Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power
protection unit for the money, the Ultra UPS line is exactly what you need. An
Ultra UPS is an absolute must for anyone running a small server, workstation or a
powerful PC. You simply cannot afford to cut corners when it comes to
safeguarding your valuable equipment, and these UPS's deliver the
comprehensive protection for computer, peripherals and data files at
remarkably low price.
a
Features
- Line Interactive Design
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
Includes
UPS Monitoring
Software
1000VA
1025VA
1500VA
2000VA
Gneral
Output
Sku
ULT31502
ULT33044
ULT33045
ULT33046
Backup Time
About 50 Minutes
About 50 Minutes
About 60 Minutes
About 65 Minutes
Net Weight Kg (lbs)
Digital Display
Watts
UPS Capacity
No. of Sockets
Voltage (Battery)
Frequency (Battery)
Transfer Time
Voltage (Single Phase)
Frequency
28.6(63.0)
Yes
615
28.6(63.0)
Yes
615
Yes
900
Yes
1200
1025VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
1025VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
1500VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
2000VA
Style A UPSx4, Bypassx2
Simulated square wave output at nominal +/-5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
UPS automatic power off if overload exceeds 110% of
nominal at 60 seconds and 130% at 3 seconds
Input
Protection
Unit Input
Overload Protection
Short Circuit
Surge Protection
Type
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
UPS output shuts off immediately
2100 Joules
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continue beeping sound
Battery
Typical Recharge Time
Protection
Interface
Alarm
USB
Battery Backup
Battery Low
Abnormal Charge
Overload
Environment Ambient Operation
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
3,500m max, Humidity: 0%-95%(without
condensation formation), Temperature: 0-30
͠
͠
͠
͠