Tripp Lite Network-Grade  
Power Distribution Units (PDUs)  
Tripp Lite Network-Grade PDUs are highly reliable multiple-outlet strips that distribute power from a UPS system, generator or utility wall outlet to  
multiple devices. Tripp Lite offers three separate types of rackmount PDUs (see selector guide, below) with features and benefits to match every  
application—networking, server, telecom and more.  
PDU Selector Guide  
(Features/Benefits)  
Choose a PDU by identifying the ideal features and benefits for your application.  
Tripp Lite PDUs  
Basic PDUs  
See page 4  
Metered PDUs  
See page 5  
Switched PDUs  
See pages 6-7  
Feature  
Benefit  
Multiple Outlets  
Increase the number of devices that  
can be powered by a UPS system,  
generator or utility source.  
High-Current Plug and Increase connection flexibility by  
Low-Current Outlets*  
converting a single high-amperage outlet  
into multiple low-amperage outlets.  
Long Input Power Cord Increases installation flexibility by allowing  
devices to be located far from an input  
power source.  
Digital Load Meter  
Avoid overloads and safely add loads  
as total equipment power consumption  
is displayed.  
Remote Control of  
Individual Outlets  
(via SNMP, Web or  
Telnet)  
Reduces frequency of costly service calls  
by rebooting locked devices. Extends  
runtime of critical devices by turning off  
nonessential loads during blackouts.  
Remote monitoring and Prevents overloads that cause  
condition reporting  
equipment downtime.  
* Select models.  
Feature Focus (See page 8)  
• PDUs with Redundant Input Cords and Automatic Transfer Switch (ATS)  
• PDUs with Dual Input Cords and Dual Independent Power Circuits  
See inside for an additional selector guide, application diagrams and complete specifications  
Copyright © 2008 Tripp Lite. All rights reserved. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PDU Application Diagrams  
Tripp Lite PDUs can be used in a variety of applications. The most popular applications are shown below. Contact Tripp Lite's technical support  
department at (773) 869-1234 for additional assistance with a specific application.  
Application #2:  
Application #1:  
Adding More Outlets to a UPS System  
Converting a Single High-Amperage Outlet  
into Multiple Low-Amperage Outlets  
Applicable Tripp Lite PDUs: Models with High-Amperage Plugs  
Applicable Tripp Lite PDUs: All Models  
1
2
Description: PDU plugs into UPS system outlet. PDU increases  
total number of outlets powered by the UPS system (from 6 to 18 in  
this example. Additional front panel outlet not shown.).  
1
Description: PDU plugs into UPS system's high-amperage outlet  
2
(30-amp L5-30R outlet in this example). PDU increases total  
number of low-amperage outlets powered by the UPS system (from 8  
to 32 in this example; additional 12 front panel outlets not shown).  
2
2
PDU2430 Power Distribution Unit (Rear Panel Shown)  
PDU1215 Power Distribution Unit (Rear Panel Shown)  
2
1
2
1
SMART1000RM1U UPS System (Rear Panel Shown)  
SMART3000RM2U UPS System (Rear Panel Shown)  
Application #3:  
Application #4:  
Remotely Controlling Individual Outlets  
(via SNMP, Web or Telnet)  
Distributing Facility UPS/Generator Power  
to Multiple Outlets  
Applicable Tripp Lite PDUs: All Switched Models  
Applicable Tripp Lite PDUs: All Models  
1
1
Description: PDU's Ethernet port connects to network wall jack.  
Description: PDU plugs into a wall outlet supported by facility  
2
2
Remote user controls power to PDU outlets for a variety of  
UPS/generator power. PDU distributes power to equipment via 16  
purposes. Benefits include rebooting locked devices to reduce the  
frequency of costly service calls and turning off nonessential loads  
during blackouts to extend battery backup runtime for critical devices.  
outlets. (All PDU models support facility UPS/generator applications,  
including all available PDU features.)  
Remote Computer  
Network  
Jack  
TCP/IP  
2
2
1
Power Distribution Unit  
(PDUMH30NET Front Panel Shown)  
Power Distribution Unit (PDUMV20HVNET Shown)  
1
From Facility UPS/Generator Source  
SU5000RT4U UPS System (Rear Panel Shown)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Basic PDUs  
Multiple Outlets  
Long Input Power Cord  
All-Metal Cabinet with  
Versatile Mounting Options  
Tripp Lite Basic PDUs reliably distribute AC power from a UPS system, generator or utility wall outlet to multiple devices. Basic PDUs offer high-  
quality plug/outlet connections and a switch-free design to prevent the PDU from being accidentally disconnected or shut down. Versatile all-metal  
cabinets with detachable mounting hardware accommodate a variety of mounting options: wallmount, under-counter and 19-inch rackmount  
mounting in 1U and/or zero-U formats*. Basic PDUs are available in a variety of capacities from 15A to 30A. The PDUNV model features multiple  
detachable plugs to connect the PDU to a variety of outlets. The PDU40TDUAL model features two separate power circuits (with corresponding  
color-coded power cord, circuit breaker and outlets), making it ideal for servers with redundant power supplies and other equipment in loaded racks.  
* See specifications for mounting options supported by each model.  
FEATURES  
A
front panel  
D
front panel  
D
E
E
A
B
B
PDU1215  
rear panel  
rear panel  
front panel  
A
C
F
C
F
PDU1220 & PDU1220T have 5-15/20R outlets  
PDU2430  
D
D
A
A
A
E
E
rear panel  
front panel  
F
B
C
B
PDU1415  
C
PDU1420T has 5-15/20R outlets  
rear panel  
F
A
PDU1230  
D
H
E
C
D
E
(not shown)  
A
A
B
A
H
B
H
rear panel  
F
C
PDUNV  
G
PDU12IEC has C20 inlet for detachable input cord (user-supplied)  
PDU40TDUAL  
A
C
B
C
E
(not shown)  
D
A
A
(not shown)  
E
D
B
PDUV15  
PDUV20 has 5-20P plug and 5-15/20R outlets  
PDUV30HV  
A
B
C
Multiple High-Quality Outlets  
Long Input Cord with High-Quality Input Plug  
AC Circuit Breaker Protection  
D
E
F
G
H
Rugged All-Metal Housing  
Secure Mounting Hardware  
Grounding Lug  
Twist-Lock L5-20P to Straight-Blade 5-20P Plug Adapters  
Dual Circuits  
SPECIFICATIONS  
Input  
Plug  
Type  
Input  
Cord  
Length  
Unit  
Dimensions  
(H x W x D, in) Rackmount Mount  
0U  
Wallmount/  
Input  
Voltage  
Maximum  
Input Current Breakers  
Outlet  
Front  
Outlets  
Rear  
Outlets  
1U  
Vertical Under Counter  
Model  
Qty. & Type(E)  
Mount  
PDU1215  
PDU1220  
PDU1220T  
PDU2430  
PDU1230  
PDU1415  
PDU1420T  
PDU40TDUAL  
PDUNV  
120V  
15A  
20A  
20A  
30A  
1 x 15A  
1 x 20A  
1 x 20A  
2 x 15A  
5-15P  
13 (5-15R)  
13 (5-15/20R)  
13 (5-15/20R)  
24 (5-15R)  
1
1
12  
12  
12  
12  
15 ft.  
15 ft.  
15 ft.  
15 ft.  
15 ft.  
15 ft.  
15 ft.  
2 x 10 ft.  
10 ft.  
n/a  
1.75 x 17.5 x 4.5  
1.75 x 17.5 x 4.5  
1.75 x 17.5 x 4.5  
1.75 x 17.5 x 4.5  
1.75 x 17.5 x 5.25  
1.75 x 25.75 x 2.25  
1.75 x 25.75 x 2.25  
3 x 71 x 1.5  
120V  
5-20P  
120V  
L5-20P  
L5-30P  
L6-30P  
5-15P  
1
120V  
12  
208/240V  
120V  
30A 2 x 15A, 4 x 10A  
18 (2 C19 / 16 C13) 4 C13 / 2 C19 12 C13  
15A  
20A  
1 x 15A  
14 (5-15R)  
14 (5-15/20R)  
40 (5-15/20R)  
n/a  
n/a  
14  
n/a  
n/a  
n/a  
120V  
1 x 20A  
L5-20P  
14  
120V  
2 x 20A  
16A  
2 x 20A L5-20P / 5-20P (2)(B)  
40  
n/a  
100-250V  
100-250V  
120V  
2 x 16A Supports 6 plugs(C) 14 (12 C13 / 2 C19)  
2 x 16A C20 inlet (no cord)(D) 14 (12 C13 / 2 C19)  
4 C13  
4 C13  
12  
8 C13 / 2 C19  
1.75 x 17.5 x 4.25  
1.75 x 17.5 x 4.25  
1.75 x 36 x 1.25  
1.75 x 36 x 1.25  
3.5 x 63.75 x 2.25  
PDU12IEC  
PDUV15  
16A  
8 C13 / 2 C19  
15A  
1 x 15A  
1 x 20A  
2 x 15A  
5-15P  
5-20P  
12 (5-15R)  
12 (5-15/20R)  
n/a  
n/a  
n/a  
15 ft.  
15 ft.  
10 ft.  
n/a  
n/a  
n/a  
PDUV20  
120V  
20A  
30A(A)  
12  
PDUV30HV  
208V  
L6-30P  
38 (32 C13 / 6 C19)  
38  
(A) Code-derated maximum input current is 80% of value shown.  
(B) PDU40TDUAL is a two-corded, dual-circuit PDU in a vertical strip format with (2) twist-lock L5-20P plugs  
and (2) adapters to support connection to straight-blade 5-20R outlets.  
(C) PDUNV includes a C20 input plug, plus 5 adapters which terminate in C14, 5-15P, 5-20P, L5-20P or L6-20P.  
(D) PDU12IEC has a C20 power inlet. User must supply input cord with C19 connection to attach to the PDU,  
and any plug type to connect to a utility source. (E) 5-15/20R outlets accept 5-15P or 5-20P plugs.  
Certifications vary by model.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Metered PDUs  
Digital Load Meter(s)  
Multiple Outlets  
Long Input Power Cord  
All-Metal Cabinet with  
Versatile Mounting Options  
Tripp Lite Metered PDUs reliably distribute AC power from a UPS system, generator or utility wall outlet to multiple devices. Each model features  
a digital load meter that helps you maximize the amount of devices that can be safely added to the PDU (without overloading it) by displaying the  
total power consumption of connected equipment. Metered PDUs offer high-quality plug/outlet connections and a switch-free or switch-protected  
design to prevent the PDU from being accidentally disconnected or shut down. Versatile all-metal cabinets with detachable mounting hardware  
accommodate a variety of mounting options:* wallmount, under-counter and 19-inch rackmount mounting in 1U and/or zero-U formats. Metered  
PDUs are available in 15A, 20A, 30A and 40A capacities. The PDUMV40 model features two separate 20-amp power circuits (with corresponding  
color-coded power cord, circuit breaker, load meter and outlets), making it ideal for servers with redundant power supplies and other equipment in  
loaded racks. The PDUMV30 model includes high-current 120V input with two banks of outlets and dual meters. The PDUMV20HV model  
includes 208/230V input with C13 and C19 outlets. The PDUMV30HV model includes 208V input with two banks of C13 and C19 outlets and dual  
meters. The PDUMV30, PDUMV20HV and PDUMV30HV models also include plug retention brackets that hold connected equipment cables in  
place. The PDUMH15AT and PDUMH20AT models include redundant inputs with Automatic Transfer Switching (see page 8 for more information)  
and are user-upgradeable to switched PDUs (requires SNMPWEBCARD, sold separately).  
* See specifications for mounting options supported by each model.  
FEATURES  
F
A
front panel  
E
J
A
F
E
(not shown)  
B
D
B
PDUMV15  
PDUMV20 has L5-20P plug, 5-20P plug  
adapter and 20 5-15/20R outlets  
rear panel  
C
PDUMH15  
C
D
G
PDUMH20 has L5-20P plug, 5-20P plug adapter and 5-15/20R outlets  
I
I
A
E
(not shown)  
E
(not shown)  
A
K
F
F
D
D
B
K
B
A
B
PDUMV30HV  
C
I
C
PDUMV30 has 24 5-15/20R outlets  
PDUMV20HV has C20 inlet, detachable cord with L6-20P, 8 additional C13 outlets and single meter  
H
PDUMV40  
front panel  
front panel  
B
F
B
A
A
E
E
rear panel  
B
rear panel  
F
C
C
H
PDUMH15AT  
PDUMH20AT  
A
B
C
D
Digital Load Meter  
Multiple High-Quality Outlets  
Long Input Cord with High Quality Input Plug  
AC Circuit Breaker Protection  
E
F
G
H
I
Secure Mounting Hardware  
Rugged All-Metal Housing  
Grounding Lug  
Twist-Lock L5-20P to Straight-Blade 5-20P Plug Adapter  
Dual Circuits  
J
K
Lighted Power Switch with Safety Cover  
Cord Retention Bracket  
SPECIFICATIONS  
Input  
Plug  
Type  
Input  
Cord  
Length  
15 ft.  
15 ft.  
15 ft.  
15 ft.  
2 x 10 ft.  
2 x 12 ft.  
2 x 12 ft.  
10 ft.  
Unit  
Dimensions  
(H x W x D, in) Rackmount Mount  
0U  
Wallmount/  
Input  
Voltage  
120V  
120V  
120V  
120V  
120V  
120V(A)  
120V(A)  
120V  
Maximum  
Input Current  
Outlet  
Front  
Outlets  
Rear  
Outlets  
12  
12  
n/a  
n/a  
n/a  
n/a  
8
n/a  
n/a  
n/a  
1U  
Vertical Under Counter  
Model  
Meters  
1 x 15A  
1 x 20A  
1 x 15A  
1 x 20A  
2 x 20A  
1 x 15A  
1 x 20A  
2 x 20A  
1 x 20A  
2 x 15A  
Qty. & Type(E)  
Mount  
PDUMH15  
PDUMH20  
PDUMV15  
PDUMV20  
PDUMV40  
PDUMH15AT  
PDUMH20AT  
PDUMV30  
PDUMV20HV  
PDUMV30HV  
15A  
20A  
15A  
20A  
2 x 20A  
15A  
5-15P  
L5-20P / 5-20P(C)  
5-15P  
13 (5-15R)  
13 (5-15/20R)  
16 (5-15R)  
20 (5-15/20R)  
32 (5-15/20R)  
8 (5-15R)  
1
1
16  
20  
32  
8
1.75 x 17.5 x 4.5  
1.75 x 17.5 x 4.5  
1.5 x 48 x 1.5  
1.75 x 60 x 1.25  
3 x 71.25 x 1.5  
1.75 x 17.5 x 14.5  
1.75 x 17.5 x 14.5  
3.75 x 63.75 x 2.25  
3.75 x 63.75 x 2.25  
3.5 x 63.75 x 2.25  
n/a  
n/a  
n/a  
L5-20P / 5-20P(C)  
L5-20P / 5-20P (2)(D)  
5-15P  
20A  
L5-20P / 5-20P(C)  
L5-30P  
16 (5-15/20R)  
24 (5-15/20R)  
8
30A(B)  
20A(B)  
30A(B)  
24  
38  
30  
n/a  
n/a  
n/a  
208/230V  
208V  
L6-20P (C20 inlet) 38 (32 C13 / 6 C19)  
10 ft.  
10 ft.  
L6-30P 30 (24 C13 / 6 C19)  
(A) Primary input (fixed cord) tolerances: 99-138V, 45-65Hz. Outside of this range, the PDU switches to the secondary input (detachable cord) if within 99-138V range.  
Two front panel LEDs marked “primary” and “secondary” indicate the active input source.  
(B) Code-derated maximum input current is 80% of value shown.  
(C) Includes a twist-lock L5-20P input plug and an adapter to support connection to a straight blade 5-20R outlet. PDUMH20AT includes (2) cords with twist-lock L5-20P input  
plugs and (2) adapters to support connection to straight-blade 5-20R outlets.  
(D) PDUMV40 is a two-corded, dual-circuit PDU with (2) twist-lock L5-20P plugs and (2) adapters to support connection to straight-blade 5-20R outlets.  
(E) 5-15/20R outlets accept 5-15P or 5-20P plugs.  
Certifications vary by model.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switched PDUs  
Remote Control of Individual Outlets  
Remote Monitoring and Condition Reporting  
Digital Load Meter(s)  
Long Input Power Cord  
All-Metal Cabinet with  
Versatile Mounting Options  
Multiple Outlets  
Tripp Lite Switched PDUs reliably distribute AC power from a UPS system, generator or utility wall outlet to multiple devices. A built-in network  
interface allows users to remotely control individual outlets (and connected devices) via SNMP, Web or Telnet. This feature reduces the frequency of  
costly service calls by enabling remote reboot of locked devices. It can also be used to extend the runtime of critical devices by allowing users to  
turn off nonessential devices during a blackout. Each model features one or more digital load meters that help you maximize the amount of devices  
that can be safely added to the PDU (without overloading it) by displaying the total power consumption of connected equipment. High-quality  
plug/outlet connections and a switch-free design prevent the PDU from being accidentally disconnected or shut down. Versatile all-metal cabinets  
with detachable mounting hardware accommodate a variety of mounting options: wallmount, under-counter and 19-inch rackmount mounting in 1U  
and/or zero-U formats*. Switched PDUs are available in 15A, 20A and 30A capacities.  
* See specifications for mounting options supported by each model.  
SPECIFICATIONS  
Input  
Plug  
Type  
Unit  
Dimensions  
(H x W x D, in)  
0U  
Wallmount/  
Input  
Maximum  
Outlet  
Input Cord  
Length  
1U or 2U Vertical Under Counter  
Rackmount Mount  
Model  
Voltage Input Current  
Meters  
Qty. & Type(E)  
Mount  
Horizontal Models  
PDUMH15ATNET  
PDUMH20ATNET  
PDUMH30NET  
PDUMH15HVNET  
PDUMH20HVNET  
PDUMH30HVNET  
Vertical Models  
PDUMV15NET  
PDUMV20NET  
PDUMV30NET  
PDUMV20HVNET  
PDUMV30HVNET  
120V(A)  
120V(A)  
120V  
15A  
20A  
30A(B)  
15A(B)  
20A(B)  
30A(B)  
1 x 15A  
1 x 20A  
1 (2 x 20A)(C)  
5-15P  
L5-20P / 5-20P(D)  
L5-30P  
8 (5-15R)  
16 (5-15/20R)  
16 (5-15/20R)  
8 (C13)  
2 x 12 ft.  
2 x 12 ft.  
10 ft.  
1.75 x 17.5 x 14.5  
1.75 x 17.5 x 14.5  
3.5 x 17.5 x 12.5  
1.75 x 17.5 x 14.75  
1.75 x 17.5 x 14.75  
3.5 x 17.5 x 12.5  
1U  
1U  
2U  
1U  
1U  
2U  
208/230V  
208/230V  
208V  
1 x 15A  
C14 inlet  
6.5 ft.  
1 x 20A  
1 (2 x 15A)(C)  
L6-20P (C20 inlet)  
L6-30P  
8 (C13)  
8.5 ft.  
16 (C13)  
10 ft.  
120V  
120V  
15A(B)  
20A(B)  
30A(B)  
20A(B)  
30A(B)  
1 x 15A  
1 x 20A  
1 (2 x 20A)(C)  
5-15P  
L5-20P / 5-20P(D)  
L5-30P  
16 (5-15/20R)  
24 (5-15/20R)  
10 ft.  
10 ft.  
10 ft.  
10 ft.  
10 ft.  
4.25 x 49 x 2.25  
4.25 x 63 x 2.25  
4.25 x 70 x 2.25  
4.75 x 64 x 2.25  
4.75 x 70 x 2.25  
n/a  
n/a  
n/a  
n/a  
n/a  
120V  
24 (5-15/20R)  
208/230V  
208V  
1 x 20A  
1 (2 x 15A)(C)  
L6-20P (C20 inlet)  
L6-30P  
24 (20 C13 / 4 C19)  
24 (20 C13 / 4 C19)  
(A) Primary input (fixed cord) tolerances: 99-138V, 45-65Hz. Outside of this range, the PDU switches to the secondary input (detachable cord) if within 99-138V range. Two front panel LEDs marked “primary” and  
“secondary” indicate the active input source. Includes built-in Ethernet jack with programmed and real-time remote control options via SNMP, Web or Telnet.  
(B) Code-derated maximum input current is 80% of value shown.  
(C) Switchable meter displays total load for PDU or for each output bank.  
(D) Includes twist-lock input plug(s) and adapter(s) to support connection to a straight-blade outlet.  
(E) 5-15/20R outlets accept 5-15P or 5-20P plugs.  
Certifications vary by model.  
REMOTE OUTLET CONTROL APPLICATIONS  
A
B
Load Shedding  
Remote Reboot  
A
B
Remote Computer  
Remote Computer  
Network Jack  
Network Jack  
TCP/IP  
TCP/IP  
PDU  
ON  
PDU  
OFF  
Power Cycle  
CRITICAL  
LOAD  
NON-CRITICAL  
LOAD  
LOCKED/FROZEN  
DEVICE  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switched PDUs  
FEATURES  
A
D
A
D
G
front panel  
front panel  
C
C
F
F
F
rear panel  
F
D
I
rear panel  
I
G
E
B
E
B
H
PDUMH15ATNET  
PDUMH20ATNET  
J
E
A
D
C
G
F
A
I
F
F
F
C
D
15  
G
J
J
E
B
I
PDUMH30NET  
PDUMH15HVNET  
J
G
D
G
A
A
C
I
F
F
F
F
15  
15  
C
D
J
B
E
E
J
B
I
PDUMH20HVNET  
PDUMH30HVNET  
A
A
J
C
J
J
J
E
C
D
D
G
G
B
F
D
D
F
(not shown)  
(not shown)  
E
H
B
PDUMV15NET  
PDUMV20NET  
A
A
I
E
J
J
E
C
F
J
J
C
G
D
D
D
D
G
F
B
(not shown)  
(not shown)  
B
PDUMV30NET  
PDUMV20HVNET  
A
Network Interface for Remote Monitoring and Individual Outlet Control  
A
J
J
B
C
E
C
High-Quality Input Plug  
Digital Load Meter  
D
E
Multiple High-Quality Outlets  
Long Input Power Cord  
F
G
Secure Mounting Hardware  
Rugged All-Metal Housing  
H
Twist-Lock L5-20P to Straight-Blade 5-20P Plug Adapter  
D
D
G
F
B
I
J
C14 or C20 Power Inlet  
Cord Retention Bracket  
(not shown)  
PDUMV30HVNET  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
PDUs with Automatic Transfer Switching (ATS)  
Tripp Lite PDUs with Automatic Transfer Switching (ATS) reliably distribute AC power from a UPS system, generator or utility source to multiple  
devices. Each model includes dual AC input plugs and an internal automatic transfer switch between available power sources. These features  
safeguard the uptime of connected devices by automatically providing a backup source of AC power if one source fails or is taken off-line for  
maintenance. The two input cords can be connected to two utility sources, two generator sources, two UPS systems or any combination of these  
sources.  
Providing Redundant Input Power Sources for Single-Cord Devices  
Applicable Tripp Lite PDUs: PDUMH15AT, PDUMH20AT,  
PDUMH15ATNET, PDUMH20ATNET  
Primary Utility/Generator  
Circuit Wall Outlet  
Secondary Utility/Generator  
Circuit Wall Outlet  
1
Description: PDU's primary input plugs into primary UPS system  
2
(attached to its own circuit in this example). PDU's secondary input  
plugs into secondary UPS system (attached to its own circuit in this  
3
example). PDU's internal Automatic Transfer Switch (ATS)  
Secondary UPS System  
(SMART3000RM2U  
Rear Panel Shown)  
monitors voltage and frequency levels, switching to secondary input  
when primary input is outside of safe operating range (99-138V and  
45-65 Hz).  
Primary UPS System  
(SMART3000RM2U  
Rear Panel Shown)  
1
2
*
UP TO 16  
3
Power Distribution Unit  
(PDUMH20AT Rear Panel Shown)  
LOAD  
* Front panel outlets not shown.  
REDUNDANT INPUT APPLICATIONS  
Choose one of the following application configurations to provide redundant input (when desired).  
B
C
A
Utility or Generator  
Power Source  
Utility or Generator  
Power Source  
Utility or Generator  
Power Source  
Utility or Generator  
Power Source  
Utility or Generator  
Utility or Generator  
Power Source  
Power Source  
UPS  
UPS  
UPS  
PDU  
LOAD  
PDU  
LOAD  
PDU  
LOAD  
PDUs with Dual Independent Power Circuits  
Dual Independent Power Circuit PDUs provide an efficient and manageable power distribution solution for multiple servers with redundant power  
supplies, combining the advantages of two separate high-current PDUs without the extra expense, increased space requirements and added  
management complexity. Input plugs, input power cords, breakers and outlets are color-coded to match each independent circuit, allowing simplified  
cable management for multi-server configurations.  
Providing Independent Power Sources for Devices with Redundant Power Cords  
UPS/Utility/  
Generator Source  
UPS/Utility/  
Generator Source  
Applicable Tripp Lite PDUs: PDU40TDUAL, PDUMV40  
1
Description: Each PDU input cord plugs into an independent UPS,  
1
2
utility and/or generator power source. PDU distributes power to  
1
equipment with redundant power supplies (also appropriate for  
equipment without redundant power supplies), providing an  
independent power source for each power supply.  
Power Distribution Unit (PDUMV40 Shown)  
2
Redundant Power Supply Load  
Copyright © 2008 Tripp Lite. All rights reserved.  
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.  
8
200803016 95-2924  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toshiba CRT Television 32HFX72 User Manual
Toshiba DVD VCR Combo MW20FN1 User Manual
Toshiba Personal Computer 2415 Series User Manual
Trane Air Cleaner CAH SVX01A EN User Manual
Vermont Casting Electric Heater 2477CE User Manual
ViewSonic Computer Monitor VA2012WB User Manual
ViewSonic Projector PJD6220 3D User Manual
Vivotek Security Camera FD8133V User Manual
VTech Baby Toy 91 002461 270 User Manual
Weed Eater Blower 545117534 User Manual