electrical (2)  
6Outlet  
5 ¼”  
*Exceeding recommended  
mounting height may  
compromise performance.  
8Round  
8Round  
6Round  
Centerline  
of Hood  
8Outlet  
2”  
VP562 Transition (Optional) For B300  
(B200 Dual Blower & B100 Single Blower)  
900 CFM B200 Dual & B100 Single Blower  
(Top View)  
10OR 12”  
Round  
Connection Diagram (48” - Wider)  
11”  
5 ½”  
11”  
12Round  
12Round  
5 ½”  
Wall Side  
Vent  
Holes  
16 ½”  
1 ¾”  
8Outlet  
5 ¼”  
Electrical (2)  
VP562/VP563  
transition  
8Outlet  
Centerline  
of Hood  
8Round  
8Round  
8Round  
3”  
centers outlet  
over top of hood  
VP563 Transition (Optional) For B400  
(Double B200 Dual Blowers)  
1200 CFM Double B200 Dual Blowers  
(Top View)  
Electrical/Mechanical Specifications For Blower Units  
CFM  
CFM  
CFM  
CFM  
Minimum Round Square  
Model  
Volts  
Amps*  
RPM  
Equivalent CFM#  
Duct Size  
Inches  
28  
B100 Single  
B200 Dual  
115  
115  
1.7  
3.4  
1550  
1550  
300  
600  
450  
900  
286  
572  
270  
540  
240  
480  
6” (or equivalent)  
8” (or equivalent)  
50  
* Note: Add 2.5 amps for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (1 for each single or dual blower) or with halogen lights (2 lights: 30” - 41”, 3 lights: 42” - 53”, 4 lights: 54” - 66”, +1 light for each 16” if over 66”).  
#Because the Magic Lung® uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently  
than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.  
U
C
US  
R
L
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 04/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Timex Watch W 263 User Manual
Toshiba Cash Register FS 1450 User Manual
Toshiba CRT Television 32A14 User Manual
Toshiba Digital Camera IK WB15AIP User Manual
Tote Vision Computer Monitor LCD 560 User Manual
Traulsen Refrigerator UL Series User Manual
TRENDnet Network Hardware TEW640MB User Manual
Vulcan Hart Electric Steamer VHX24E User Manual
Vulcan Hart Food Warmer VCRH12 User Manual
Vulcan Hart Hot Beverage Maker K20EL User Manual