Tri M Systems Automobile Parts V104 User Manual

V104 Vehicle Power Supply  
A PC/104 DC to DC Converter  
Manufactured by  
TRI-M ENGINEERING  
Engineered Solutions for Embedded Applications  
Technical Manual  
P/N: V104MAN-V7  
Revision: 12 September 2006  
TRI-M ENGINEERING  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel 604.945.9565  
North America 800.665.5600  
Fax 604.945.9566  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
PREFACE  
This manual is for integrators of applications of embedded systems. It contains information on  
hardware requirements and interconnection to other embedded electronics.  
DISCLAIMER  
Tri-M Engineering makes no representations or warranties with respect to the contents of this  
manual, and specifically disclaims any implied warranties of merchantability or fitness for any  
particular purpose. Tri-M Engineering shall under no circumstances be liable for incidental or  
consequential damages or related expenses resulting from the use of this product, even if it has been  
notified of the possibility of such damages. Tri-M Engineering reserves the right to revise this  
publication from time to time without obligation to notify any person of such revisions. If errors are  
found, please contact Tri-M Engineering at the address listed on the title page of this document.  
COPYRIGHT © 2000-03-22 TRI-M ENGINEERING  
No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or  
translated into any language or computer language, in any form or by any means, electronic,  
mechanical, magnetic, optical, chemical, manual, or otherwise, without the express written permission  
of Tri-M Engineering.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
3
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
CHAPTER 1 - INTRODUCTION  
1.1 GENERAL DESCRIPTION  
The V104 multiple output DC to DC 25 watt converter is a versatile, “bullet-proof” unit that can be  
supplied with as a +5V, outputs only or can include features such as Power Management, Universal  
Battery Charger, AC Bus termination, +12V output, -5V output, -12V output and custom output  
voltages from –42V to +42V. The V104, designed for embedded PC/104 computer systems, has a  
wide input range of 8 to 30V (>6:1) and is ideal for battery or unregulated input applications or low  
voltage AC inputs. The V104 is specifically designed for vehicular applications. It has heavy-duty  
transient suppressors (5000W) that clamp the input voltage to safe levels, while maintaining normal  
power operation. Battery, DC and AC input configurations from 8 to 30V are all handled by the V104  
automatically.  
The V104 is a “simple switcher” based design that provides outstanding line and load regulation with  
efficiencies up to 80 percent. Organic Semi conductor capacitors provide filtering that reduces ripple  
noises below 30mV. The low noise design makes the V104 ideal for applications wherever EMI or  
RFI must be minimized. The +5VDC and +12VDC outputs are controlled by a constant off-time  
current-mode architecture regulator, which provides excellent line and load transient response.  
The +12VDC boost regulator uses the +5VDC as input power and therefore can operate without  
dropout from 8 to 30V input and supply 1A.  
A “plug-in” Universal Battery Charger (UBC104) is available for the V104 to charge Lead-Acid, NiCd  
and NiMh batteries. Charge currents can be up to 1.5A and battery charging voltages from 8 to 30V.  
The Power Management controller (PM104) allows timed on/off control of the V104, bus interrupts on  
impending power failure, current limit setting and intelligent charge termination for the UBC104.  
The V104 is provided in a PC/104 form factor compliant size, which includes the 8bit and 16bit  
PC/104 expansion bus header. All generated voltages are provided to their related power supply pins  
on the PC/104 expansion bus and are all also available for off-board use through a screw terminal  
block. PC/104 AC bus termination is optionally available on the V104, which provides the cleanest  
possible signals on the PC/104 bus.  
The V104 can be configured to meet almost any power supply need for embedded PC/104  
applications, whether that be a simple +5V application, providing power for back lighted LCD panels  
or a full UPS (uninterruptible power supply configuration).  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
4
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
1.2 FEATURES  
-
-
-
-
-
DC to DC converter for PC/104 bus equipped products.  
“Load Dump” transient suppression on input power supply.  
Operates from 8VDC to 30VDC input.  
“Stacks” onto the PC/104 bus.  
Passthrough or non-passthrough 8 bit and 16 bit versions.  
- +5V standard, +12V, -12V, -5V and battery charger optional.  
-
-
-
Highly compact, 100 percent PC/104 conforming.  
AC bus termination available.  
Screw terminals blocks for off-board connection to outputs.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
5
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
1.3 SPECIFICATIONS  
Power Supply Specifications  
Model  
5V output*  
V104  
5A  
1A  
12V output  
-5V output  
400mA  
-12V output  
160mA  
Input Voltage Range  
Load Regulation **  
Line Regulation **  
Output temp. drift **  
Switching Freq.  
8 to 30V  
<30mV  
+ 40mV  
<10mV  
100kHz  
Output Ripple**  
<40mV  
Conducted Susceptibility**  
Efficiency**  
>57db  
Up to 80%  
0 to 70C  
Temp Range  
Quiescent current***  
Weight  
22mA  
150 grams  
3.55"W. x 3.75"L x 0.6" Height  
Size, PC/104 form factor compliant****  
*Current rating includes current supplied to 12V, -12V, & -5V regulators.  
** Measured on the 5V output.  
***LEDs disabled.  
****Not including passthrough pins.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
6
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
CHAPTER 2 – CONFIGURATION AND INSTALLATION  
2.1 Introduction  
This chapter describes the configuration and installation of the V104 power supply. In addition,  
section 2.2 provides a formula to calculate the available +5VDC. Figure 2-1 shows the V104  
connectors, jumper and other options.  
Figure 2-1, V104 Connector and Jumpers  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
7
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2.2 Power Considerations  
The +5V switching regulator is rated at 5A maximum output however, the +5V output supplies power  
to the +12, -5 and –12VDC regulators. The usable range of the +5V output can be calculated using  
the following derating formula.  
Usable +5VDC output = 5A-(I[-5] +I[12]*2.4) /0.80)  
Where:  
I[-5] = -5VDC current load  
I[-12] = -12VDC current load  
I[12] = 12VDC current load  
Assuming 80 percent converter efficiency (actual efficiency may vary).  
2.3.1 Main Input Power Connector  
Input power is connected to the “pluggable” block, CN1, which is removable from the socket  
connector on the circuit board. The power supply accepts DC input voltages in the range of 8VDC to  
30VDC.  
Unregulated vehicle power is connected as follows:  
- Terminal 1: “hot” polarity  
-
Terminal 2: Common (0VDC)  
!! CAUTION !!  
To allow operation at the lowest possible input voltages (8VDC) and for the best efficiency, there is  
NO input reverse-polarity diode provided on the V104 main DC input connector. If reverse-  
polarity protection is required, connect to the AC input connector. See section 2.3.2  
2.3.2 AC Input Power Connector (Optional)  
Low voltage AC is connected to the V104 on screw terminal block, CN7. The V104 accepts AC  
power in the range of 6VAC to 20VAC however, 12VAC to 16VAC is the recommended range. The  
input capacitor on the V104 is 1000uF and is adequate for low power applications drawing one amp.  
Connect an additional 1000uF capacitor to connector CN1 (terminal 1, positive, terminal 2 negative)  
for greater loads.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
8
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2.3.3 Output Power Connector  
Output power is available for non-PC/104 use via connector CN2.  
-
-
-
-
-
Terminal 1: +5VDC output  
Terminal 2: Common  
Terminal 3: +12VDC output (optional)  
Terminal 4: -12VDC output (optional)  
Terminal 5: -5VDC output (optional)  
2.3.4 Battery Power Connector (Optional)  
The batteries are connected to the screw terminal block, CN3. The V104 accepts DC battery  
voltages in the range of 8V to 30VDC through the Battery Power Connector. Two external signals  
can be connected to the battery terminal block for use by add-on modules plugged into the  
mezzanine header connectors. Connect to the V104 Battery Terminal Block as follows:  
- Terminal 1: Common of battery  
-
-
-
Terminal 2: Positive Battery Terminal  
Terminal 3: External signal 1  
Terminal 4: External signal 2  
Note: When optional Plug-IN Boost regulator (VR3) is ordered, batteries or external signals cannot  
be connected to CN3. See section 2.3.5  
2.3.5 Onboard DC “Boost” Converter (Optional)  
Three optional converter “boost” pumps (model NMH05XXS, XX = output voltage, +5V, +9V, +12V,  
+15V) can be installed on the V104. The NMH charge pumps have a maximum 2 watt capacity, but  
require a minimum load of 10 percent for proper operation.  
The –5V output is generated by installing a NMH0505S in location VR4 and adding capacitor C7.  
The –5V output is available on the PC/104 bus (B-7) and on connector block CN2, terminal 4.  
The third optional converter is used for generating custom voltages, which is installed in location VR3  
and adding capacitors C4 and C8. The NMH charge pumps have an isolated positive and negative  
output. By referencing (connecting) the charge pump to other voltages, the user can create +/-  
supplies, elevated and negative voltages (ie. The charge pump “0V” is not connected to the V104  
common).  
- Terminal 1: Common of battery  
-
-
-
Terminal 2: -V output  
Terminal 3: 0V  
Terminal 4: +V output  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
9
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
Example: NMH0515S (+15V) can generate the following voltages:  
- +15V by connecting NMH “0V” to V104 common  
-
-
-
-30V by connecting NMH +V to common  
+30V by connecting NMH –V to common  
+42V by connecting NMH –V to +12V output  
Note: When batteries or external signals are connected to CN3 the Plug-IN Boost regulator (VR3)  
cannot be installed. See section 2.3.4  
2.4 Bus Termination (Optional)  
AC bus termination minimizes power consumption, while improving the reliability of the bus. The  
resistor/ capacitor combination only conducts current during the few nanoseconds when the bus  
signal is changing state.  
2.5 Installation onto PC/104  
The PC/104 bus on the V104 is keyed according to the standards as set out be the PC/104  
Consortium Guidelines. Male Pin B10 of the 8-bit bus and male pin C20 of the 16-bit bus are  
removed but the female sockets are not “plugged”.  
Because of the large number of pins and sockets (104 total) in the PC/104 bus, caution must be used  
in separating the PC/104 modules to prevent bending the pins or hurting the person separating the  
modules. Tri-M Engineering recommends the use of the PC/104 removal tool (model #5535),  
available from Tri-M Engineering.  
2.6.1 LED Jumper Enable/Disable  
These jumpers allow the LEDs to be disabled. This is most likely to be used when absolute minimum  
power consumption must be maintained, such as when operating off a limited battery source.  
The location of each LED jumper is immediately behind each LED.  
Each LED is enabled by factory default. To disable any LED, remove the LED jumper (or cut the  
small PCB trace if no jumper is installed) associated with the LED. To re-enable any LED, re-install  
the associated jumper (or solder a short jumper wire between each of the jumper pads).  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
10  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2.6.2 Mezzanine Expansion Headers  
The mezzanine expansion headers are used for installation of the optional battery charger. The  
mezzanine expansion headers can also be used for custom output voltages such as Vee for LCD  
panels. If custom output voltages are required please contact Tri-M Engineering.  
Figure 2.3, V104 Mezzanine Connectors  
Connector CN5 Pinout  
10. +5V  
Connector CN6 Pinout  
10. Main Pwr. Input  
9. Common  
1. +5V  
1. PM104-P1  
2. Common  
2. Common  
9.Common  
3. +Battery Input  
4. Ext. Signal 1  
5. Ext. Signal 2  
8. Main Pwr Input  
3. PM104-P7  
4. PM104-P6  
5. PM104-P5  
8. PM104-P2  
7. +12V  
6. -5V  
7. PM104-P3  
8. PM104-P4  
Tri-M Engineering  
Tel:  
Fax:  
800.665.5600, 604.945.9565  
604.945.9566  
11  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
E-mail:  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2.6.3 PC/104 Bus Interrupts (Optional)  
Interrupts to the PC/104 bus require the installation of the optional power management  
mircrocontroller (PM104). The PM104 can be programmed to provide indication of loss of input  
power, low battery voltage or to provide indication to the PC/104 CPU to begin an orderly shutdown of  
program operation.  
Two separate interrupt requests can be generated and each interrupt request will remain active until  
the cause of the interrupt request returns to normal. Interrupt Int1 can be set to IRQ6 or IrQ7, while  
Int2 can be set to IRQ4 or IRQ5 by installing a appropriate jumper on jumper selectons block J4.  
Jumper block J4 is located adjacent to the PC/104 bus, on the opposite end where the power LEDs  
are located.  
Figure 2-2, Interrupt IRQ Selection  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
12  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2.7 V104 Efficiency and Heat Dissipation Calculation  
The typical efficiency of the V104 is 80 percent for the +5V output, but efficiency at any specific input  
voltage, output load and ambient temperature may be higher or lower. Typical efficiency is between  
70 and 85 percent. Best efficiency occurs at mid input voltage (16 to 18V), mid output loads (10 to 18  
watts) and low heat sink temperature. As the input voltage and output load is determined by the  
system application, this leaves only the heat sink temperature that System Integrators adjust to  
maximize efficiency. Either forced flow fans or thermally coupling the V104 heat sink to enclosures or  
external heat sinks can improve the efficiency of the V104. Good thermal management can obtain an  
improvement of 3 to 4 percent. The results are that 35 percent less heat is dissipated.  
A) Heat Dissipated (HD) = Input Power – Actual Load  
Where Input Power = Input Voltage * Input Current  
And Actual Load = +5V +(+12V load) + (-5V load) + (-12V load)  
(load measured in watts).  
B) Estimated Heat Dissipated (ESD) can be calculated based on 80 percent efficiency:  
EHD = {+ 5V load + [(+12V load) + (-5V load) + (-12V load)]/0.8} * 0.2  
C) If the Battery Input option is installed additional heat will be dissipated.  
BID = Total Load/ Battery Voltage *0.7V (diode drop)  
D) If the AC Input option (full bridge) is used additional heat will be dissipated.  
ACID = Total Load/ Voltage *1.4 V (2 diode drop)  
E) If the Battery Charger Option is installed the heat dissipated from it will vary according to the  
current charge current and can be estimated by:  
BCD = Maximum Charge Current * charge Voltage * 0/1  
(based on 90 percent efficiency).  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
13  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2.8 Power Management Controller PM104 (optional)  
The Power Management Controller (PM104) is a microcontroller “plug-in” module for timed on-off  
control of the V104, control of the optional battery charger and generation of interrupts to the PC/104  
host CPU. The PM104 is programmed in a high level “controller basic language” called Pbasic. To  
program the PM104, connect the program cable (PM104-Cable) to connector CN4 on the V104 and  
to the parallel port of any PC compatible computer. PM104 programs can be directly downloaded or  
updated using the PM104 utility software.  
Connector CN4 Pinout, PM104 Program Connector  
-
Terminal 1: PM104 Power (leave disconnected if V104 powered)  
- Terminal 2: Common, connect to pin 25 of PC parallel port  
-
-
Terminal 3: PC0, connect to pin 11 (busy) of PC parallel port.  
Terminal 4: PCI, connect to pin 2 (DO) of PC parallel port.  
Table 2.1 PM104 Pin Number and I/O Functions  
PM104 Microcontroller  
IC3 PIN  
V104 Function or Connection  
Battery Charger Function  
Description (IC3)  
1
2
PM104 Supply Voltage  
Common  
V104 Supply Voltage  
Common  
3
PC0 (PC out)  
Connector CN4-3  
Connector CN4-4  
No connection  
4
PCI (Pc in)  
5
Plus 5V input/output  
Reset  
6
No connection  
7
P0 (Input/Output Pin 0)  
P1 (Input/Output Pin 1)  
P2 (Input/Output Pin 2)  
P3 (Input/Output Pin 3)*  
P4 (Input/Output Pin 4)  
P5 (Input/Output Pin 5)  
P6 (Input/Output Pin 6)*  
P7 (Input/Output Pin 7)  
Input Voltage Status  
V104 On/Off Control  
Connector CN6-8  
Int2, Connector CN6-7*  
Connector CN6-6  
Connector CN605  
Int1, Connector CN6-4*  
Connector CN6-3  
8
V104 On/Off control  
9
Analog/Digital Chip Select  
Spare* Input/Output  
Data Input/Output Line  
Data Clock  
10  
11  
12  
13  
14  
Spare* Input/Output  
Analog Current Limit  
If interrupt function is not used, this PM104 line can be used for general purpose Input/Output.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
14  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
CHAPTER 3 – THEORY OF OPERATION  
3.1 Input power protection:  
Input power is connected to the screw terminal block, CN1, which is removable from the socket  
connector on the circuit board. A seven ampere ‘pico’ fuse F1 limits the current draw from the power  
source. A series of devices, (toroid coil L3, transorb D4 and filter capacitor C12) filters and clamps  
the input power.  
Transorb D4 is a 5KVA, heavy duty transient suppressor that provides “zener” type protection and  
has an avalanche voltage of 33V. It is electrically located before fuse F1 to prevent activation of the  
fuse during a “load dump” or large transient. Sustained voltages greater than the avalanche voltage  
must not be applied or transorb D4 will fail.  
3.2 Switching regulator, +5VDC  
A simple switcher regulator VR1, generates the +5VDC output, operating in a “buck” mode switching  
regulator configuration using inductor coil L1, schottky diode Z1, input filter capacitors C12 and output  
filters capacitor C6. Regulator VR1 is a current mode controller and adjusts the “switching cycle” by  
the sensed current rather than directly by the output voltage. Control of the output voltage is obtained  
by using the output of a voltage sensing error amplifier in regulator VR1 to set the current trip level.  
A total of 5 amperes can be supplied to the connected +5VDC load, to the inputs of the +12VDC  
regulator and the –5VDC and –12VDC charge pumps and invertors. The +5VDC power is available  
on the PC/104 expansion bus (B3, B29 and D16) and screw terminal connector CN2. LED2 provides  
indication of +5V operation.  
3.3 Switching regulator, +12VDC  
Switching regulator VR2 generates the +12VDC output, operating in a “boost” mode switching  
regulator configuration using inductor coil L2, Schottky diode D11, input filter capacitor C6 and output  
filters capacitor C3. Capacitor C6 works as an output filter for the +5VDC and as an input filter for the  
+12VDC regulator VR2. Regulator VR2 is a current mode controller and adjusts the “switching cycle”  
by the sensed current rather than directly by the output voltage. Control of the output voltage, sensed  
by resistors R5 and R6, is obtained by using the output of a voltage sensing error amplifier in  
regulator VR2 to set the current trip level. If a custom output voltage is ordered, variable resistor R21  
(in series with R5) will adjust the feedback voltage.  
A total of one ampere can be supplied to the connected +12VDC load and the –12VDC inverter. The  
+12VDC power is available on the PC/104 expansion bus (B9) and screw terminal connector CN2.  
LED1 provides indication of +12VDC operation.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
15  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
3.4 Filter Capacitors  
At 10kHz and above, the impedance of filter capacitors is essentially their effective series resistance  
(ESR) and this parasitic resistance limits the filtering effectiveness of the capacitors. Since the filter  
capacitors must absorb the “switching ripple” current, capacitors with high ESR values will quickly  
overheat. For example, a capacitor with a 100mOhm ESR which is absorbing a 5A ripple current, will  
dissipate 2.5W heat.  
The capacitors used for filtering the +5V and +12V outputs in the V104 are organic semiconductor  
(OS-CON) capacitors. The OS-CON is an aluminium solid capacitor with organic semi-conductive  
electrolyte used as a cathode conductive materials. The OS-CON has many advantages over the  
conventional electrolytic:  
-
Very low ESR values, less than 8 times lower for same package.  
- High ripple current rating, over 4 times higher for same package.  
-
No degrade in operation at extended low temperatures. (ESR value of conventional  
electrolytics can increase 25 fold at –40C).  
The life expectation for a filter capacitor is typically 2,000 to 6,000 hours @ 105C. For a conventional  
electrolytic capacitor the temperature acceleration coefficient = 2 for a 10C increase, while the OS-  
CON has a temperature acceleration coefficient =10 for a 20C increase. For example, a capacitor  
rated for 2,000 hours @ 105C would have an expected life of:  
-
-
for conventional electrolytic capacitor  
32,000 hours (3.6 years) @ 65C  
128,000 hours (14.6 years) @ 45C  
for OS-CON capacitor  
200,000 hours (22 years) @ 65C  
2,000,000 hours (220 years) @ 45C  
This means that the OS-CON has extremely longer life in practical use even under the same warranty  
of 2,000 hours @ 105C.  
In a buck convertor, output ripple voltage is determined by both the inductor value and the output filter  
capacitor (for continuous mode).  
Vp-p = ESR*Vout (Vout/Vin))  
L1 * frequency  
EXAMPLE  
Vout = 5V, Vin = 16V, L1 = 55uH, frequency = 100kHz and 330uF capacitor with 27mohm  
ESR.  
Vp-p = 0.027 * 5 (1- (2/16))  
55 * 10E-6 * 10E5  
~ 17mV ripple  
Tri-M Engineering  
Tel:  
Fax:  
800.665.5600, 604.945.9565  
604.945.9566  
16  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
E-mail:  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
Note: only the ESR of the output capacitor is used in the formula. It is assumed that the  
capacitor is purely resistive at frequencies above 20kHz. Worst case output ripple is at highest  
input voltage and is independent of load.  
3.5 Bus Termination (Optional)  
AC bus termination is provided by 5 “RC” SOIC packages (3 only for 8-bit PC/104 bus), RC1 to RC5  
and discrete components C20 and C27. Each RC package contains 16 resistor/capacitor  
combinations of 47R and 47PF with a common bus connected to the signal ground.  
RC1  
GND  
RC2  
GND  
RC3  
GND  
RC4  
GND  
RC5  
GND  
SA3  
1
2
*SMEMW  
AEN  
IRQ10  
LA22  
*BACK6  
SD9  
SA11  
*Refresh  
SA12  
DRQ1  
SA13  
*DACK1  
SA14  
SA15  
GND  
3
BALE  
SA4  
4
IOCHRDY  
SD0  
IRQ11  
LA21  
DRQ6  
*DACK7  
SD11  
DRQ7  
SD12  
----  
5
IRQ3  
SA5  
6
SD1  
LA20  
7
SRDY  
SD2  
IRQ15  
LA19  
*DACK2  
SA6  
8
9
SD3  
LA18  
SA7  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
GND  
GND  
GND  
GND  
GND  
IRQ6  
SA9  
GND  
GND  
GND  
GND  
SD7  
*MEMR  
LA17  
SD15  
SD14  
SD13  
SD10  
SD8  
*IOW  
SA17  
*IOR  
SD6  
SD5  
LA18  
IRQ5  
SA8  
SD4  
IRQ12  
LA23  
SA16  
*DACK3  
DRQ3  
IRQ7  
DRQ2  
SA19  
*SMEMR  
SA18  
GND  
IRQ4  
DA2  
*IOCS16  
*SBHE  
*MEMCS16  
GND  
DRQ5  
*MEMW  
*DACK5  
GND  
SA1  
SA10  
GND  
SA0  
GND  
In addition, the following signals are terminated with discrete components.  
-
-
TC C1 (330pF)  
Reset C20 (330pF)  
APPENDIX 1  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
17  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
APPENDIX 1  
Advantages of Using AC Termination  
One of the requirements of embedded electronics is for low power consumption. One method  
of reducing power is to reduce the drive current available to power the expansion bus. With  
over 80 signal lines, any reduction in current load would have a large impact on overall  
requirements. The PC/104 Consortium Guidelines for the expansion bus specify drive current  
can be as low as 4mA. Compared with the 24mA for the standard desktop computer, this is an  
84 percent reduction in the drive current available.  
The disadvantage to reducing drive current is the increasing possibility for noise to infilitrate  
the bus. The symptoms of noise induced problems are often “flaky” or unreliable operation.  
Systems suffering from noisy busses are often difficult to diagnose and solve. Programmers  
blame the hardware engineers and the hardware engineers blame the software programmers.  
With reduced drive currents, more attention must be paid to reducing the noise levels on the  
PC/104 bus. One frequently used method is bus terminators. Testing has proven the best  
way to terminate the PC/104 bus is to use AC terminators instead of resistive terminators.  
This is the recommended termination method for Ampro CPU products. The IEEE P996 PC  
Bus Standard recommends the AC bus terminating technique.  
The use of AC terminators has several advantages over DC terminators:  
-
-
Reduced power consumption: DC terminators are typically in the 330 ohm to 1K ohm range  
and draw heavy currents. This is significant when terminating the over 80 signals on the  
PC/104 bus. AC terminators draw current only during the few nanoseconds when the bus  
signal is changing state, resulting in negligible current drain.  
Improved bus reliability: DC terminators invariably increase the voltage level of the logic  
zero state. This decreases noise immunity, making it more likely a zero will be seen as a one.  
AC terminators do not cause this shift, resulting in a more reliable bus.  
-
-
Reduced crosstalk: AC terminators roll off the signal transitions on the bus. The result is a  
quieter bus which has fewer high frequency effects such as crosstalk to other bus lines.  
Reduced EMI. Busses with AC termination tend to generate less EMI than resistively  
terminated buses due to the reduction in high frequency components of signal transitions.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
18  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
APPENDIX 2  
Installation Hints for the V104 Power Supply  
1. To minimize noise induced into the power supply, connect the V104 power supply direct to the  
power supply source (battery) with “dedicated” wires. This makes use of the vehicle battery as  
a filter.  
2. Always use large gauge hook-up wires to connect the V104 power supply to the vehicle power  
source (battery). This minimizes any voltage drop caused by the resistance of the wire. Use  
minimum of AWG #16 for lengths less than 10 feet and AWG #14 for longer lengths.  
3. Wherever possible, install the V104 power supply on to the top of the V104 card stack. This  
will allow better dissipation of heat from the heat sink. If additional cooling is required, use  
either forced air ventilation or mount the PC/104 power supply so that the heat sink can  
dissipate heat to the enclosure.  
APPENDIX 3  
Vehicles Are An Electronics Nightmare  
Under the hood of a vehicle is an electronics nightmare. EMI spraying and RFI sparking is  
everywhere and electrical transients run amuck, zapping the embedded electronics. Electronics  
located in that environment must withstand 600V transients and “load dump” situations. Although  
the automotive market is growing about 2 percent yearly, the amount of electronics being  
introduced into vehicles is much higher. The electronics on a vehicle are no longer just the radio  
and engine computer, but cellular phones, portable computers, faxes, smart navigation with  
Global Positioning Receiver and car alarm systems.  
The infamous “load dump” is an energy surge resulting from disconnecting the battery while being  
charged. The alternator, with a finite response time of 40msec to 400msec, generates power with  
nowhere to go. Thus an energy surge is formed; much like a tidal wave that builds to an  
enormous height as it crashes the beach. The resultant over voltage is the most formidable  
transient encountered in the automotive environment and is an exponentially decaying positive  
voltage. The actual amplitude depends on alternator speed, the level of alternator field excitation  
and can exceed 100V.  
Each electronic component had its own power supply and it is the power supplies that must  
absorb the transients and energy surges. What makes one transient more dangerous than  
another transient is not the voltage level, but the amount of energy it carries. A600V, 1msec  
transient had much less energy than a 100V, 400msec surge. Regardless of the source, all over  
voltages must be clamped and prevented from passing through to the rest of the electronics.  
There are a number of methods for clamping over voltages, but the most efficient and cost  
effective is to shunt the current to ground using a surge suppressor. The surge suppressor relies  
on the vehicle’s wiring and alternator impedance as the current limit and it remains in a high  
impedance state until an over voltage condition occurs. Standard devices such as transorbs  
(P6KE or 1.5KE) will not survive the high-energy discharge of a “load dump”. Special automotive  
suppressors must be used to use up the 20A to 30A peak currents being shunted. Several  
manufacturers, such as Motorola, Harris and Seimens, manufacture suppressors specifically for  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
19  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
automotive applications. Some devices provide “zener diode” style protection, while others  
provide “back to back zener diode” bidirectional protection. Each type has advantages, but unless  
they are used correctly, they will fail to protect the electronics. Ratings on the transient  
suppressors can be confusing. A suppressor with an avalanche voltage of 24V to 32V will have a  
clamp off voltage of over 40V. In addition, ambient temperature can vary from –40C to 70C and  
can result in the avalanche voltage being several volts lower at –40C and a clampoff several volts  
higher at 70C.  
Not all vehicles have 12V battery systems. Some trucks use 24V batteries, aircraft use 28V and  
trains from 45V to 85V. Transient suppressors for aircraft cannot use the 12V system automotive  
components. Instead, a suppressor with an avalanche rating of 35V is needed to allow for low  
ambient temperature compensation, but this results in clamp off of over 70V. Tri-M Engineering’s  
V104 Vehicle Power Supply, employs a Diode Inc. (part#5KP33A), allowing an input voltage range  
of 8V to 30V. If a high clamp off voltage cannot be tolerated, other techniques must be used. A  
series device such as a MOSFET can act as a pre-regulator, but it also must be selected to  
withstand transients. In addition a series device adds to in-efficiency and creates a heat  
dissipation problem, especially at high ambient temperatures.  
“Load dumps” occur infrequently in a vehicle’s lifetime, but any electronics wishing to survive in  
this environment must be designed to withstand the assaults. “Load dumps” co-operate slightly  
through, their worst-case voltage does not typically occur with worst-case source impedance. In  
fact, although the total energy of a “load dump” may be 500 joules, a transient suppressor capable  
of 70 joules typically will be adequate because of the distributed electronics in the vehicles. That  
is, provided the suppressor ratings are the same or larger than other suppressors throughout the  
vehicle. A quick thinking engineer can take advantage of this and design his power supply to  
withstand higher voltages and thus let others’ transient suppressors do the work.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
20  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
APPENDIX 4  
BC104 Battery Charger and PM104 Power Management Units  
1) Description  
When the BC104 and PM104 units are both installed on either the V104 (hereafter referred to as  
PSU), a universal battery charger can be setup and the PSU unit made into an UPS  
(uninterruptible power supply).  
The BC104 is a constant current “buck” switching regulator with an adjustable “float” voltage. The  
float voltage is adjusted via a potentiometer. The PM104 is programmed by the user using a  
“control basic” called Pbasic. A sample program is supplied to show a typical NiCd charging  
control. Before using the BC104 and the PM104 the battery charging program must be set up for  
the intended battery pack. The sample program has separate settings for normal charge current  
and trickle charge current. In addition, the charge termination methods should be set, including  
maximum charge time, negative delta V. The user must set these for the type and size of battery  
to be charged. Typically charge currents will be 1/3 to 1/6 of battery capacity and trickle charge  
current 1/20 to 1/30 of battery capacity. Addition of a battery temperature sensor will allow charge  
termination with elevated battery temperatures (which indicates battery is fully charged).  
The PM104 can be programmed for many additional features not included in the sample program.  
Features such as setting a PC/104 bus interrupt when main power fails, stopping the PSU after  
running on battery backup power for a set time, tracking power consumption so that backup  
battery charging can be terminated when the same amount is restored to the battery. These  
features are left to the OEM integrate into their design.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
21  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
2. Connections:  
The BC104 is mounted on two connectors under the PSU heatsink, CN5 and CN6. The PM104 is  
factory installed directly in front of the PC/104 bus, location IC3. Connector CN4 is for connection  
to a PC parallel port for programming. Batteries are connected to the screw terminal block, CN3.  
The PSU accepts DC battery voltages  
in the range of 8 to 20VDC through the Battery Power Connector CN3. Two external signals can  
be connected to the battery terminal block for use by add-on modules plugged into the mezzanine  
header connectors. Connect to the V104 Battery Terminal Block as follows:  
- Terminal 1: Common of battery  
-
-
-
Terminal 2: Positive Battery Terminal  
Terminal 3: External signal 1, normally connected to terminal 2  
Terminal 4: External signal 2, 0 to 30V input  
The two external signals are fed into the 12 bit analog to digital converter and will accept voltages up  
to 30V. The sample program requires the External signal 1 (Terminal 3) be connected to Positive  
Battery voltage (Terminal 2) for battery voltage sensing.  
A variety of temperature sensors can be connected including thermistors and conditioned sensors  
such as LM35s. The LM35 series is particularly nice because their output voltage is directly  
proportional to temperature (ie 10mV/C or 10mV/F). In any case, the OEM can “experiment” to  
determine what works best in their application.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
22  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
3. Programming Cable:  
The programming cable is plugged into the connector CN4 on the PSU and the other end into the  
25pin DB parallel port connector on a PC. The programming cable has the following connections:  
CN4-1  
CN4-2  
CN4-3  
CN4-4  
No connection  
Connect to pin 25 on parallel port  
Connect to pin 11 parallel port  
Connect to pin 2 parallel port  
4. Download and Edit Software:  
All programs for the PM104 are written in a “Control Basic” program language and are saved into  
an ASCII file with a “BAS” extension. Any text editor can be used to create, edit and save these  
programs. The Download program called “Stamp.exe” also has simple editing capabilities.  
After the program cable is connected between the PSU and the parallel port, the PSU unit can be  
turned on, thus providing power to the PM104 unit. The Download program Stamp. Exe is started  
by typing from DOS, STAMP.EXE. The program to be downloaded is opened by pressing the  
keys “ALT” and “L” simultaneously. Using the arrow keys select the desired file and press ENTER  
key. To download the program press the keys “ALT” and “R” simultaneously. If the cable is  
properly connected and power applied the screen will show a horizontal bar graph indicating the  
percent of program downloaded. The red area of the bar graph is the portion used and the  
remainder is program space available.  
5. Program Command and Syntax:  
Please refer to the Adobe files BSBOOK1.PDF and BSBOOK2.PDF.  
6. Adjusting the BC104 Float Limits:  
When a PC/104 power supply is equipped with a BC104 and a PM104 the BC104 has a Float  
Voltage Adjust potentiometer. However, the Current Limit Adjust potentiometer is not installed  
and is controlled via the PM104.  
Using a small screwdriver (flexible nylon works best), turn the potentiometer until the desired float  
voltage is obtained. No load should be present when adjusting.  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
23  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
7. Sample Battery Charging Program Listing  
The following program listing is intended for use as a guide to customizing the BC104 and PM104  
operation. Additional functions and features can be added including temperature monitoring are  
left up to the OEM to implement.  
BC104, Battery Charger Sample program code  
SYMBOL Pwr_Status = 0  
SYMBOL Pwrp_Status =pin0  
SYMBOL PSU_On/Off = 1  
SYMBOL PSUp_OnOff = pin1  
SYMBOL CS1 = 2  
‘ Status of input power  
‘ Pin number of status of input power  
‘OnOff control of power supply  
‘ Chip select A/D on Battery Charger; 0=active  
‘ PC/104 bus interrupt  
SYMBOL CS1p = pin2  
SYMBOL Int2 = 3  
SYMBOL Int2p = pin3  
SYMBOL DIO = 4  
‘ Pin_number_of data input/output.  
SYMBOL DIOp = pin4  
SYMBOL CLK = 5  
‘ Variable_name_of date input/output.  
‘ Clock to ADC; out on rising, in on falling edge.  
SYMBOL CLKp = pin5  
SYMBOL Int1 = 6  
‘ PC/104 bus interrupt  
SYMBOL Intp = pin6  
SYMBOL Chrg_Limit = 7  
SYMBOL Chrgp_Limit = pin7  
‘ PWM output for current limit  
SYMBOL Bat_Set = bit1  
SYMBOL Adbits = b1  
SYMBOL Bat1_Chrg = bit1  
SYMBOL D0 = bit2  
‘ Counter variable for serial bit reception.  
‘ LSB of ADC channel selection  
SYMBOL D1 = bit3  
‘ second bit of ADC channel selection  
‘D1 = 0, D0 = 0 channel 0 input, pin3 of connector CN3  
‘D1 = 0, D0 = 1 channel 1 input, pin4 of connector CN3  
‘1. on max cell voltage  
‘2. on time  
‘3. –ve delta V  
‘4. cell temperature  
next TCnt  
let D1 = 0  
let D0 = 0  
gosub Convert  
‘Get battery charging voltage  
let Batt_V =AD  
‘debud “charge”  
if AD> BattV_Max then Batt_Chrg_Term  
Chrg_Time = Chrg_Time + 1  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
24  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
If Chrg_Time > Chrg_Time_Max then Batt_Chrg_Term ‘Used maximum charge time  
If AD < Batt_Peak then Batt_DeltaV  
Let AD =AD +Neg_DeltaV  
If AD <Batt_Peak then Batt_Chrg_Term  
**Insert battery pack temperature code here**  
goto Chrg_Lp  
‘Detected negative deltaV in battery pack  
‘Continue until charging terminated  
Batt_Chrg_Term:  
PWM Chrg_ Limit, 0.50  
Let Bat1_Chrg = 1  
Goto Main_Batt1  
‘turn off charge current  
‘Indicate battery has been charged  
Convert:  
ADC Interface Pins  
-The LTC 1594 uses a four-pin interface, consisting of chip-select, clock data input and data output.  
In this application, we tie the data lines together and connect to the PM104 pin designated DIO.  
Here’s where the conversion occurs. The PM104 first sends the setup bits to the LTC1594, then  
clocks in two bits followed by (sample time), one null bit (a dummy bit that always reads 0, followed  
by the conversion data.  
High CS1  
‘ Deactivate the ADC to begin  
High CLK  
‘ Clock data on rising edge, so start with CLK high  
High Dio  
Pulsout CLK.2  
Low DIO  
Pulsout CLK.2  
Let DIOp = D1  
Pulseout CLK.2  
Let DIOp =D0  
Pulsout CLK.2  
Low CS1  
‘next bit of command  
‘next bit of command  
‘Activate the LTC1594  
‘Get ready for input from LTC 1594  
Input DIO  
Pulsout CLK.2  
Input DIO  
‘Dummy statement for delay  
‘Sampling requires two clocks  
Pulsout CLK.2  
Let AD = 0  
‘Clear old ADC result.  
‘Get null bit + 12 data bits.  
‘Clock next data bit in.  
‘Shift AD left, add new data bit.  
‘Get next data bit.  
For Adbits = 1 to 13  
Pulsout CLK.2  
Let AD = AD*2 +DIOp  
Next Adbits  
High CS1  
‘Turn off the ADC  
Tri-M Engineering  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
Tel:  
Fax:  
E-mail:  
800.665.5600, 604.945.9565  
604.945.9566  
25  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
Return  
‘Return to program.  
‘D1 = 1, D0 = 0 channel 2 input, monitors input voltage of battery regulator  
‘D1 = 1, D0 =1 channel 3 input, monitors battery charging current  
‘Note: channel 0 is usually jumpered to CN3 term2 for monitoring battery voltage  
‘Note: channel 2 tracks main power input when greater than battery voltage  
‘Note: channel 2 approx. 0.6V less than battery voltage when main input less than battery  
voltage.  
SYMBOL AD = w1  
12-bit ADC conversion result  
16-bit timer  
Peak voltage detected  
SYMBOL Chrg Time = w2  
SYMBOL Batt_Peak = w3  
SYMBOL TCnt =b8  
SYMBOL Batt_V = w5  
SYMBOL sglDif = 1  
SYMBOL msbf = 1  
SYMBOL AO1_LVL = 5  
SYMBOL BattV_Max = 1100  
SYMBOL Chrg_Time_Max =10800  
SYMBOL Neg_DeltaV = 8  
Single-ended, two-channel mode.  
Output 0s after data transfer is complete.  
Maximum current level (50 = 1A 75 = 1.5A)  
Maximum battery pack charge voltage  
Maximum battery charging time (10,800 = 3hr.)  
AD convertor points for –deltaV (74pt/V IE  
0.2V=18pts).  
SYMBOL Trickle_LVL = 0  
SYMBOL BattV_Min = 740  
Trickle Charge Level (12 =.25A) See below:  
Minimum battery voltage (10V)  
Main Loop  
Init:  
Low PSU_OnOff  
‘Turn PSU on  
Let Bat1_chrg = 0  
Main_Batt1:  
Low PSU_OnOff  
‘Just making sure PSU stays on!  
If Bat1_Chrg = 1 then Batt_Trickle  
Goto Bat_Chrg  
is battery already charged?  
Batt_Trickle:  
‘debug “trickle”  
gosub Chk_Pwr  
let D1 = 0  
let D0 =0  
gosub Convert  
let Batt_V =AD  
PWM Chrg_Limit, Trickle_LVL, 1000  
Low Chrg_Limit  
‘Get battery charging voltage  
‘Turn on Trickle current  
‘Trickle to minimum current  
Tri-M Engineering  
Tel:  
Fax:  
800.665.5600, 604.945.9565  
604.945.9566  
26  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
E-mail:  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
Goto Main_Batt1  
Chk_Pwr:  
Let D1 = 1  
Let D0 = 0  
Gosub Convert  
‘debug AD, Batt_V  
if AD < Batt_V then No_ Power  
return  
‘Get battery charging voltage  
No_Power:  
‘debug “no_pwr”  
pause 50  
let Bat1_Chrg = 0  
PWM Chrg_Limit, 0.50  
Goto Main_Batt1  
‘Indicate battery has been discharged  
‘turn off charge current  
Battery Charger Program  
Batt_Chrg:  
Let Chrg_Time = 0  
Chrg_Lp:  
‘Initialize charge timer (counts in sec.)  
Gosub Chk_Pwr  
For TCnt= 0 to 1  
PWM Chrg_Limit,A01_LVL,1000  
‘first apply charge current then  
‘check for charge termination  
Tri-M Engineering  
Tel:  
Fax:  
800.665.5600, 604.945.9565  
604.945.9566  
27  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
E-mail:  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 September 2006  
V104 Manual  
Distributed By:  
Tri-M Engineering  
Tel:  
Fax:  
800.665.5600, 604.945.9565  
604.945.9566  
28  
1407 Kebet Way, Unit 100  
Port Coquitlam, BC V3C 6L3  
Canada  
E-mail:  
Web site: www.tri-m.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tascam Stereo Receiver US 2x2 User Manual
Technicolor Thomson Telephone 25836 User Manual
Technika Stereo System MC 121IDAB User Manual
Texas Instruments Server Codec Engine Server User Manual
Thermador Food Warmer WDC30E User Manual
TP Link Dishwasher TL SG1008 User Manual
TP Link Network Card TL PA6030 User Manual
Tripp Lite Network Cables N105 025 GY User Manual
Universal Remote Control Universal Remote UR4 DCT 4 in 1 Cable Remote Control User Manual
Vidikron Projection Television Vision 30 User Manual