Vantec Computer Drive UGT IS602R User Manual

2+1 SATA 6G & PATA PCI-E  
COMBO HOST CARD WITH RAID  
User Manual  
Model: UGT-IS602R  
All brand names and trademarks are properties of their respective owners.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Model:  
UGT-IS602R  
Bus interface: PCI-Express 2.0 x 1  
Ports:  
2 x Internal SATA 6G ports (Backward compatible  
with SATA 3.0Gbps & 1.5Gbps)  
1 x Internal IDE/PATA port  
Dimension:  
119 x 90 x 18mm  
OS Support:  
Windows® XP/2003/Vista/2008/7 (32/64 bit)  
System Requirements  
z
Windows® XP/2003/Vista/2008/7 (32/64 bit)  
z
Computer with one available PCI-e slot  
(CD-Rom Drive May Be Needed For Drivers)  
Package Contents  
z
1 x 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH  
RAID  
z
z
z
1 x Driver CD  
1 x User’s Manual  
1 x IDE/PATA Cable  
UGTIS602R  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
2 x SATA Data Cable  
Layout  
Before Installing the Vantec 2+1 SATA 6G & PATA PCI-E COMBO  
HOST CARD WITH RAID, please see the photo below highlighting  
the available SATA6G, IDE/PATA ports of the card.  
P1 & P2: SATA6G Ports  
P3: IDE/PATA Port  
UGTIS602R  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Installation  
1. Turn off the power to your computer.  
2. Unplug the power cord and remove your computer’s cover.  
3. Remove the slot bracket from an available PCIe slot.  
4. To install the board, carefully align the card’s bus connector with  
the selected PCIe slot on the motherboard. Push the board down  
firmly.  
5. Attach your internal devices to the 2+1 SATA 6G & PATA PCI-E  
COMBO HOST CARD WITH RAID.  
6. Replace the slot bracket’s holding screw to secure the card.  
7. Replace the computer cover and reconnect the power cord.  
Creating and Managing Virtual Disks  
Creating Virtual Disks  
This section describes the produce for creating virtual disks using the  
BIOS Configuration Wizard.  
To create a virtual disk  
1. In the Topology pane, scroll to HBA0: Marvell 0 and press Enter  
to select. A menu pops-up, as shown in Figure 1.  
Select Configuration Wizard and press Enter to begin creating  
UGTIS602R  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the virtual disk.  
Figure 1 Configuration Wizard  
2. Press Space to select/unselect a disk, as shown in Figure 2. Use  
the arrow keys to scroll the list of free disks.  
Figure 2 Select Free Disks  
UGTIS602R  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD  
WITH RAID supports the creation of RAID 0 and RAID 1 virtual  
disks comprising of exactly two SATA physical disks. PATA  
physical disks cannot be used to create RAID virtual disks.  
3. After selecting the required disks, press Enter to continue, as  
shown in Figure 3.  
Figure 3 Confirm Disk Selection  
UGTIS602R  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Create Virtual Disk by configuring its setting in the Information  
pane, as shown in Figure 4.  
The controls for making selection are listed in the Help pane  
when an available setting is highlighted.  
Figure 4 Configure Virtual Disk  
UGTIS602R  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: Max size (MB) and Disk ID are properties of the virtual  
disk that cannot be edited. Max size (MB) in the size of the RAID  
virtual disk as determined by the selected RAID Level. Disk ID  
lists the IDs of the physical disks comprising the virtual disk.  
5. RAID Level, as shown in Figure 4, is highlighted when the  
Create Virtual Disk screen is presented. Press Enter to select a  
RAID Level. A menu pops-up, as shown in Figure 5, and lists  
available RAID levels.  
6. Scroll the list, as shown in Figure 5, and press Enter to select a  
RAID Level (RAID 0, RAID 1).  
Figure 5 RAID Level  
UGTIS602R  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The default Level is RAID 0.  
7. Scroll to Stripe Size and press Enter to select.  
A menu pops-up, as shown in Figure 6, and lists available stripe  
sizes for the selected RAID level.  
8. Scroll the list, as shown in Figure 6, and press Enter to select  
Stripe Size (32K, 64K)  
Figure 6 Stripe Size  
UGTIS602R  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The default size is 64 KB.  
9. Scroll to Gigabyte Rounding and press Enter to select.  
A menu pops-up, as shown in Figure 7, and lists available stripe  
sizes for the selected RAID level.  
10. Scroll the list, as shown in Figure 7, and press Enter to select  
Gigabyte Rounding (None, 1G, 10G)  
Figure 7 Gigabyte Rounding  
UGTIS602R  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The default setting for Gigabyte Rounding is 1G.  
11. Scroll to Quick Init and press Enter to enable to disable quick  
initialization of the virtual disk.  
A menu pops-up, as shown in Figure 8, and lists available options  
for quick initialization of the virtual disk.  
12. Scroll the list, as shown in Figure 8, and press Enter to select  
Quick Init (Yes, No).  
Figure 8 Quick Init  
UGTIS602R  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The default setting for Quick Init is Yes.  
13. Scroll to VD Name and the Default name is cleared for a new  
name, as shown in Figure 9.  
Type a new name and press Enter to confirm the selection.  
Figure 9 VD Name  
UGTIS602R  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. After configuring the virtual disk, scroll to Next, as shown in  
Figure 10.  
Press Enter to create the virtual disk.  
Figure 10 Create Virtual Disk  
UGTIS602R  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15. Please Y to select Yes, as shown in Figure 11, to confirm the  
creation of the virtual disk. The virtual disk is now listed in the  
Topology pane, as shown in Figure 12.  
Figure 11 Create Virtual Disk Confirmation  
UGTIS602R  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 12 Virtual Disk in Topology Pane  
UGTIS602R  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Managing Virtual Disks  
This section contains the following topics:  
z
z
z
z
Viewing Properties of Virtual Disk  
Erasing RAID Configuration Data  
Rebuilding Virtual Disk  
Deleting Virtual Disk  
Viewing Properties of Virtual Disk  
To view the properties of a virtual disk, scroll to the Virtual Disk (VD  
0: Default in Figure 13) in the Topology pane. The properties of the  
virtual disk are displayed in the Information pane when VD 0:  
Default is highlighted, as shown in Figure 13.  
Figure 13 Virtual Disk Properties: Functional VD  
UGTIS602R  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Erasing RAID Configuration Data  
Note: The RAID controller stores RAID configuration data on all  
physical disks that are part of a virtual disk. RAID configuration data  
must be erased on the physical disk before it can be used with another  
virtual disk.  
1. In the Topology pane, select Physical Disk (VD 0: Default > PD  
0: ST3750330MS in Figure 14) and press Enter.  
A menu pops-up, as shown Figure 14.  
2. Select Delete to delete the virtual disk, as shown in Figure 14.  
3. Select Yes when prompted to confirm the erase operation.  
UGTIS602R  
Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 14 Erase RAID Configuration Data  
Rebuilding Virtual Disk  
Note: The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD  
WITH RAID BIOS supports manual rebuilding of RAID 1 virtual  
disks. The rebuild process is both initiated and complete in the BIOS.  
The Marvell RAID Utility (MRU), which runs in an OS environment,  
cannot be used to either initiate, resume, or complete the rebuild  
process. Spare physical disks are not supported.  
To manually rebuild a RAID 1 virtual disk  
1. When a virtual disk is degraded, the Status of a virtual disk is  
UGTIS602R  
Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
changed from Functional to Degrade, as shown in Figure 15.  
Figure 15 Virtual Disk Properties: Degrade VD  
2. Replace the faulty physical disk with an identical physical disk.  
Note: If an identical disk is unavailable, use a replacement  
physical disk or larger size or one with a slightly smaller size as  
determined the Gigabyte Rounding setting for the virtual disk.  
The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH  
RAID detects the new physical disk and lists the device under  
Free Physical Disks in the Topology pane, as shown in Figure 16.  
Figure 16 Replace Physical Disk  
UGTIS602R  
Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. In the Topology pane, scroll to Virtual Disks (VD 0: New_VD in  
Figure 17), and press Enter to select.  
A menu pops-up, as shown in Figure 17  
Scroll to Rebuild and press Enter to configure the rebuild  
process.  
Figure 17 Rebuild Virtual Disk  
UGTIS602R  
Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Scroll through the list of free disk, as shown Figure 18, and press  
Space to select or unselect a replacement physical disk.  
Press Enter to continue.  
Figure 18 Select Replacement Disk  
UGTIS602R  
Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Press Y to select Yes, as shown in Figure 19, when prompted to  
confirm the rebuild process.  
Figure 19 Confirm Rebuild Virtual Disk  
UGTIS602R  
Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. The status of the Rebuild process is reflected in the properties of  
the virtual disk, as shown in Figure 20.  
Figure 20 Rebuild Status  
To pause the rebuild process  
1. In the Topology pane, scroll to the partially rebuild Virtual Disk.  
2. Press Enter to view available operation on Virtual Disk.  
3. Scroll to Pause and press Enter to pause the rebuild process.  
Note: Incomplete rebuild procedures are paused upon exiting the  
BIOS. The rebuild procedure(s) can be resumed manually upon  
re-entering the BIOS.  
UGTIS602R  
Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To pause the rebuild process  
1. In the Topology pane, scroll to the partially rebuild Virtual Disk.  
2. Press Enter to view available operation on Virtual Disk.  
3. Scroll to Resume and press Enter to resume the rebuild process.  
Note: The rebuild process is both initiated and completed in the  
BIOS. The Marvell RAID Utility (MRU), which runs in an OS  
environment, cannot be used to either initiate, pause, resume, or  
complete the rebuild process.  
Deleting Virtual Disk  
To delete a virtual disk  
1. In the Topology pane, select Virtual Disk (VD 0: Default in  
Figure 21) and press Enter.  
A menu pops-up, as shown Figure 21.  
2. Select Delete to delete the virtual disk, as shown in Figure 21.  
3. Press Y to select Yes when prompted Do you want to delete this  
virtual disk?  
4. Press Y to select Yes when prompted Do you want to delete  
MBR from this virtual disk?  
Figure 21 Delete Virtual Disk  
UGTIS602R  
Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Driver Installation  
Note: Driver can also be found and downloaded from our website at  
For Windows® XP/Server 2003  
For A New Installation  
A new installation requires a floppy disk for the driver  
installation. To make this floppy disk, copy the contents of  
the “UGT-IS602R\XP_2003_Vista_2008_7\Floppy32” folder, found  
on the driver CD, onto a blank floppy disk then follow the directions  
UGTIS602R  
Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
below.  
1. Follow Microsoft’s Windows installation procedure.  
2. At the Windows Setup screen, press F6 to install the driver.  
3. When prompted, press S to specify the location of the driver.  
4. Insert the floppy disk, then press Enter.  
5. Scroll to Marvell shared library (install first) using the arrow  
keys and press Enter to select.  
6. Press S again to select the second device.  
7. Scroll to Marvell 91xx SATA Controller 32bit Driver and press  
Enter to select.  
8. Press Enter to complete the installation of drivers.  
9. Continue with the Windows OS installation.  
10. And there is an additional device Marvell 91xx Config SCSI  
Processor Device is detected when Windows starts for the first  
time.  
11. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
12. At the Windows desktop, click Start, then Run.  
13. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
UGTIS602R  
Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OK. (Change D:\ to match your CD-ROM drive letter)  
14. Follow the on-screen instructions to complete the installation.  
15. After successful installation, the device is listed in the Device  
Manager as Marvell 91xx Config Device (under System Device)  
For An Existing Installation  
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
2. At the Windows desktop, click Start, then Run.  
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
OK. (Change D:\ to match your CD-ROM drive letter)  
4. Follow the on-screen instructions to complete the installation.  
5. Restart Windows to complete the installation.  
For Windows® XP-x64/Server 2003-x64  
For A New Installation  
A new installation requires a floppy disk for the driver  
installation. To make this floppy disk, copy the contents of  
the “UGT-IS602R\XP_2003_Vista_2008_7\Floppy64” folder, found  
on the driver CD, onto a blank floppy disk then follow the directions  
UGTIS602R  
Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
below.  
1. Follow Microsoft’s Windows installation procedure.  
2. At the Windows Setup screen, press F6 to install the driver.  
3. When prompted, press S to specify the location of the driver.  
4. Insert the floppy disk, then press Enter.  
5. Scroll to Marvell shared library (install first) using the arrow  
keys and press Enter to select.  
6. Press S again to select the second device.  
7. Scroll to Marvell 91xx SATA Controller 64bit Driver and press  
Enter to select.  
8. Press Enter to complete the installation of drivers.  
9. Continue with Windows OS installation.  
10. And there is an additional device Marvell 91xx Config SCSI  
Processor Device is detected when Windows starts for the first  
time.  
11. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
12. At the Windows desktop, click Start, then Run.  
13. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
UGTIS602R  
Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OK. (Change D:\ to match your CD-ROM drive letter)  
14. Follow the on-screen instructions to complete the installation.  
15. After successful installation, the device is listed in the Device  
Manager as Marvell 91xx Config Device (under System Device)  
For An Existing Installation  
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
2. At the Windows desktop, click Start, then Run.  
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
OK. (Change D:\ to match your CD-ROM drive letter)  
4. Follow the on-screen instructions to complete the installation.  
5. Restart Windows to complete the installation.  
For Windows® Vista/2008/7  
For A New Installation  
1. Follow Microsoft’s Windows installation procedure.  
2. At the Windows Setup screen, press Load Driver to install the  
driver.  
UGTIS602R  
Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Insert the CD driver bound with 2+1 SATA 6G & PATA PCI-E  
COMBO HOST CARD WITH RAID into your CD-ROM Drive,  
please select Marvell 91xx SATA 6G Controller  
(D:\UGT-IS602R\XP_2003_Vista_2008_7\Floppy32\mv91xx.inf),  
then press Next. (Change D:\ to match your CD-ROM drive  
letter)  
4. Continue with Windows OS installation.  
5. And there is an additional device Marvell 91xx Config SCSI  
Processor Device is detected when Windows starts for the first  
time.  
6. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
7. At the Windows desktop, click Start, then Run.  
8. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
OK. (Change D:\ to match your CD-ROM drive letter)  
9. Follow the on-screen instructions to complete the installation.  
10. After successful installation, the device is listed in the Device  
Manager as Marvell 91xx Config Device (under System Device)  
UGTIS602R  
Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For An Existing Installation  
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
2. At the Windows desktop, click Start, then Run.  
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
OK. (Change D:\ to match your CD-ROM drive letter)  
4. Follow the on-screen instructions to complete the installation.  
5. Restart Windows to complete the installation.  
For Windows® Vista-x64/2008-x64/7-x64  
For A New Installation  
1. Follow Microsoft’s Windows installation procedure.  
2. At the Windows Setup screen, press Load Driver to install the  
RAID driver.  
3. Insert the CD driver bound with2+1 SATA 6G & PATA PCI-E  
COMBO HOST CARD WITH RAID into your CD-ROM Drive,  
please select Marvell 91xx SATA 6G Controller  
(D:\UGT-IS602R\XP_2003_Vista_2008_7\Floppy64\mv91xx.inf),  
then press Next. (Change D:\ to match your CD-ROM drive  
UGTIS602R  
Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
letter)  
4. Continue with Windows OS installation.  
5. And there is an additional device Marvell 91xx Config SCSI  
Processor Device is detected when Windows starts for the first  
time.  
6. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
7. At the Windows desktop, click Start, then Run.  
8. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
OK. (Change D:\ to match your CD-ROM drive letter)  
9. Follow the on-screen instructions to complete the installation.  
10. After successful installation, the device is listed in the Device  
Manager as Marvell 91xx Config Device (under System Device)  
For An Existing Installation  
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA  
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM  
Drive.  
2. At the Windows desktop, click Start, then Run.  
UGTIS602R  
Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click  
OK. (Change D:\ to  
match your CD-ROM drive letter)  
4. Follow the on-screen instructions to complete the installation.  
5. Restart Windows to complete the installation.  
To Verify Driver Installation  
1. Right click My Computer and click Manage.  
2. Select Device Manager.  
3. Look for the following:  
Windows® 2000/XP/2003: Double click SCSI and RAID  
Controller:  
-Marvell 91xx SATA 6G Controller should be displayed  
Windows® Vista/2008/7: Double click Storage controllers:  
- Marvell 91xx SATA 6G Controller should be displayed  
Marvell RAID Utility (MRU)  
The MRU System Tray application is available on Windows OS and  
appears as an icon in the system tray. Clicking this icon launches the  
MRU in your default browser.  
UGTIS602R  
Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UGTIS602R  
Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH  
RAID comes with a 1 year limited warranty(90 day parts). If your unit  
becomes defective within that time frame, please go to  
www.vantecusa.com for information on how to receive warranty  
exchange or repair. Cosmetic defects and missing parts are not covered  
under this warranty. Please check the contents of the unit to make sure  
you received all parts. Also, check for any cosmetic flaws. If any parts  
are missing or if there are cosmetic defects, please contact the retailer  
from which you purchased the unit immediately and ask for a  
replacement.  
Vantec Thermal Technologies  
43951 Boscell Rd. Fremont, CA 94538  
Tel: 510-668-0368 fax: 510-668-0367  
UGTIS602R  
Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Targus Webcam AVC0102 User Manual
Telex Headphones Aviation Headsets User Manual
Thecus Technology Computer Drive N299 User Manual
THORENS Turntable TD158 User Manual
Tivoli Audio Portable Radio IPAL User Manual
Toastmaster Can Opener TCO2 User Manual
Topcom Automobile Accessories MM 1000 User Manual
Top Innovations Vacuum Cleaner CF 980 User Manual
Tripp Lite Network Cables F009 006 User Manual
Vantec Power Supply VAN 350N User Manual