Unified Brands Ventilation Hood EcoArch User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
by the heated updraft from the cooking process.  
Exclusive Aerodynamic Arch  
The arch dramatically reduces the amount of turbulence by  
directing contaminated heated air into the front location exhaust  
plenum. In contrast to traditional exhaust hoods, testing indicates  
that about 70% of the heated air is immediately exhausted out of  
the reservoir area. The remaining air is directed back by the arch  
towards the rear of the hood with little or no turbulence until it  
During the cooking process, contaminated heated air rises at  
various rates of speed up into the hood reservoir. A traditional  
exhaust hood allows up to 60% of the heated air to hit the  
perpendicular surface at the top of the hood creating an  
enormous amount of turbulence within the reservoir. Our  
EcoArch Ventilation System  
Contaminated air is directed to the exhaust slot  
through the arch top, minimizing turbulence  
Traditional Ventilation System  
Contaminated air is trapped within the hood and  
creates turbulence until it can be exhausted.  
SAMPLE ENERGY SAVINGS  
Options  
150 cfm/ft (EcoArch) vs. 250 cfm/ft (traditional unit)  
• PBB ceiling mounted perforated make-up air plenum box  
(shown above)  
12’Hood, 400°F, Gas & Electric, Based on 2006 Utility Rates  
Annual Annual Total Energy Savings  
Location  
cfm/ft  
• Fire System end mounted enclosure cabinet  
• Ceiling enclosure panels  
Gas  
Electric  
$1364  
$828  
Annually  
$6789  
%
New York, NY  
New York, NY  
Total Savings  
Atlanta, GA  
250  
150  
$5425  
$3255  
$2170  
$3728  
$2237  
$1491  
• Hanging Rods  
$4083  
• Pre-piped wet chemical fire extinguishing system  
• Wall flashing  
$536  
$943  
$2706  
$4671  
40%  
250  
150  
• Hood mount fan on/off buttons  
Atlanta, GA  
$571  
$2808  
Total Savings  
$371  
$1863  
40%  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UTILITY  
DISTRIBUTION  
SYSTEMS  
CONVEYOR  
SYSTEMS  
VENTILATION  
SYSTEMS  
888-994-7636 • avtecind.com  
FOODSERVICE EQUIPMENT SOLUTIONS  
Information contained in this document is known to be current and accurate at the time of printing.  
Unified Brands recommends referencing our product line websites for the most updated product information and specifications.  
EA 04/07 (3m)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson MP3 Player PDP2814 User Manual
Teledyne Photo Scanner 703E User Manual
Transition Networks Switch CSEFE10XX 10X User Manual
Turbosound Speaker TCS 122 XXDP User Manual
Verilux Home Safety Product VB03 User Manual
Vidikron Computer Monitor VP 42 User Manual
Viking Ventilation Hood DIV880 User Manual
VocoPro Microphone UHF 5900 User Manual
WatchGuard Technologies Washer XTM 5 Series User Manual
Wayne Dalton Medical Alarms 255081 User Manual