The Power Fogger Industrial is a Microprocessor Controlled, Water Based Fog generating system.  
Microprocessor Control  
The PFI features dual microprocessor control. From temperature regulation to taper back flow control, all of the  
functions are monitored and processed by the two on-board processors.  
Water Base Fog Technology  
Water Base Fog technology is achieved by pumping a glycol/water mixture through a heat exchanger. This will  
vaporize the fluid as it passes through the hot unit. The vaporization of the fluid forces the hot mixture through  
the output nozzle. When mixed with ambient air, it forms an opaque aerosol (fog). The fog is made up of tiny  
droplets that form around small particles in the air. The suspended droplets refract the light, allowing the fog to  
take on the color of the light illuminating it.  
Warning  
Important Safety Instructions:  
1. Do not touch, place hands or expose skin within 20” (50 cm) of the discharge nozzle.  
2. Do not remove the outer case.  
3. Persons suffering from asthma or allergenic sensitivity may experience irritation, discomfort or allergic  
symptoms when exposed to fog effects.  
4. Ensure that this unit is grounded at all times. Failure to do so may result in serious injury.  
5. Use Ultratec Special Effects fluid ONLY.  
Safety Precautions  
1. Ensure that any operation of the machine is supervised by suitably trained and authorized personnel.  
2. Do not modify the machine or use a machine which has been damaged in any way.  
3. Allow sufficient air circulation around the machine at all times.  
4. Protect the machine from direct weather effects and wet locations.  
5. Only use fluids manufactured by Ultratec Special Effects.  
6. Do not continue to produce fog when visibility is reduced to 20” 50cm or below.  
7. Avoid directing fog output continuously at people, structures or objects within close proximity of the discharge  
nozzle.  
8. Ensure that adequate exhausting arrangements are available in the event of an emergency.  
9. Do not place hands or exposed skin within the first 20” (50 cm) of the discharge nozzle at any time during fog  
production.  
10.Fog effects can trigger smoke alarms and detectors. Please take suitable precautions to prevent false alarms.  
11.Ensure sufficient air exchange vs. CO2 released.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PFI Technical Specifications  
Model:  
PFI/PFI-9D  
Part Number:  
PFI  
CLF 4450 / 120 volt  
CLF 4451 / 220-240 volt  
PFI-9D  
CLF 4460 / 110 volt  
CLF 4461 / 220-240 volt  
Power Rating:  
Fluid:  
120 Volt A.C. 50/60 Hz. 13 Amps.  
240 Volt A.C. 50/60 Hz. 6.5 Amps.  
Water Base Fog Fluid (Use only Ultratec Fluid)  
PFI Technical Drawings  
Power Fogger Industrial  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Fogger Industrial 9D  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
LSG w/ PFI Technical Drawings  
LSG PFI System on a Cart  
28.02  
22  
36  
20  
32.2  
29.6  
24  
LSG PFI System in a Roadcase  
23.25  
39.5  
28.75  
34.5  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Procedure  
1. The fog machine must be connected to a grounded supply of at least 15 amps free of any interference.  
2. Open a 20 Litre (5 Gallon) container of Ultratec Special Effects fog fluid and insert the fluid pickup tube into the  
spout of the fluid container.  
3. Connect the Remote Handset into the rear panel connector located on the rear panel. (When using DMX the  
Remote is not required).  
4. Activate the Power switch located on the rear panel. The Power switch and Handset indicator will illuminate to  
indicate the presence of power. If the Handset indicator does not illuminate, ensure the connector is properly  
inserted.  
5. The Handset indicator will begin to flash slowly, but will speed up  
when the fog machine is ready to operate. After approximately 9  
minutes, the fog machine will be fully heated and is ready for full  
output; the indicator will be on solid.  
6. It may be necessary to prime fluid into the system to expel any  
air. The Variflow control on the remote handset should be set to  
the full position. A dry hose can take between 45-60 seconds to  
prime. This only needs to be done if the unit was left to run dry.  
7. To adjust the depth of the hose, simply loosen Nut ‘A’ and slide  
up or down the hose and retighten. Be careful not to pinch off  
the flow of fluid.  
NOTE: In order to prime the fog machine, the Handset Indicator must be a solid red.  
Operating Procedure w/ Air Option  
A) Mount the Regulator Bracket to a wall or other secure  
location.  
B
A
D
A
B) Attach the female coupler to the male coupler of the  
Power Fog Industrial w/ Air Option or Power Fog Industrial  
9D w/ Air Option.  
C
C) Attach the air hose to the male coupler of the mounted  
regulator.  
D) Adjust for the desired air pressure (typically 25-50 psi).  
A
A
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Procedure  
LSG MK II High Pressure w/ 20 & 50lbs Cylinders  
The Operation Procedures outlined in this section, refer to Figure A and Figure B on Page 9 and 10.  
1. Place the fog machines output nozzle firmly against the center of the foam ring, sealing it to the input port of the  
LSG MK II.  
Tech Tip: Proper alignment can be observed by shining a flashlight into the 10” exit port of the LSG MK II and noting  
the foggers output nozzle is centered on the LSG MK II input port.  
2. Connect the blue Twist Lock connector from the LSG MK II into the controlling power source (i.e. control port on  
the rear panel of the Power Fog Family of Ultratec Special Effects Foggers). This port can be controlled via DMX, the  
Timer/ Duration Remote or the Show Control Remote.  
Note: Starting the flow of CO2 before the fog allows the liquid CO2 to purge the gas CO2 from the lines. The Liquid  
CO2 is required for correct operation. The rule of thumb formula for calculating the purge time is 1 second for every 3  
feet of hose. As the unused liquid sits in the hose, it absorbs heat and converts to its gaseous state.  
3. Use Molecular Fog Fluid and adjust the flow rate to the desired fog output level. Excessive fog flow will not cool  
sufficiently allowing the fog to rise off of the floor.  
Warning: Always secure all cylinders to prevent tipping hazards.  
4. An LSG MK II High Pressure requires high pressure CO2 cylinders. These are normally available in 20 & 50lb sizes. It  
is recommended that cylinders equipped with liquid siphon tubes be used. If using 20lb cylinders without the siphon  
tube, invert the bottles and place them in bottle racks.  
Warning: We do not recommend inverting the 50 lbs cylinders. Use 50 lb cylinders equipped with liquid siphon tubes.  
5. The CO2 supply hose is connected to the CO2 cylinder. Increased performance is available by connecting two or  
more cylinders in parallel. Exercise safe handling and connection of the tank as indicated by the gas supplier. A  
sealing washer is necessary to prevent leaks between the hose and valve and is available from your gas supplier.  
6. Tighten the CO2 hose-fitting snug with the appropriate wrench.  
Warning: Wear eye protection and gloves to protect against cold and pressure hazards  
7. Open valve(s) slowly counter-clockwise until flow can be heard. Verify the lines have no leaks before opening the  
valve(s) fully.  
8. When the fog machine is up to operating temperature, activate the control to start the CO2 for the desired purge  
and pre-chill time. Purging of the CO2 gas can be noted by the change in the sound of flow. It is often desirable to  
pre-chill the chamber and long runs of ductwork like a Fog Curtain. Now add fog to create the thick, white rolling  
blanket that hugs the floor. On the Power Fog Family of Ultratec Special Effects Foggers, the CO2 is triggered by  
DMX (DMX channel + 1) or by one of the remotes. To control using the remote, the DMX address is selected as 555.  
This allows the Duration knob (turned up over 1/2 way) of the Timer/ Duration Remote or the second channel of the  
Show Control Remote to trigger the LSG MK II.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Verify cool temperature output by using your hand and passing it through the fog-CO2 output noting the  
temperature.  
10.After use, turn off the valves and trigger the LSG MK II to depressurize the system before attempting to disconnect  
hoses. Note that the valves and lines may be extremely cold during operation. Prevent handling and flexing of lines  
when chilled.  
Figure A  
Liquid Carbon Dioxide  
LSG Control Signal  
Fog Fluid  
High Pressure Bottles without Siphon  
Tubes inverted to obtain liquid supply.  
20 Litre Fluid  
in a box  
Installation Model Shown Above  
Touring Model Available  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure B  
Liquid Carbon Dioxide  
LSG Control Signal  
Fog Fluid  
Liquid Siphon  
Tube  
Liquid Carbon  
Dioxide  
High Pressure Bottles w/  
Liquid Siphon Tube  
Installation Model Shown Above  
Touring Model Available  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Procedure  
LSG MK II Low Pressure w/ 350lbs Dewar Tank  
The Operation Procedures outlined in this section, refer to Figure C on Page 12.  
1. Place the fog machines output nozzle firmly against the center of the foam ring sealing it to the input port of the  
LSG MK II.  
Tech Tip: Proper alignment can be observed by shining a flashlight into the 10” exit port of the LSG MK II and noting  
the foggers output nozzle is centered on the LSG MK II input port.  
2. Connect the blue Twist lock connector from the LSG MK II into the controlling power source (i.e. control port on  
the rear panel of the Power Fog Family of Ultratec Special Effects Foggers). This port can be controlled via DMX, the  
Timer/ Duration Remote or the Show Control Remote.  
Note: Starting the flow of CO2 before the fog allows the liquid CO2 to purge the gas CO2 from the lines. The Liquid  
CO2 is required for correct operation. The rule of thumb formula for calculating the purge time is 1 second for every  
three feet of hose. As the liquid sits in the hose unused it absorbs heat and converts to its gas state.  
3. Use Molecular Fog Fluid and adjust the flow rate to desired fog output level. Excessive fog flow will not cool  
sufficiently allowing the fog to rise off of the floor.  
4. An LSG MK II Low requires low pressure Liquid CO tanks. These are normally available in a 350lb size. These are  
large vacuum tanks which keep the Liquid CO2 cold. Some CO2 is consumed during storage to maintain the liquid  
at -56C. These tanks provide the best performance and price characteristics of the LSG systems. Check with your  
local gas supplier for availability as not every location may carry these tanks.  
Warning: Wear eye protection and gloves to protect against cold and pressure hazards.  
5. You must connect the supply hose to the liquid output of the liquid CO2 tank. This is usually clearly indicated on  
the Liquid CO2 Tank outputs. A sealing washer is necessary to prevent leaks and is available from your gas supplier.  
6. Tighten the CO2 supply-fitting snug with the appropriate wrench.  
7. The tank pressure is indicated on the pressure gauge and must read between 275 - 340 psi to operate the LSG  
MK II. This is achieved by opening the Pressure Builder Valve (by turning it counter clockwise) at least 1-3 hours in  
advance.  
8. Open the valve slowly counter-clockwise until flow can be heard. Verify the lines have no leaks before opening the  
valve fully.  
9. When the fog machine is up to operating temperature, activate the control to start the CO2 for the desired purge  
and pre-chill time. Purging of the CO2 gas can be noted by the change in the flow sound. It is often desirable to  
pre-chill the chamber and long runs of ductwork (i.e. Fog Curtain). Now add fog to create the thick, white rolling  
blanket that hugs the floor. On the Power Fog Family of Ultratec Special Effects Foggers, the CO2 is triggered by  
DMX (DMX channel + 1) or by one of the remotes. To control using the remote, the DMX address is selected as 555.  
This allows the Duration knob (turned up over 1/2 way) of the Timer/ Duration Remote or the second channel of the  
Show Control Remote to trigger the LSG MK II.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10.Verify cool temperature output by using your hand and passing it through the fog-CO2 output noting the  
temperature.  
11.After use, turn off the valves and trigger the LSG MK II to depressurize the system before attempting to disconnect  
the hoses. Note that the valves and lines may be extremely cold during operation. Prevent handling and flexing of  
lines when chilled.  
Figure C  
Liquid Carbon Dioxide  
LSG Control Signal  
Fog Fluid  
350lb Liquid Carbon  
Dioxide Dewar  
20 Litre Fluid  
in a box  
Installation Model Shown Above  
Touring Model Available  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Options  
Remotes - The Show Control Remote and Timer/ Duration Remote are compatible with the Power Fog Industrial,  
Power Fog Industrial w/ Air Option, Power Fog Industrial 9D and Power Fog Industrial 9D w/ Air Option. Each remote is  
sold separately.  
Jug Holder - The Power Fog Industrial 9D and Power Fog Industrial 9D w/ Air Option has  
been designed to be versatile in any setting. For ease of operation, a jug holder may be used  
to secure the fluid to the machine. The Jug Holder is sold separately.  
4” Hose Adapter - If your intention is to connect a 4” hose to the machine and direct the  
fog elsewhere, a 4” Hose Adapter (CXP 1046) is available. This adapter is compatible with the  
Power Fog Industrial, Power Fog Industrial w/ Air Option, Power Fog Industrial 9D and Power  
Fog Industrial 9D w/ Air Option.  
Optional Show Control Remote Operations  
The Show Control Remote Handset was designed to indicate operation modes. These are as follows:  
Show Control Remote LED Indicator  
Slow Flashing Light: Indicates unit is not ready to operate but still in  
heating mode, fog is not available at this point.  
Show Control  
Input  
Quick Flashing Light: Indicates unit is ready to operate but still in  
heating mode, some fog is available at this point.  
Flow Control  
Solid Light: Indicates that the unit is ready to fog at full output.  
Manual Fog  
No Light: Indicates problems; a loss of power or remote is not connected.  
On/ Off Switch  
If these fail to correct the problem, contact your local  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Closed “Dry” Contact  
Show Control  
Show Control Operation  
Show control is achieved by connecting a “Dry” or zero voltage contact to the  
show control terminals. The Power Fog Industrial requires no power to signal the  
fog, only one set of contacts that close for the entire fogging cue.  
For Show Control Operation, the DMX Address must be set on 555. Closing the  
Show Control Remote terminals with dry contacts, triggers the following machine  
functions:  
C + 1 = On/ Off w/ Variflow  
C + 2 = LSG On  
C + 3 = Air Option  
Optional Timer/ Duration Remote  
Operations  
The Timer/ Duration Remote offers Duration, Interval, Variflow and fog on/ off  
controls.  
Timer/ Duration Remote LED Indicator  
The Timer/ Duration Remote Handset was designed to  
indicate operation modes. These are as follows:  
Duration  
Interval  
Slow Flashing Light: Indicates unit is not ready to  
operate but still in heating mode, fog is not available at  
this point.  
Variflow  
Quick Flashing Light: Indicates unit is ready to operate  
but still in heating mode, some fog is available at this  
point.  
Manual Fog  
On/ Off Switch  
LED  
Solid Light: Indicates that the unit is ready to fog at full  
output.  
No Light: Indicates problems; a loss of power or remote is not connected. If these fail to correct the problem, contact  
your local Ultratec Special Effects dealer.  
Note: To operate the LSG MK II using the Timer/ Duration Remote, the DMX Address must be set on 555 and the  
Duration control set over 50%. If the Duration is set at anything less than 50%, the Switched Power Port will be off.  
The Interval Knob works in the same fashion for machines equipped with the Air Option. The Show Control Remote  
and Timer/ Duration Remote cable may be extended from the machine and operated effectively away from the Power  
Fog Industrial. The maximum recommended cable length is 225 Feet.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DMX Operation  
The Power Fog Industrial is equipped with DMX controls as a standard feature.  
1. Attach a DMX signal to the DMX IN 5 pin connector on the rear of the unit. A terminator may be required on the  
DMX OUT connector in some applications.  
2. Select a valid DMX address on the thumbwheel selector for the base address of the fogger. If an air option is present  
3 consecutive address will be required. Base DMX= fog rate controlled 0-100%, DMX+1=LSG power on above  
50%, and DMX+2= air on above 50%.  
3. Valid DMX LED is on solid if good DMX signal is present. DMX control overrides hand remotes. Slow or irregular  
flashing indicates poor DMX data. A steady flashing indicates factory test mode and DMX switches were in the 600-  
699 range at power-up. Reset switches to required address and cycle the main power switch.Recommended Fluids  
Maintenance  
Exterior  
The casing of the PFI is stainless steel with a powder paint coating. To clean simply wash with mild soap and warm  
water.  
Heat Exchanger  
Using high quality Ultratec Special Effects fluid should result in a long heat exchanger life. (See warranty policy later in  
this manual).  
Recommended Fluid  
Director’s Choice Fog Fluid: The choice of professionals. Directors Choice creates a cloud of fog with a medium hang  
time while remaining clean, white, dry, and odorless.  
Pro Beam Long Lasting Fog Fluid: With a hang time 2-3x greater than the Directors Choice Fog Fluid, the Pro Beam  
solution produces a slightly less white fog while remaining clean, dry, and odorless.  
Quick Dissipating Fog Fluid: This fast dissipating fluid is great for applications or effects that require quick dissipation  
of fog. It produces excellent steam effects that resemble nitrogen bursts and it also keeps low-lying fog from rising too  
quickly when it is used with the LSG or LSX.  
Extra Quick Dissipating Fog Fluid: Dissipates 2x the rate of Quick Dissipating Fog Fluid while maintaing similar  
characteristics.  
Molecular Fog Fluid: A faster dissipation versus the Directors Choice Fog Fluid. This thick, clean, white fog is an  
optimal solution for a dense low-lying fog effect when chilled with the LSG or LSX machines.  
Party Fog Fluid: Quality fog fluid on a budget. An excellent solution for Djs, Nightclubs, Haunted Houses etc., looking  
to enhance light beams and creating various smoke effects.  
Maxi Fog Fluid: The perfect balance between price and performance. Maxi Fog is the ideal solution for those who  
require high volume without compromise.  
Maintenance Fluid  
EZ Kleen Preventative Maintenance Fluid: Using EZ Kleen preventative maintenance fluid on a regular basis ensures  
longer life for the heat exchanger in Ultratec fog machines by reducing blockage.  
All of our Fog Fluids are water based. Damage will occur if Haze Fluid is used in the Power Fogger Industrial.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Warranty:  
All warranty is for one year parts and labour unless specified or manufacturer defect only.  
Abuse or Poor Maintenance will not be covered under warranty. Ultratec Special Effects Fluids  
must always be used. Use of any non Ultratec Special Effects Fluids will void all warranties.  
Accept no substitutions as there are no exceptions to this rule. Proof of Purchase or Proof of  
Sale must always accompany any warranty returns. An RA (return authorization) number must  
be noted on the outside of the box being returned to our facilities. Any packages without  
a clearly marked RA number will not be accepted by our receiving department. Freight on  
warranty items are freight prepaid to our facility and we will prepay freight back to your facility  
after repair by the most economical means available. Should you require the item express-  
returned, then you are responsible for any difference in freight cost.  
Return Policy:  
Return of any product must be done within 30 days of purchase. The package must be  
returned freight prepaid and the RA number clearly marked on the outside of the box.  
Minimum restocking fee is 25%. Once our facility has received the product a technical  
assessment will be completed to determine if an additional restocking fee needs to be issued.  
Only credits are issued to the dealers account. Any product not returned within 30 days is  
considered purchased.  
Warning:  
Ultratec Special Effects Inc. considers all of its product to be safe for use in the application it  
was intended. Ultratec Special Effects takes no responsibility for misuse or incorrect use. Always  
refer to the Product Manual for proper use.  
Contact Information  
Head Office  
Canadian Shipping Address  
USA Shipping Address  
(For All USA Repairs)  
Ultratec Special Effects Inc.  
640 Gadson St.  
Ultratec Special Effects Inc.  
1960 Blue Heron Drive  
London, Ontario N6H 5L9  
(For All Canadian Repairs)  
Ultratec Special Effects Inc.  
1960 Blue Heron Drive  
London, Ontario N6H 5L9  
Groveland, Florida 34736  
Direct: 519-659-7972  
Toll Free: 866-534-5557  
Fax: 519-659-7713  
Please remember to include the RA Number on all items being shipped for  
repairs.  
To get an RA Number, visit www.ultratecfx.com and click on the “Service” tab  
and then click on “Master Service Tracker or contact service at 519-951-3357 /  
866.534.5557  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam Music Mixer IF AE8HR User Manual
Technicolor Thomson Network Card 8900NET User Manual
Toshiba Air Conditioner RAS 10SA E User Manual
Toshiba Computer Drive HDD2J93 User Manual
Trane Air Conditioner TSD User Manual
Transcend Information MP3 Player TS512MMP810EU User Manual
Uniden Flat Panel Television TL27TX1 AW User Manual
ViewSonic Computer Monitor VA1912m LED User Manual
Vinotemp Refrigerator VT 6TED WB User Manual
Weber Gas Grill EP 310 320 User Manual