Issue 9
45 OHM TALKBACK INTERIOR SPEAKERS
`
V-1060A
V-1060B
V-1061-W, V-1061-BK
V-1062A, V-1064A. V-1066A
V-1063A, V-1065A, V-1067A
INTRODUCTION
Dimensions/Weight
These instructions contain the specifications and
guidelines necessary to install, operate and maintain
Valcom 45 Ohm Talkback Interior Speaker
Assemblies.
8” Ceiling Speakers:
V-1060A talkback speaker
V-1060B talkback speaker with LED
13.00" Diameter x 2.50" D
(33.02cm Diameter x 6.35cm D)
2.5 lbs. (1.13 kg)
Wall Speakers:
The 45 Ohm Talkback Interior Speaker Assemblies
are for use with the Valcom "handsfree" talkback
page control units and are for interior use only.
V-1061-BK black vinyl w/black cloth grille
V-1061-W white vinyl w/white cloth grille
9.60" H x 11.50" W x 4.20" D
(24.38cm H x 29.21cm W x 10.67cm D)
4 lbs. (1.81 kg)
V-1062A wood grain w/light brown open weave grille
V-1063A wood grain w/dark brown cloth grille
10.60" H x 9.70" W x 5.20" D
(26.92cm H x 24.64cm W x 13.21cm D)
4.0 lbs. (1.81 kg)
SPECIFICATIONS
Features
45 Ohm Impedance
8 Inch Speaker
Easy Hook-up (2 connections using house cable
or station wire)
LED indicator (V-1060B only)
1
947065
Download from Www.Somanuals.com. All Manuals Search And Download.
CORNER SPEAKERS: After making the
required connections to the speaker, use
appropriate hardware such as an 8d finishing
nail and hang the speaker in the corner. Typical
mounting height would be 8 feet.
INSTALLATION
Connections
Two conductor (four conductor for V-1060B
only) twisted wire is required for the 45 Ohm
talkback speakers. Standard 22 or 24 gauge
station wire is acceptable. Shielded wire is not
required or recommended.
CORRIDOR SPEAKERS: Unscrew mounting
bracket and baffle from speaker assembly.
Using appropriate hardware, mount the bracket
to the wall. After making the required
connections, reattach the baffle to the speaker
and the speaker to the mounting bracket.
Connections are as follows:
Speaker out from page control to speaker tip
Speaker common to speaker ring
For 1060B only:
Switched -24VDC to -24VDC (LED)
Power Supply ground to GND (LED)
TECHNICAL ASSISTANCE
When trouble is reported, verify there are no
broken connections. Troubleshooting
assistance is available from the factory.
Call (540) 563-2000 and press 1 for Technical
Support, or visit our website at
Mounting
CEILING SPEAKERS: Cut an 8.5" diameter
hole in ceiling tile. After connections have been
made to the speaker, attach speaker to ceiling
tile using the mounting hardware provided.
NOTE: Where extra speaker support is needed,
a V-9916 or V-9916M Valcom Bridge and
Backbox should be used.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating company
name, address, phone number, contact person
WALL SPEAKERS: After making the required
connections, fasten a suitable mounting screw
(#10 sheet metal screw or similar) to the wall at
the desired location for mounting of the speaker.
Hang the speaker on the screw using the
keyhole on the speaker bracket.
and the nature of the problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
TROUBLESHOOTING CHART
SYMPTOMS
ACTIONS
No sound in page mode
Check tip and ring for audio at speaker.
Check tip and ring for audio at control unit.
Check volume controls at page control.
Low sound in page mode
Poor listening in talkback mode
Check talkback volume control at page control. Set control where audio is
clearly audible.
No LED indication (on V-1060B)
Check presence and polarity of LED input signal.
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one
year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device
within the warranty period, provided that:
1.
2.
3.
inspection by Valcom, Inc. indicates the validity of the claim;
the defect is not the result of damage, misuse or negligence after the original shipment;
the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service charge plus parts
and labor will be applied to units defaced or physically damaged);
4.
5.
freight charges for the return of products to Valcom are prepaid;
all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (Major repairs will be subject to
additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or
use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
Phone: (540) 563-2000
FAX: (540) 362-9800