2+1 SATA 6G & PATA PCI-E
COMBO HOST CARD WITH RAID
User Manual
Model: UGT-IS602R
All brand names and trademarks are properties of their respective owners.
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Model:
UGT-IS602R
Bus interface: PCI-Express 2.0 x 1
Ports:
2 x Internal SATA 6G ports (Backward compatible
with SATA 3.0Gbps & 1.5Gbps)
1 x Internal IDE/PATA port
Dimension:
119 x 90 x 18mm
OS Support:
Windows® XP/2003/Vista/2008/7 (32/64 bit)
System Requirements
z
Windows® XP/2003/Vista/2008/7 (32/64 bit)
z
Computer with one available PCI-e slot
(CD-Rom Drive May Be Needed For Drivers)
Package Contents
z
1 x 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH
RAID
z
z
z
1 x Driver CD
1 x User’s Manual
1 x IDE/PATA Cable
UGT‐IS602R
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
z
2 x SATA Data Cable
Layout
Before Installing the Vantec 2+1 SATA 6G & PATA PCI-E COMBO
HOST CARD WITH RAID, please see the photo below highlighting
the available SATA6G, IDE/PATA ports of the card.
P1 & P2: SATA6G Ports
P3: IDE/PATA Port
UGT‐IS602R
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
1. Turn off the power to your computer.
2. Unplug the power cord and remove your computer’s cover.
3. Remove the slot bracket from an available PCIe slot.
4. To install the board, carefully align the card’s bus connector with
the selected PCIe slot on the motherboard. Push the board down
firmly.
5. Attach your internal devices to the 2+1 SATA 6G & PATA PCI-E
COMBO HOST CARD WITH RAID.
6. Replace the slot bracket’s holding screw to secure the card.
7. Replace the computer cover and reconnect the power cord.
Creating and Managing Virtual Disks
Creating Virtual Disks
This section describes the produce for creating virtual disks using the
BIOS Configuration Wizard.
To create a virtual disk
1. In the Topology pane, scroll to HBA0: Marvell 0 and press Enter
to select. A menu pops-up, as shown in Figure 1.
Select Configuration Wizard and press Enter to begin creating
UGT‐IS602R
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
the virtual disk.
Figure 1 Configuration Wizard
2. Press Space to select/unselect a disk, as shown in Figure 2. Use
the arrow keys to scroll the list of free disks.
Figure 2 Select Free Disks
UGT‐IS602R
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD
WITH RAID supports the creation of RAID 0 and RAID 1 virtual
disks comprising of exactly two SATA physical disks. PATA
physical disks cannot be used to create RAID virtual disks.
3. After selecting the required disks, press Enter to continue, as
shown in Figure 3.
Figure 3 Confirm Disk Selection
UGT‐IS602R
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Create Virtual Disk by configuring its setting in the Information
pane, as shown in Figure 4.
The controls for making selection are listed in the Help pane
when an available setting is highlighted.
Figure 4 Configure Virtual Disk
UGT‐IS602R
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Max size (MB) and Disk ID are properties of the virtual
disk that cannot be edited. Max size (MB) in the size of the RAID
virtual disk as determined by the selected RAID Level. Disk ID
lists the IDs of the physical disks comprising the virtual disk.
5. RAID Level, as shown in Figure 4, is highlighted when the
Create Virtual Disk screen is presented. Press Enter to select a
RAID Level. A menu pops-up, as shown in Figure 5, and lists
available RAID levels.
6. Scroll the list, as shown in Figure 5, and press Enter to select a
RAID Level (RAID 0, RAID 1).
Figure 5 RAID Level
UGT‐IS602R
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: The default Level is RAID 0.
7. Scroll to Stripe Size and press Enter to select.
A menu pops-up, as shown in Figure 6, and lists available stripe
sizes for the selected RAID level.
8. Scroll the list, as shown in Figure 6, and press Enter to select
Stripe Size (32K, 64K)
Figure 6 Stripe Size
UGT‐IS602R
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: The default size is 64 KB.
9. Scroll to Gigabyte Rounding and press Enter to select.
A menu pops-up, as shown in Figure 7, and lists available stripe
sizes for the selected RAID level.
10. Scroll the list, as shown in Figure 7, and press Enter to select
Gigabyte Rounding (None, 1G, 10G)
Figure 7 Gigabyte Rounding
UGT‐IS602R
Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: The default setting for Gigabyte Rounding is 1G.
11. Scroll to Quick Init and press Enter to enable to disable quick
initialization of the virtual disk.
A menu pops-up, as shown in Figure 8, and lists available options
for quick initialization of the virtual disk.
12. Scroll the list, as shown in Figure 8, and press Enter to select
Quick Init (Yes, No).
Figure 8 Quick Init
UGT‐IS602R
Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: The default setting for Quick Init is Yes.
13. Scroll to VD Name and the Default name is cleared for a new
name, as shown in Figure 9.
Type a new name and press Enter to confirm the selection.
Figure 9 VD Name
UGT‐IS602R
Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
14. After configuring the virtual disk, scroll to Next, as shown in
Figure 10.
Press Enter to create the virtual disk.
Figure 10 Create Virtual Disk
UGT‐IS602R
Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
15. Please Y to select Yes, as shown in Figure 11, to confirm the
creation of the virtual disk. The virtual disk is now listed in the
Topology pane, as shown in Figure 12.
Figure 11 Create Virtual Disk Confirmation
UGT‐IS602R
Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 12 Virtual Disk in Topology Pane
UGT‐IS602R
Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Managing Virtual Disks
This section contains the following topics:
z
z
z
z
Viewing Properties of Virtual Disk
Erasing RAID Configuration Data
Rebuilding Virtual Disk
Deleting Virtual Disk
Viewing Properties of Virtual Disk
To view the properties of a virtual disk, scroll to the Virtual Disk (VD
0: Default in Figure 13) in the Topology pane. The properties of the
virtual disk are displayed in the Information pane when VD 0:
Default is highlighted, as shown in Figure 13.
Figure 13 Virtual Disk Properties: Functional VD
UGT‐IS602R
Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Erasing RAID Configuration Data
Note: The RAID controller stores RAID configuration data on all
physical disks that are part of a virtual disk. RAID configuration data
must be erased on the physical disk before it can be used with another
virtual disk.
1. In the Topology pane, select Physical Disk (VD 0: Default > PD
0: ST3750330MS in Figure 14) and press Enter.
A menu pops-up, as shown Figure 14.
2. Select Delete to delete the virtual disk, as shown in Figure 14.
3. Select Yes when prompted to confirm the erase operation.
UGT‐IS602R
Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 14 Erase RAID Configuration Data
Rebuilding Virtual Disk
Note: The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD
WITH RAID BIOS supports manual rebuilding of RAID 1 virtual
disks. The rebuild process is both initiated and complete in the BIOS.
The Marvell RAID Utility (MRU), which runs in an OS environment,
cannot be used to either initiate, resume, or complete the rebuild
process. Spare physical disks are not supported.
To manually rebuild a RAID 1 virtual disk
1. When a virtual disk is degraded, the Status of a virtual disk is
UGT‐IS602R
Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
changed from Functional to Degrade, as shown in Figure 15.
Figure 15 Virtual Disk Properties: Degrade VD
2. Replace the faulty physical disk with an identical physical disk.
Note: If an identical disk is unavailable, use a replacement
physical disk or larger size or one with a slightly smaller size as
determined the Gigabyte Rounding setting for the virtual disk.
The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH
RAID detects the new physical disk and lists the device under
Free Physical Disks in the Topology pane, as shown in Figure 16.
Figure 16 Replace Physical Disk
UGT‐IS602R
Page 20
Download from Www.Somanuals.com. All Manuals Search And Download.
3. In the Topology pane, scroll to Virtual Disks (VD 0: New_VD in
Figure 17), and press Enter to select.
A menu pops-up, as shown in Figure 17
Scroll to Rebuild and press Enter to configure the rebuild
process.
Figure 17 Rebuild Virtual Disk
UGT‐IS602R
Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Scroll through the list of free disk, as shown Figure 18, and press
Space to select or unselect a replacement physical disk.
Press Enter to continue.
Figure 18 Select Replacement Disk
UGT‐IS602R
Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press Y to select Yes, as shown in Figure 19, when prompted to
confirm the rebuild process.
Figure 19 Confirm Rebuild Virtual Disk
UGT‐IS602R
Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
6. The status of the Rebuild process is reflected in the properties of
the virtual disk, as shown in Figure 20.
Figure 20 Rebuild Status
To pause the rebuild process
1. In the Topology pane, scroll to the partially rebuild Virtual Disk.
2. Press Enter to view available operation on Virtual Disk.
3. Scroll to Pause and press Enter to pause the rebuild process.
Note: Incomplete rebuild procedures are paused upon exiting the
BIOS. The rebuild procedure(s) can be resumed manually upon
re-entering the BIOS.
UGT‐IS602R
Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
To pause the rebuild process
1. In the Topology pane, scroll to the partially rebuild Virtual Disk.
2. Press Enter to view available operation on Virtual Disk.
3. Scroll to Resume and press Enter to resume the rebuild process.
Note: The rebuild process is both initiated and completed in the
BIOS. The Marvell RAID Utility (MRU), which runs in an OS
environment, cannot be used to either initiate, pause, resume, or
complete the rebuild process.
Deleting Virtual Disk
To delete a virtual disk
1. In the Topology pane, select Virtual Disk (VD 0: Default in
Figure 21) and press Enter.
A menu pops-up, as shown Figure 21.
2. Select Delete to delete the virtual disk, as shown in Figure 21.
3. Press Y to select Yes when prompted Do you want to delete this
virtual disk?
4. Press Y to select Yes when prompted Do you want to delete
MBR from this virtual disk?
Figure 21 Delete Virtual Disk
UGT‐IS602R
Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Driver Installation
Note: Driver can also be found and downloaded from our website at
For Windows® XP/Server 2003
For A New Installation
A new installation requires a floppy disk for the driver
installation. To make this floppy disk, copy the contents of
the “UGT-IS602R\XP_2003_Vista_2008_7\Floppy32” folder, found
on the driver CD, onto a blank floppy disk then follow the directions
UGT‐IS602R
Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
below.
1. Follow Microsoft’s Windows installation procedure.
2. At the Windows Setup screen, press F6 to install the driver.
3. When prompted, press S to specify the location of the driver.
4. Insert the floppy disk, then press Enter.
5. Scroll to Marvell shared library (install first) using the arrow
keys and press Enter to select.
6. Press S again to select the second device.
7. Scroll to Marvell 91xx SATA Controller 32bit Driver and press
Enter to select.
8. Press Enter to complete the installation of drivers.
9. Continue with the Windows OS installation.
10. And there is an additional device Marvell 91xx Config SCSI
Processor Device is detected when Windows starts for the first
time.
11. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
12. At the Windows desktop, click Start, then Run.
13. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
UGT‐IS602R
Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
OK. (Change D:\ to match your CD-ROM drive letter)
14. Follow the on-screen instructions to complete the installation.
15. After successful installation, the device is listed in the Device
Manager as Marvell 91xx Config Device (under System Device)
For An Existing Installation
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
2. At the Windows desktop, click Start, then Run.
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
OK. (Change D:\ to match your CD-ROM drive letter)
4. Follow the on-screen instructions to complete the installation.
5. Restart Windows to complete the installation.
For Windows® XP-x64/Server 2003-x64
For A New Installation
A new installation requires a floppy disk for the driver
installation. To make this floppy disk, copy the contents of
the “UGT-IS602R\XP_2003_Vista_2008_7\Floppy64” folder, found
on the driver CD, onto a blank floppy disk then follow the directions
UGT‐IS602R
Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
below.
1. Follow Microsoft’s Windows installation procedure.
2. At the Windows Setup screen, press F6 to install the driver.
3. When prompted, press S to specify the location of the driver.
4. Insert the floppy disk, then press Enter.
5. Scroll to Marvell shared library (install first) using the arrow
keys and press Enter to select.
6. Press S again to select the second device.
7. Scroll to Marvell 91xx SATA Controller 64bit Driver and press
Enter to select.
8. Press Enter to complete the installation of drivers.
9. Continue with Windows OS installation.
10. And there is an additional device Marvell 91xx Config SCSI
Processor Device is detected when Windows starts for the first
time.
11. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
12. At the Windows desktop, click Start, then Run.
13. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
UGT‐IS602R
Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
OK. (Change D:\ to match your CD-ROM drive letter)
14. Follow the on-screen instructions to complete the installation.
15. After successful installation, the device is listed in the Device
Manager as Marvell 91xx Config Device (under System Device)
For An Existing Installation
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
2. At the Windows desktop, click Start, then Run.
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
OK. (Change D:\ to match your CD-ROM drive letter)
4. Follow the on-screen instructions to complete the installation.
5. Restart Windows to complete the installation.
For Windows® Vista/2008/7
For A New Installation
1. Follow Microsoft’s Windows installation procedure.
2. At the Windows Setup screen, press Load Driver to install the
driver.
UGT‐IS602R
Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Insert the CD driver bound with 2+1 SATA 6G & PATA PCI-E
COMBO HOST CARD WITH RAID into your CD-ROM Drive,
please select Marvell 91xx SATA 6G Controller
(D:\UGT-IS602R\XP_2003_Vista_2008_7\Floppy32\mv91xx.inf),
then press Next. (Change D:\ to match your CD-ROM drive
letter)
4. Continue with Windows OS installation.
5. And there is an additional device Marvell 91xx Config SCSI
Processor Device is detected when Windows starts for the first
time.
6. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
7. At the Windows desktop, click Start, then Run.
8. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
OK. (Change D:\ to match your CD-ROM drive letter)
9. Follow the on-screen instructions to complete the installation.
10. After successful installation, the device is listed in the Device
Manager as Marvell 91xx Config Device (under System Device)
UGT‐IS602R
Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
For An Existing Installation
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
2. At the Windows desktop, click Start, then Run.
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
OK. (Change D:\ to match your CD-ROM drive letter)
4. Follow the on-screen instructions to complete the installation.
5. Restart Windows to complete the installation.
For Windows® Vista-x64/2008-x64/7-x64
For A New Installation
1. Follow Microsoft’s Windows installation procedure.
2. At the Windows Setup screen, press Load Driver to install the
RAID driver.
3. Insert the CD driver bound with2+1 SATA 6G & PATA PCI-E
COMBO HOST CARD WITH RAID into your CD-ROM Drive,
please select Marvell 91xx SATA 6G Controller
(D:\UGT-IS602R\XP_2003_Vista_2008_7\Floppy64\mv91xx.inf),
then press Next. (Change D:\ to match your CD-ROM drive
UGT‐IS602R
Page 32
Download from Www.Somanuals.com. All Manuals Search And Download.
letter)
4. Continue with Windows OS installation.
5. And there is an additional device Marvell 91xx Config SCSI
Processor Device is detected when Windows starts for the first
time.
6. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
7. At the Windows desktop, click Start, then Run.
8. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
OK. (Change D:\ to match your CD-ROM drive letter)
9. Follow the on-screen instructions to complete the installation.
10. After successful installation, the device is listed in the Device
Manager as Marvell 91xx Config Device (under System Device)
For An Existing Installation
1. Please insert the CD driver bound with 2+1 SATA 6G & PATA
PCI-E COMBO HOST CARD WITH RAID into your CD-ROM
Drive.
2. At the Windows desktop, click Start, then Run.
UGT‐IS602R
Page 33
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe, click
OK. (Change D:\ to
match your CD-ROM drive letter)
4. Follow the on-screen instructions to complete the installation.
5. Restart Windows to complete the installation.
To Verify Driver Installation
1. Right click My Computer and click Manage.
2. Select Device Manager.
3. Look for the following:
Windows® 2000/XP/2003: Double click SCSI and RAID
Controller:
-Marvell 91xx SATA 6G Controller should be displayed
Windows® Vista/2008/7: Double click Storage controllers:
- Marvell 91xx SATA 6G Controller should be displayed
Marvell RAID Utility (MRU)
The MRU System Tray application is available on Windows OS and
appears as an icon in the system tray. Clicking this icon launches the
MRU in your default browser.
UGT‐IS602R
Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
UGT‐IS602R
Page 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH
RAID comes with a 1 year limited warranty(90 day parts). If your unit
becomes defective within that time frame, please go to
www.vantecusa.com for information on how to receive warranty
exchange or repair. Cosmetic defects and missing parts are not covered
under this warranty. Please check the contents of the unit to make sure
you received all parts. Also, check for any cosmetic flaws. If any parts
are missing or if there are cosmetic defects, please contact the retailer
from which you purchased the unit immediately and ask for a
replacement.
Vantec Thermal Technologies
43951 Boscell Rd. Fremont, CA 94538
Tel: 510-668-0368 fax: 510-668-0367
UGT‐IS602R
Page 36
Download from Www.Somanuals.com. All Manuals Search And Download.
|